Man page generated from reStructuredText.
.
SAQUERY 8 "" "" "Open IB Diagnostics"
NAME
SAQUERY - . .nr rst2man-indent-level 0 . \\$1 \\n[an-margin] level \\n[rst2man-indent-level] level margin: \\n[rst2man-indent\\n[rst2man-indent-level]] - \\n[rst2man-indent0] \\n[rst2man-indent1] \\n[rst2man-indent2] .. .rstReportMargin pre:
. RS \\$1 . nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin] . nr rst2man-indent-level +1 .rstReportMargin post:
.. . RE indent \\n[an-margin]
old: \\n[rst2man-indent\\n[rst2man-indent-level]]
.nr rst2man-indent-level -1 new: \\n[rst2man-indent\\n[rst2man-indent-level]]
..
QUERY INFINIBAND SUBNET ADMINISTRATION ATTRIBUTES
SYNOPSIS
saquery [options] [<name> | <lid> | <guid>]
DESCRIPTION
saquery issues the selected SA query. Node records are queried by default.
OPTIONS
NDENT 0.0

-p get PathRecord info

-N get NodeRecord info

-D, --list get NodeDescriptions of CAs only

-S get ServiceRecord info

-I get InformInfoRecord (subscription) info

-L return the Lids of the name specified

-l return the unique Lid of the name specified

-G return the Guids of the name specified

-O return the name for the Lid specified

-U return the name for the Guid specified

-c get the SA\(aqs class port info

-s return the PortInfoRecords with isSM or isSMdisabled capability mask bit on

-g get multicast group info

-m get multicast member info. If a group is specified, limit the output to the group specified and print one line containing only the GUID and node description for each entry. Example: saquery -m 0xc000

-x get LinkRecord info

--src-to-dst <src:dst> get a PathRecord for <src:dst> where src and dst are either node names or LIDs

--sgid-to-dgid <sgid:dgid> get a PathRecord for sgid to dgid where both GIDs are in an IPv6 format acceptable to inet_pton (3)

--smkey <val> use SM_Key value for the query. Will be used only with "trusted" queries. If non-numeric value (like \(aqx\(aq) is specified then saquery will prompt for a value. Default (when not specified here or in /etc/infiniband-diags/ibdiag.conf) is to use SM_Key == 0 (or "untrusted")

--sa-dgid <gid> Set the destination GID (in IPv6 format) of the SA in the GRH of the request. Either the actual SM GID or the SA well known GID (0::2) can be used to include in the GRH of the SA queries. NINDENT Define the common option -K
. NDENT 0.0

-K, --show_keys show security keys (mkey, smkey, etc.) associated with the request. NINDENT --slid <lid> Source LID (PathRecord) --dlid <lid> Destination LID (PathRecord) --mlid <lid> Multicast LID (MCMemberRecord) --sgid <gid> Source GID (IPv6 format) (PathRecord) --dgid <gid> Destination GID (IPv6 format) (PathRecord) --gid <gid> Port GID (MCMemberRecord) --mgid <gid> Multicast GID (MCMemberRecord) --reversible Reversible path (PathRecord) --numb_path Number of paths (PathRecord) NDENT 0.0

--pkey P_Key (PathRecord, MCMemberRecord). If non-numeric value (like \(aqx\(aq) is specified then saquery will prompt for a value NINDENT --qos_class QoS Class (PathRecord) --sl Service level (PathRecord, MCMemberRecord) --mtu MTU and selector (PathRecord, MCMemberRecord) --rate Rate and selector (PathRecord, MCMemberRecord) --pkt_lifetime Packet lifetime and selector (PathRecord, MCMemberRecord) NDENT 0.0

--qkey Q_Key (MCMemberRecord). If non-numeric value (like \(aqx\(aq) is specified then saquery will prompt for a value NINDENT --tclass Traffic Class (PathRecord, MCMemberRecord) --flow_label Flow Label (PathRecord, MCMemberRecord) --hop_limit Hop limit (PathRecord, MCMemberRecord) --scope Scope (MCMemberRecord) --join_state Join state (MCMemberRecord) --proxy_join Proxy join (MCMemberRecord) --service_id ServiceID (PathRecord) Supported query names (and aliases): NDENT 0.0 NDENT 3.5

