/dports/games/NBlood/NBlood-a1689a4/package/sdk/samples/ |
H A D | weapons.sample.con | 230 addvar hud_x 250 233 addvar hud_y 258 247 addvar hud_x 40 250 addvar hud_y 200 356 addvar hud_x 8 357 addvar hud_y 10 386 addvar hud_y 249 395 addvar hud_x 130 407 addvar hud_x 152 410 addvar hud_x 22 [all …]
|
H A D | startpos.m32 | 69 addvar DM_size 1 71 addvar coop_size 1 108 addvar j 1 118 addvar k 1 172 addvar DM 1 191 addvar j 1 193 addvar k 1 225 addvar j 1 227 addvar k 1 258 addvar j 1 [all …]
|
/dports/math/octave-forge-fuzzy-logic-toolkit/fuzzy-logic-toolkit/inst/ |
H A D | addvar.m | 48 ## Filename: addvar.m 51 function fis = addvar (fis, in_or_out, var_name, var_range) function 57 puts ("Type 'help addvar' for more information.\n"); 58 error ("addvar requires 4 arguments\n"); 60 puts ("Type 'help addvar' for more information.\n"); 61 error ("addvar's first argument must be an FIS structure\n"); 64 puts ("Type 'help addvar' for more information.\n"); 67 puts ("Type 'help addvar' for more information.\n"); 68 error ("addvar's third argument must be a string\n\n"); 70 puts ("Type 'help addvar' for more information.\n"); [all …]
|
/dports/sysutils/nut-devel/nut-9e6a5ab2/drivers/ |
H A D | generic_modbus.c | 301 addvar(VAR_VALUE, "device_mfr", "device manufacturer"); in upsdrv_makevartable() 302 addvar(VAR_VALUE, "device_model", "device model"); in upsdrv_makevartable() 303 addvar(VAR_VALUE, "ser_baud_rate", "serial port baud rate"); in upsdrv_makevartable() 304 addvar(VAR_VALUE, "ser_parity", "serial port parity"); in upsdrv_makevartable() 305 addvar(VAR_VALUE, "ser_data_bit", "serial port data bit"); in upsdrv_makevartable() 306 addvar(VAR_VALUE, "ser_stop_bit", "serial port stop bit"); in upsdrv_makevartable() 307 addvar(VAR_VALUE, "rio_slave_id", "RIO modbus slave ID"); in upsdrv_makevartable() 308 addvar(VAR_VALUE, "OL_addr", "modbus address for OL state"); in upsdrv_makevartable() 309 addvar(VAR_VALUE, "OB_addr", "modbus address for OB state"); in upsdrv_makevartable() 310 addvar(VAR_VALUE, "LB_addr", "modbus address for LB state"); in upsdrv_makevartable() [all …]
|
H A D | genericups.c | 361 addvar(VAR_VALUE, "upstype", "Set UPS type (required)"); in upsdrv_makevartable() 362 addvar(VAR_VALUE, "mfr", "Override manufacturer name"); in upsdrv_makevartable() 363 addvar(VAR_VALUE, "model", "Override model name"); in upsdrv_makevartable() 364 addvar(VAR_VALUE, "serial", "Specify the serial number"); in upsdrv_makevartable() 365 addvar(VAR_VALUE, "CP", "Override cable power setting"); in upsdrv_makevartable() 366 addvar(VAR_VALUE, "OL", "Override on line signal"); in upsdrv_makevartable() 367 addvar(VAR_VALUE, "LB", "Override low battery signal"); in upsdrv_makevartable() 368 addvar(VAR_VALUE, "RB", "Override replace battery signal"); in upsdrv_makevartable() 369 addvar(VAR_VALUE, "BYPASS", "Override battery bypass signal"); in upsdrv_makevartable() 370 addvar(VAR_VALUE, "SD", "Override shutdown setting"); in upsdrv_makevartable() [all …]
|
H A D | powerpanel.c | 189 addvar(VAR_VALUE, "ondelay", "Delay before UPS startup"); in upsdrv_makevartable() 190 addvar(VAR_VALUE, "offdelay", "Delay before UPS shutdown"); in upsdrv_makevartable() 192 addvar(VAR_VALUE, "manufacturer", "manufacturer"); in upsdrv_makevartable() 193 addvar(VAR_VALUE, "model", "modelname"); in upsdrv_makevartable() 194 addvar(VAR_VALUE, "serial", "serialnumber"); in upsdrv_makevartable() 195 addvar(VAR_VALUE, "protocol", "protocol to use [text|binary] (default: autodection)"); in upsdrv_makevartable()
