1-- ***************************************************************** 2-- CISCO-CAT6K-CROSSBAR-MIB.my 3-- 4-- Mar 2001, Padma Pullela 5-- Nov. 2002, Padma Pullela/Lilian Jiang 6-- March 2003, Padma Pullela 7-- June 2004, Padma Pullela 8-- 9-- Copyright (c) 2001-2009, 2012-2013 by cisco Systems, Inc. 10-- All rights reserved. 11-- ***************************************************************** 12 13CISCO-CAT6K-CROSSBAR-MIB DEFINITIONS ::= BEGIN 14 15IMPORTS 16 MODULE-IDENTITY, 17 OBJECT-TYPE, 18 Counter32, 19 Unsigned32, 20 Gauge32, 21 NOTIFICATION-TYPE 22 FROM SNMPv2-SMI 23 MODULE-COMPLIANCE, 24 OBJECT-GROUP, 25 NOTIFICATION-GROUP 26 FROM SNMPv2-CONF 27 TEXTUAL-CONVENTION, 28 TruthValue, 29 DisplayString, 30 DateAndTime, 31 TimeStamp 32 FROM SNMPv2-TC 33 entPhysicalName, 34 entPhysicalVendorType, 35 entPhysicalIndex, 36 entPhysicalDescr 37 FROM ENTITY-MIB 38 Percent 39 FROM CISCO-QOS-PIB-MIB 40 ciscoMgmt 41 FROM CISCO-SMI; 42 43 44ciscoCat6kCrossbarMIB MODULE-IDENTITY 45 LAST-UPDATED "201309160000Z" 46 ORGANIZATION "Cisco Systems, Inc." 47 CONTACT-INFO 48 "Cisco Systems 49 Customer Service 50 Postal: 170 W Tasman Drive 51 San Jose, CA 95134 52 USA 53 Tel: +1 800 553-NETS 54 55 E-mail: cs-cat6000@cisco.com" 56 DESCRIPTION 57 "The Catalyst 6000 Crossbar MIB provides instrumentation for 58 configuration and operation of the crossbar switching fabric 59 module, and additional functionalities for switching bus 60 and internal bus, etc." 61 REVISION "201309160000Z" 62 DESCRIPTION 63 "Added two new enumerations 'pfc4xxl' and 'pfc4lite' 64 in cc6kxbarSysCapPfcOperMode." 65 REVISION "201205310000Z" 66 DESCRIPTION 67 "Added following OBJECT-GROUP 68 - cc6kxbarStatisticsLbusDropGroup 69 Added new compliance 70 - cc6kxbarMIBComplianceVer8. 71 Updated the description for 72 - cc6kxbarStatisticsPeakTmInUtil 73 - cc6kxbarStatisticsPeakTmOutUtil." 74 REVISION "200902150000Z" 75 DESCRIPTION 76 "Added cc6kxbarErrRcvryPersLinkResGroup and 77 cc6kxbarErrRcvryChResyncGroup, 78 cc6kxbarTMSwBusUtilGroup, 79 cc6kxbarTMSwBusUtilNotifControlGroup, 80 cc6kxbarTMSwBusUtilNotifObjectGroup, 81 cc6kxbarTMSwBusUtilNotifGroup, 82 cc6kxbarTMChUtilGroup, 83 cc6kxbarTMChUtilNotifControlGroup, 84 cc6kxbarTMChUtilNotifObjectGroup, 85 cc6kxbarTMChUtilNotifGroup. 86 87 Added two new enumerations 'pfc4' and 'pfc4xl' 88 in cc6kxbarSysCapPfcOperMode. 89 90 Added DISPLAY-HINT in TEXTUAL-CONVENTION 91 of ModuleSlotNumber and FabricChannelNumber." 92 REVISION "200712180000Z" 93 DESCRIPTION 94 "Added cc6kxbarSysCapPfcOperModeGroup, 95 cc6kxbarSysCapSwitchResGroup, cc6kxbarChannelUtilGroup1, 96 cc6kxbarSwBusGroup1, cc6kxbarErrorGroup, 97 cc6kxbarErrRcvryThresholdGroup and 98 cc6kxbarErrRcvrySwitchoverGroup." 99 REVISION "200612190000Z" 100 DESCRIPTION 101 "Added cc6kxbarDcefOnlyModeAllowedGroup, 102 cc6kxbarForceBusModeGroup, 103 cc6kxbarFlowCtrlNotifCtrlGroup, 104 cc6kxbarFlowCtrlBusThreshGroup, 105 cc6kxbarFlowCtrlBusThrNotifGroup 106 and cc6kxbarBusOnlyModeOperGroup." 107 REVISION "200411190000Z" 108 DESCRIPTION 109 "Added cc6kxbarIntBusCRCErrGroup." 110 REVISION "200408110000Z" 111 DESCRIPTION 112 "Added cc6kxbarIntBusNotifControlGroup and 113 cc6kxbarIntBusCRCErrNotifGroup." 114 REVISION "200406110000Z" 115 DESCRIPTION 116 "Added cc6kxbarTruncatedModeOper Object and changed the 117 description of cc6kxbarTruncatedModeAllowed and 118 cc6kxbarMinFabricPresent." 119 REVISION "200309290000Z" 120 DESCRIPTION 121 "Changed the description of cc6kxbarTruncatedModeAllowed and 122 cc6kxbarMinFabricPresent. Removed default value for 123 cc6kxbarTruncatedModeAllowed." 124 REVISION "200304020000Z" 125 DESCRIPTION 126 "Changed the SYNTAX and description of cc6kxbarMinFabricPresent 127 and description of cc6kxbarTruncatedModeAllowed." 128 REVISION "200212050000Z" 129 DESCRIPTION 130 "Added cc6kxbarModuleChannelSpeed, cc6kxbarSwBusSwitchingStatus, 131 cc6kxbarSwBusFailureDuration, cc6kxbarSwBusNotifEnable 132 objects and cc6kxbarSwBusStallNotif notification." 133 REVISION "200106250000Z" 134 DESCRIPTION 135 "Initial version of this MIB module." 136 ::= { ciscoMgmt 217 } 137 138 139ciscoCat6kXbarMIBObjects OBJECT IDENTIFIER 140 ::= { ciscoCat6kCrossbarMIB 1 } 141 142cc6kxbarConfiguration OBJECT IDENTIFIER 143 ::= { ciscoCat6kXbarMIBObjects 1 } 144 145cc6kxbarStatus OBJECT IDENTIFIER 146 ::= { ciscoCat6kXbarMIBObjects 2 } 147 148cc6kxbarStatistics OBJECT IDENTIFIER 149 ::= { ciscoCat6kXbarMIBObjects 3 } 150 151cc6kxbarSwBusObjects OBJECT IDENTIFIER 152 ::= { ciscoCat6kXbarMIBObjects 4 } 153 154cc6kxbarIntBusObjects OBJECT IDENTIFIER 155 ::= { ciscoCat6kXbarMIBObjects 5 } 156 157cc6kxbarFlowCtrlObjects OBJECT IDENTIFIER 158 ::= { ciscoCat6kXbarMIBObjects 6 } 159 160cc6kxbarSystemCapacityObjects OBJECT IDENTIFIER 161 ::= { ciscoCat6kXbarMIBObjects 7 } 162 163cc6kxbarErrorRecoveryObjects OBJECT IDENTIFIER 164 ::= { ciscoCat6kXbarMIBObjects 8 } 165 166cc6kxbarTrafficMonitorObjects OBJECT IDENTIFIER 167 ::= { ciscoCat6kXbarMIBObjects 9 } 168 169cc6kxbarTrafficMonitorSwBusObjects OBJECT IDENTIFIER 170 ::= { cc6kxbarTrafficMonitorObjects 1 } 171 172cc6kxbarTrafficMonitorChObjects OBJECT IDENTIFIER 173 ::= { cc6kxbarTrafficMonitorObjects 2 } 174 175 176-- Textual Conventions 177 178ModuleSlotNumber ::= TEXTUAL-CONVENTION 179 DISPLAY-HINT "d" 180 STATUS current 181 DESCRIPTION 182 "Slot number of the module." 183 SYNTAX Unsigned32 184 185FabricChannelNumber ::= TEXTUAL-CONVENTION 186 DISPLAY-HINT "d" 187 STATUS current 188 DESCRIPTION 189 "Fabric channel number." 