1# SPDX-License-Identifier: GPL-2.0-only
2#
3# Network device configuration
4#
5
6menuconfig NETDEVICES
7	default y if UML
8	depends on NET
9	bool "Network device support"
10	help
11	  You can say N here if you don't intend to connect your Linux box to
12	  any other computer at all.
13
14	  You'll have to say Y if your computer contains a network card that
15	  you want to use under Linux. If you are going to run SLIP or PPP over
16	  telephone line or null modem cable you need say Y here. Connecting
17	  two machines with parallel ports using PLIP needs this, as well as
18	  AX.25/KISS for sending Internet traffic over amateur radio links.
19
20	  See also "The Linux Network Administrator's Guide" by Olaf Kirch and
21	  Terry Dawson. Available at <http://www.tldp.org/guides.html>.
22
23	  If unsure, say Y.
24
25# All the following symbols are dependent on NETDEVICES - do not repeat
26# that for each of the symbols.
27if NETDEVICES
28
29config MII
30	tristate
31
32config NET_CORE
33	default y
34	bool "Network core driver support"
35	help
36	  You can say N here if you do not intend to use any of the
37	  networking core drivers (i.e. VLAN, bridging, bonding, etc.)
38
39if NET_CORE
40
41config BONDING
42	tristate "Bonding driver support"
43	depends on INET
44	depends on IPV6 || IPV6=n
45	depends on TLS || TLS_DEVICE=n
46	help
47	  Say 'Y' or 'M' if you wish to be able to 'bond' multiple Ethernet
48	  Channels together. This is called 'Etherchannel' by Cisco,
49	  'Trunking' by Sun, 802.3ad by the IEEE, and 'Bonding' in Linux.
50
51	  The driver supports multiple bonding modes to allow for both high
52	  performance and high availability operation.
53
54	  Refer to <file:Documentation/networking/bonding.rst> for more
55	  information.
56
57	  To compile this driver as a module, choose M here: the module
58	  will be called bonding.
59
60config DUMMY
61	tristate "Dummy net driver support"
62	help
63	  This is essentially a bit-bucket device (i.e. traffic you send to
64	  this device is consigned into oblivion) with a configurable IP
65	  address. It is most commonly used in order to make your currently
66	  inactive SLIP address seem like a real address for local programs.
67	  If you use SLIP or PPP, you might want to say Y here. It won't
68	  enlarge your kernel. What a deal. Read about it in the Network
69	  Administrator's Guide, available from
70	  <http://www.tldp.org/docs.html#guide>.
71
72	  To compile this driver as a module, choose M here: the module
73	  will be called dummy.
74
75config WIREGUARD
76	tristate "WireGuard secure network tunnel"
77	depends on NET && INET
78	depends on IPV6 || !IPV6
79	select NET_UDP_TUNNEL
80	select DST_CACHE
81	select CRYPTO
82	select CRYPTO_LIB_CURVE25519
83	select CRYPTO_LIB_CHACHA20POLY1305
84	select CRYPTO_LIB_BLAKE2S
85	select CRYPTO_CHACHA20_X86_64 if X86 && 64BIT
86	select CRYPTO_POLY1305_X86_64 if X86 && 64BIT
87	select CRYPTO_BLAKE2S_X86 if X86 && 64BIT
88	select CRYPTO_CURVE25519_X86 if X86 && 64BIT
89	select ARM_CRYPTO if ARM
90	select ARM64_CRYPTO if ARM64
91	select CRYPTO_CHACHA20_NEON if ARM || (ARM64 && KERNEL_MODE_NEON)
92	select CRYPTO_POLY1305_NEON if ARM64 && KERNEL_MODE_NEON
93	select CRYPTO_POLY1305_ARM if ARM
94	select CRYPTO_BLAKE2S_ARM if ARM
95	select CRYPTO_CURVE25519_NEON if ARM && KERNEL_MODE_NEON
96	select CRYPTO_CHACHA_MIPS if CPU_MIPS32_R2
97	select CRYPTO_POLY1305_MIPS if MIPS
98	help
99	  WireGuard is a secure, fast, and easy to use replacement for IPSec
100	  that uses modern cryptography and clever networking tricks. It's
101	  designed to be fairly general purpose and abstract enough to fit most
102	  use cases, while at the same time remaining extremely simple to
103	  configure. See www.wireguard.com for more info.
104
105	  It's safe to say Y or M here, as the driver is very lightweight and
106	  is only in use when an administrator chooses to add an interface.
