1-- File Name : PBI-MGSIGNALCHARACTERISTICS-MIB
2-- Date      : Thu Sep 21 14:37:54 CST 2006
3-- Author    : AdventNet Agent Toolkit Java Edition - MIB Editor 6
4
5
6
7PBI-MGSIGNALCHARACTERISTICS-MIB	DEFINITIONS ::= BEGIN
8	IMPORTS
9		RowStatus, DisplayString
10			FROM SNMPv2-TC
11		DisplayString
12			FROM RFC1213-MIB
13		mg
14			FROM PBI-MAIN-MIB
15		MODULE-IDENTITY, enterprises, OBJECT-TYPE, Integer32
16			FROM SNMPv2-SMI;
17
18	mgSignalCharacteristics	MODULE-IDENTITY
19		LAST-UPDATED	"200609210924Z"
20		ORGANIZATION	"Organization"
21		CONTACT-INFO	"Contact-info"
22		DESCRIPTION		"Description"
23		REVISION			"200609210924Z"
24		DESCRIPTION		""
25		::=  {  mg  2  }
26
27	tsOutTable	OBJECT-TYPE
28		SYNTAX		SEQUENCE  OF  TsOutEntry
29		MAX-ACCESS	not-accessible
30		STATUS		current
31		DESCRIPTION	"  "
32		::=  { mgSignalCharacteristics  1 }
33
34	mgPATTable	OBJECT-TYPE
35		SYNTAX		SEQUENCE  OF  MgPATEntry
36		MAX-ACCESS	not-accessible
37		STATUS		current
38		DESCRIPTION	"PSI/SI information relating to the PAT, reference ISO/IEC 13818-1 "
39		::=  { mgSignalCharacteristics  2 }
40
41	mgPMTTable	OBJECT-TYPE
42		SYNTAX		SEQUENCE  OF  MgPMTEntry
43		MAX-ACCESS	not-accessible
44		STATUS		current
45		DESCRIPTION	"PSI/SI information relating to the PMT"
46		::=  { mgSignalCharacteristics  3 }
47
48	mgNITTable	OBJECT-TYPE
49		SYNTAX		SEQUENCE  OF  MgNITEntry
50		MAX-ACCESS	not-accessible
51		STATUS		current
52		DESCRIPTION	"PSI/SI information relating to the NIT"
53		::=  { mgSignalCharacteristics  4 }
54
55	mgSDTTable	OBJECT-TYPE
56		SYNTAX		SEQUENCE  OF  MgSDTEntry
57		MAX-ACCESS	not-accessible
58		STATUS		current
59		DESCRIPTION	"PSI/SI information relating to the SDT, reference DVB 300-468"
60		::=  { mgSignalCharacteristics  5 }
61
62	mgFilterTable	OBJECT-TYPE
63		SYNTAX		SEQUENCE  OF  MgFilterEntry
64		MAX-ACCESS	not-accessible
65		STATUS		current
66		DESCRIPTION	"Description"
67		::=  { mgSignalCharacteristics  6 }
68
69	mgCATTable	OBJECT-TYPE
70		SYNTAX		SEQUENCE  OF  MgCATEntry
71		MAX-ACCESS	not-accessible
72		STATUS		current
73		DESCRIPTION	"PSI/SI information relating to the CAT, reference ISO/IEC 13818-1 "
74		::=  { mgSignalCharacteristics  7 }
75
76	tsInput OBJECT IDENTIFIER
77		::=  { mgSignalCharacteristics  8 }
78
79	mgBATTable		OBJECT-TYPE
80		SYNTAX		SEQUENCE  OF  MgBATEntry
81		MAX-ACCESS	not-accessible
82		STATUS		current
83		DESCRIPTION	" PSI/SI information relating to the BAT, reference ISO/IEC 13818-1 "
84		::=  { mgSignalCharacteristics  9 }
85
86 	tsOutEntry	OBJECT-TYPE
87		SYNTAX		TsOutEntry
88		MAX-ACCESS	not-accessible
89		STATUS		current
90		DESCRIPTION	" Row Description "
91		INDEX		{  channelOutput  }
92		::=  { tsOutTable 1 }
93
94  TsOutEntry  ::=  SEQUENCE {
95	    channelOutput             INTEGER,
96	    bitRate 	                INTEGER,
97    	packetSize                INTEGER,
98    	transportStreamID         INTEGER,
99    	otiginalNetworkID         INTEGER,
100    	networkID 		            INTEGER,
101    	bitrateThreshosdPercent   INTEGER,
102    	outValidBitRate           INTEGER
103  }
104
105  channelOutput	OBJECT-TYPE
106		SYNTAX			INTEGER
107		MAX-ACCESS		read-write
108		STATUS			current
109		DESCRIPTION		"output channel number"
