/dports/lang/zig/zig-0.9.0/lib/libc/include/any-windows-any/ |
H A D | mtxadmin.h | 192 virtual HRESULT WINAPI get_Value(BSTR bstrPropName,VARIANT *retval) = 0; 193 virtual HRESULT WINAPI put_Value(BSTR bstrPropName,VARIANT val) = 0; 196 virtual HRESULT WINAPI IsPropertyReadOnly(BSTR bstrPropName,VARIANT_BOOL *retval) = 0; 198 virtual HRESULT WINAPI IsPropertyWriteOnly(BSTR bstrPropName,VARIANT_BOOL *retval) = 0; 210 HRESULT (WINAPI *get_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT *retval); 211 HRESULT (WINAPI *put_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT val); 230 #define ICatalogObject_get_Value(This,bstrPropName,retval) (This)->lpVtbl->get_Value(This,bstrPropN… argument 231 #define ICatalogObject_put_Value(This,bstrPropName,val) (This)->lpVtbl->put_Value(This,bstrPropName… argument 234 … ICatalogObject_IsPropertyReadOnly(This,bstrPropName,retval) (This)->lpVtbl->IsPropertyReadOnly(Th… argument 236 …CatalogObject_IsPropertyWriteOnly(This,bstrPropName,retval) (This)->lpVtbl->IsPropertyWriteOnly(Th… argument [all …]
|
H A D | comadmin.h | 1611 BSTR bstrPropName, 1615 BSTR bstrPropName, 1625 BSTR bstrPropName, 1632 BSTR bstrPropName, 1688 BSTR bstrPropName, 1693 BSTR bstrPropName, 1706 BSTR bstrPropName, 1715 BSTR bstrPropName, 1737 #define ICatalogObject_get_Value(This,bstrPropName,pvarRetVal) (This)->lpVtbl->get_Value(This,bstrP… 1738 #define ICatalogObject_put_Value(This,bstrPropName,val) (This)->lpVtbl->put_Value(This,bstrPropName… [all …]
|
H A D | shldisp.h | 1863 BSTR bstrPropName, 1993 BSTR bstrPropName, 2034 …define FolderItem2_ExtendedProperty(This,bstrPropName,pvRet) (This)->lpVtbl->ExtendedProperty(This… 2115 static FORCEINLINE HRESULT FolderItem2_ExtendedProperty(FolderItem2* This,BSTR bstrPropName,VARIANT… 2116 return This->lpVtbl->ExtendedProperty(This,bstrPropName,pvRet);
|
H A D | comsvcs.h | 2262 …virtual HRESULT WINAPI EngineDefined(BSTR bstrPropName,VARIANT *varPropValue,BSTR bstrClsidEng) = … 2272 …HRESULT (WINAPI *EngineDefined)(ILBEvents *This,BSTR bstrPropName,VARIANT *varPropValue,BSTR bstrC… 2284 …ine ILBEvents_EngineDefined(This,bstrPropName,varPropValue,bstrClsidEng) (This)->lpVtbl->EngineDef… argument 2291 …HRESULT WINAPI ILBEvents_EngineDefined_Proxy(ILBEvents *This,BSTR bstrPropName,VARIANT *varPropVal…
|
/dports/lang/zig-devel/zig-0.9.0/lib/libc/include/any-windows-any/ |
H A D | mtxadmin.h | 192 virtual HRESULT WINAPI get_Value(BSTR bstrPropName,VARIANT *retval) = 0; 193 virtual HRESULT WINAPI put_Value(BSTR bstrPropName,VARIANT val) = 0; 196 virtual HRESULT WINAPI IsPropertyReadOnly(BSTR bstrPropName,VARIANT_BOOL *retval) = 0; 198 virtual HRESULT WINAPI IsPropertyWriteOnly(BSTR bstrPropName,VARIANT_BOOL *retval) = 0; 210 HRESULT (WINAPI *get_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT *retval); 211 HRESULT (WINAPI *put_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT val); 230 #define ICatalogObject_get_Value(This,bstrPropName,retval) (This)->lpVtbl->get_Value(This,bstrPropN… argument 231 #define ICatalogObject_put_Value(This,bstrPropName,val) (This)->lpVtbl->put_Value(This,bstrPropName… argument 234 … ICatalogObject_IsPropertyReadOnly(This,bstrPropName,retval) (This)->lpVtbl->IsPropertyReadOnly(Th… argument 236 …CatalogObject_IsPropertyWriteOnly(This,bstrPropName,retval) (This)->lpVtbl->IsPropertyWriteOnly(Th… argument [all …]
|