190 SYNTAX Unsigned32 191 192ChannelStatus ::= TEXTUAL-CONVENTION 193 STATUS current 194 DESCRIPTION 195 "Status of the Channel." 196 SYNTAX INTEGER { 197 ok(1), 198 syncError(2), 199 heartbeatError(3), 200 crcError(4), 201 bufferError(5), 202 timeoutError(6), 203 unused(7) 204 } 205 206-- Configuration objects 207 208cc6kxbarFallbackMode OBJECT-TYPE 209 SYNTAX TruthValue 210 MAX-ACCESS read-write 211 STATUS current 212 DESCRIPTION 213 "cc6kxbarFallbackMode controls system fallback to bus-mode 214 after loss of switching fabric module. 215 'true' - When the last fabric card is removed 216 system will adjust the supervisor and 217 line cards switching mode automatically without 218 resetting the system. With this feature enabled, 219 the switch might lose traffic while it's 220 changing the switching mode. 221 'false' - All the ports in the system will be 222 disabled when the last fabric card is removed." 223 DEFVAL { true } 224 ::= { cc6kxbarConfiguration 1 } 225 226cc6kxbarBusOnlyModeAllowed OBJECT-TYPE 227 SYNTAX TruthValue 228 MAX-ACCESS read-write 229 STATUS current 230 DESCRIPTION 231 "Indicates whether bus mode is administratively enabled on 232 the device or not." 233 ::= { cc6kxbarConfiguration 2 } 234 235cc6kxbarTruncatedModeAllowed OBJECT-TYPE 236 SYNTAX TruthValue 237 MAX-ACCESS read-write 238 STATUS current 239 DESCRIPTION 240 "Indicates whether truncated mode is 241 administratively enabled on the device or not." 242 ::= { cc6kxbarConfiguration 3 } 243 244cc6kxbarMinFabricPresent OBJECT-TYPE 245 SYNTAX Unsigned32 246 MAX-ACCESS read-write 247 STATUS current 248 DESCRIPTION 249 "This object indicates the minimum number 250 of switching fabric capable modules to be present in the 251 system, for any switching fabric capable module to be in 252 'crossbarmode' indicated by cc6kxbarModuleModeSwitchingMode, 253 when cc6kxbarTruncatedModeOper is 'false'." 254 ::= { cc6kxbarConfiguration 4 } 255 256cc6kxbarLcdBannerTable OBJECT-TYPE 257 SYNTAX SEQUENCE OF Cc6kxbarLcdBannerEntry 258 MAX-ACCESS not-accessible 259 STATUS current 260 DESCRIPTION 261 "cc6kxbarLcdBannerTable configures the Lcd banner of the 262 fabric module." 263 ::= { cc6kxbarConfiguration 5 } 264 265cc6kxbarLcdBannerEntry OBJECT-TYPE 266 SYNTAX Cc6kxbarLcdBannerEntry 267 MAX-ACCESS not-accessible 268 STATUS current 269 DESCRIPTION 270 "An entry in cc6kxbarLcdBannerTable. 271 Entries are created by the agent based on the 272 size of the lcd banner." 273 INDEX { cc6kxbarLcdBannerIndex } 274 ::= { cc6kxbarLcdBannerTable 1 } 275 276Cc6kxbarLcdBannerEntry ::= SEQUENCE { 277 cc6kxbarLcdBannerIndex Unsigned32, 278 cc6kxbarLcdBannerBanner DisplayString, 279 cc6kxbarLcdBannerMaxSize Unsigned32 280} 281 282cc6kxbarLcdBannerIndex OBJECT-TYPE 283 SYNTAX Unsigned32 284 MAX-ACCESS not-accessible 285 STATUS current 286 DESCRIPTION 287 "Object which specifies a unique entry in the 288 table." 289 ::= { cc6kxbarLcdBannerEntry 1 } 290 291cc6kxbarLcdBannerBanner OBJECT-TYPE 292 SYNTAX DisplayString 293 MAX-ACCESS read-write 294 STATUS current 295 DESCRIPTION 296 "Message that would be displayed on the fabric card LCD. 297 The size of cc6kxbarLcdBannerBanner should be less than 298 or equal to the cc6kxbarLcdBannerMaxSize value." 299 ::= { cc6kxbarLcdBannerEntry 2 } 300 301cc6kxbarLcdBannerMaxSize OBJECT-TYPE 302 SYNTAX Unsigned32 303 MAX-ACCESS read-only 304 STATUS current 305 DESCRIPTION 306 "Maximum size of the associated cc6kxbarLcdBannerBanner 307 object." 308 ::= { cc6kxbarLcdBannerEntry 3 } 309 310 311 312cc6kxbarTruncatedModeOper OBJECT-TYPE 313 SYNTAX TruthValue 314 MAX-ACCESS read-only 315 STATUS current 316 DESCRIPTION 317 "Indicates if the truncated mode is 318 operationally enabled on the device or not. 319 'true' - With the fabric module present in the system, 320 cc6kxbarModuleModeSwitchingMode will be 321 'crossbarmode' for all the fabric capable 322 modules. 323 'false'- With the cc6kxbarMinFabricPresent fabric capable 324 modules and the fabric module present in the system, 325 cc6kxbarModuleModeSwitchingMode 326 will be 'crossbarmode' for fabric capable modules." 327 ::= { cc6kxbarConfiguration 6 } 328 329cc6kxbarDcefOnlyModeAllowed OBJECT-TYPE 330 SYNTAX TruthValue 331 MAX-ACCESS read-write 332 STATUS current 333 DESCRIPTION 334 "Indicates whether the dcef mode is enabled on the standby 335 supervisor or not. 336 'true' - Setting cc6kxbarDcefOnlyModeAllowed to 'true' 337 makes the cc6kxbarModuleModeSwitchingMode of 338 all the active modules to 'dcefmode'. 339 With the active fabric module present in the system, 340 with the switch being in stateful switchover mode, 341 with all the cards that has no distributed Cisco 342 Express forwarding switching support being 343 powered down and on some platforms with standby 344 supervisor ports being shutdown, changing 345 cc6kxbarDcefOnlyModeAllowed to 'true' will make the 346 standby supervisor module reloaded and booted up 347 as distributed forwarding module. 348 'false'- Setting cc6kxbarDcefOnlyModeAllowed to 'false' 349 makes the cc6kxbarModuleModeSwitchingMode of the 350 standby supervisor module to the default value. 351 Changing cc6kxbarDcefOnlyModeAllowed to 'false' 352 will make the standby supervisor reloaded and booted 353 up with the default cc6kxbarModuleModeSwitchingMode." 