110		::=  {  tsOutEntry  1  }
111
112	bitRate	OBJECT-TYPE
113		SYNTAX			INTEGER
114		MAX-ACCESS		read-write
115		STATUS			current
116		DESCRIPTION		"Transport stream output size, 3000EC: from 0 to 16Mpbs; 3000MX:from 0 to 100Mpbs; 3000TM: from 0 to 50Mpbs"
117		::=  {  tsOutEntry  2  }
118
119	packetSize	OBJECT-TYPE
120		SYNTAX			INTEGER
121		MAX-ACCESS		read-write
122		STATUS			current
123		DESCRIPTION		"Packet length, option: 188 or 204"
124		::=  {  tsOutEntry  3  }
125
126	transportStreamID	OBJECT-TYPE
127		SYNTAX			INTEGER
128		MAX-ACCESS		read-write
129		STATUS			current
130		DESCRIPTION		"The transport stream ID for this transport stream as read from the PAT, its value range: reference ISO/IEC 13818-1"
131		::=  {  tsOutEntry  4  }
132
133	otiginalNetworkID	OBJECT-TYPE
134		SYNTAX			INTEGER
135		MAX-ACCESS		read-write
136		STATUS			current
137		DESCRIPTION		"The original network ID for this transport stream as read from the NIT, its value range: reference DVB 300-468"
138		::=  {  tsOutEntry  5  }
139
140	networkID	OBJECT-TYPE
141		SYNTAX			INTEGER
142		MAX-ACCESS		read-write
143		STATUS			current
144		DESCRIPTION		"The network ID for this transport stream as read from the NIT, its value range: reference DVB 300-468"
145		::=  {  tsOutEntry  6  }
146
147  bitrateThreshosdPercent	OBJECT-TYPE
148		SYNTAX			INTEGER
149		MAX-ACCESS		read-write
150		STATUS			current
151		DESCRIPTION		"ts overflow percent value(0 - 100)"
152		::=  {  tsOutEntry  7  }
153
154	outValidBitRate	OBJECT-TYPE
155		SYNTAX			INTEGER
156		MAX-ACCESS		read-only
157		STATUS			current
158		DESCRIPTION		"transport stream out valid bit rate"
159		::=  {  tsOutEntry  8  }
160
161	mgPATEntry	OBJECT-TYPE
162		SYNTAX		MgPATEntry
163		MAX-ACCESS	not-accessible
164		STATUS		current
165		DESCRIPTION	"Row Description"
166		INDEX		{  channelInputPAT  }
167		::=  { mgPATTable 1 }
168
169	MgPATEntry  ::=  SEQUENCE {
170		channelInputPAT  INTEGER,
171    patSection       DisplayString
172	}
173
174	channelInputPAT	OBJECT-TYPE
175		SYNTAX			INTEGER  ( -2147483648 .. 2147483647  )
176		MAX-ACCESS		read-write
177		STATUS			current
178		DESCRIPTION		"The physical input on which this transport stream appears"
179		::=  {  mgPATEntry  1  }
180
181  patSection	OBJECT-TYPE
182		SYNTAX			DisplayString  ( SIZE ( 0 .. 1024  ) )
183		MAX-ACCESS		read-write
184		STATUS			current
185		DESCRIPTION		"The transport stream Relating to the PAT seciton, reference ISO/IEC 13818-1 "
186		::=  {  mgPATEntry  2  }
187
188	mgPMTEntry	OBJECT-TYPE
189		SYNTAX		MgPMTEntry
190		MAX-ACCESS	not-accessible
191		STATUS		current
192		DESCRIPTION	"Row Description"
193		INDEX		{  channelInputPMT  }
194		::=  { mgPMTTable 1 }
195
196	MgPMTEntry  ::=  SEQUENCE {
197		channelInputPMT   INTEGER,
198		pmtProgramNumber  INTEGER,
199		pmtPID            INTEGER,
200		pmtSection        DisplayString
201	}
202
203	channelInputPMT	OBJECT-TYPE
204		SYNTAX			INTEGER
205		MAX-ACCESS		read-write
206		STATUS			current
207		DESCRIPTION		"The physical input on which this transport stream appears"
208		::=  {  mgPMTEntry  1  }
209
210	pmtProgramNumber	OBJECT-TYPE
211		SYNTAX			INTEGER
212		MAX-ACCESS		read-write
213		STATUS			current
214		DESCRIPTION		"The PMT program number as read from PMT,reference ISO/IEC 13818-1"
