Home
last modified time | relevance | path

Searched refs:VSC (Results 1 – 25 of 586) sorted by relevance

12345678910>>...24

/dports/editors/calligra/calligra-3.2.1/plugins/stencilsdocker/stencils/Cisco/
H A Dvsc3000.desktop2 Name=Virtual switch controller (VSC 3000)
4 Name[bs]=Virtualni prekidački kontroler (VSC 3000)
5 Name[ca]=Virtual switch controller (VSC 3000)
7 Name[da]=Virtual switch controller (VSC 3000)
8 Name[de]=Virtual-Switch-Controller (VSC 3000)
16 Name[hu]=Virtuális switch vezérlő (VSC 3000)
17 Name[it]=Virtual switch controller (VSC 3000)
19 Name[ko]=가상 스위치 컨트롤러(VSC 3000)
29 Name[sv]=Virtuell växelstyrenhet (VSC 3000)
33 Name[zh_CN]=虚似交换机控制器 (VSC 3000)
[all …]
/dports/net-mgmt/librenms/librenms-21.5.1/mibs/hpmsm/
H A DCOLUBRIS-VSC-MIB.my2 -- COLUBRIS-VSC-MIB definitions
12 COLUBRIS-VSC-MIB DEFINITIONS ::= BEGIN
87 DESCRIPTION "Specifies the index of a Virtual Service Community (VSC)
95 DESCRIPTION "The friendly name associated with the VSC."
102 DESCRIPTION "Service Set ID assigned to the VSC."
109 DESCRIPTION "Indicates if the VSC is access controlled."
123 DESCRIPTION "Indicates the type of security used by the VSC."
137 DESCRIPTION "Indicates the encryption type supported by the VSC."
149 DESCRIPTION "Indicates the 802.1x authentication type supported by the VSC."
156 DESCRIPTION "Indicates if MAC authentication is enabled on the VSC."
[all …]
/dports/net-mgmt/observium/observium/mibs/alvarion/
H A DALVARION-VSC-MIB2 -- ALVARION-VSC-MIB definitions
12 ALVARION-VSC-MIB DEFINITIONS ::= BEGIN
84 DESCRIPTION "Specifies the index of a Virtual Service Community (VSC)
92 DESCRIPTION "The friendly name associated with the VSC."
99 DESCRIPTION "Service Set ID assigned to the VSC."
106 DESCRIPTION "Indicates if the VSC is access controlled."
120 DESCRIPTION "Indicates the type of security used by the VSC."
134 DESCRIPTION "Indicates the encryption type supported by the VSC."
146 DESCRIPTION "Indicates the 802.1x authentication type supported by the VSC."
153 DESCRIPTION "Indicates if MAC authentication is enabled on the VSC."
[all …]
/dports/www/chromium-legacy/chromium-88.0.4324.182/third_party/perfetto/test/trace_processor/parsing/
H A Dandroid_log_msgs.out24 "@ 1507.130: [VSC] Request sensor 65537, sample_duration 14 ms, report_duration 64 ms",1
25 "@ 1507.131: [VSC] Stopping sensor events for sensor 131074",1
28 "@ 1508.133: [VSC] Stopping sensor events for sensor 65537",1
29 "@ 1508.134: [VSC] Request sensor 65544, sample_duration 42 ms, report_duration 42 ms",1
/dports/net-mgmt/netdisco-mibs/netdisco-mibs-4.010/colubris/
H A Dcolubris-vsc-mib.my2 -- COLUBRIS-VSC-MIB definitions
13 COLUBRIS-VSC-MIB DEFINITIONS ::= BEGIN
88 DESCRIPTION "Specifies the index of a Virtual Service Community (VSC)
96 DESCRIPTION "The friendly name associated with the VSC."
103 DESCRIPTION "Service Set ID assigned to the VSC."
110 DESCRIPTION "Indicates if the VSC is access-controlled."
124 DESCRIPTION "Indicates the type of wireless protection used by the VSC."
158 DESCRIPTION "Indicates if MAC authentication is enabled on the VSC."
166 VSC. Always false on an AP."
/dports/net-mgmt/observium/observium/mibs/colubris/
H A DCOLUBRIS-VSC-MIB2 -- COLUBRIS-VSC-MIB definitions
13 COLUBRIS-VSC-MIB DEFINITIONS ::= BEGIN
88 DESCRIPTION "Specifies the index of a Virtual Service Community (VSC)
96 DESCRIPTION "The friendly name associated with the VSC."
103 DESCRIPTION "Service Set ID assigned to the VSC."
110 DESCRIPTION "Indicates if the VSC is access-controlled."
124 DESCRIPTION "Indicates the type of wireless protection used by the VSC."
158 DESCRIPTION "Indicates if MAC authentication is enabled on the VSC."
166 VSC. Always false on an AP."
/dports/emulators/qemu42/qemu-4.2.1/roms/u-boot/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.
/dports/emulators/qemu5/qemu-5.2.0/roms/u-boot/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.
/dports/sysutils/u-boot-olimex-a20-som-evb/u-boot-2021.07/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.
/dports/sysutils/u-boot-olinuxino-lime/u-boot-2021.07/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.
/dports/sysutils/u-boot-olinuxino-lime2/u-boot-2021.07/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.
/dports/sysutils/u-boot-olinuxino-lime2-emmc/u-boot-2021.07/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.
/dports/sysutils/u-boot-cubieboard2/u-boot-2021.07/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.
/dports/sysutils/u-boot-cubox-hummingboard/u-boot-2021.07/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.
/dports/sysutils/u-boot-firefly-rk3399/u-boot-2021.07/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.
/dports/sysutils/u-boot-sinovoip-bpi-m3/u-boot-2021.07/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.
/dports/sysutils/u-boot-a64-olinuxino/u-boot-2021.07/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.
/dports/sysutils/u-boot-sopine/u-boot-2021.07/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.
/dports/sysutils/u-boot-qemu-arm64/u-boot-2021.07/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.
/dports/sysutils/u-boot-rpi/u-boot-2021.07/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.
/dports/sysutils/u-boot-nanopi-r4s/u-boot-2021.07/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.
/dports/sysutils/u-boot-nanopi-m1plus/u-boot-2021.07/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.
/dports/sysutils/u-boot-nanopi-neo/u-boot-2021.07/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.
/dports/sysutils/u-boot-chip/u-boot-2021.07/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.
/dports/sysutils/u-boot-beaglebone/u-boot-2021.07/doc/
H A DREADME.VSC3316-33088 VSC 3316/3308 is a low-power, low-cost asynchronous crosspoint switch capable of data rates upto 11…
14 On reset, VSC devices are in low-power state with all inputs, outputs and connections in an off sta…
23 …This API programs VSC to interface with either two-wire or four-wire interface. In our case the in…
25 vsc_addr - Address of the VSC device on board.
30 …This API configures the VSC3316 device for required connections. Connection through the VSC device…
35 vsc_addr - Address of the VSC device on board.
43 vsc_addr - Address of the VSC device on board.

12345678910>>...24