Copyright (c) 1987 The Regents of the University of California. All rights reserved. This code is derived from software contributed to Berkeley by Computer Consoles Inc. Redistribution and use in source and binary forms are permitted provided that the above copyright notice and this paragraph are duplicated in all such forms and that any documentation, advertising materials, and other materials related to such distribution and use acknowledge that the software was developed by the University of California, Berkeley. The name of the University may not be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED ``AS IS'' AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTIBILITY AND FITNESS FOR A PARTICULAR PURPOSE. @(#)mpcctab.4 6.3 (Berkeley) 10/19/88 MPCCTAB 4 ""
C 7 NAME
mpcctab - MPCC configuration file
DESCRIPTION
The file
mpcctab is used to configure CCI's Multi-Protocol
Communication Controller (MPCC).
The controller provides high-speed
synchronous communications for the \s-1POWER 6\s+1 family
of computers.
This file determines the MPCC board
configurations. You can download either a synchronous , bisync or
an asynchronous protocol to an MPCC board.
See
dlmpcc(8)
for details.
A mpcctab file is supplied
with each MPCC release; however,
you can modify this file or create your own file
by using one of the \s-1UNIX\s+1 text editors.
The contents of the file
consists of entries that describe supported communication
protocols and their unique attributes. The protocols supported are
X.25, SNA, ASYNC, and BISYNC.
For ASYNC two different entries are possible in the
procol field - if 16 port MPCC async is configured, then ASYNC is
entered; 32 port MPCC async is specified by entering 32PORT.
This file must reside in the directory
/etc/mpcc.
Entry Line Format
An entry line consists of an
item identifier followed by
variable width arguments separated by colons. There are three
item identifiers: MPCC, PROTOCOL, PORT. The MPCC line in this file
identifies the board number. The PROTOCOL line identifies
the specific communication protocol.
The PORT line describes
the port for the immediately preceding protocol. The number
of arguments for the PROTOCOL and PORT lines,
and the arguments themselves,
are protocol dependent. See the individual
argument descriptions for details.
Notes: Use upper case letters for clarity when specifying the item
identifier and the protocol name. Make sure that you enter
the argument values in the order specified below. Also, use comments
liberally, and indicate comment lines by placing a
pound sign (#) in column one.
The item identifiers and their corresponding line
formats, with valid argument values, follow:
MPCC Line
Format:
MPCC:bdno:[FCCS,portno,timer]:[SOC,portno]
Argument Explanations:
bdno 8
Specifies the board number.
FCCS 8
FCCS is a fault-tolerant support system that allows backup ports
to assume the functions of failed ports.
For example,
if port 0 fails for any reason,
another port may be configured to assume the duties of the failed port.
The keyword
FCCS identifies this feature and must be
followed by the list of fail-safe port numbers and a time increment,
described below.
This feature is optional.
SOC 8
An FCCS port can also be an SOC (Switch On Close) port,
meaning that the port will switch when it is closed.
And as with FCCS, the port will switch if it fails.
This feature is optional.
portno 8
Portno is a list of port numbers,
separated by commas,
specifying the primary ports you want protected by backup ports.
FCCS boards have either 4 primary and 4 backup ports,
or 8 primary and 8 backup ports.
The valid port numbers are
0 through
3 for the 4-port version,
and
0 through
7 for the 8-port version.
Each of the ports has a switched connector.
If the board fails for any reason,
the traffic on these ports is automatically routed
through the switched connector.
These connectors must be cabled to secondary ports on the other FCCS
connector panels.
The secondary ports are numbered 8 through 11 on the 4-port version and
8 through 15 on the 8-port version.
Only the primary ports need be designated in the FCCS configuration line,
however all ports must be identified as described in the PORT Line section
below.
time 8
Specifies the time period for the sentinel relay timer.
Each board resets its sentinel timer after the specified
time period. If the
board fails, and therefore can't set the timer, then control
is passed automatically to another board, which continues
the current processing. This feature ensures PerpetualProcessing
and is transparent to the user. The valid range of values
in milliseconds is from
50 to
5950 in
50 millisecond increments.
PROTOCOL Line
Format:
Argument Explanations:
procol 10
Specifies the protocol you want associated with the
board specified in the previous
MPCC line.
depargs 10
Specifies the protocol-dependent protocol attributes. X.25 and SNA have ten (10)
arguments,
ASYNC has just one (1) argument, and BISYNC has no arguments.