215		::=  {  mgPMTEntry  2  }
216
217	pmtPID	OBJECT-TYPE
218		SYNTAX			INTEGER
219		MAX-ACCESS		read-write
220		STATUS			current
221		DESCRIPTION		"The PMT PID as read from PMT,reference ISO/IEC 13818-1"
222		::=  {  mgPMTEntry  3  }
223
224  pmtSection	OBJECT-TYPE
225		SYNTAX			DisplayString  ( SIZE ( 0 .. 1024  ) )
226		MAX-ACCESS		read-write
227		STATUS			current
228		DESCRIPTION		"The transport stream Relating to the PMT seciton, reference ISO/IEC 13818-1"
229		::=  {  mgPMTEntry  4  }
230
231	mgNITEntry	OBJECT-TYPE
232		SYNTAX		MgNITEntry
233		MAX-ACCESS	not-accessible
234		STATUS		current
235		DESCRIPTION	"Row Description"
236		INDEX		{  channelInputNIT  }
237		::=  { mgNITTable 1 }
238
239	MgNITEntry  ::=  SEQUENCE {
240		channelInputNIT  INTEGER,
241		networkType      INTEGER,
242		nitActualSection       DisplayString,
243		nitOhtersSection       DisplayString
244	}
245
246  channelInputNIT  	OBJECT-TYPE
247		SYNTAX			INTEGER
248		MAX-ACCESS		read-write
249		STATUS			current
250		DESCRIPTION		"The physical input on which this transport stream appears"
251		::=  {  mgNITEntry  1  }
252
253  networkType  	OBJECT-TYPE
254		SYNTAX			INTEGER
255		MAX-ACCESS		read-write
256		STATUS			current
257		DESCRIPTION		"The network type include two types: actual NIT and others NIT,  reference DVB 300-468"
258		::=  {  mgNITEntry  2  }
259
260  nitActualSection	OBJECT-TYPE
261		SYNTAX			DisplayString  ( SIZE ( 0 .. 1024  ) )
262		MAX-ACCESS		read-write
263		STATUS			current
264		DESCRIPTION		"Relating to the Actual section, its table ID is 0x40 in NIT,reference DVB 300-468"
265		::=  {  mgNITEntry  3  }
266
267	nitOhtersSection	OBJECT-TYPE
268		SYNTAX			DisplayString  ( SIZE ( 0 .. 1024  ) )
269		MAX-ACCESS		read-write
270		STATUS			current
271		DESCRIPTION		"Relating to the others section , its table ID is 0x41 in NIT,reference DVB 300-468"
272		::=  {  mgNITEntry  4  }
273
274	mgSDTEntry	OBJECT-TYPE
275		SYNTAX		MgSDTEntry
276		MAX-ACCESS	not-accessible
277		STATUS		current
278		DESCRIPTION	"Row Description"
279		INDEX		{  channelInputSDT  }
280		::=  { mgSDTTable 1 }
281
282	MgSDTEntry  ::=  SEQUENCE {
283		channelInputSDT  INTEGER,
284		sdtSection       DisplayString
285	}
286
287	channelInputSDT	OBJECT-TYPE
288		SYNTAX			INTEGER
289		MAX-ACCESS		read-write
290		STATUS			current
291		DESCRIPTION		"The physical input on which this transport stream appears"
292		::=  {  mgSDTEntry  1  }
293
294  sdtSection	OBJECT-TYPE
295		SYNTAX			DisplayString  ( SIZE ( 0 .. 1024  ) )
296		MAX-ACCESS		read-write
297		STATUS			current
298		DESCRIPTION		"The transport stream relating to SDT seciton, reference DVB 300-468"
299		::=  {  mgSDTEntry  2  }
300
301	mgFilterEntry	OBJECT-TYPE
302		SYNTAX		MgFilterEntry
303		MAX-ACCESS	not-accessible
304		STATUS		current
305		DESCRIPTION	"Row Description"
306		INDEX		{  channelInputFilter  }
307		::=  { mgFilterTable 1 }
308
309	MgFilterEntry  ::=  SEQUENCE {
310		channelInputFilter  INTEGER,
311		oldPID              DisplayString,
312		newPID              DisplayString,
313		oldProgramNumber    DisplayString,
314		newProgramNumber    DisplayString
315	}
316
317	channelInputFilter	OBJECT-TYPE
318		SYNTAX			INTEGER
319		MAX-ACCESS		read-write