107
108config WIREGUARD_DEBUG
109	bool "Debugging checks and verbose messages"
110	depends on WIREGUARD
111	help
112	  This will write log messages for handshake and other events
113	  that occur for a WireGuard interface. It will also perform some
114	  extra validation checks and unit tests at various points. This is
115	  only useful for debugging.
116
117	  Say N here unless you know what you're doing.
118
119config EQUALIZER
120	tristate "EQL (serial line load balancing) support"
121	help
122	  If you have two serial connections to some other computer (this
123	  usually requires two modems and two telephone lines) and you use
124	  SLIP (the protocol for sending Internet traffic over telephone
125	  lines) or PPP (a better SLIP) on them, you can make them behave like
126	  one double speed connection using this driver.  Naturally, this has
127	  to be supported at the other end as well, either with a similar EQL
128	  Linux driver or with a Livingston Portmaster 2e.
129
130	  Say Y if you want this and read
131	  <file:Documentation/networking/eql.rst>.  You may also want to read
132	  section 6.2 of the NET-3-HOWTO, available from
133	  <http://www.tldp.org/docs.html#howto>.
134
135	  To compile this driver as a module, choose M here: the module
136	  will be called eql.  If unsure, say N.
137
138config NET_FC
139	bool "Fibre Channel driver support"
140	depends on SCSI && PCI
141	help
142	  Fibre Channel is a high speed serial protocol mainly used to connect
143	  large storage devices to the computer; it is compatible with and
144	  intended to replace SCSI.
145
146	  If you intend to use Fibre Channel, you need to have a Fibre channel
147	  adaptor card in your computer; say Y here and to the driver for your
148	  adaptor below. You also should have said Y to "SCSI support" and
149	  "SCSI generic support".
150
151config IFB
152	tristate "Intermediate Functional Block support"
153	depends on NET_CLS_ACT
154	select NET_REDIRECT
155	help
156	  This is an intermediate driver that allows sharing of
157	  resources.
158	  To compile this driver as a module, choose M here: the module
159	  will be called ifb.  If you want to use more than one ifb
160	  device at a time, you need to compile this driver as a module.
161	  Instead of 'ifb', the devices will then be called 'ifb0',
162	  'ifb1' etc.
163	  Look at the iproute2 documentation directory for usage etc
164
165source "drivers/net/team/Kconfig"
166
167config MACVLAN
168	tristate "MAC-VLAN support"
169	help
170	  This allows one to create virtual interfaces that map packets to
171	  or from specific MAC addresses to a particular interface.
172
173	  Macvlan devices can be added using the "ip" command from the
174	  iproute2 package starting with the iproute2-2.6.23 release:
175
176	  "ip link add link <real dev> [ address MAC ] [ NAME ] type macvlan"
177
178	  To compile this driver as a module, choose M here: the module
179	  will be called macvlan.
180
181config MACVTAP
182	tristate "MAC-VLAN based tap driver"
183	depends on MACVLAN
184	depends on INET
185	select TAP
186	help
187	  This adds a specialized tap character device driver that is based
188	  on the MAC-VLAN network interface, called macvtap. A macvtap device
189	  can be added in the same way as a macvlan device, using 'type
190	  macvtap', and then be accessed through the tap user space interface.
191
192	  To compile this driver as a module, choose M here: the module
193	  will be called macvtap.
194
195config IPVLAN_L3S
196	depends on NETFILTER
197	depends on IPVLAN
198	def_bool y
199	select NET_L3_MASTER_DEV
200
201config IPVLAN
202	tristate "IP-VLAN support"
203	depends on INET
204	depends on IPV6 || !IPV6
205	help
206	  This allows one to create virtual devices off of a main interface
207	  and packets will be delivered based on the dest L3 (IPv6/IPv4 addr)
208	  on packets. All interfaces (including the main interface) share L2
209	  making it transparent to the connected L2 switch.
210
211	  Ipvlan devices can be added using the "ip" command from the
212	  iproute2 package starting with the iproute2-3.19 release:
213
214	  "ip link add link <main-dev> [ NAME ] type ipvlan"
215
216	  To compile this driver as a module, choose M here: the module
217	  will be called ipvlan.
218
219config IPVTAP
220	tristate "IP-VLAN based tap driver"
221	depends on IPVLAN
222	depends on INET
223	select TAP
224	help
225	  This adds a specialized tap character device driver that is based
226	  on the IP-VLAN network interface, called ipvtap. An ipvtap device
227	  can be added in the same way as a ipvlan device, using 'type
228	  ipvtap', and then be accessed through the tap user space interface.
229
230	  To compile this driver as a module, choose M here: the module
231	  will be called ipvtap.
