xref: /freebsd/usr.sbin/pciconf/pciconf.8 (revision 190cef3d)
1.\" Copyright (c) 1997
2.\"	Stefan Esser <se@FreeBSD.org>. All rights reserved.
3.\"
4.\" Redistribution and use in source and binary forms, with or without
5.\" modification, are permitted provided that the following conditions
6.\" are met:
7.\" 1. Redistributions of source code must retain the above copyright
8.\"    notice, this list of conditions and the following disclaimer.
9.\"
10.\" 2. Redistributions in binary form must reproduce the above copyright
11.\"    notice, this list of conditions and the following disclaimer in the
12.\"    documentation and/or other materials provided with the distribution.
13.\"
14.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
15.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
16.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
17.\" ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
18.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
19.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
20.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
21.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
22.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
23.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
24.\" SUCH DAMAGE.
25.\"
26.\" $FreeBSD$
27.\"
28.Dd June 14, 2018
29.Dt PCICONF 8
30.Os
31.Sh NAME
32.Nm pciconf
33.Nd diagnostic utility for the PCI bus
34.Sh SYNOPSIS
35.Nm
36.Fl l Oo Fl BbceVv Oc Op Ar device
37.Nm
38.Fl a Ar device
39.Nm
40.Fl r Oo Fl b | h Oc Ar device addr Ns Op : Ns Ar addr2
41.Nm
42.Fl w Oo Fl b | h Oc Ar device addr value
43.Nm
44.Fl D Oo Fl b | h | x Oc Ar device addr Op start Ns Op : Ns Ar count
45.Sh DESCRIPTION
46The
47.Nm
48utility provides a command line interface to functionality provided by the
49.Xr pci 4
50.Xr ioctl 2
51interface.
52As such, some of the functions are only available to users with write
53access to
54.Pa /dev/pci ,
55normally only the super-user.
56.Pp
57With the
58.Fl l
59option,
60.Nm
61lists PCI devices in the following format:
62.Bd -literal
63foo0@pci0:0:4:0: class=0x010000 card=0x00000000 chip=0x000f1000 rev=0x01 \
64hdr=0x00
65bar0@pci0:0:5:0: class=0x000100 card=0x00000000 chip=0x88c15333 rev=0x00 \
66hdr=0x00
67none0@pci0:0:6:0: class=0x020000 card=0x00000000 chip=0x802910ec rev=0x00 \
68hdr=0x00
69.Ed
70.Pp
71The first column gives the
72driver name, unit number, and selector .
73If there is no driver attached to the
74.Tn PCI
75device in question, the driver name will be
76.Dq none .
77Unit numbers for detached devices start at zero and are incremented for
78each detached device that is encountered.
79The selector
80is in a form which may directly be used for the other forms of the command.
81The second column is the class code, with the class byte printed as two
82hex digits, followed by the sub-class and the interface bytes.
83The third column gives the contents of the subvendorid register, introduced
84in revision 2.1 of the
85.Tn PCI
86standard.
87Note that it will be 0 for older cards.
88The field consists of the card ID in the upper
89half and the card vendor ID in the lower half of the value.
90.Pp
91The fourth column contains the chip device ID, which identifies the chip
92this card is based on.
93It consists of two fields, identifying the chip and
94its vendor, as above.
95The fifth column prints the chip's revision.
96The sixth column describes the header type.
97Currently assigned header types include 0 for most devices,
981 for
99.Tn PCI
100to
101.Tn PCI
102bridges, and 2 for
103.Tn PCI
104to
105.Tn CardBus
106bridges.
107If the most significant bit
108of the header type register is set for
109function 0 of a
110.Tn PCI
111device, it is a
112.Em multi-function
113device, which contains several (similar or independent) functions on
114one chip.
115.Pp
116If the
117.Fl B
118option is supplied,
119.Nm
120will list additional information for
121.Tn PCI
122to
123.Tn PCI
124and
125.Tn PCI
126to
127.Tn CardBus
128bridges,
129specifically the resource ranges decoded by the bridge for use by devices
130behind the bridge.
131Each bridge lists a range of bus numbers handled by the bridge and its
132downstream devices.
133Memory and I/O port decoding windows are enumerated via a line in the
134following format:
135.Bd -literal
136    window[1c] = type I/O Port, range 16, addr 0x5000-0x8fff, enabled
137.Ed
138.Pp
139The first value after the
140.Dq Li window
141prefix in the square brackets is the offset of the decoding window in
142config space in hexadecimal.
143The type of a window is one of
144.Dq Memory ,
145.Dq Prefetchable Memory ,
146or
147.Dq I/O Port .
148The range indicates the binary log of the maximum address the window decodes.
149The address field indicates the start and end addresses of the decoded range.
150Finally, the last flag indicates if the window is enabled or disabled.
151.Pp
152If the
153.Fl b
154option is supplied,
155.Nm
156will list any base address registers
157.Pq BARs
158that are assigned resources for each device.
159Each BAR will be enumerated via a line in the following format:
160.Bd -literal
161    bar   [10] = type Memory, range 32, base 0xda060000, size 131072, enabled
162.Ed
163.Pp
164The first value after the
165.Dq Li bar
166prefix in the square brackets is the offset of the BAR in config space in
167hexadecimal.
168The type of a BAR is one of
169.Dq Memory ,
170.Dq Prefetchable Memory ,
171or
172.Dq I/O Port .
173The range indicates the binary log of the maximum address the BAR decodes.
174The base and size indicate the start and length of the BAR's address window,
175respectively.
176Finally, the last flag indicates if the BAR is enabled or disabled.
177.Pp
178If the
179.Fl c
180option is supplied,
181.Nm
182will list any capabilities supported by each device.