320		STATUS			current
321		DESCRIPTION		"The physical input on which this transport stream appears"
322		::=  {  mgFilterEntry  1  }
323
324  oldPID	OBJECT-TYPE
325		SYNTAX			DisplayString  ( SIZE ( 0 .. 1024  ) )
326		MAX-ACCESS		read-write
327		STATUS			current
328		DESCRIPTION		"The old PID will be filtered output"
329		::=  {  mgFilterEntry  2  }
330
331  newPID	OBJECT-TYPE
332		SYNTAX			DisplayString  ( SIZE ( 0 .. 1024  ) )
333		MAX-ACCESS		read-write
334		STATUS			current
335		DESCRIPTION		"The new PID is bulit according to old PID"
336		::=  {  mgFilterEntry  3  }
337
338  oldProgramNumber	OBJECT-TYPE
339		SYNTAX			DisplayString  ( SIZE ( 0 .. 1024  ) )
340		MAX-ACCESS		read-write
341		STATUS			current
342		DESCRIPTION		"The old program number,they come from PAT and will be filtered output"
343		::=  {  mgFilterEntry  4  }
344
345  newProgramNumber	OBJECT-TYPE
346		SYNTAX			DisplayString  ( SIZE ( 0 .. 1024  ) )
347		MAX-ACCESS		read-write
348		STATUS			current
349		DESCRIPTION		"The new program number, they are bulit and will be made a new PAT"
350		::=  {  mgFilterEntry  5  }
351
352	mgCATEntry	OBJECT-TYPE
353		SYNTAX		MgCATEntry
354		MAX-ACCESS	not-accessible
355		STATUS		current
356		DESCRIPTION	"Row Description"
357		INDEX		{  channelInputCAT  }
358		::=  { mgCATTable 1 }
359
360	MgCATEntry  ::=  SEQUENCE {
361		channelInputCAT  INTEGER,
362    catSection       DisplayString
363	}
364
365	channelInputCAT	OBJECT-TYPE
366		SYNTAX			INTEGER  ( -2147483648 .. 2147483647  )
367		MAX-ACCESS		read-write
368		STATUS			current
369		DESCRIPTION		"The physical input on which this transport stream appears"
370		::=  {  mgCATEntry  1  }
371
372  catSection	OBJECT-TYPE
373		SYNTAX			DisplayString  ( SIZE ( 0 .. 1024  ) )
374		MAX-ACCESS		read-write
375		STATUS			current
376		DESCRIPTION		"The transport stream Relating to the CAT seciton, reference ISO/IEC 13818-1 "
377		::=  {  mgCATEntry  2  }
378
379	channelInput 	OBJECT-TYPE
380		SYNTAX			INTEGER
381		MAX-ACCESS		read-write
382		STATUS			current
383		DESCRIPTION		"channel number of input"
384		::=  {  tsInput  1  }
385
386	stateLock 	OBJECT-TYPE
387		SYNTAX			INTEGER
388		MAX-ACCESS		read-write
389		STATUS			current
390		DESCRIPTION		"0xFFFF is lock, other is unlock"
391		::=  {  tsInput  2  }
392
393	tsIdPreference 	OBJECT-TYPE
394		SYNTAX			INTEGER
395		MAX-ACCESS		read-write
396		STATUS			current
397		DESCRIPTION		"transport stream identifier"
398		::=  {  tsInput  3  }
399
400	mgBATEntry	OBJECT-TYPE
401		SYNTAX		MgBATEntry
402		MAX-ACCESS	not-accessible
403		STATUS		current
404		DESCRIPTION	"Row Description"
405		INDEX		{  channelBAT  }
406		::=  { mgBATTable 1 }
407
408	MgBATEntry  ::=  SEQUENCE {
409		channelBAT  		  INTEGER,
410   	batSection        DisplayString
411	}
412
413	channelBAT 	OBJECT-TYPE
414		SYNTAX			INTEGER
415		MAX-ACCESS		read-write
416		STATUS			current
417		DESCRIPTION		"specify channel of get BAT "
418		::=  {  mgBATEntry  1  }
419
420	batSection 	OBJECT-TYPE
421		SYNTAX			DisplayString ( SIZE ( 0 .. 1024  ) )
422		MAX-ACCESS		read-write
423		STATUS			current
424		DESCRIPTION		"The transport stream Relating to the BAT seciton, reference ISO/IEC 13818-1 "
425		::=  {  mgBATEntry  2  }
426
427END
428