232
233config VXLAN
234	tristate "Virtual eXtensible Local Area Network (VXLAN)"
235	depends on INET
236	select NET_UDP_TUNNEL
237	select GRO_CELLS
238	help
239	  This allows one to create vxlan virtual interfaces that provide
240	  Layer 2 Networks over Layer 3 Networks. VXLAN is often used
241	  to tunnel virtual network infrastructure in virtualized environments.
242	  For more information see:
243	    http://tools.ietf.org/html/draft-mahalingam-dutt-dcops-vxlan-02
244
245	  To compile this driver as a module, choose M here: the module
246	  will be called vxlan.
247
248config GENEVE
249	tristate "Generic Network Virtualization Encapsulation"
250	depends on INET
251	depends on IPV6 || !IPV6
252	select NET_UDP_TUNNEL
253	select GRO_CELLS
254	help
255	  This allows one to create geneve virtual interfaces that provide
256	  Layer 2 Networks over Layer 3 Networks. GENEVE is often used
257	  to tunnel virtual network infrastructure in virtualized environments.
258	  For more information see:
259	    http://tools.ietf.org/html/draft-gross-geneve-02
260
261	  To compile this driver as a module, choose M here: the module
262	  will be called geneve.
263
264config BAREUDP
265       tristate "Bare UDP Encapsulation"
266       depends on INET
267       depends on IPV6 || !IPV6
268       select NET_UDP_TUNNEL
269       select GRO_CELLS
270       help
271          This adds a bare UDP tunnel module for tunnelling different
272          kinds of traffic like MPLS, IP, etc. inside a UDP tunnel.
273
274          To compile this driver as a module, choose M here: the module
275          will be called bareudp.
276
277config GTP
278	tristate "GPRS Tunneling Protocol datapath (GTP-U)"
279	depends on INET
280	select NET_UDP_TUNNEL
281	help
282	  This allows one to create gtp virtual interfaces that provide
283	  the GPRS Tunneling Protocol datapath (GTP-U). This tunneling protocol
284	  is used to prevent subscribers from accessing mobile carrier core
285	  network infrastructure. This driver requires a userspace software that
286	  implements the signaling protocol (GTP-C) to update its PDP context
287	  base, such as OpenGGSN <http://git.osmocom.org/openggsn/). This
288	  tunneling protocol is implemented according to the GSM TS 09.60 and
289	  3GPP TS 29.060 standards.
290
291	  To compile this drivers as a module, choose M here: the module
292	  will be called gtp.
293
294config MACSEC
295	tristate "IEEE 802.1AE MAC-level encryption (MACsec)"
296	select CRYPTO
297	select CRYPTO_AES
298	select CRYPTO_GCM
299	select GRO_CELLS
300	help
301	   MACsec is an encryption standard for Ethernet.
302
303config NETCONSOLE
304	tristate "Network console logging support"
305	help
306	  If you want to log kernel messages over the network, enable this.
307	  See <file:Documentation/networking/netconsole.rst> for details.
308
309config NETCONSOLE_DYNAMIC
310	bool "Dynamic reconfiguration of logging targets"
311	depends on NETCONSOLE && SYSFS && CONFIGFS_FS && \
312			!(NETCONSOLE=y && CONFIGFS_FS=m)
313	help
314	  This option enables the ability to dynamically reconfigure target
315	  parameters (interface, IP addresses, port numbers, MAC addresses)
316	  at runtime through a userspace interface exported using configfs.
317	  See <file:Documentation/networking/netconsole.rst> for details.
318
319config NETPOLL
320	def_bool NETCONSOLE
321	select SRCU
322
323config NET_POLL_CONTROLLER
324	def_bool NETPOLL
325
326config NTB_NETDEV
327	tristate "Virtual Ethernet over NTB Transport"
328	depends on NTB_TRANSPORT
329
330config RIONET
331	tristate "RapidIO Ethernet over messaging driver support"
332	depends on RAPIDIO
333
334config RIONET_TX_SIZE
335	int "Number of outbound queue entries"
336	depends on RIONET
337	default "128"
338
339config RIONET_RX_SIZE
340	int "Number of inbound queue entries"
341	depends on RIONET
342	default "128"
343
344config TUN
345	tristate "Universal TUN/TAP device driver support"
346	depends on INET
347	select CRC32
348	help
349	  TUN/TAP provides packet reception and transmission for user space
350	  programs.  It can be viewed as a simple Point-to-Point or Ethernet
351	  device, which instead of receiving packets from a physical media,
352	  receives them from user space program and instead of sending packets
353	  via physical media writes them to the user space program.
