1-- File Name : PBI-MGSIGNALCHARACTERISTICS-MIB 2-- Date : Thu Sep 21 14:37:54 CST 2006 3-- Author : AdventNet Agent Toolkit Java Edition - MIB Editor 6 4 5 6 7PBI-MGSIGNALCHARACTERISTICS-MIB DEFINITIONS ::= BEGIN 8 IMPORTS 9 RowStatus, DisplayString 10 FROM SNMPv2-TC 11 DisplayString 12 FROM RFC1213-MIB 13 mg 14 FROM PBI-MAIN-MIB 15 MODULE-IDENTITY, enterprises, OBJECT-TYPE, Integer32 16 FROM SNMPv2-SMI; 17 18 mgSignalCharacteristics MODULE-IDENTITY 19 LAST-UPDATED "200609210924Z" 20 ORGANIZATION "Organization" 21 CONTACT-INFO "Contact-info" 22 DESCRIPTION "Description" 23 REVISION "200609210924Z" 24 DESCRIPTION "" 25 ::= { mg 2 } 26 27 tsOutTable OBJECT-TYPE 28 SYNTAX SEQUENCE OF TsOutEntry 29 MAX-ACCESS not-accessible 30 STATUS current 31 DESCRIPTION " " 32 ::= { mgSignalCharacteristics 1 } 33 34 mgPATTable OBJECT-TYPE 35 SYNTAX SEQUENCE OF MgPATEntry 36 MAX-ACCESS not-accessible 37 STATUS current 38 DESCRIPTION "PSI/SI information relating to the PAT, reference ISO/IEC 13818-1 " 39 ::= { mgSignalCharacteristics 2 } 40 41 mgPMTTable OBJECT-TYPE 42 SYNTAX SEQUENCE OF MgPMTEntry 43 MAX-ACCESS not-accessible 44 STATUS current 45 DESCRIPTION "PSI/SI information relating to the PMT" 46 ::= { mgSignalCharacteristics 3 } 47 48 mgNITTable OBJECT-TYPE 49 SYNTAX SEQUENCE OF MgNITEntry 50 MAX-ACCESS not-accessible 51 STATUS current 52 DESCRIPTION "PSI/SI information relating to the NIT" 53 ::= { mgSignalCharacteristics 4 } 54 55 mgSDTTable OBJECT-TYPE 56 SYNTAX SEQUENCE OF MgSDTEntry 57 MAX-ACCESS not-accessible 58 STATUS current 59 DESCRIPTION "PSI/SI information relating to the SDT, reference DVB 300-468" 60 ::= { mgSignalCharacteristics 5 } 61 62 mgFilterTable OBJECT-TYPE 63 SYNTAX SEQUENCE OF MgFilterEntry 64 MAX-ACCESS not-accessible 65 STATUS current 66 DESCRIPTION "Description" 67 ::= { mgSignalCharacteristics 6 } 68 69 mgCATTable OBJECT-TYPE 70 SYNTAX SEQUENCE OF MgCATEntry 71 MAX-ACCESS not-accessible 72 STATUS current 73 DESCRIPTION "PSI/SI information relating to the CAT, reference ISO/IEC 13818-1 " 74 ::= { mgSignalCharacteristics 7 } 75 76 tsInput OBJECT IDENTIFIER 77 ::= { mgSignalCharacteristics 8 } 78 79 mgBATTable OBJECT-TYPE 80 SYNTAX SEQUENCE OF MgBATEntry 81 MAX-ACCESS not-accessible 82 STATUS current 83 DESCRIPTION " PSI/SI information relating to the BAT, reference ISO/IEC 13818-1 " 84 ::= { mgSignalCharacteristics 9 } 85 86 tsOutEntry OBJECT-TYPE 87 SYNTAX TsOutEntry 88 MAX-ACCESS not-accessible 89 STATUS current 90 DESCRIPTION " Row Description " 91 INDEX { channelOutput } 92 ::= { tsOutTable 1 } 93 94 TsOutEntry ::= SEQUENCE { 95 channelOutput INTEGER, 96 bitRate INTEGER, 97 packetSize INTEGER, 98 transportStreamID INTEGER, 99 otiginalNetworkID INTEGER, 100 networkID INTEGER, 101 bitrateThreshosdPercent INTEGER, 102 outValidBitRate INTEGER 103 } 104 105 channelOutput OBJECT-TYPE 106 SYNTAX INTEGER 107 MAX-ACCESS read-write 108 STATUS current 109 DESCRIPTION "output channel number" 110 ::= { tsOutEntry 1 } 111 112 bitRate OBJECT-TYPE 113 SYNTAX