H A D | comadmin.h | 1611 BSTR bstrPropName, 1615 BSTR bstrPropName, 1625 BSTR bstrPropName, 1632 BSTR bstrPropName, 1688 BSTR bstrPropName, 1693 BSTR bstrPropName, 1706 BSTR bstrPropName, 1715 BSTR bstrPropName, 1737 #define ICatalogObject_get_Value(This,bstrPropName,pvarRetVal) (This)->lpVtbl->get_Value(This,bstrP… 1738 #define ICatalogObject_put_Value(This,bstrPropName,val) (This)->lpVtbl->put_Value(This,bstrPropName… [all …]
|
H A D | shldisp.h | 1863 BSTR bstrPropName, 1993 BSTR bstrPropName, 2034 …define FolderItem2_ExtendedProperty(This,bstrPropName,pvRet) (This)->lpVtbl->ExtendedProperty(This… 2115 static FORCEINLINE HRESULT FolderItem2_ExtendedProperty(FolderItem2* This,BSTR bstrPropName,VARIANT… 2116 return This->lpVtbl->ExtendedProperty(This,bstrPropName,pvRet);
|
H A D | comsvcs.h | 2262 …virtual HRESULT WINAPI EngineDefined(BSTR bstrPropName,VARIANT *varPropValue,BSTR bstrClsidEng) = … 2272 …HRESULT (WINAPI *EngineDefined)(ILBEvents *This,BSTR bstrPropName,VARIANT *varPropValue,BSTR bstrC… 2284 …ine ILBEvents_EngineDefined(This,bstrPropName,varPropValue,bstrClsidEng) (This)->lpVtbl->EngineDef… argument 2291 …HRESULT WINAPI ILBEvents_EngineDefined_Proxy(ILBEvents *This,BSTR bstrPropName,VARIANT *varPropVal…
|
/dports/net-mgmt/nagios-check_bacula9/bacula-9.6.7/src/win32/filed/plugins/ |
H A D | comadmin.h | 509 virtual HRESULT WINAPI get_Value(BSTR bstrPropName,VARIANT *pvarRetVal) = 0; 510 virtual HRESULT WINAPI put_Value(BSTR bstrPropName,VARIANT val) = 0; 513 virtual HRESULT WINAPI IsPropertyReadOnly(BSTR bstrPropName,VARIANT_BOOL *pbRetVal) = 0; 515 virtual HRESULT WINAPI IsPropertyWriteOnly(BSTR bstrPropName,VARIANT_BOOL *pbRetVal) = 0; 527 HRESULT (WINAPI *get_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT *pvarRetVal); 528 HRESULT (WINAPI *put_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT val); 547 #define ICatalogObject_get_Value(This,bstrPropName,pvarRetVal) (This)->lpVtbl->get_Value(This,bstrP… argument 548 #define ICatalogObject_put_Value(This,bstrPropName,val) (This)->lpVtbl->put_Value(This,bstrPropName… argument 551 …ICatalogObject_IsPropertyReadOnly(This,bstrPropName,pbRetVal) (This)->lpVtbl->IsPropertyReadOnly(T… argument 553 …atalogObject_IsPropertyWriteOnly(This,bstrPropName,pbRetVal) (This)->lpVtbl->IsPropertyWriteOnly(T… argument [all …]
|
/dports/net-mgmt/nagios-check_bacula11/bacula-11.0.5/src/win32/filed/plugins/ |
H A D | comadmin.h | 509 virtual HRESULT WINAPI get_Value(BSTR bstrPropName,VARIANT *pvarRetVal) = 0; 510 virtual HRESULT WINAPI put_Value(BSTR bstrPropName,VARIANT val) = 0; 513 virtual HRESULT WINAPI IsPropertyReadOnly(BSTR bstrPropName,VARIANT_BOOL *pbRetVal) = 0; 515 virtual HRESULT WINAPI IsPropertyWriteOnly(BSTR bstrPropName,VARIANT_BOOL *pbRetVal) = 0; 527 HRESULT (WINAPI *get_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT *pvarRetVal); 528 HRESULT (WINAPI *put_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT val); 547 #define ICatalogObject_get_Value(This,bstrPropName,pvarRetVal) (This)->lpVtbl->get_Value(This,bstrP… argument 548 #define ICatalogObject_put_Value(This,bstrPropName,val) (This)->lpVtbl->put_Value(This,bstrPropName… argument 551 …ICatalogObject_IsPropertyReadOnly(This,bstrPropName,pbRetVal) (This)->lpVtbl->IsPropertyReadOnly(T… argument 553 …atalogObject_IsPropertyWriteOnly(This,bstrPropName,pbRetVal) (This)->lpVtbl->IsPropertyWriteOnly(T… argument [all …]
|
/dports/sysutils/bacula11-server/bacula-11.0.5/src/win32/filed/plugins/ |