354 ::= { cc6kxbarConfiguration 7 } 355 356cc6kxbarForceBusMode OBJECT-TYPE 357 SYNTAX TruthValue 358 MAX-ACCESS read-write 359 STATUS current 360 DESCRIPTION 361 "Indicates whether some affected modules are forced to be in 362 'busmode' or not. 363 'true' - Setting cc6kxbarForceBusMode to 'true' makes the 364 cc6kxbarModuleModeSwitchingMode of all 365 the affected modules to 'busmode'. Changing the 366 cc6kxbarForceBusMode to 'true' will make all the 367 affected modules reloaded and booted up as 368 non fabric capable modules. 369 'false'- Setting cc6kxbarForceBusMode to 'false' makes the 370 cc6kxbarModuleModeSwitchingMode of all the affected 371 modules to the default value. Changing 372 cc6kxbarForceBusMode to 'false' will make all the 373 affected modules reloaded and booted up with the 374 default cc6kxbarModuleModeSwitchingMode." 375 ::= { cc6kxbarConfiguration 8 } 376 377cc6kxbarBusOnlyModeOper OBJECT-TYPE 378 SYNTAX TruthValue 379 MAX-ACCESS read-only 380 STATUS current 381 DESCRIPTION 382 "Indicates if the bus mode is operationally enabled on the 383 device or not. 384 385 'true' - Modules are allowed to run in 'busmode'. 386 'false' - None of the modules are allowed to run in 'busmode' 387 i.e., All the non-fabric capable modules will 388 be powered off. Absence of fabric module results 389 in all the fabric capable modules being powered 390 off." 391 ::= { cc6kxbarConfiguration 9 } 392 393-- Status objects 394 395cc6kxbarFabricActiveSlot OBJECT-TYPE 396 SYNTAX ModuleSlotNumber 397 MAX-ACCESS read-only 398 STATUS current 399 DESCRIPTION 400 "cc6kxbarFabricActiveSlot indicates the slot number of the 401 active switching fabric module. A value of zero indicates 402 that the active switching fabric module is either powered 403 down or not present in the chassis." 404 ::= { cc6kxbarStatus 1 } 405 406cc6kxbarFabricBackupSlot OBJECT-TYPE 407 SYNTAX ModuleSlotNumber 408 MAX-ACCESS read-only 409 STATUS current 410 DESCRIPTION 411 "cc6kxbarFabricBackupSlot indicates the slot number of the 412 backup switching fabric module. A value of zero indicates 413 that the backup switching fabric module is either powered 414 down or not present in the chassis." 415 ::= { cc6kxbarStatus 2 } 416 417cc6kxbarModuleModeTable OBJECT-TYPE 418 SYNTAX SEQUENCE OF Cc6kxbarModuleModeEntry 419 MAX-ACCESS not-accessible 420 STATUS current 421 DESCRIPTION 422 "cc6kxbarModuleModeTable indicates the switching mode of each 423 module in the system." 424 ::= { cc6kxbarStatus 3 } 425 426cc6kxbarModuleModeEntry OBJECT-TYPE 427 SYNTAX Cc6kxbarModuleModeEntry 428 MAX-ACCESS not-accessible 429 STATUS current 430 DESCRIPTION 431 "An entry in cc6kxbarModuleModeTable. The agent creates 432 an entry when a non switching fabric module 433 is inserted in the chassis. 434 The agent destroys an entry when a non switching fabric 435 module is power down or reset or removed from the chassis." 436 INDEX { cc6kxbarModuleModeModule } 437 ::= { cc6kxbarModuleModeTable 1 } 438 439Cc6kxbarModuleModeEntry ::= SEQUENCE { 440 cc6kxbarModuleModeModule ModuleSlotNumber, 441 cc6kxbarModuleModeSwitchingMode INTEGER 442} 443 444cc6kxbarModuleModeModule OBJECT-TYPE 445 SYNTAX ModuleSlotNumber 446 MAX-ACCESS not-accessible 447 STATUS current 448 DESCRIPTION 449 "The module slot number." 450 ::= { cc6kxbarModuleModeEntry 1 } 451 452cc6kxbarModuleModeSwitchingMode OBJECT-TYPE 453 SYNTAX INTEGER { 454 busmode(1), 455 crossbarmode(2), 456 dcefmode(3) 457 } 458 MAX-ACCESS read-only 459 STATUS current 460 DESCRIPTION 461 "cc6kxbarModuleModeSwitchingMode indicates switching mode 462 of the cc6kxbarModuleModeModule. 463 'busmode' - Modules in this mode don't use fabric. 464 Backplane is used for both lookup and data 465 forwarding. 466 'crossbarmode' - Modules in this mode use backplane 467 for forwarding decision and fabric for data 468 forwarding 469 'dcefmode' - Modules in this mode use fabric for data 470 forwarding and local forwarding is enabled." 471 ::= { cc6kxbarModuleModeEntry 2 } 472 473 474 475cc6kxbarModuleChannelTable OBJECT-TYPE 476 SYNTAX SEQUENCE OF Cc6kxbarModuleChannelEntry 477 MAX-ACCESS not-accessible 478 STATUS current 479 DESCRIPTION 480 "cc6kxbarModuleChannelTable shows the operational status 481 of fabric channels. This table will be instantiated only when 482 cc6kxbarFabricActiveSlot has a valid value other than zero." 483 ::= { cc6kxbarStatus 4 } 484 485cc6kxbarModuleChannelEntry OBJECT-TYPE 486 SYNTAX Cc6kxbarModuleChannelEntry 487 MAX-ACCESS not-accessible 488 STATUS current 489 DESCRIPTION 490 "An entry in cc6kxbarModuleChannelTable." 491 INDEX { 492 cc6kxbarModuleChannelModule, 493 cc6kxbarModuleChannelChannel 494 } 495 ::= { cc6kxbarModuleChannelTable 1 } 496 497Cc6kxbarModuleChannelEntry ::= SEQUENCE { 498 cc6kxbarModuleChannelModule ModuleSlotNumber, 499 cc6kxbarModuleChannelChannel FabricChannelNumber, 500 cc6kxbarModuleChannelModStatus ChannelStatus, 501 cc6kxbarModuleChannelFabStatus ChannelStatus, 502 cc6kxbarModuleChannelSpeed Gauge32 503} 504 505cc6kxbarModuleChannelModule OBJECT-TYPE 506 SYNTAX ModuleSlotNumber 507 MAX-ACCESS not-accessible 508 STATUS current 509 DESCRIPTION 510 "The module slot number." 511 ::= { cc6kxbarModuleChannelEntry 1 } 512 513cc6kxbarModuleChannelChannel OBJECT-TYPE 514 SYNTAX FabricChannelNumber 515 MAX-ACCESS not-accessible 516 STATUS current 517 DESCRIPTION 518 "Fabric channel number of the cc6kxbarModuleChannelModule." 519 ::= { cc6kxbarModuleChannelEntry 2 } 520 521cc6kxbarModuleChannelModStatus OBJECT-TYPE 522 SYNTAX ChannelStatus 523 MAX-ACCESS read-only 524 STATUS current 525 DESCRIPTION 526 "The status of the fabric channel at the 527 cc6kxbarModuleChannelModule." 