Home
last modified time | relevance | path

Searched hist:d18fdd69 (Results 1 – 3 of 3) sorted by relevance

/qemu/include/hw/timer/
H A Dstellaris-gptm.hd18fdd69 Thu Aug 12 09:33:55 GMT 2021 Peter Maydell <peter.maydell@linaro.org> hw/timer/stellaris-gptm: Use Clock input instead of system_clock_scale

The stellaris-gptm timer currently uses system_clock_scale for one of
its timer modes where the timer runs at the CPU clock rate. Make it
use a Clock input instead.

We don't try to make the timer handle changes in the clock frequency
while the downcounter is running. This is not a change in behaviour
from the previous system_clock_scale implementation -- we will pick
up the new frequency only when the downcounter hits zero. Handling
dynamic clock changes when the counter is running would require state
that the current gptm implementation doesn't have.

Signed-off-by: Peter Maydell <peter.maydell@linaro.org>
Reviewed-by: Damien Hedde <damien.hedde@greensocs.com>
Message-id: 20210812093356.1946-25-peter.maydell@linaro.org
/qemu/hw/timer/
H A Dstellaris-gptm.cd18fdd69 Thu Aug 12 09:33:55 GMT 2021 Peter Maydell <peter.maydell@linaro.org> hw/timer/stellaris-gptm: Use Clock input instead of system_clock_scale

The stellaris-gptm timer currently uses system_clock_scale for one of
its timer modes where the timer runs at the CPU clock rate. Make it
use a Clock input instead.

We don't try to make the timer handle changes in the clock frequency
while the downcounter is running. This is not a change in behaviour
from the previous system_clock_scale implementation -- we will pick
up the new frequency only when the downcounter hits zero. Handling
dynamic clock changes when the counter is running would require state
that the current gptm implementation doesn't have.

Signed-off-by: Peter Maydell <peter.maydell@linaro.org>
Reviewed-by: Damien Hedde <damien.hedde@greensocs.com>
Message-id: 20210812093356.1946-25-peter.maydell@linaro.org
/qemu/hw/arm/
H A Dstellaris.cd18fdd69 Thu Aug 12 09:33:55 GMT 2021 Peter Maydell <peter.maydell@linaro.org> hw/timer/stellaris-gptm: Use Clock input instead of system_clock_scale

The stellaris-gptm timer currently uses system_clock_scale for one of
its timer modes where the timer runs at the CPU clock rate. Make it
use a Clock input instead.

We don't try to make the timer handle changes in the clock frequency
while the downcounter is running. This is not a change in behaviour
from the previous system_clock_scale implementation -- we will pick
up the new frequency only when the downcounter hits zero. Handling
dynamic clock changes when the counter is running would require state
that the current gptm implementation doesn't have.

Signed-off-by: Peter Maydell <peter.maydell@linaro.org>
Reviewed-by: Damien Hedde <damien.hedde@greensocs.com>
Message-id: 20210812093356.1946-25-peter.maydell@linaro.org