H A D | comadmin.h | 509 virtual HRESULT WINAPI get_Value(BSTR bstrPropName,VARIANT *pvarRetVal) = 0; 510 virtual HRESULT WINAPI put_Value(BSTR bstrPropName,VARIANT val) = 0; 513 virtual HRESULT WINAPI IsPropertyReadOnly(BSTR bstrPropName,VARIANT_BOOL *pbRetVal) = 0; 515 virtual HRESULT WINAPI IsPropertyWriteOnly(BSTR bstrPropName,VARIANT_BOOL *pbRetVal) = 0; 527 HRESULT (WINAPI *get_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT *pvarRetVal); 528 HRESULT (WINAPI *put_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT val); 547 #define ICatalogObject_get_Value(This,bstrPropName,pvarRetVal) (This)->lpVtbl->get_Value(This,bstrP… argument 548 #define ICatalogObject_put_Value(This,bstrPropName,val) (This)->lpVtbl->put_Value(This,bstrPropName… argument 551 …ICatalogObject_IsPropertyReadOnly(This,bstrPropName,pbRetVal) (This)->lpVtbl->IsPropertyReadOnly(T… argument 553 …atalogObject_IsPropertyWriteOnly(This,bstrPropName,pbRetVal) (This)->lpVtbl->IsPropertyWriteOnly(T… argument [all …]
|
/dports/sysutils/bacula9-client-static/bacula-9.6.7/src/win32/filed/plugins/ |
H A D | comadmin.h | 509 virtual HRESULT WINAPI get_Value(BSTR bstrPropName,VARIANT *pvarRetVal) = 0; 510 virtual HRESULT WINAPI put_Value(BSTR bstrPropName,VARIANT val) = 0; 513 virtual HRESULT WINAPI IsPropertyReadOnly(BSTR bstrPropName,VARIANT_BOOL *pbRetVal) = 0; 515 virtual HRESULT WINAPI IsPropertyWriteOnly(BSTR bstrPropName,VARIANT_BOOL *pbRetVal) = 0; 527 HRESULT (WINAPI *get_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT *pvarRetVal); 528 HRESULT (WINAPI *put_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT val); 547 #define ICatalogObject_get_Value(This,bstrPropName,pvarRetVal) (This)->lpVtbl->get_Value(This,bstrP… argument 548 #define ICatalogObject_put_Value(This,bstrPropName,val) (This)->lpVtbl->put_Value(This,bstrPropName… argument 551 …ICatalogObject_IsPropertyReadOnly(This,bstrPropName,pbRetVal) (This)->lpVtbl->IsPropertyReadOnly(T… argument 553 …atalogObject_IsPropertyWriteOnly(This,bstrPropName,pbRetVal) (This)->lpVtbl->IsPropertyWriteOnly(T… argument [all …]
|
/dports/sysutils/bacula11-client-static/bacula-11.0.5/src/win32/filed/plugins/ |
H A D | comadmin.h | 509 virtual HRESULT WINAPI get_Value(BSTR bstrPropName,VARIANT *pvarRetVal) = 0; 510 virtual HRESULT WINAPI put_Value(BSTR bstrPropName,VARIANT val) = 0; 513 virtual HRESULT WINAPI IsPropertyReadOnly(BSTR bstrPropName,VARIANT_BOOL *pbRetVal) = 0; 515 virtual HRESULT WINAPI IsPropertyWriteOnly(BSTR bstrPropName,VARIANT_BOOL *pbRetVal) = 0; 527 HRESULT (WINAPI *get_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT *pvarRetVal); 528 HRESULT (WINAPI *put_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT val); 547 #define ICatalogObject_get_Value(This,bstrPropName,pvarRetVal) (This)->lpVtbl->get_Value(This,bstrP… argument 548 #define ICatalogObject_put_Value(This,bstrPropName,val) (This)->lpVtbl->put_Value(This,bstrPropName… argument 551 …ICatalogObject_IsPropertyReadOnly(This,bstrPropName,pbRetVal) (This)->lpVtbl->IsPropertyReadOnly(T… argument 553 …atalogObject_IsPropertyWriteOnly(This,bstrPropName,pbRetVal) (This)->lpVtbl->IsPropertyWriteOnly(T… argument [all …]
|
/dports/sysutils/bacula9-client/bacula-9.6.7/src/win32/filed/plugins/ |