528 ::= { cc6kxbarModuleChannelEntry 3 } 529 530cc6kxbarModuleChannelFabStatus OBJECT-TYPE 531 SYNTAX ChannelStatus 532 MAX-ACCESS read-only 533 STATUS current 534 DESCRIPTION 535 "The status of the fabric channel at the 536 cc6kxbarFabricActiveSlot." 537 ::= { cc6kxbarModuleChannelEntry 4 } 538 539cc6kxbarModuleChannelSpeed OBJECT-TYPE 540 SYNTAX Gauge32 541 MAX-ACCESS read-only 542 STATUS current 543 DESCRIPTION 544 "The speed in mega bits per second of the 545 cc6kxbarModuleChannelChannel for cc6kxbarModuleChannelModule." 546 ::= { cc6kxbarModuleChannelEntry 5 } 547 548 549-- Statistics Objects 550 551cc6kxbarStatisticsTable OBJECT-TYPE 552 SYNTAX SEQUENCE OF Cc6kxbarStatisticsEntry 553 MAX-ACCESS not-accessible 554 STATUS current 555 DESCRIPTION 556 "cc6kxbarStatisticsTable gives the 557 fabric channel counters and utilization 558 information. This table will be instantiated when 559 cc6kxbarFabricActiveSlot has a valid value other than 560 zero." 561 ::= { cc6kxbarStatistics 1 } 562 563cc6kxbarStatisticsEntry OBJECT-TYPE 564 SYNTAX Cc6kxbarStatisticsEntry 565 MAX-ACCESS not-accessible 566 STATUS current 567 DESCRIPTION 568 "An entry in cc6kxbarStatisticsTable." 569 INDEX { 570 cc6kxbarStatisticsModule, 571 cc6kxbarStatisticsChannel 572 } 573 ::= { cc6kxbarStatisticsTable 1 } 574 575Cc6kxbarStatisticsEntry ::= SEQUENCE { 576 cc6kxbarStatisticsModule ModuleSlotNumber, 577 cc6kxbarStatisticsChannel FabricChannelNumber, 578 cc6kxbarStatisticsInErrors Counter32, 579 cc6kxbarStatisticsOutErrors Counter32, 580 cc6kxbarStatisticsOutDropped Counter32, 581 cc6kxbarStatisticsInUtil Percent, 582 cc6kxbarStatisticsOutUtil Percent, 583 cc6kxbarStatisticsPeakInUtil Percent, 584 cc6kxbarStatisticsPeakTmInUtil DateAndTime, 585 cc6kxbarStatisticsPeakOutUtil Percent, 586 cc6kxbarStatisticsPeakTmOutUtil DateAndTime, 587 cc6kxbarStatisticsLbusDrops Counter32 588} 589 590cc6kxbarStatisticsModule OBJECT-TYPE 591 SYNTAX ModuleSlotNumber 592 MAX-ACCESS not-accessible 593 STATUS current 594 DESCRIPTION 595 "The module slot number." 596 ::= { cc6kxbarStatisticsEntry 1 } 597 598cc6kxbarStatisticsChannel OBJECT-TYPE 599 SYNTAX FabricChannelNumber 600 MAX-ACCESS not-accessible 601 STATUS current 602 DESCRIPTION 603 "Fabric channel number associated with the 604 cc6kxbarStatisticsModule." 605 ::= { cc6kxbarStatisticsEntry 2 } 606 607cc6kxbarStatisticsInErrors OBJECT-TYPE 608 SYNTAX Counter32 609 MAX-ACCESS read-only 610 STATUS current 611 DESCRIPTION 612 "The total number of error packets received on 613 cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule 614 since this entry was last initialized." 615 ::= { cc6kxbarStatisticsEntry 3 } 616 617cc6kxbarStatisticsOutErrors OBJECT-TYPE 618 SYNTAX Counter32 619 MAX-ACCESS read-only 620 STATUS current 621 DESCRIPTION 622 "The total number of error packets transmitted on 623 cc6kxbarStatisticsModule through the 624 cc6kxbarStatisticsChannel since this entry was 625 last initialized." 626 ::= { cc6kxbarStatisticsEntry 4 } 627 628cc6kxbarStatisticsOutDropped OBJECT-TYPE 629 SYNTAX Counter32 630 MAX-ACCESS read-only 631 STATUS current 632 DESCRIPTION 633 "The total number of dropped packets transmitted on the 634 cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule 635 since this entry was last initialized." 636 ::= { cc6kxbarStatisticsEntry 5 } 637 638cc6kxbarStatisticsInUtil OBJECT-TYPE 639 SYNTAX Percent 640 MAX-ACCESS read-only 641 STATUS current 642 DESCRIPTION 643 "Input utilization of the cc6kxbarStatisticsChannel for 644 cc6kxbarStatisticsModule." 645 ::= { cc6kxbarStatisticsEntry 6 } 646 647cc6kxbarStatisticsOutUtil OBJECT-TYPE 648 SYNTAX Percent 649 MAX-ACCESS read-only 650 STATUS current 651 DESCRIPTION 652 "Output utilization of the cc6kxbarStatisticsChannel for 653 cc6kxbarStatisticsModule." 654 ::= { cc6kxbarStatisticsEntry 7 } 655 656cc6kxbarStatisticsPeakInUtil OBJECT-TYPE 657 SYNTAX Percent 658 MAX-ACCESS read-only 659 STATUS current 660 DESCRIPTION 661 "Indicates the peak value of cc6kxbarStatisticsInUtil of the 662 cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule." 663 ::= { cc6kxbarStatisticsEntry 8 } 664 665cc6kxbarStatisticsPeakTmInUtil OBJECT-TYPE 666 SYNTAX DateAndTime 667 MAX-ACCESS read-only 668 STATUS current 669 DESCRIPTION 670 "Indicates the time of most recent change in the corresponding 671 instance value of cc6kxbarStatisticsPeakInUtil. 672 673 This object contains value 0x0000010100000000 when the 674 corresponding instance value of cc6kxbarStatisticsPeakInUtil 675 is '0'." 676 ::= { cc6kxbarStatisticsEntry 9 } 677 678cc6kxbarStatisticsPeakOutUtil OBJECT-TYPE 679 SYNTAX Percent 680 MAX-ACCESS read-only 681 STATUS current 682 DESCRIPTION 683 "Indicates the peak value of cc6kxbarStatisticsOutUtil of the 684 cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule." 685 ::= { cc6kxbarStatisticsEntry 10 } 686 687cc6kxbarStatisticsPeakTmOutUtil OBJECT-TYPE 688 SYNTAX DateAndTime 689 MAX-ACCESS read-only 690 STATUS current 691 DESCRIPTION 692 "Indicates the time of most recent change in the corresponding 693 instance value of cc6kxbarStatisticsPeakOutUtil. 694 695 This object contains value 0x0000010100000000 when the 696 corresponding instance value of cc6kxbarStatisticsPeakOutUtil 697 is '0'." 698 ::= { cc6kxbarStatisticsEntry 11 } 699 700cc6kxbarStatisticsLbusDrops OBJECT-TYPE 701 SYNTAX Counter32 702 MAX-ACCESS read-only 703 STATUS current 704 DESCRIPTION 705 "This object indicates the number of packets that have been 706 deterministically dropped due to the threshold on the local 707 bus FIFO, errors and exception conditions." 