/freebsd/sys/contrib/device-tree/Bindings/power/supply/ |
H A D | ingenic,battery.yaml | 8 title: Ingenic JZ47xx battery 18 - const: ingenic,jz4740-battery 21 - ingenic,jz4725b-battery 22 - ingenic,jz4770-battery 23 - const: ingenic,jz4740-battery 29 const: battery 31 monitored-battery: 42 - monitored-battery 50 simple_battery: battery { 56 ingenic-battery { [all …]
|
H A D | battery.yaml | 13 The devicetree battery node provides static battery characteristics. 18 Upstream dts files should not include battery nodes, unless the battery 32 const: simple-battery 55 description: drained battery voltage 61 description: battery design energy 64 description: battery design capacity 130 of the battery and corresponding battery capacity percent, which is used 148 battery: battery { 149 compatible = "simple-battery"; 177 monitored-battery = <&battery>; [all …]
|
H A D | ingenic,battery.txt | 1 * Ingenic JZ47xx battery bindings 5 - compatible: Must be "ingenic,jz4740-battery". 8 - monitored-battery: phandle to a "simple-battery" compatible node. 11 described in battery.txt, with the following properties being required: 13 - voltage-min-design-microvolt: Drained battery voltage. 14 - voltage-max-design-microvolt: Fully charged battery voltage. 20 simple_battery: battery { 21 compatible = "simple-battery"; 27 compatible = "ingenic,jz4740-battery"; 29 io-channel-names = "battery"; [all …]
|
H A D | adc-battery.yaml | 4 $id: http://devicetree.org/schemas/power/supply/adc-battery.yaml# 7 title: ADC battery 13 Basic battery capacity meter, which only reports basic battery data 14 via ADC channels and optionally indicate that the battery is full by 19 monitor the current/power flowing out of the battery. Last but not 20 least the temperature channel is supposed to measure the battery 28 const: adc-battery 48 monitored-battery: true 54 - monitored-battery 63 compatible = "adc-battery"; [all …]
|
H A D | charger-manager.txt | 8 - cm-fuel-gauge : name of battery fuel gauge 20 - cm-name : charger manager's name (default : "battery") 25 - cm-battery-stat : battery status - 0 for battery always present, 1 for no 29 - cm-fullbatt-voltage : voltage (in uV) of full battery 33 - cm-battery-* : threshold battery temperature for charging 49 cm-name = "battery"; 57 cm-battery-stat = <3>; 65 cm-battery-cold = <50>; 66 cm-battery-cold-in-minus; 67 cm-battery-hot = <800>; [all …]
|
H A D | cpcap-battery.yaml | 8 title: Motorola CPCAP PMIC battery 24 const: motorola,cpcap-battery 29 - description: low battery percentage interrupt 30 - description: critical battery percentage interrupt 32 - description: battery detect interrupt 46 - description: battery temperature 47 - description: battery voltage 48 - description: battery charge current 49 - description: battery current 73 battery { [all …]
|
H A D | samsung,battery.yaml | 4 $id: http://devicetree.org/schemas/power/supply/samsung,battery.yaml# 16 the physical restrictions make it impossible to use another battery with the 25 description: 3.8V 1500 mAh battery used in Samsung GT-I8190 27 description: 3.8V 1500 mAh battery used in Samsung SGH-T599 and SGH-I407 29 description: 3.8V 1500 mAh battery used in Samsung GT-I8160 31 description: 3.8V 1700 mAh battery used in Samsung GT-S7710 33 description: 3.8V 1500 mAh battery used in Samsung GT-I9070 35 description: 3.8V 2000 mAh battery used in Samsung GT-I8530 48 battery: battery { 54 monitored-battery = <&battery>;
|
H A D | stericsson,ab8500-battery.txt | 2 information about the battery connected to the PMIC. 8 A boolean value indicating thermistor interface to battery 11 'btemp' and 'batctrl' are the pins interfaced for battery temperature 13 coefficient) resister is interfaced external to battery whereas 14 'batctrl' pin is used when NTC resister is internal to battery. 20 indicates: NTC resister is internal to battery, 'batctrl' is used 24 NTC resister is external to battery and 'btemp' signal is used 27 battery-type: 28 This shall be the battery manufacturing technology type, 33 stericsson,battery-type = "LIPO";