|
H A D | libusb.c | 58 addvar(VAR_VALUE, "vendor", "Regular expression to match UPS Manufacturer string"); in nut_usb_addvars() 59 addvar(VAR_VALUE, "product", "Regular expression to match UPS Product string"); in nut_usb_addvars() 60 addvar(VAR_VALUE, "serial", "Regular expression to match UPS Serial number"); in nut_usb_addvars() 62 …addvar(VAR_VALUE, "vendorid", "Regular expression to match UPS Manufacturer numerical ID (4 digits… in nut_usb_addvars() 63 …addvar(VAR_VALUE, "productid", "Regular expression to match UPS Product numerical ID (4 digits hex… in nut_usb_addvars() 65 addvar(VAR_VALUE, "bus", "Regular expression to match USB bus name"); in nut_usb_addvars() 66 addvar(VAR_VALUE, "device", "Regular expression to match USB device name"); in nut_usb_addvars() 67 …addvar(VAR_VALUE, "usb_set_altinterface", "Force redundant call to usb_set_altinterface() (value=b… in nut_usb_addvars()
|
H A D | clone.c | 543 addvar(VAR_VALUE, "offdelay", "Delay before outlet shutdown (seconds)"); in upsdrv_makevartable() 544 addvar(VAR_VALUE, "ondelay", "Delay before outlet startup (seconds)"); in upsdrv_makevartable() 546 addvar(VAR_VALUE, "mincharge", "Remaining battery level when UPS switches to LB (percent)"); in upsdrv_makevartable() 547 addvar(VAR_VALUE, "minruntime", "Remaining battery runtime when UPS switches to LB (seconds)"); in upsdrv_makevartable() 549 addvar(VAR_VALUE, "load.off", "Command to switch off outlet"); in upsdrv_makevartable() 550 addvar(VAR_VALUE, "load.on", "Command to switch on outlet"); in upsdrv_makevartable() 551 addvar(VAR_VALUE, "load.status", "Variable that indicates outlet is on/off"); in upsdrv_makevartable()
|
H A D | safenet.c | 458 addvar(VAR_VALUE, "manufacturer", "manufacturer [unknown]"); in upsdrv_makevartable() 459 addvar(VAR_VALUE, "modelname", "modelname [unknown]"); in upsdrv_makevartable() 460 addvar(VAR_VALUE, "serialnumber", "serialnumber [unknown]"); in upsdrv_makevartable() 462 addvar(VAR_VALUE, "ondelay", "Delay before UPS startup (minutes)"); in upsdrv_makevartable() 463 addvar(VAR_VALUE, "offdelay", "Delay before UPS shutdown (seconds)"); in upsdrv_makevartable()
|
H A D | nutdrv_qx_masterguard.c | 1047 addvar(VAR_VALUE, "series", "Series (A/E)"); in masterguard_makevartable() 1048 addvar(VAR_VALUE, "slave_address", "Slave address (UPS id) to match"); in masterguard_makevartable() 1050 addvar(VAR_VALUE, "number_of_battery_cells", "Number of battery cells in series"); in masterguard_makevartable() 1051 addvar(VAR_VALUE, "nominal_cell_voltage", "Nominal battery cell voltage"); in masterguard_makevartable() 1052 addvar(VAR_VALUE, "runtime_half", "Nominal battery run time at 50% load (seconds)"); in masterguard_makevartable() 1055 addvar(VAR_VALUE, "output_voltages", "Possible output voltages (volts)"); in masterguard_makevartable() 1056 addvar(VAR_VALUE, "fault_1", "Fault record 1 (newest)"); in masterguard_makevartable() 1057 addvar(VAR_VALUE, "fault_2", "Fault record 2"); in masterguard_makevartable() 1058 addvar(VAR_VALUE, "fault_3", "Fault record 3"); in masterguard_makevartable() 1059 addvar(VAR_VALUE, "fault_4", "Fault record 4"); in masterguard_makevartable() [all …]
|
