Home
last modified time | relevance | path

Searched hist:"8 f092316" (Results 1 – 6 of 6) sorted by relevance

/qemu/hw/ppc/
H A Dpnv_homer.c8f092316 Wed Dec 11 08:29:11 GMT 2019 Cédric Le Goater <clg@kaod.org> ppc/pnv: Introduce PBA registers

The PBA bridge unit (Power Bus Access) connects the OCC (On Chip
Controller) to the Power bus and System Memory. The PBA is used to
gather sensor data, for power management, for sleep states, for
initial boot, among other things.

The PBA logic provides a set of four registers PowerBus Access Base
Address Registers (PBABAR0..3) which map the OCC address space to the
PowerBus space. These registers are setup by the initial FW and define
the PowerBus Range of system memory that can be accessed by PBA.

The current modeling of the PBABAR registers is done under the common
XSCOM handlers. We introduce a specific XSCOM regions for these
registers and fix :

- BAR sizes and BAR masks
- The mapping of the OCC common area. It is common to all chips and
should be mapped once. We will address per-OCC area in the next
change.
- OCC common area is in BAR 3 on P8

Inspired by previous work of Balamuruhan S <bala24@linux.ibm.com>

Signed-off-by: Cédric Le Goater <clg@kaod.org>
Message-Id: <20191211082912.2625-2-clg@kaod.org>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
H A Dpnv_xscom.c8f092316 Wed Dec 11 08:29:11 GMT 2019 Cédric Le Goater <clg@kaod.org> ppc/pnv: Introduce PBA registers

The PBA bridge unit (Power Bus Access) connects the OCC (On Chip
Controller) to the Power bus and System Memory. The PBA is used to
gather sensor data, for power management, for sleep states, for
initial boot, among other things.

The PBA logic provides a set of four registers PowerBus Access Base
Address Registers (PBABAR0..3) which map the OCC address space to the
PowerBus space. These registers are setup by the initial FW and define
the PowerBus Range of system memory that can be accessed by PBA.

The current modeling of the PBABAR registers is done under the common
XSCOM handlers. We introduce a specific XSCOM regions for these
registers and fix :

- BAR sizes and BAR masks
- The mapping of the OCC common area. It is common to all chips and
should be mapped once. We will address per-OCC area in the next
change.
- OCC common area is in BAR 3 on P8

Inspired by previous work of Balamuruhan S <bala24@linux.ibm.com>

Signed-off-by: Cédric Le Goater <clg@kaod.org>
Message-Id: <20191211082912.2625-2-clg@kaod.org>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
H A Dpnv.c8f092316 Wed Dec 11 08:29:11 GMT 2019 Cédric Le Goater <clg@kaod.org> ppc/pnv: Introduce PBA registers

The PBA bridge unit (Power Bus Access) connects the OCC (On Chip
Controller) to the Power bus and System Memory. The PBA is used to
gather sensor data, for power management, for sleep states, for
initial boot, among other things.

The PBA logic provides a set of four registers PowerBus Access Base
Address Registers (PBABAR0..3) which map the OCC address space to the
PowerBus space. These registers are setup by the initial FW and define
the PowerBus Range of system memory that can be accessed by PBA.

The current modeling of the PBABAR registers is done under the common
XSCOM handlers. We introduce a specific XSCOM regions for these
registers and fix :

- BAR sizes and BAR masks
- The mapping of the OCC common area. It is common to all chips and
should be mapped once. We will address per-OCC area in the next
change.
- OCC common area is in BAR 3 on P8

Inspired by previous work of Balamuruhan S <bala24@linux.ibm.com>

Signed-off-by: Cédric Le Goater <clg@kaod.org>
Message-Id: <20191211082912.2625-2-clg@kaod.org>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
/qemu/include/hw/ppc/
H A Dpnv_homer.h8f092316 Wed Dec 11 08:29:11 GMT 2019 Cédric Le Goater <clg@kaod.org> ppc/pnv: Introduce PBA registers

The PBA bridge unit (Power Bus Access) connects the OCC (On Chip
Controller) to the Power bus and System Memory. The PBA is used to
gather sensor data, for power management, for sleep states, for
initial boot, among other things.

The PBA logic provides a set of four registers PowerBus Access Base
Address Registers (PBABAR0..3) which map the OCC address space to the
PowerBus space. These registers are setup by the initial FW and define
the PowerBus Range of system memory that can be accessed by PBA.

The current modeling of the PBABAR registers is done under the common
XSCOM handlers. We introduce a specific XSCOM regions for these
registers and fix :

- BAR sizes and BAR masks
- The mapping of the OCC common area. It is common to all chips and
should be mapped once. We will address per-OCC area in the next
change.
- OCC common area is in BAR 3 on P8

Inspired by previous work of Balamuruhan S <bala24@linux.ibm.com>

Signed-off-by: Cédric Le Goater <clg@kaod.org>
Message-Id: <20191211082912.2625-2-clg@kaod.org>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
H A Dpnv_xscom.h8f092316 Wed Dec 11 08:29:11 GMT 2019 Cédric Le Goater <clg@kaod.org> ppc/pnv: Introduce PBA registers

The PBA bridge unit (Power Bus Access) connects the OCC (On Chip
Controller) to the Power bus and System Memory. The PBA is used to
gather sensor data, for power management, for sleep states, for
initial boot, among other things.

The PBA logic provides a set of four registers PowerBus Access Base
Address Registers (PBABAR0..3) which map the OCC address space to the
PowerBus space. These registers are setup by the initial FW and define
the PowerBus Range of system memory that can be accessed by PBA.

The current modeling of the PBABAR registers is done under the common
XSCOM handlers. We introduce a specific XSCOM regions for these
registers and fix :

- BAR sizes and BAR masks
- The mapping of the OCC common area. It is common to all chips and
should be mapped once. We will address per-OCC area in the next
change.
- OCC common area is in BAR 3 on P8

Inspired by previous work of Balamuruhan S <bala24@linux.ibm.com>

Signed-off-by: Cédric Le Goater <clg@kaod.org>
Message-Id: <20191211082912.2625-2-clg@kaod.org>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>
H A Dpnv.h8f092316 Wed Dec 11 08:29:11 GMT 2019 Cédric Le Goater <clg@kaod.org> ppc/pnv: Introduce PBA registers

The PBA bridge unit (Power Bus Access) connects the OCC (On Chip
Controller) to the Power bus and System Memory. The PBA is used to
gather sensor data, for power management, for sleep states, for
initial boot, among other things.

The PBA logic provides a set of four registers PowerBus Access Base
Address Registers (PBABAR0..3) which map the OCC address space to the
PowerBus space. These registers are setup by the initial FW and define
the PowerBus Range of system memory that can be accessed by PBA.

The current modeling of the PBABAR registers is done under the common
XSCOM handlers. We introduce a specific XSCOM regions for these
registers and fix :

- BAR sizes and BAR masks
- The mapping of the OCC common area. It is common to all chips and
should be mapped once. We will address per-OCC area in the next
change.
- OCC common area is in BAR 3 on P8

Inspired by previous work of Balamuruhan S <bala24@linux.ibm.com>

Signed-off-by: Cédric Le Goater <clg@kaod.org>
Message-Id: <20191211082912.2625-2-clg@kaod.org>
Signed-off-by: David Gibson <david@gibson.dropbear.id.au>