708 ::= { cc6kxbarStatisticsEntry 12 } 709 710 711 712cc6kxbarErrorTable OBJECT-TYPE 713 SYNTAX SEQUENCE OF Cc6kxbarErrorEntry 714 MAX-ACCESS not-accessible 715 STATUS current 716 DESCRIPTION 717 "cc6kxbarErrorTable provides the fabric channel error 718 information. This table will be instantiated only when 719 cc6kxbarFabricActiveSlot has a valid value other than zero." 720 ::= { cc6kxbarStatistics 2 } 721 722cc6kxbarErrorEntry OBJECT-TYPE 723 SYNTAX Cc6kxbarErrorEntry 724 MAX-ACCESS not-accessible 725 STATUS current 726 DESCRIPTION 727 "An entry in cc6kxbarErrorTable for a specific fabric channel 728 on a specific module." 729 INDEX { 730 cc6kxbarErrorModule, 731 cc6kxbarErrorChannel 732 } 733 ::= { cc6kxbarErrorTable 1 } 734 735Cc6kxbarErrorEntry ::= SEQUENCE { 736 cc6kxbarErrorModule ModuleSlotNumber, 737 cc6kxbarErrorChannel FabricChannelNumber, 738 cc6kxbarErrorModuleCrc Gauge32, 739 cc6kxbarErrorModuleHbeat Gauge32, 740 cc6kxbarErrorModuleSync Gauge32, 741 cc6kxbarErrorModuleDDRSync Gauge32, 742 cc6kxbarErrorChannelSync Gauge32, 743 cc6kxbarErrorChannelBuffer Gauge32, 744 cc6kxbarErrorChannelTimeout Gauge32 745} 746 747cc6kxbarErrorModule OBJECT-TYPE 748 SYNTAX ModuleSlotNumber 749 MAX-ACCESS not-accessible 750 STATUS current 751 DESCRIPTION 752 "The module slot number." 753 ::= { cc6kxbarErrorEntry 1 } 754 755cc6kxbarErrorChannel OBJECT-TYPE 756 SYNTAX FabricChannelNumber 757 MAX-ACCESS not-accessible 758 STATUS current 759 DESCRIPTION 760 "Fabric channel number associated with the 761 cc6kxbarErrorModule." 762 ::= { cc6kxbarErrorEntry 2 } 763 764cc6kxbarErrorModuleCrc OBJECT-TYPE 765 SYNTAX Gauge32 766 MAX-ACCESS read-only 767 STATUS current 768 DESCRIPTION 769 "Indicates the total number of CRC error packets for the 770 cc6kxbarErrorChannel of the cc6kxbarErrorModule." 771 ::= { cc6kxbarErrorEntry 3 } 772 773cc6kxbarErrorModuleHbeat OBJECT-TYPE 774 SYNTAX Gauge32 775 MAX-ACCESS read-only 776 STATUS current 777 DESCRIPTION 778 "Indicates the total number of heartbeat misses detected 779 for the cc6kxbarErrorChannel of the cc6kxbarErrorModule." 780 ::= { cc6kxbarErrorEntry 4 } 781 782cc6kxbarErrorModuleSync OBJECT-TYPE 783 SYNTAX Gauge32 784 MAX-ACCESS read-only 785 STATUS current 786 DESCRIPTION 787 "Indicates the total number of times cc6kxbarErrorModule could 788 not sync to the active switching fabric module." 789 ::= { cc6kxbarErrorEntry 5 } 790 791cc6kxbarErrorModuleDDRSync OBJECT-TYPE 792 SYNTAX Gauge32 793 MAX-ACCESS read-only 794 STATUS current 795 DESCRIPTION 796 "Indicates the total number of DDR(Double Data Rate) channel 797 sync errors for the cc6kxbarErrorChannel of the 798 cc6kxbarErrorModule." 799 ::= { cc6kxbarErrorEntry 6 } 800 801cc6kxbarErrorChannelSync OBJECT-TYPE 802 SYNTAX Gauge32 803 MAX-ACCESS read-only 804 STATUS current 805 DESCRIPTION 806 "Indicates the total number of sync errors received at 807 cc6kxbarErrorChannel." 808 ::= { cc6kxbarErrorEntry 7 } 809 810cc6kxbarErrorChannelBuffer OBJECT-TYPE 811 SYNTAX Gauge32 812 MAX-ACCESS read-only 813 STATUS current 814 DESCRIPTION 815 "Indicates the total number of times the memory buffer for 816 cc6kxbarErrorChannel of the cc6kxbarErrorModule is full." 817 ::= { cc6kxbarErrorEntry 8 } 818 819cc6kxbarErrorChannelTimeout OBJECT-TYPE 820 SYNTAX Gauge32 821 MAX-ACCESS read-only 822 STATUS current 823 DESCRIPTION 824 "Indicates the total number of timeouts for input from 825 the cc6kxbarErrorChannel of the cc6kxbarErrorModule." 826 ::= { cc6kxbarErrorEntry 9 } 827 828 829 830-- Switching Bus Objects 831 832cc6kxbarSwBusSwitchingStatus OBJECT-TYPE 833 SYNTAX INTEGER { 834 normal(1), 835 stalled(2), 836 isolated(3) 837 } 838 MAX-ACCESS read-only 839 STATUS current 840 DESCRIPTION 841 "Indicates the current switching status of the 842 switching bus on the system. 843 844 normal -- the switching bus is under normal 845 packet switching operation. 846 847 stalled -- the switching bus has stopped packet 848 switching but is still attached to 849 the system, i.e., the switching bus 850 is stalled. 851 852 isolated -- the switching bus has stopped packet 853 switching and is detached from 854 the system, i.e., the switching bus 855 is isolated. 856 857 The object is only instantiated on systems which 858 support switching bus switching detection feature." 859 ::= { cc6kxbarSwBusObjects 1 } 860 861cc6kxbarSwBusFailureDuration OBJECT-TYPE 862 SYNTAX Unsigned32 863 UNITS "seconds" 864 MAX-ACCESS read-only 865 STATUS current 866 DESCRIPTION 867 "Indicates the failure duration of the switching 868 bus since the switching bus has transitioned 869 out of the normal(1) state as monitored by 870 cc6kxbarSwBusSwitchingStatus. If the object 871 value of cc6kxbarSwBusSwitchingStatus is 872 normal(1), then the object value of 873 cc6kxbarSwBusFailureDuration should be zero. 874 875 The object is only instantiated on systems which 876 support switching bus switching detection feature." 877 ::= { cc6kxbarSwBusObjects 2 } 878 879cc6kxbarSwBusNotifEnable OBJECT-TYPE 880 SYNTAX TruthValue 881 MAX-ACCESS read-write 882 STATUS current 883 DESCRIPTION 884 "Indicates whether or not the notification 885 cc6kxbarSwBusStatusChangeNotif should be generated 886 when there is change in the switching status of the 887 switching bus as monitored by 888 cc6kxbarSwBusSwitchingStatus. 889 890 The object is only instantiated on systems which 891 support switching bus switching detection feature." 