H A D | powercom.c | 1165 addvar(VAR_VALUE, "type", in upsdrv_makevartable() 1168 addvar(VAR_VALUE, "manufacturer", in upsdrv_makevartable() 1170 addvar(VAR_VALUE, "modelname", in upsdrv_makevartable() 1172 addvar(VAR_VALUE, "serialnumber", in upsdrv_makevartable() 1174 addvar(VAR_VALUE, "shutdownArguments", in upsdrv_makevartable() 1176 addvar(VAR_VALUE, "linevoltage", in upsdrv_makevartable() 1178 addvar(VAR_VALUE, "numOfBytesFromUPS", in upsdrv_makevartable() 1182 addvar(VAR_VALUE, "validationSequence", in upsdrv_makevartable() 1185 addvar(VAR_VALUE, "frequency", in upsdrv_makevartable() 1187 addvar(VAR_VALUE, "loadPercentage", in upsdrv_makevartable() [all …]
|
/dports/games/NBlood/NBlood-a1689a4/source/rr/src/lunatic/test/ |
H A D | mapstate.con | 74 addvar dq 1 75 addvar y 8 134 addvar numwarps 1 135 addvar numwarpsD 1 136 addvar numwarpsR 1 137 addvar numwarpsDR 1 139 addvar Pnumwarps 1 140 addvar PnumwarpsD 1 141 addvar PnumwarpsR 1 144 addvar Anumwarps 1 [all …]
|
H A D | screentext.con | 104 addvar y 8 113 addvar temp 1 114 addvar y 8 147 addvar y 8 165 addvar y 4 309 addvar charangle 256 310 addvar y 13 312 addvar charangle 256 313 addvar y 13 315 addvar charangle 256 [all …]
|
H A D | switch.con | 26 addvar j 1 57 addvar j 1 68 addvar j 1 72 addvar j 1 93 addvar j 1
|
H A D | sprite_access.con | 24 addvar i 1 38 addvar i 1 48 addvar n 1 91 addvar alpha 128 // [0 .. 256]
|
/dports/math/R-cran-lava/lava/man/ |
H A D | addvar.Rd | 2 % Please edit documentation in R/addvar.R 3 \name{addvar} 4 \alias{addvar} 5 \alias{addvar<-} 8 addvar(x, ...)
|
/dports/sysutils/nut/nut-2.7.4/drivers/ |
H A D | powerpanel.c | 189 addvar(VAR_VALUE, "ondelay", "Delay before UPS startup"); in upsdrv_makevartable() 190 addvar(VAR_VALUE, "offdelay", "Delay before UPS shutdown"); in upsdrv_makevartable() 192 addvar(VAR_VALUE, "manufacturer", "manufacturer"); in upsdrv_makevartable() 193 addvar(VAR_VALUE, "model", "modelname"); in upsdrv_makevartable() 194 addvar(VAR_VALUE, "serial", "serialnumber"); in upsdrv_makevartable() 195 addvar(VAR_VALUE, "protocol", "protocol to use [text|binary] (default: autodection)"); in upsdrv_makevartable()
|
H A D | genericups.c | 320 addvar(VAR_VALUE, "upstype", "Set UPS type (required)"); in upsdrv_makevartable() 321 addvar(VAR_VALUE, "mfr", "Override manufacturer name"); in upsdrv_makevartable() 322 addvar(VAR_VALUE, "model", "Override model name"); in upsdrv_makevartable() 323 addvar(VAR_VALUE, "serial", "Specify the serial number"); in upsdrv_makevartable() 324 addvar(VAR_VALUE, "CP", "Override cable power setting"); in upsdrv_makevartable() 325 addvar(VAR_VALUE, "OL", "Override on line signal"); in upsdrv_makevartable() 326 addvar(VAR_VALUE, "LB", "Override low battery signal"); in upsdrv_makevartable() 327 addvar(VAR_VALUE, "SD", "Override shutdown setting"); in upsdrv_makevartable() 328 addvar(VAR_VALUE, "sdtime", "Hold time for shutdown value (seconds)"); in upsdrv_makevartable()
|
H A D | clone.c | 536 addvar(VAR_VALUE, "offdelay", "Delay before outlet shutdown (seconds)"); in upsdrv_makevartable() 537 addvar(VAR_VALUE, "ondelay", "Delay before outlet startup (seconds)"); in upsdrv_makevartable() 539 addvar(VAR_VALUE, "mincharge", "Remaining battery level when UPS switches to LB (percent)"); in upsdrv_makevartable() 540 addvar(VAR_VALUE, "minruntime", "Remaining battery runtime when UPS switches to LB (seconds)"); in upsdrv_makevartable() 542 addvar(VAR_VALUE, "load.off", "Command to switch off outlet"); in upsdrv_makevartable() 543 addvar(VAR_VALUE, "load.on", "Command to switch on outlet"); in upsdrv_makevartable() 544 addvar(VAR_VALUE, "load.status", "Variable that indicates outlet is on/off"); in upsdrv_makevartable()