|
H A D | charger-manager.yaml | 34 default: battery 51 cm-battery-stat: 52 description: battery status 56 - 1 # no battery 91 cm-battery-cold: 95 cm-battery-cold-in-minus: 99 cm-battery-hot: 103 cm-battery-temp-diff: 176 cm-name = "battery"; 184 cm-battery-stat = <3>; [all …]
|
H A D | axp20x_battery.txt | 1 AXP20x and AXP22x battery power supply 5 "x-powers,axp209-battery-power-supply" 6 "x-powers,axp221-battery-power-supply" 7 "x-powers,axp813-battery-power-supply" 11 The supported devices can read the battery voltage, charge and discharge 12 currents of the battery by reading ADC channels from the ADC. 17 battery_power_supply: battery-power-supply { 18 compatible = "x-powers,axp209-battery-power-supply";
|
H A D | lego,ev3-battery.yaml | 4 $id: http://devicetree.org/schemas/power/supply/lego,ev3-battery.yaml# 14 LEGO MINDSTORMS EV3 has some built-in capability for monitoring the battery. 15 It uses 6 AA batteries or a special Li-ion rechargeable battery pack that is 16 detected by a key switch in the battery compartment. 23 const: lego,ev3-battery 27 - description: ADC channel for battery voltage 28 - description: ADC channel for battery current 37 description: Rechargeable battery indication gpio 50 battery { 51 compatible = "lego,ev3-battery";
|
H A D | x-powers,axp20x-battery-power-supply.yaml | 4 $id: http://devicetree.org/schemas/power/supply/x-powers,axp20x-battery-power-supply.yaml# 10 The supported devices can read the battery voltage, charge and discharge 11 currents of the battery by reading ADC channels from the ADC. 23 - const: x-powers,axp202-battery-power-supply 24 - const: x-powers,axp209-battery-power-supply 25 - const: x-powers,axp221-battery-power-supply 27 - const: x-powers,axp803-battery-power-supply 28 - const: x-powers,axp813-battery-power-supply 29 - const: x-powers,axp813-battery-power-supply
|
H A D | sbs,sbs-battery.yaml | 4 $id: http://devicetree.org/schemas/power/supply/sbs,sbs-battery.yaml# 7 title: SBS compliant battery 13 Battery compatible with the smart battery system specifications 27 - sbs,sbs-battery 29 - const: sbs,sbs-battery 47 sbs,battery-detect-gpios: 49 GPIO which signals battery detection. If this is not supplied, the bus 50 needs to be polled to detect the battery. 76 battery@b { 77 compatible = "ti,bq20z75", "sbs,sbs-battery"; [all …]
|
H A D | rx51-battery.txt | 1 Binding for Nokia N900 battery 3 The Nokia N900 battery status can be read via the TWL4030's A/D converter. 7 * "nokia,n900-battery" 12 * "bsi" - The ADC channel for battery size identification 13 * "vbat" - The ADC channel to measure the battery voltage 17 battery: n900-battery { 18 compatible = "nokia,n900-battery";
|
H A D | bq24190.yaml | 39 when power is connected and the battery is below minimum system voltage, 42 omit-battery-class: 46 battery device. 48 monitored-battery: 51 phandle to a "simple-battery" compatible node. 54 in battery.yaml, with the following properties being required: 56 (typically 20% of battery capacity). 59 setting (typically 10% of battery capacity). 73 bat: battery { 74 compatible = "simple-battery"; [all …]
|
H A D | sbs,sbs-manager.yaml | 66 batman: battery-manager@a { 80 battery@b { 81 compatible = "ti,bq20z65", "sbs,sbs-battery"; 83 sbs,battery-detect-gpios = <&batman 1 1>; 92 battery@b { 93 compatible = "ti,bq20z65", "sbs,sbs-battery"; 95 sbs,battery-detect-gpios = <&batman 2 1>; 104 battery@b { 105 compatible = "ti,bq20z65", "sbs,sbs-battery"; 107 sbs,battery-detect-gpios = <&batman 3 1>;
|
H A D | bq24190.txt | 13 - monitored-battery: phandle of battery characteristics devicetree node 14 The charger uses the following battery properties: 16 phase (typically 20% of battery capacity). 18 battery voltage is above recharge threshold, and the current is below 19 this setting (typically 10% of battery capacity). 20 See also Documentation/devicetree/bindings/power/supply/battery.txt 21 - ti,system-minimum-microvolt: when power is connected and the battery is below 37 bat: battery { 38 compatible = "simple-battery"; 48 monitored-battery = <&bat>;