892 ::= { cc6kxbarSwBusObjects 3 } 893 894cc6kxbarSwBusUtilization OBJECT-TYPE 895 SYNTAX Percent 896 MAX-ACCESS read-only 897 STATUS current 898 DESCRIPTION 899 "Indicates the percentage of bandwidth utilization 900 of the switching bus." 901 ::= { cc6kxbarSwBusObjects 4 } 902 903cc6kxbarSwBusPeakUtilization OBJECT-TYPE 904 SYNTAX Percent 905 MAX-ACCESS read-only 906 STATUS current 907 DESCRIPTION 908 "Indicates the peak percentage value of bandwidth 909 utilization of the switching bus since the system 910 started." 911 ::= { cc6kxbarSwBusObjects 5 } 912 913cc6kxbarSwBusPeakTimeUtil OBJECT-TYPE 914 SYNTAX DateAndTime 915 MAX-ACCESS read-only 916 STATUS current 917 DESCRIPTION 918 "Indicates the time at which the peak percentage value 919 of bandwidth utilization of the switching bus value 920 occurred." 921 ::= { cc6kxbarSwBusObjects 6 } 922 923-- Internal Bus Objects 924 925cc6kxbarIntBusNotifEnable OBJECT-TYPE 926 SYNTAX BITS { 927 intBusCRCErrExcd(0), 928 intBusCRCErrRcvrd(1) 929 } 930 MAX-ACCESS read-write 931 STATUS current 932 DESCRIPTION 933 "Indicates whether the generation of a specified 934 notification for internal bus is enabled or not. 935 If a bit corresponding to a notification is set to 936 1, then that notification can be generated. 937 938 intBusCRCErrExcd -- the cc6kxbarIntBusCRCErrExcdNotif 939 notification. 940 941 intBusCRCErrRcvrd -- the cc6kxbarIntBusCRCErrRcvrdNotif 942 notification." 943 ::= { cc6kxbarIntBusObjects 1 } 944 945cc6kxbarIntBusCRCErrTable OBJECT-TYPE 946 SYNTAX SEQUENCE OF Cc6kxbarIntBusCRCErrEntry 947 MAX-ACCESS not-accessible 948 STATUS current 949 DESCRIPTION 950 "A table containing internal bus CRC error information 951 on a list of physical entities (such as modules)." 952 ::= { cc6kxbarIntBusObjects 2 } 953 954cc6kxbarIntBusCRCErrEntry OBJECT-TYPE 955 SYNTAX Cc6kxbarIntBusCRCErrEntry 956 MAX-ACCESS not-accessible 957 STATUS current 958 DESCRIPTION 959 "An entry containing internal bus CRC error information 960 on a physical entity (such as a module)." 961 INDEX { entPhysicalIndex } 962 ::= { cc6kxbarIntBusCRCErrTable 1 } 963 964Cc6kxbarIntBusCRCErrEntry ::= SEQUENCE { 965 cc6kxbarIntBusCRCErrExcdStatus TruthValue, 966 cc6kxbarIntBusCRCErrExcdCount Unsigned32 967} 968 969cc6kxbarIntBusCRCErrExcdStatus OBJECT-TYPE 970 SYNTAX TruthValue 971 MAX-ACCESS read-only 972 STATUS current 973 DESCRIPTION 974 "Indicates whether the internal bus CRC error 975 on a physical entity is currently exceeding the fatal 976 threshold or not." 977 ::= { cc6kxbarIntBusCRCErrEntry 1 } 978 979cc6kxbarIntBusCRCErrExcdCount OBJECT-TYPE 980 SYNTAX Unsigned32 981 MAX-ACCESS read-only 982 STATUS current 983 DESCRIPTION 984 "Indicates the number of times the internal bus CRC 985 error on a physical entity has exceeded the fatal 986 threshold." 987 ::= { cc6kxbarIntBusCRCErrEntry 2 } 988 989 990 991-- Flow Control Objects 992 993cc6kxbarFlowCtrlNotifEnable OBJECT-TYPE 994 SYNTAX BITS { 995 busThreshExcd(0) 996 } 997 MAX-ACCESS read-write 998 STATUS current 999 DESCRIPTION 1000 "Specifies whether the generation of a specified 1001 notification for flow control feature is enabled or 1002 not. If a bit corresponding to a notification is set 1003 to one, then that notification can be generated. 1004 1005 busThreshExcd -- the cc6kxbarFlowCtrlBusThrExcdNotif 1006 notification." 1007 ::= { cc6kxbarFlowCtrlObjects 1 } 1008 1009cc6kxbarFlowCtrlBusFIFOThrMode OBJECT-TYPE 1010 SYNTAX INTEGER { 1011 off(1), 1012 on(2), 1013 auto(3) 1014 } 1015 MAX-ACCESS read-write 1016 STATUS current 1017 DESCRIPTION 1018 "Specifies the mode configuration of the system bus 1019 flow control FIFO threshold. 1020 1021 off -- the flow control FIFO threshold is set to the 1022 original value defined by the system. 1023 1024 on -- the flow control FIFO threshold is set to the 1025 lower value defined by the system. 1026 1027 auto -- the system starts monitoring the system bus 1028 flow control FIFO threshold and will change the 1029 flow control FIFO threshold from the original 1030 value to the lower value when the system detects 1031 the first occurrence of the threshold exceeding 1032 on a physical entity (such as a module) over 1033 the system allowed limit." 1034 ::= { cc6kxbarFlowCtrlObjects 2 } 1035 1036cc6kxbarFlowCtrlBusFIFOThrValue OBJECT-TYPE 1037 SYNTAX INTEGER { 1038 original(1), 1039 lower(2) 1040 } 1041 MAX-ACCESS read-only 1042 STATUS current 1043 DESCRIPTION 1044 "Indicates the current value of the system bus flow 1045 control FIFO threshold, whether it is the original 1046 value or the lower value." 1047 ::= { cc6kxbarFlowCtrlObjects 3 } 1048 1049cc6kxbarFlowCtrlBusFIFOTransTime OBJECT-TYPE 1050 SYNTAX TimeStamp 1051 MAX-ACCESS read-only 1052 STATUS current 1053 DESCRIPTION 1054 "Indicates the value of sysUpTime at the time 1055 that the system bus flow control FIFO threshold 1056 is transitioned to lower value when the object value 1057 of cc6kxbarFlowCtrlBusFIFOThrValue is 'lower'. This 1058 object will take on the value of zero when the object 1059 value of cc6kxbarFlowCtrlBusFIFOThrValue is 1060 'original'." 1061 ::= { cc6kxbarFlowCtrlObjects 4 } 1062 1063-- System Capacity Objects 1064 1065cc6kxbarSysCapPfcOperMode OBJECT-TYPE 1066 SYNTAX INTEGER { 1067 unknown(1), 1068 pfc3a(2), 1069 pfc3b(3), 1070 pfc3bxl(4), 1071 pfc3cst1(5), 1072 pfc3cxlst1(6), 1073 pfc3c(7), 1074 pfc3cxl(8), 1075 pfc4(9), 1076 pfc4xl(10), 1077 pfc4xxl(11), 1078 pfc4lite(12) 1079 } 1080 MAX-ACCESS read-only 1081 STATUS current 1082 DESCRIPTION 1083 "Indicates the operating mode of the policy feature 1084 card (PFC). 