INTEGER 114 MAX-ACCESS read-write 115 STATUS current 116 DESCRIPTION "Transport stream output size, 3000EC: from 0 to 16Mpbs; 3000MX:from 0 to 100Mpbs; 3000TM: from 0 to 50Mpbs" 117 ::= { tsOutEntry 2 } 118 119 packetSize OBJECT-TYPE 120 SYNTAX INTEGER 121 MAX-ACCESS read-write 122 STATUS current 123 DESCRIPTION "Packet length, option: 188 or 204" 124 ::= { tsOutEntry 3 } 125 126 transportStreamID OBJECT-TYPE 127 SYNTAX INTEGER 128 MAX-ACCESS read-write 129 STATUS current 130 DESCRIPTION "The transport stream ID for this transport stream as read from the PAT, its value range: reference ISO/IEC 13818-1" 131 ::= { tsOutEntry 4 } 132 133 otiginalNetworkID OBJECT-TYPE 134 SYNTAX INTEGER 135 MAX-ACCESS read-write 136 STATUS current 137 DESCRIPTION "The original network ID for this transport stream as read from the NIT, its value range: reference DVB 300-468" 138 ::= { tsOutEntry 5 } 139 140 networkID OBJECT-TYPE 141 SYNTAX INTEGER 142 MAX-ACCESS read-write 143 STATUS current 144 DESCRIPTION "The network ID for this transport stream as read from the NIT, its value range: reference DVB 300-468" 145 ::= { tsOutEntry 6 } 146 147 bitrateThreshosdPercent OBJECT-TYPE 148 SYNTAX INTEGER 149 MAX-ACCESS read-write 150 STATUS current 151 DESCRIPTION "ts overflow percent value(0 - 100)" 152 ::= { tsOutEntry 7 } 153 154 outValidBitRate OBJECT-TYPE 155 SYNTAX INTEGER 156 MAX-ACCESS read-only 157 STATUS current 158 DESCRIPTION "transport stream out valid bit rate" 159 ::= { tsOutEntry 8 } 160 161 mgPATEntry OBJECT-TYPE 162 SYNTAX MgPATEntry 163 MAX-ACCESS not-accessible 164 STATUS current 165 DESCRIPTION "Row Description" 166 INDEX { channelInputPAT } 167 ::= { mgPATTable 1 } 168 169 MgPATEntry ::= SEQUENCE { 170 channelInputPAT INTEGER, 171 patSection DisplayString 172 } 173 174 channelInputPAT OBJECT-TYPE 175 SYNTAX INTEGER ( -2147483648 .. 2147483647 ) 176 MAX-ACCESS read-write 177 STATUS current 178 DESCRIPTION "The physical input on which this transport stream appears" 179 ::= { mgPATEntry 1 } 180 181 patSection OBJECT-TYPE 182 SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) 183 MAX-ACCESS read-write 184 STATUS current 185 DESCRIPTION "The transport stream Relating to the PAT seciton, reference ISO/IEC 13818-1 " 186 ::= { mgPATEntry 2 } 187 188 mgPMTEntry OBJECT-TYPE 189 SYNTAX MgPMTEntry 190 MAX-ACCESS not-accessible 191 STATUS current 192 DESCRIPTION "Row Description" 193 INDEX { channelInputPMT } 194 ::= { mgPMTTable 1 } 195 196 MgPMTEntry ::= SEQUENCE { 197 channelInputPMT INTEGER, 198 pmtProgramNumber INTEGER, 199 pmtPID INTEGER, 200 pmtSection DisplayString 201 } 202 203 channelInputPMT OBJECT-TYPE 204 SYNTAX INTEGER 205 MAX-ACCESS read-write 206 STATUS current 207 DESCRIPTION "The physical input on which this transport stream appears" 208 ::= { mgPMTEntry 1 } 209 210 pmtProgramNumber OBJECT-TYPE 211 SYNTAX INTEGER 212 MAX-ACCESS read-write 213 STATUS current 214 DESCRIPTION "The PMT program number as read from PMT,reference ISO/IEC 13818-1" 215 ::= { mgPMTEntry 