|
H A D | sc2731_charger.txt | 1 Spreadtrum SC2731 PMIC battery charger binding 9 - monitored-battery: phandle of battery characteristics devicetree node. 10 The charger uses the following battery properties: 13 See Documentation/devicetree/bindings/power/supply/battery.txt 17 bat: battery { 18 compatible = "simple-battery"; 38 monitored-battery = <&bat>;
|
H A D | rohm,bd99954.yaml | 16 secondary battery intended to be used in space-constraint equipment such 27 # The battery charging profile of BD99954. 30 # Curve (2) represents battery voltage. 69 # The charger uses the following battery properties 92 # when battery voltage exceeds this limit voltage (3 in above chart) 101 # to the point where the battery voltage drops below this limit 103 # battery is expected to be faulty if battery voltage exceeds this limit. 104 # Charger will then enter to a "battery faulty" -state 122 monitored-battery: 124 phandle of battery characteristics devicetree node [all …]
|
H A D | sbs,sbs-manager.txt | 16 four smart battery devices at address 0xb. The driver actually implements this 36 battery@b { 37 compatible = "ti,bq2060", "sbs,sbs-battery"; 39 sbs,battery-detect-gpios = <&batman 1 1>; 48 battery@b { 49 compatible = "ti,bq2060", "sbs,sbs-battery"; 51 sbs,battery-detect-gpios = <&batman 2 1>; 60 battery@b { 61 compatible = "ti,bq2060", "sbs,sbs-battery"; 63 sbs,battery-detect-gpios = <&batman 3 1>;
|
H A D | lego_ev3_battery.txt | 4 LEGO MINDSTORMS EV3 has some built-in capability for monitoring the battery. 5 It uses 6 AA batteries or a special Li-ion rechargeable battery pack that is 6 detected by a key switch in the battery compartment. 9 - compatible: Must be "lego,ev3-battery" 12 - rechargeable-gpios: phandle to the rechargeable battery indication gpio 16 battery { 17 compatible = "lego,ev3-battery";
|
H A D | sc27xx-fg.txt | 11 - battery-detect-gpios: GPIO for battery detection. 18 - monitored-battery: Phandle of battery characteristics devicetree node. 19 See Documentation/devicetree/bindings/power/supply/battery.txt 23 bat: battery { 24 compatible = "simple-battery"; 51 battery-detect-gpios = <&pmic_eic 9 GPIO_ACTIVE_HIGH>; 56 monitored-battery = <&bat>;
|
H A D | nokia,n900-battery.yaml | 4 $id: http://devicetree.org/schemas/power/supply/nokia,n900-battery.yaml# 7 title: Nokia N900 battery 18 const: nokia,n900-battery 23 - description: ADC channel for battery size identification 24 - description: ADC channel to measure the battery voltage 41 battery { 42 compatible = "nokia,n900-battery";
|
/freebsd/sys/contrib/device-tree/Bindings/power/supply/ab8500/ |
H A D | fg.txt | 10 main-charger, usb-combo-charger and battery-temperature-monitoring. 16 - battery = Shall be battery specific information 20 battery = <&ab8500_battery>; 27 'battery technology type' used. 31 A boolean value indicating thermistor interface to battery 36 coefficient) resister is interfaced external to battery whereas 37 'batctrl' pin is used when NTC resister is internal to battery. 47 NTC resister is external to battery and 'btemp' signal is used 50 battery-type: 51 This shall be the battery manufacturing technology type, [all …]
|
/freebsd/sys/contrib/device-tree/Bindings/rtc/ |
H A D | rtc-palmas.txt | 10 - ti,backup-battery-chargeable: The Palmas series device like TPS65913 or 11 TPS80036 supports the backup battery for powering the RTC when main 12 battery is removed or in very low power state. The backup battery 14 battery is chargeable or not. If charging battery then driver can 16 - ti,backup-battery-charge-high-current: Enable high current charging in 17 backup battery. Device supports the < 100uA and > 100uA charging. 19 charge battery to lower current i.e. < 100uA. 28 ti,backup-battery-chargeable; 29 ti,backup-battery-charge-high-current;
|