183Each capability is enumerated via a line in the following format:
184.Bd -literal
185    cap 10[40] = PCI-Express 1 root port
186.Ed
187.Pp
188The first value after the
189.Dq Li cap
190prefix is the capability ID in hexadecimal.
191The second value in the square brackets is the offset of the capability
192in config space in hexadecimal.
193The format of the text after the equals sign is capability-specific.
194.Pp
195Each extended capability is enumerated via a line in a similar format:
196.Bd -literal
197ecap 0002[100] = VC 1 max VC0
198.Ed
199.Pp
200The first value after the
201.Dq Li ecap
202prefix is the extended capability ID in hexadecimal.
203The second value in the square brackets is the offset of the extended
204capability in config space in hexadecimal.
205The format of the text after the equals sign is capability-specific.
206.Pp
207If the
208.Fl e
209option is supplied,
210.Nm
211will list any errors reported for this device in standard PCI error registers.
212Errors are checked for in the PCI status register,
213the PCI-express device status register,
214and the Advanced Error Reporting status registers.
215.Pp
216If the
217.Fl v
218option is supplied,
219.Nm
220will attempt to load the vendor/device information database, and print
221vendor, device, class and subclass identification strings for each device.
222.Pp
223If the
224.Fl V
225option is supplied,
226.Nm
227will list any vital product data
228.Pq VPD
229provided by each device.
230Each VPD keyword is enumerated via a line in the following format:
231.Bd -literal
232    VPD ro PN  = '110114640C0     '
233.Ed
234.Pp
235The first string after the
236.Dq Li VPD
237prefix indicates if the keyword is read-only
238.Dq ro
239or read-write
240.Dq rw .
241The second string provides the keyword name.
242The text after the equals sign lists the value of the keyword which is
243usually an ASCII string.
244.Pp
245If the optional
246.Ar device
247argument is given with the
248.Fl l
249flag,
250.Nm
251will only list details about a single device instead of all devices.
252.Pp
253All invocations of
254.Nm
255except for
256.Fl l
257require a
258.Ar device .
259The device can be identified either by a device name if the device is
260attached to a driver or by a selector.
261Selectors identify a PCI device by its address in PCI config space and
262can take one of the following forms:
263.Pp
264.Bl -bullet -offset indent -compact
265.It
266.Li pci Ns Va domain Ns \&: Ns Va bus Ns \&: Ns Va device Ns \&: \
267Ns Va function Ns
268.It
269.Li pci Ns Va bus Ns \&: Ns Va device Ns \&: Ns Va function Ns
270.It
271.Li pci Ns Va bus Ns \&: Ns Va device Ns
272.El
273.Pp
274In the case of an abridged form, omitted selector components are assumed to be 0.
275An optional leading device name followed by @ and an optional final colon
276will be ignored; this is so that the first column in the output of
277.Nm
278.Fl l
279can be used without modification.
280All numbers are base 10.
281.Pp
282With the
283.Fl a
284flag,
285.Nm
286determines whether any driver has been assigned to the device
287identified by
288.Ar selector .
289An exit status of zero indicates that the device has a driver;
290non-zero indicates that it does not.
291.Pp
292The
293.Fl r
294option reads a configuration space register at byte offset
295.Ar addr
296of device
297.Ar selector
298and prints out its value in hexadecimal.
299The optional second address
300.Ar addr2
301specifies a range to read.
302The
303.Fl w
304option writes the
305.Ar value
306into a configuration space register at byte offset
307.Ar addr
308of device
309.Ar selector .
310.Pp
311The
312.Fl D
313option request a dump of the specified BAR.
314Dump is performed to the standard output, raw register values
315are written.
316Use
317.Xr hexdump 1
318to convert them to human-readable dump,
319or redirect into a file to save the snapshot of the device state.
320Optionally, the
321.Ar start
322and
323.Ar count
324of the registers dumped can be specified, in multiple of the operation width,
325see next paragraph.
326.Pp
327For read, write, and dump operations, the flags
328.Fl b ,
329.Fl h ,
330and
331.Fl x
332select the width of the operation;
333.Fl b
334indicates a byte operation, and
335.Fl h
336indicates a halfword (two-byte) operation.
337.Fl x
338indicates a quadword (four-byte) operation.
339The default is to read or
340write a longword (four bytes).
341The quadword mode is only valid for BAR dump.
342.Sh ENVIRONMENT
343PCI vendor and device information is read from
344.Pa /usr/local/share/pciids/pci.ids .
345If that file is not present, it is read from
346.Pa /usr/share/misc/pci_vendors .
347This path can be overridden by setting the environment variable
348.Ev PCICONF_VENDOR_DATABASE .
349.Sh SEE ALSO
350.Xr ioctl 2 ,
351.\" .Xr pci 4 ,
352.Xr devinfo 8 ,
353.Xr kldload 8
354.Sh HISTORY
355The
356.Nm
357utility appeared first in
358.Fx 2.2 .
359The
360.Fl a
361option was added for
362.Tn PCI
363KLD support in
364.Fx 3.0 .
365.Sh AUTHORS
366.An -nosplit
367The
368.Nm
369utility was written by
370.An Stefan Esser
371and
372.An Garrett Wollman .
373.Sh BUGS
374The
375.Fl b
376and
377.Fl h
378options are implemented in
379.Nm ,
380but not in the underlying
381.Xr ioctl 2 .
382.Pp
383It might be useful to give non-root users access to the
384.Fl a
385and
386.Fl r
387options.
388But only root will be able to execute a
389.Nm kldload
390to provide the device with a driver KLD, and reading of configuration space
391registers may cause a failure in badly designed
392.Tn PCI
393chips.
394.Pp
395There is currently no way to specify the caching mode for the mapping
396established by the
397.Fl D
398option,
399.Nm
400always uses uncached access.
401This is fine for control register BARs.