2 } 216 217 pmtPID OBJECT-TYPE 218 SYNTAX INTEGER 219 MAX-ACCESS read-write 220 STATUS current 221 DESCRIPTION "The PMT PID as read from PMT,reference ISO/IEC 13818-1" 222 ::= { mgPMTEntry 3 } 223 224 pmtSection OBJECT-TYPE 225 SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) 226 MAX-ACCESS read-write 227 STATUS current 228 DESCRIPTION "The transport stream Relating to the PMT seciton, reference ISO/IEC 13818-1" 229 ::= { mgPMTEntry 4 } 230 231 mgNITEntry OBJECT-TYPE 232 SYNTAX MgNITEntry 233 MAX-ACCESS not-accessible 234 STATUS current 235 DESCRIPTION "Row Description" 236 INDEX { channelInputNIT } 237 ::= { mgNITTable 1 } 238 239 MgNITEntry ::= SEQUENCE { 240 channelInputNIT INTEGER, 241 networkType INTEGER, 242 nitActualSection DisplayString, 243 nitOhtersSection DisplayString 244 } 245 246 channelInputNIT OBJECT-TYPE 247 SYNTAX INTEGER 248 MAX-ACCESS read-write 249 STATUS current 250 DESCRIPTION "The physical input on which this transport stream appears" 251 ::= { mgNITEntry 1 } 252 253 networkType OBJECT-TYPE 254 SYNTAX INTEGER 255 MAX-ACCESS read-write 256 STATUS current 257 DESCRIPTION "The network type include two types: actual NIT and others NIT, reference DVB 300-468" 258 ::= { mgNITEntry 2 } 259 260 nitActualSection OBJECT-TYPE 261 SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) 262 MAX-ACCESS read-write 263 STATUS current 264 DESCRIPTION "Relating to the Actual section, its table ID is 0x40 in NIT,reference DVB 300-468" 265 ::= { mgNITEntry 3 } 266 267 nitOhtersSection OBJECT-TYPE 268 SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) 269 MAX-ACCESS read-write 270 STATUS current 271 DESCRIPTION "Relating to the others section , its table ID is 0x41 in NIT,reference DVB 300-468" 272 ::= { mgNITEntry 4 } 273 274 mgSDTEntry OBJECT-TYPE 275 SYNTAX MgSDTEntry 276 MAX-ACCESS not-accessible 277 STATUS current 278 DESCRIPTION "Row Description" 279 INDEX { channelInputSDT } 280 ::= { mgSDTTable 1 } 281 282 MgSDTEntry ::= SEQUENCE { 283 channelInputSDT INTEGER, 284 sdtSection DisplayString 285 } 286 287 channelInputSDT OBJECT-TYPE 288 SYNTAX INTEGER 289 MAX-ACCESS read-write 290 STATUS current 291 DESCRIPTION "The physical input on which this transport stream appears" 292 ::= { mgSDTEntry 1 } 293 294 sdtSection OBJECT-TYPE 295 SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) 296 MAX-ACCESS read-write 297 STATUS current 298 DESCRIPTION "The transport stream relating to SDT seciton, reference DVB 300-468" 299 ::= { mgSDTEntry 2 } 300 301 mgFilterEntry OBJECT-TYPE 302 SYNTAX MgFilterEntry 303 MAX-ACCESS not-accessible 304 STATUS current 305 DESCRIPTION "Row Description" 306 INDEX { channelInputFilter } 307 ::= { mgFilterTable 1 } 308 309 MgFilterEntry ::= SEQUENCE { 310 channelInputFilter INTEGER, 311 oldPID DisplayString, 312 newPID DisplayString, 313 oldProgramNumber DisplayString, 314 newProgramNumber DisplayString 315 } 316 317 channelInputFilter OBJECT-TYPE 318 SYNTAX INTEGER 319 MAX-ACCESS read-write 320 STATUS current 321 