|
H A D | libusb.c | 58 addvar(VAR_VALUE, "vendor", "Regular expression to match UPS Manufacturer string"); in nut_usb_addvars() 59 addvar(VAR_VALUE, "product", "Regular expression to match UPS Product string"); in nut_usb_addvars() 60 addvar(VAR_VALUE, "serial", "Regular expression to match UPS Serial number"); in nut_usb_addvars() 62 …addvar(VAR_VALUE, "vendorid", "Regular expression to match UPS Manufacturer numerical ID (4 digits… in nut_usb_addvars() 63 …addvar(VAR_VALUE, "productid", "Regular expression to match UPS Product numerical ID (4 digits hex… in nut_usb_addvars() 65 addvar(VAR_VALUE, "bus", "Regular expression to match USB bus name"); in nut_usb_addvars() 66 …addvar(VAR_VALUE, "usb_set_altinterface", "Force redundant call to usb_set_altinterface() (value=b… in nut_usb_addvars()
|
H A D | safenet.c | 457 addvar(VAR_VALUE, "manufacturer", "manufacturer [unknown]"); in upsdrv_makevartable() 458 addvar(VAR_VALUE, "modelname", "modelname [unknown]"); in upsdrv_makevartable() 459 addvar(VAR_VALUE, "serialnumber", "serialnumber [unknown]"); in upsdrv_makevartable() 461 addvar(VAR_VALUE, "ondelay", "Delay before UPS startup (minutes)"); in upsdrv_makevartable() 462 addvar(VAR_VALUE, "offdelay", "Delay before UPS shutdown (seconds)"); in upsdrv_makevartable()
|
H A D | powercom.c | 1141 addvar(VAR_VALUE, "type", in upsdrv_makevartable() 1144 addvar(VAR_VALUE, "manufacturer", in upsdrv_makevartable() 1146 addvar(VAR_VALUE, "modelname", in upsdrv_makevartable() 1148 addvar(VAR_VALUE, "serialnumber", in upsdrv_makevartable() 1150 addvar(VAR_VALUE, "shutdownArguments", in upsdrv_makevartable() 1152 addvar(VAR_VALUE, "linevoltage", in upsdrv_makevartable() 1154 addvar(VAR_VALUE, "numOfBytesFromUPS", in upsdrv_makevartable() 1158 addvar(VAR_VALUE, "validationSequence", in upsdrv_makevartable() 1161 addvar(VAR_VALUE, "frequency", in upsdrv_makevartable() 1163 addvar(VAR_VALUE, "loadPercentage", in upsdrv_makevartable() [all …]
|
H A D | blazer.c | 515 addvar(VAR_VALUE, "ondelay", "Delay before UPS startup (minutes)"); in blazer_makevartable() 516 addvar(VAR_VALUE, "offdelay", "Delay before UPS shutdown (seconds)"); in blazer_makevartable() 518 addvar(VAR_VALUE, "runtimecal", "Parameters used for runtime calculation"); in blazer_makevartable() 519 addvar(VAR_VALUE, "chargetime", "Nominal charge time for UPS battery"); in blazer_makevartable() 520 addvar(VAR_VALUE, "idleload", "Minimum load to be used for runtime calculation"); in blazer_makevartable() 522 addvar(VAR_FLAG, "norating", "Skip reading rating information from UPS"); in blazer_makevartable() 523 addvar(VAR_FLAG, "novendor", "Skip reading vendor information from UPS"); in blazer_makevartable() 525 addvar(VAR_FLAG, "protocol", "Preselect communication protocol (skip autodetection)"); in blazer_makevartable()
|
/dports/math/R-cran-survey/survey/R/ |
H A D | svypredmeans.R | 29 addvar<-t(dg_deta)%*%vcov(model)%*%dg_deta globalVar 30 vv<-addvar+attr(cond,"var") 31 attr(vv,"parts")<-list(addvar,attr(cond,"var"))
|
/dports/math/R-cran-lava/lava/R/ |
H A D | addvar.R | 9 `addvar` <- 13 `addvar<-` <- 18 `addvar<-.lvm` <- function(x,...,value) { 23 addvar(x, var=value, ...)
|