354
355	  When a program opens /dev/net/tun, driver creates and registers
356	  corresponding net device tunX or tapX.  After a program closed above
357	  devices, driver will automatically delete tunXX or tapXX device and
358	  all routes corresponding to it.
359
360	  Please read <file:Documentation/networking/tuntap.rst> for more
361	  information.
362
363	  To compile this driver as a module, choose M here: the module
364	  will be called tun.
365
366	  If you don't know what to use this for, you don't need it.
367
368config TAP
369	tristate
370	help
371	  This option is selected by any driver implementing tap user space
372	  interface for a virtual interface to re-use core tap functionality.
373
374config TUN_VNET_CROSS_LE
375	bool "Support for cross-endian vnet headers on little-endian kernels"
376	default n
377	help
378	  This option allows TUN/TAP and MACVTAP device drivers in a
379	  little-endian kernel to parse vnet headers that come from a
380	  big-endian legacy virtio device.
381
382	  Userspace programs can control the feature using the TUNSETVNETBE
383	  and TUNGETVNETBE ioctls.
384
385	  Unless you have a little-endian system hosting a big-endian virtual
386	  machine with a legacy virtio NIC, you should say N.
387
388config VETH
389	tristate "Virtual ethernet pair device"
390	help
391	  This device is a local ethernet tunnel. Devices are created in pairs.
392	  When one end receives the packet it appears on its pair and vice
393	  versa.
394
395config VIRTIO_NET
396	tristate "Virtio network driver"
397	depends on VIRTIO
398	select NET_FAILOVER
399	help
400	  This is the virtual network driver for virtio.  It can be used with
401	  QEMU based VMMs (like KVM or Xen).  Say Y or M.
402
403config NLMON
404	tristate "Virtual netlink monitoring device"
405	help
406	  This option enables a monitoring net device for netlink skbs. The
407	  purpose of this is to analyze netlink messages with packet sockets.
408	  Thus applications like tcpdump will be able to see local netlink
409	  messages if they tap into the netlink device, record pcaps for further
410	  diagnostics, etc. This is mostly intended for developers or support
411	  to debug netlink issues. If unsure, say N.
412
413config NET_VRF
414	tristate "Virtual Routing and Forwarding (Lite)"
415	depends on IP_MULTIPLE_TABLES
416	depends on NET_L3_MASTER_DEV
417	depends on IPV6 || IPV6=n
418	depends on IPV6_MULTIPLE_TABLES || IPV6=n
419	help
420	  This option enables the support for mapping interfaces into VRF's. The
421	  support enables VRF devices.
422
423config VSOCKMON
424	tristate "Virtual vsock monitoring device"
425	depends on VHOST_VSOCK
426	help
427	  This option enables a monitoring net device for vsock sockets. It is
428	  mostly intended for developers or support to debug vsock issues. If
429	  unsure, say N.
430
431config MHI_NET
432	tristate "MHI network driver"
433	depends on MHI_BUS
434	help
435	  This is the network driver for MHI bus.  It can be used with
436	  QCOM based WWAN modems (like SDX55).  Say Y or M.
437
438endif # NET_CORE
439
440config SUNGEM_PHY
441	tristate
442
443source "drivers/net/arcnet/Kconfig"
444
445source "drivers/atm/Kconfig"
446
447source "drivers/net/caif/Kconfig"
448
449source "drivers/net/dsa/Kconfig"
450
451source "drivers/net/ethernet/Kconfig"
452
453source "drivers/net/fddi/Kconfig"
454
455source "drivers/net/hippi/Kconfig"
456
457source "drivers/net/ipa/Kconfig"
458
459config NET_SB1000
460	tristate "General Instruments Surfboard 1000"
461	depends on PNP
462	help
463	  This is a driver for the General Instrument (also known as
464	  NextLevel) SURFboard 1000 internal
465	  cable modem. This is an ISA card which is used by a number of cable
466	  TV companies to provide cable modem access. It's a one-way
467	  downstream-only cable modem, meaning that your upstream net link is
468	  provided by your regular phone modem.