DESCRIPTION "The physical input on which this transport stream appears" 322 ::= { mgFilterEntry 1 } 323 324 oldPID OBJECT-TYPE 325 SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) 326 MAX-ACCESS read-write 327 STATUS current 328 DESCRIPTION "The old PID will be filtered output" 329 ::= { mgFilterEntry 2 } 330 331 newPID OBJECT-TYPE 332 SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) 333 MAX-ACCESS read-write 334 STATUS current 335 DESCRIPTION "The new PID is bulit according to old PID" 336 ::= { mgFilterEntry 3 } 337 338 oldProgramNumber OBJECT-TYPE 339 SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) 340 MAX-ACCESS read-write 341 STATUS current 342 DESCRIPTION "The old program number,they come from PAT and will be filtered output" 343 ::= { mgFilterEntry 4 } 344 345 newProgramNumber OBJECT-TYPE 346 SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) 347 MAX-ACCESS read-write 348 STATUS current 349 DESCRIPTION "The new program number, they are bulit and will be made a new PAT" 350 ::= { mgFilterEntry 5 } 351 352 mgCATEntry OBJECT-TYPE 353 SYNTAX MgCATEntry 354 MAX-ACCESS not-accessible 355 STATUS current 356 DESCRIPTION "Row Description" 357 INDEX { channelInputCAT } 358 ::= { mgCATTable 1 } 359 360 MgCATEntry ::= SEQUENCE { 361 channelInputCAT INTEGER, 362 catSection DisplayString 363 } 364 365 channelInputCAT OBJECT-TYPE 366 SYNTAX INTEGER ( -2147483648 .. 2147483647 ) 367 MAX-ACCESS read-write 368 STATUS current 369 DESCRIPTION "The physical input on which this transport stream appears" 370 ::= { mgCATEntry 1 } 371 372 catSection OBJECT-TYPE 373 SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) 374 MAX-ACCESS read-write 375 STATUS current 376 DESCRIPTION "The transport stream Relating to the CAT seciton, reference ISO/IEC 13818-1 " 377 ::= { mgCATEntry 2 } 378 379 channelInput OBJECT-TYPE 380 SYNTAX INTEGER 381 MAX-ACCESS read-write 382 STATUS current 383 DESCRIPTION "channel number of input" 384 ::= { tsInput 1 } 385 386 stateLock OBJECT-TYPE 387 SYNTAX INTEGER 388 MAX-ACCESS read-write 389 STATUS current 390 DESCRIPTION "0xFFFF is lock, other is unlock" 391 ::= { tsInput 2 } 392 393 tsIdPreference OBJECT-TYPE 394 SYNTAX INTEGER 395 MAX-ACCESS read-write 396 STATUS current 397 DESCRIPTION "transport stream identifier" 398 ::= { tsInput 3 } 399 400 mgBATEntry OBJECT-TYPE 401 SYNTAX MgBATEntry 402 MAX-ACCESS not-accessible 403 STATUS current 404 DESCRIPTION "Row Description" 405 INDEX { channelBAT } 406 ::= { mgBATTable 1 } 407 408 MgBATEntry ::= SEQUENCE { 409 channelBAT INTEGER, 410 batSection DisplayString 411 } 412 413 channelBAT OBJECT-TYPE 414 SYNTAX INTEGER 415 MAX-ACCESS read-write 416 STATUS current 417 DESCRIPTION "specify channel of get BAT " 418 ::= { mgBATEntry 1 } 419 420 batSection OBJECT-TYPE 421 SYNTAX DisplayString ( SIZE ( 0 .. 1024 ) ) 422 MAX-ACCESS read-write 423 STATUS current 424 DESCRIPTION "The transport stream Relating to the BAT seciton, reference ISO/IEC 13818-1 " 425 ::= { mgBATEntry 2 } 426 427END 428