ClassPortInfo (CPI)
NodeRecord (NR) [lid]
PortInfoRecord (PIR) [[lid]/[port]/[options]]
SL2VLTableRecord (SL2VL) [[lid]/[in_port]/[out_port]]
PKeyTableRecord (PKTR) [[lid]/[port]/[block]]
VLArbitrationTableRecord (VLAR) [[lid]/[port]/[block]]
InformInfoRecord (IIR)
LinkRecord (LR) [[from_lid]/[from_port]] [[to_lid]/[to_port]]
ServiceRecord (SR)
PathRecord (PR)
MCMemberRecord (MCMR)
LFTRecord (LFTR) [[lid]/[block]]
MFTRecord (MFTR) [[mlid]/[position]/[block]]
GUIDInfoRecord (GIR) [[lid]/[block]]
SwitchInfoRecord (SWIR) [lid]
SMInfoRecord (SMIR) [lid]
NINDENT NINDENT
Port Selection flags
Define the common option -C
. -C, --Ca <ca_name> use the specified ca_name. Define the common option -P
. -P, --Port <ca_port> use the specified ca_port. Explanation of local port selection
.
Local port Selection
Multiple port/Multiple CA support: when no IB device or port is specified (see the "local umad parameters" below), the libibumad library selects the port to use by the following criteria: NDENT 0.0 NDENT 3.5 NDENT 0.0
1. 3
the first port that is ACTIVE.
2. 3
if not found, the first port that is UP (physical link up). NINDENT If a port and/or CA name is specified, the libibumad library attempts to fulfill the user request, and will fail if it is not possible. For example: NDENT 0.0 NDENT 3.5
ibaddr # use the first port (criteria #1 above)
ibaddr -C mthca1 # pick the best port from "mthca1" only.
ibaddr -P 2 # use the second (active/up) port from the first available IB device.
ibaddr -C mthca0 -P 2 # use the specified port only.
NINDENT NINDENT NINDENT NINDENT
Debugging flags
Define the common option -d
. NDENT 0.0

-d raise the IB debugging level. May be used several times (-ddd or -d -d -d). NINDENT Define the common option -e
. NDENT 0.0

-e show send and receive errors (timeouts and others) NINDENT Define the common option -h
. -h, --help show the usage message Define the common option -v
. NDENT 0.0

-v, --verbose increase the application verbosity level. May be used several times (-vv or -v -v -v) NINDENT Define the common option -V
. -V, --version show the version info.

Configuration flags
Define the common option -t
. -t, --timeout <timeout_ms> override the default timeout for the solicited mads. Define the common option -z
. NDENT 0.0

--outstanding_smps, -o <val> Specify the number of outstanding SMP\(aqs which should be issued during the scan Default: 2 NINDENT Define the common option --node-name-map
. --node-name-map <node-name-map> Specify a node name map. NDENT 0.0 NDENT 3.5 This file maps GUIDs to more user friendly names. See FILES section. NINDENT NINDENT Define the common option -z
. --config, -z <config_file> Specify alternate config file. NDENT 0.0 NDENT 3.5 Default: /etc/infiniband-diags/ibdiag.conf NINDENT NINDENT

COMMON FILES
Common text for the config file
.
CONFIG FILE
/etc/infiniband-diags/ibdiag.conf A global config file is provided to set some of the common options for all tools. See supplied config file for details. Common text to describe the node name map file.
.
NODE NAME MAP FILE FORMAT
The node name map is used to specify user friendly names for nodes in the output. GUIDs are used to perform the lookup. This functionality is provided by the opensm-libs package. See opensm(8) for the file location for your installation. Generically: NDENT 0.0 NDENT 3.5
# comment
<guid> "<name>"
NINDENT NINDENT Example: NDENT 0.0 NDENT 3.5
# IB1
# Line cards
0x0008f104003f125c "IB1 (Rack 11 slot 1 ) ISR9288/ISR9096 Voltaire sLB-24D"
0x0008f104003f125d "IB1 (Rack 11 slot 1 ) ISR9288/ISR9096 Voltaire sLB-24D"
0x0008f104003f10d2 "IB1 (Rack 11 slot 2 ) ISR9288/ISR9096 Voltaire sLB-24D"
0x0008f104003f10d3 "IB1 (Rack 11 slot 2 ) ISR9288/ISR9096 Voltaire sLB-24D"
0x0008f104003f10bf "IB1 (Rack 11 slot 12 ) ISR9288/ISR9096 Voltaire sLB-24D"

# Spines
0x0008f10400400e2d "IB1 (Rack 11 spine 1 ) ISR9288 Voltaire sFB-12D"
0x0008f10400400e2e "IB1 (Rack 11 spine 1 ) ISR9288 Voltaire sFB-12D"
0x0008f10400400e2f "IB1 (Rack 11 spine 1 ) ISR9288 Voltaire sFB-12D"
0x0008f10400400e31 "IB1 (Rack 11 spine 2 ) ISR9288 Voltaire sFB-12D"
0x0008f10400400e32 "IB1 (Rack 11 spine 2 ) ISR9288 Voltaire sFB-12D"

# GUID Node Name
0x0008f10400411a08 "SW1 (Rack 3) ISR9024 Voltaire 9024D"
0x0008f10400411a28 "SW2 (Rack 3) ISR9024 Voltaire 9024D"
0x0008f10400411a34 "SW3 (Rack 3) ISR9024 Voltaire 9024D"
0x0008f104004119d0 "SW4 (Rack 3) ISR9024 Voltaire 9024D"
NINDENT NINDENT
DEPENDENCIES
OpenSM (or other running SM/SA), libosmcomp, libibumad, libibmad
AUTHORS
NDENT 0.0

Ira Weiny < \%ira.weiny@intel.com >

Hal Rosenstock < \%halr@mellanox.com > NINDENT Generated by docutils manpage writer.
.