1085 1086 unknown -- unknown. 1087 1088 pfc3a -- Policy feature card 3A. 1089 1090 pfc3b -- Policy feature card 3B. 1091 1092 pfc3bxl -- Policy feature card 3B XL. 1093 1094 pfc3cst1 -- Policy feature card 3C ST1. 1095 1096 pfc3cxlst1 -- Policy feature card 3C XL ST1. 1097 1098 pfc3c -- Policy feature card 3C. 1099 1100 pfc3cxl -- Policy feature card 3C XL. 1101 1102 pfc4 -- Policy feature card 4. 1103 1104 pfc4xl -- Policy feature card 4 XL. 1105 1106 pfc4xxl -- Policy feature card 4 XXL. 1107 1108 pfc4lite -- Policy feature card 4 Lite." 1109 ::= { cc6kxbarSystemCapacityObjects 1 } 1110 1111cc6kxbarSysCapSwitchResTable OBJECT-TYPE 1112 SYNTAX SEQUENCE OF Cc6kxbarSysCapSwitchResEntry 1113 MAX-ACCESS not-accessible 1114 STATUS current 1115 DESCRIPTION 1116 "A cc6kxbarSysCapSwitchResTable entry lists 1117 the capacity information of the switching 1118 resources for ENTITY-MIB entPhysicalTable entries 1119 of manageable components with type entPhysicalClass 1120 module(9)." 1121 ::= { cc6kxbarSystemCapacityObjects 2 } 1122 1123cc6kxbarSysCapSwitchResEntry OBJECT-TYPE 1124 SYNTAX Cc6kxbarSysCapSwitchResEntry 1125 MAX-ACCESS not-accessible 1126 STATUS current 1127 DESCRIPTION 1128 "A cc6kxbarSysCapSwitchResEntry entry lists 1129 the capacity information of the switching 1130 resources for ENTITY-MIB entPhysicalTable entries 1131 of manageable components with type entPhysicalClass 1132 module(9). 1133 1134 Entries are created by the agent at the system power-up 1135 or module insertion. 1136 1137 Entries are deleted by the agent upon module removal." 1138 INDEX { entPhysicalIndex } 1139 ::= { cc6kxbarSysCapSwitchResTable 1 } 1140 1141Cc6kxbarSysCapSwitchResEntry ::= SEQUENCE { 1142 cc6kxbarSysCapSwitchResSeries INTEGER, 1143 cc6kxbarSysCapSwitchResCefMode INTEGER 1144} 1145 1146cc6kxbarSysCapSwitchResSeries OBJECT-TYPE 1147 SYNTAX INTEGER { 1148 unknown(1), 1149 supervisor(2), 1150 classic(3), 1151 fabric(4), 1152 dcef720(5), 1153 cef720(6), 1154 dcef256(7), 1155 cef256(8) 1156 } 1157 MAX-ACCESS read-only 1158 STATUS current 1159 DESCRIPTION 1160 "Indicates the module series for traffic forwarding options. 1161 1162 unknown -- unknown. 1163 1164 supervisor -- supervisor module. 1165 1166 classic -- classic module. 1167 1168 fabric -- fabric module. 1169 1170 dcef720 -- dCEF720 module. 1171 1172 cef720 -- CEF720 module. 1173 1174 dcef256 -- dCEF256 module. 1175 1176 cef256 -- CEF256 module." 1177 ::= { cc6kxbarSysCapSwitchResEntry 1 } 1178 1179cc6kxbarSysCapSwitchResCefMode OBJECT-TYPE 1180 SYNTAX INTEGER { 1181 notApplicable(1), 1182 dcef(2), 1183 cef(3) 1184 } 1185 MAX-ACCESS read-only 1186 STATUS current 1187 DESCRIPTION 1188 "Indicates the Cisco Express Forwarding (CEF) mode of 1189 the module. 1190 1191 notApplicable -- not applicable for this module. 1192 1193 dcef -- distributed CEF. 1194 1195 cef -- CEF." 1196 ::= { cc6kxbarSysCapSwitchResEntry 2 } 1197 1198 1199 1200-- Fabric Error Recovery Objects 1201 1202cc6kxbarErrRcvryThreshLink OBJECT-TYPE 1203 SYNTAX Unsigned32 (1..4294967295) 1204 MAX-ACCESS read-write 1205 STATUS current 1206 DESCRIPTION 1207 "Specifies the threshold on fabric link errors occurring 1208 in a channel for the fabric error recovery feature." 1209 ::= { cc6kxbarErrorRecoveryObjects 1 } 1210 1211cc6kxbarErrRcvryThreshPersLink OBJECT-TYPE 1212 SYNTAX Unsigned32 (1..4294967295) 1213 MAX-ACCESS read-write 1214 STATUS current 1215 DESCRIPTION 1216 "Specifies the threshold on persistent fabric link errors 1217 occurring in a channel for the fabric error recovery feature." 1218 ::= { cc6kxbarErrorRecoveryObjects 2 } 1219 1220cc6kxbarErrRcvrySwitchoverEnable OBJECT-TYPE 1221 SYNTAX TruthValue 1222 MAX-ACCESS read-write 1223 STATUS current 1224 DESCRIPTION 1225 "Specifies whether the switchover to the standby fabric module 1226 is enabled or not on the detection of excessive fabric link 1227 errors occurring in a channel for the fabric error recovery 1228 feature." 1229 ::= { cc6kxbarErrorRecoveryObjects 3 } 1230 1231cc6kxbarErrRcvryPersLinkResync OBJECT-TYPE 1232 SYNTAX TruthValue 1233 MAX-ACCESS read-write 1234 STATUS current 1235 DESCRIPTION 1236 "Specifies whether the system will resync the channel or not 1237 on the detection of excessive persistent fabric link errors 1238 in a channel for the fabric error recovery feature." 1239 ::= { cc6kxbarErrorRecoveryObjects 4 } 1240 1241cc6kxbarErrRcvryChResyncCount OBJECT-TYPE 1242 SYNTAX Unsigned32 (1..4294967295) 1243 MAX-ACCESS read-write 1244 STATUS current 1245 DESCRIPTION 1246 "Specifies the consecutive number of times of 1247 channel resync within the time interval as specified 1248 by cc6kxbarErrRcvryChResyncInterval, over which 1249 the channel resync is considered as failure 1250 for the fabric error recovery feature." 1251 ::= { cc6kxbarErrorRecoveryObjects 5 } 1252 1253cc6kxbarErrRcvryChResyncInterval OBJECT-TYPE 1254 SYNTAX Unsigned32 (1..4294967295) 1255 UNITS "milliseconds" 1256 MAX-ACCESS read-write 1257 STATUS current 1258 DESCRIPTION 1259 "Specifies the time interval for the consecutive 1260 counting of channel resync for the fabric error 1261 recovery feature." 1262 ::= { cc6kxbarErrorRecoveryObjects 6 } 1263 1264-- Traffic Monitor Objects 1265 1266cc6kxbarTMSwBusUtilEnable OBJECT-TYPE 1267 SYNTAX TruthValue 1268 MAX-ACCESS read-write 1269 STATUS current 1270 DESCRIPTION 1271 "Specifies whether the traffic monitor feature is 1272 enabled on the switching bus or not." 1273 ::= { cc6kxbarTrafficMonitorSwBusObjects 1 } 1274 1275cc6kxbarTMSwBusUtilInterval OBJECT-TYPE 1276 SYNTAX Unsigned32 (1..4294967295) 1277 UNITS "seconds" 1278 MAX-ACCESS read-write 1279 STATUS current 1280 DESCRIPTION 1281 "Specifies the interval at the end of which 1282 the switching bus traffic utilization is compared 1283 against cc6kxbarTMSwBusUtilThreshold." 