H A D | comadmin.h | 509 virtual HRESULT WINAPI get_Value(BSTR bstrPropName,VARIANT *pvarRetVal) = 0; 510 virtual HRESULT WINAPI put_Value(BSTR bstrPropName,VARIANT val) = 0; 513 virtual HRESULT WINAPI IsPropertyReadOnly(BSTR bstrPropName,VARIANT_BOOL *pbRetVal) = 0; 515 virtual HRESULT WINAPI IsPropertyWriteOnly(BSTR bstrPropName,VARIANT_BOOL *pbRetVal) = 0; 527 HRESULT (WINAPI *get_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT *pvarRetVal); 528 HRESULT (WINAPI *put_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT val); 547 #define ICatalogObject_get_Value(This,bstrPropName,pvarRetVal) (This)->lpVtbl->get_Value(This,bstrP… argument 548 #define ICatalogObject_put_Value(This,bstrPropName,val) (This)->lpVtbl->put_Value(This,bstrPropName… argument 551 …ICatalogObject_IsPropertyReadOnly(This,bstrPropName,pbRetVal) (This)->lpVtbl->IsPropertyReadOnly(T… argument 553 …atalogObject_IsPropertyWriteOnly(This,bstrPropName,pbRetVal) (This)->lpVtbl->IsPropertyWriteOnly(T… argument [all …]
|
/dports/sysutils/bacula9-server/bacula-9.6.7/src/win32/filed/plugins/ |
H A D | comadmin.h | 509 virtual HRESULT WINAPI get_Value(BSTR bstrPropName,VARIANT *pvarRetVal) = 0; 510 virtual HRESULT WINAPI put_Value(BSTR bstrPropName,VARIANT val) = 0; 513 virtual HRESULT WINAPI IsPropertyReadOnly(BSTR bstrPropName,VARIANT_BOOL *pbRetVal) = 0; 515 virtual HRESULT WINAPI IsPropertyWriteOnly(BSTR bstrPropName,VARIANT_BOOL *pbRetVal) = 0; 527 HRESULT (WINAPI *get_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT *pvarRetVal); 528 HRESULT (WINAPI *put_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT val); 547 #define ICatalogObject_get_Value(This,bstrPropName,pvarRetVal) (This)->lpVtbl->get_Value(This,bstrP… argument 548 #define ICatalogObject_put_Value(This,bstrPropName,val) (This)->lpVtbl->put_Value(This,bstrPropName… argument 551 …ICatalogObject_IsPropertyReadOnly(This,bstrPropName,pbRetVal) (This)->lpVtbl->IsPropertyReadOnly(T… argument 553 …atalogObject_IsPropertyWriteOnly(This,bstrPropName,pbRetVal) (This)->lpVtbl->IsPropertyWriteOnly(T… argument [all …]
|
/dports/sysutils/bacula11-client/bacula-11.0.5/src/win32/filed/plugins/ |
H A D | comadmin.h | 509 virtual HRESULT WINAPI get_Value(BSTR bstrPropName,VARIANT *pvarRetVal) = 0; 510 virtual HRESULT WINAPI put_Value(BSTR bstrPropName,VARIANT val) = 0; 513 virtual HRESULT WINAPI IsPropertyReadOnly(BSTR bstrPropName,VARIANT_BOOL *pbRetVal) = 0; 515 virtual HRESULT WINAPI IsPropertyWriteOnly(BSTR bstrPropName,VARIANT_BOOL *pbRetVal) = 0; 527 HRESULT (WINAPI *get_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT *pvarRetVal); 528 HRESULT (WINAPI *put_Value)(ICatalogObject *This,BSTR bstrPropName,VARIANT val); 547 #define ICatalogObject_get_Value(This,bstrPropName,pvarRetVal) (This)->lpVtbl->get_Value(This,bstrP… argument 548 #define ICatalogObject_put_Value(This,bstrPropName,val) (This)->lpVtbl->put_Value(This,bstrPropName… argument 551 …ICatalogObject_IsPropertyReadOnly(This,bstrPropName,pbRetVal) (This)->lpVtbl->IsPropertyReadOnly(T… argument 553 …atalogObject_IsPropertyWriteOnly(This,bstrPropName,pbRetVal) (This)->lpVtbl->IsPropertyWriteOnly(T… argument [all …]
|
/dports/lang/mono/mono-5.10.1.57/mcs/class/referencesource/System.ServiceModel/System/ServiceModel/ComIntegration/ |
H A D | AdminSDK.cs | 329 bool IsPropertyReadOnly([In, MarshalAs(UnmanagedType.BStr)] String bstrPropName); in IsPropertyReadOnly() argument 340 bool IsPropertyWriteOnly([In, MarshalAs(UnmanagedType.BStr)] String bstrPropName); in IsPropertyWriteOnly() argument
|