.cu
X.25 Dependent Attributes
Note: You must be familiar with the
X.25 CCITT Yellow Book (1980)
in order to understand the following values.
N1 8
Specifies the maximum frame size in bytes.
N2 8
Specifies the retry count.
T1 8
Specifies the retry timer in milliseconds.
T2 8
Specifies the response delay timer in milliseconds.
T3 8
Specifies the inactive link timer in milliseconds.
T4 8
Specifies the idle channel timer in milliseconds.
K 8
Specifies the Level 2 window size.
xid1 8
Specifies the destination type in the XID command. It must be a number
from 1-5:
1 = AXE
2 = CTSS
3 = DEX
4 = DMS
5 = WESCOM
xid2 8
Specifies the destination identity in the XID command. It can be three to
nine ASCII characters.
xid3 8
Specifies the additional information in the XID command. It can be any
ASCII string up to 20 characters long.
.cu
ASYNC and 32PORT Dependent Attribute
bufsize 10
Specifies the size of the
transmit/
receive buffers in bytes.
PORT Line
Format:
PORT:portno:procol:depargs
Argument Explanations:
portno 10
Specifies the port number of the previously specified board.
procol 10
Specifies the protocol. You must state the same protocol
as you stated in the preceding PROTOCOL line.
depargs 10
Specifies the protocol-dependent port attributes. X.25 has
fourteen (14) arguments. ASYNC, 32PORT and BISYNC have none. SNA has 14
fixed arguments.
.cu
X.25 Dependent Arguments
Note: You must be familiar with the X.25 CCITT Yellow
Book (1980) in order to understand the following values.
ixmitbuf 12
Specifies the number of transmit buffers allocated
for I frames.
suxmitbuf 12
Specifies the number of transmit buffers allocated for
S/U frames.
irecvbuf 12
Specifies the number of receive buffers allocated for
I frames.
surecvbuf 12
Specifies the number of receive buffers allocated for
S/U frames.
xmito 12
Specifies the Level 1 transmit timeout.
This argument should be
0 so that Level 1 calculates timeout from
the baud rate.
rts 12
Specifies the modem control value
for rts. Valid values are
1 which equals
assert,
2 which equals
drop, and
3
which equals
auto.
dtr 12
Specifies the modem control value for dtr.
Valid values are
1 which equals
assert, and
2 which equals
drop.
lineidle 12
Specifies the line state between transmissions.
Valid values are
0 which specifies a flag
fill, and
1 which specifies a mark fill.
rcvadr 12
Specifies the port configuration. A
1 makes the port
a DCE, while a
3 makes the port a DTE.
mask 12
Specifies the data link receive mask. This argument must be
3.
xmtrty 12
Specifies the number of data link retries after a transmit
timeout. This argument should be zero since upper levels of X25 do retries.
baud 12
Specifies the baud rate of a transmission. All standard rates
are supported. Some common rate values are
0 equals a modem,
13 equals 9600, and
26 equals 56KB. See the header file
mp_port.h for other values.
encode 12
Specifies the physical data encoding. A
0 indicates NRZ, and a
1
indicates NRZI.
trace 12
Specifies the data link receive trace mode. This argument must be
0.
EXAMPLE
The following entry configures five MPCC boards: one for X.25,
ASYNC, 32PORT, BISYNC and SNA. Each has two ports.
MPCC:0
PROTOCOL:X25:272:2:6000:1000:30000:20000:8:2:ccice1:remote
PORT:0:X25:8:16:8:16:0:1:1:0:1:3:0:0:0:0
PORT:1:X25:8:16:8:16:0:1:1:0:3:3:0:0:0:0
MPCC:1
PROTOCOL:ASYNC:128
PORT:0:ASYNC
PORT:1:ASYNC
MPCC:2
PROTOCOL:32PORT:128
PORT:0:32PORT
PORT:1:32PORT
MPCC:3
PROTOCOL:BISYNC
PORT:0:BISYNC
PORT:1:BISYNC
MPCC:4
PROTOCOL:SNA:272:4:800:200:20000:20000:8:2:acey:deucy
PORT:0:SNA:8:10:10:24:5:3:1:0:193:193:1:0:0:0
PORT:1:SNA:8:10:10:24:5:3:1:0:193:193:1:0:0:0
FILES
/
etc/
mpcctab
/
etc/
mpcca
/
etc/
mpccb
/
etc/
mpcc32
/
etc/
mpccx
SEE ALSO