469
470	  At present this driver only compiles as a module, so say M here if
471	  you have this card. The module will be called sb1000. Then read
472	  <file:Documentation/networking/device_drivers/cable/sb1000.rst> for
473	  information on how to use this module, as it needs special ppp
474	  scripts for establishing a connection. Further documentation
475	  and the necessary scripts can be found at:
476
477	  <http://www.jacksonville.net/~fventuri/>
478	  <http://home.adelphia.net/~siglercm/sb1000.html>
479	  <http://linuxpower.cx/~cable/>
480
481	  If you don't have this card, of course say N.
482
483source "drivers/net/phy/Kconfig"
484
485source "drivers/net/mdio/Kconfig"
486
487source "drivers/net/pcs/Kconfig"
488
489source "drivers/net/plip/Kconfig"
490
491source "drivers/net/ppp/Kconfig"
492
493source "drivers/net/slip/Kconfig"
494
495source "drivers/s390/net/Kconfig"
496
497source "drivers/net/usb/Kconfig"
498
499source "drivers/net/wireless/Kconfig"
500
501source "drivers/net/wan/Kconfig"
502
503source "drivers/net/ieee802154/Kconfig"
504
505source "drivers/net/wwan/Kconfig"
506
507config XEN_NETDEV_FRONTEND
508	tristate "Xen network device frontend driver"
509	depends on XEN
510	select XEN_XENBUS_FRONTEND
511	select PAGE_POOL
512	default y
513	help
514	  This driver provides support for Xen paravirtual network
515	  devices exported by a Xen network driver domain (often
516	  domain 0).
517
518	  The corresponding Linux backend driver is enabled by the
519	  CONFIG_XEN_NETDEV_BACKEND option.
520
521	  If you are compiling a kernel for use as Xen guest, you
522	  should say Y here. To compile this driver as a module, chose
523	  M here: the module will be called xen-netfront.
524
525config XEN_NETDEV_BACKEND
526	tristate "Xen backend network device"
527	depends on XEN_BACKEND
528	help
529	  This driver allows the kernel to act as a Xen network driver
530	  domain which exports paravirtual network devices to other
531	  Xen domains. These devices can be accessed by any operating
532	  system that implements a compatible front end.
533
534	  The corresponding Linux frontend driver is enabled by the
535	  CONFIG_XEN_NETDEV_FRONTEND configuration option.
536
537	  The backend driver presents a standard network device
538	  endpoint for each paravirtual network device to the driver
539	  domain network stack. These can then be bridged or routed
540	  etc in order to provide full network connectivity.
541
542	  If you are compiling a kernel to run in a Xen network driver
543	  domain (often this is domain 0) you should say Y here. To
544	  compile this driver as a module, chose M here: the module
545	  will be called xen-netback.
546
547config VMXNET3
548	tristate "VMware VMXNET3 ethernet driver"
549	depends on PCI && INET
550	depends on !(PAGE_SIZE_64KB || ARM64_64K_PAGES || \
551		     IA64_PAGE_SIZE_64KB || MICROBLAZE_64K_PAGES || \
552		     PARISC_PAGE_SIZE_64KB || PPC_64K_PAGES)
553	help
554	  This driver supports VMware's vmxnet3 virtual ethernet NIC.
555	  To compile this driver as a module, choose M here: the
556	  module will be called vmxnet3.
557
558config FUJITSU_ES
559	tristate "FUJITSU Extended Socket Network Device driver"
560	depends on ACPI
561	help
562	  This driver provides support for Extended Socket network device
563	  on Extended Partitioning of FUJITSU PRIMEQUEST 2000 E2 series.
564
565config USB4_NET
566	tristate "Networking over USB4 and Thunderbolt cables"
567	depends on USB4 && INET
568	help
569	  Select this if you want to create network between two computers
570	  over a USB4 and Thunderbolt cables. The driver supports Apple
571	  ThunderboltIP protocol and allows communication with any host
572	  supporting the same protocol including Windows and macOS.
573
574	  To compile this driver a module, choose M here. The module will be
575	  called thunderbolt-net.
576
577source "drivers/net/hyperv/Kconfig"
578
579config NETDEVSIM
580	tristate "Simulated networking device"
581	depends on DEBUG_FS
582	depends on INET
583	depends on IPV6 || IPV6=n
584	depends on PSAMPLE || PSAMPLE=n
585	select NET_DEVLINK
586	help
587	  This driver is a developer testing tool and software model that can
588	  be used to test various control path networking APIs, especially
589	  HW-offload related.
590
591	  To compile this driver as a module, choose M here: the module
592	  will be called netdevsim.
593
594config NET_FAILOVER
595	tristate "Failover driver"
596	select FAILOVER
597	help
598	  This provides an automated failover mechanism via APIs to create
599	  and destroy a failover master netdev and manages a primary and
600	  standby slave netdevs that get registered via the generic failover
601	  infrastructure. This can be used by paravirtual drivers to enable
602	  an alternate low latency datapath. It also enables live migration of
603	  a VM with direct attached VF by failing over to the paravirtual
604	  datapath when the VF is unplugged.
605
606endif # NETDEVICES
607