1284 ::= { cc6kxbarTrafficMonitorSwBusObjects 2 } 1285 1286cc6kxbarTMSwBusUtilThreshold OBJECT-TYPE 1287 SYNTAX Percent 1288 MAX-ACCESS read-write 1289 STATUS current 1290 DESCRIPTION 1291 "Specifies the threshold of the switching bus 1292 traffic utilization." 1293 ::= { cc6kxbarTrafficMonitorSwBusObjects 3 } 1294 1295cc6kxbarTMSwBusUtilLogCount OBJECT-TYPE 1296 SYNTAX Counter32 1297 MAX-ACCESS read-only 1298 STATUS current 1299 DESCRIPTION 1300 "Indicates the number of times the following 1301 events are logged for the switching bus: 1302 1303 1. the switching bus traffic utilization has 1304 risen above the configured threshold (as 1305 specified by cc6kxbarTMSwBusUtilThreshold), 1306 or has kept staying above the configured 1307 threshold at a logging interval (as specified 1308 by cc6kxbarTMSwBusUtilLogInterval). 1309 1310 2. the switching bus traffic utilization 1311 has fallen below the configured threshold." 1312 ::= { cc6kxbarTrafficMonitorSwBusObjects 4 } 1313 1314cc6kxbarTMSwBusUtilLastLogTime OBJECT-TYPE 1315 SYNTAX DateAndTime 1316 MAX-ACCESS read-only 1317 STATUS current 1318 DESCRIPTION 1319 "Indicates the last logging time of the 1320 events as counted in cc6kxbarTMSwBusUtilLogCount. 1321 1322 This object will contain 0-1-1,00:00:00.0 when 1323 the value of cc6kxbarTMSwBusUtilLogCount is zero." 1324 ::= { cc6kxbarTrafficMonitorSwBusObjects 5 } 1325 1326cc6kxbarTMSwBusUtilLogInterval OBJECT-TYPE 1327 SYNTAX Unsigned32 (1..4294967295) 1328 UNITS "seconds" 1329 MAX-ACCESS read-write 1330 STATUS current 1331 DESCRIPTION 1332 "Specifies the logging interval if the switching 1333 bus traffic utilization keeps staying above the 1334 cc6kxbarTMSwBusUtilThreshold." 1335 ::= { cc6kxbarTrafficMonitorSwBusObjects 6 } 1336 1337cc6kxbarTMSwBusUtilUtilization OBJECT-TYPE 1338 SYNTAX Percent 1339 MAX-ACCESS accessible-for-notify 1340 STATUS current 1341 DESCRIPTION 1342 "The switching bus traffic utilization included 1343 in the notification currently being sent." 1344 ::= { cc6kxbarTrafficMonitorSwBusObjects 7 } 1345 1346cc6kxbarTMSwBusUtilNotifEnable OBJECT-TYPE 1347 SYNTAX TruthValue 1348 MAX-ACCESS read-write 1349 STATUS current 1350 DESCRIPTION 1351 "Specifies whether the generation of 1352 c6kxbarTMSwBusUtilAboveNotif and 1353 c6kxbarTMSwBusUtilBelowNotif notifications 1354 is enabled or not. 1355 1356 When this object is 'true', the generation of 1357 cc6kxbarTMSwBusUtilAboveNotif and 1358 c6kxbarTMSwBusUtilBelowNotif notifications is 1359 enabled. When this object is 'false', the 1360 generation of cc6kxbarTMSwBusUtilAboveNotif and 1361 c6kxbarTMSwBusUtilBelowNotif notifications 1362 is disabled." 1363 ::= { cc6kxbarTrafficMonitorSwBusObjects 8 } 1364 1365cc6kxbarTMChUtilTable OBJECT-TYPE 1366 SYNTAX SEQUENCE OF Cc6kxbarTMChUtilEntry 1367 MAX-ACCESS not-accessible 1368 STATUS current 1369 DESCRIPTION 1370 "cc6kxbarTrafficMntrChUtilTable provides the 1371 information on the traffic utilization of each 1372 fabric channel associated with each module slot 1373 for a given traffic direction in the chassis." 1374 ::= { cc6kxbarTrafficMonitorChObjects 1 } 1375 1376cc6kxbarTMChUtilEntry OBJECT-TYPE 1377 SYNTAX Cc6kxbarTMChUtilEntry 1378 MAX-ACCESS not-accessible 1379 STATUS current 1380 DESCRIPTION 1381 "An entry in cc6kxbarTMChUtilTable. Each traffic 1382 direction for each fabric channel associated with 1383 each module slot in the chassis will have an 1384 entry in this table." 1385 INDEX { 1386 cc6kxbarTMChUtilModule, 1387 cc6kxbarTMChUtilChannel, 1388 cc6kxbarTMChUtilDirection 1389 } 1390 ::= { cc6kxbarTMChUtilTable 1 } 1391 1392Cc6kxbarTMChUtilEntry ::= SEQUENCE { 1393 cc6kxbarTMChUtilModule ModuleSlotNumber, 1394 cc6kxbarTMChUtilChannel FabricChannelNumber, 1395 cc6kxbarTMChUtilDirection INTEGER, 1396 cc6kxbarTMChUtilEnable TruthValue, 1397 cc6kxbarTMChUtilInterval Unsigned32, 1398 cc6kxbarTMChUtilThreshold Percent, 1399 cc6kxbarTMChUtilLogCount Counter32, 1400 cc6kxbarTMChUtilLastLogTime DateAndTime 1401} 1402 1403cc6kxbarTMChUtilModule OBJECT-TYPE 1404 SYNTAX ModuleSlotNumber 1405 MAX-ACCESS not-accessible 1406 STATUS current 1407 DESCRIPTION 1408 "Indicates the module slot number in the chassis." 1409 ::= { cc6kxbarTMChUtilEntry 1 } 1410 1411cc6kxbarTMChUtilChannel OBJECT-TYPE 1412 SYNTAX FabricChannelNumber 1413 MAX-ACCESS not-accessible 1414 STATUS current 1415 DESCRIPTION 1416 "Indicates the fabric channel number associated with 1417 the corresponding cc6kxbarTMChUtilModule." 1418 ::= { cc6kxbarTMChUtilEntry 2 } 1419 1420cc6kxbarTMChUtilDirection OBJECT-TYPE 1421 SYNTAX INTEGER { 1422 ingress(1), 1423 egress(2) 1424 } 1425 MAX-ACCESS not-accessible 1426 STATUS current 1427 DESCRIPTION 1428 "Indicates the direction of traffic to be monitored." 1429 ::= { cc6kxbarTMChUtilEntry 3 } 1430 1431cc6kxbarTMChUtilEnable OBJECT-TYPE 1432 SYNTAX TruthValue 1433 MAX-ACCESS read-write 1434 STATUS current 1435 DESCRIPTION 1436 "Specifies whether the traffic monitor feature is 1437 enabled on a fabric channel for a given traffic 1438 direction or not." 1439 ::= { cc6kxbarTMChUtilEntry 4 } 1440 1441cc6kxbarTMChUtilInterval OBJECT-TYPE 1442 SYNTAX Unsigned32 (1..4294967295) 1443 UNITS "seconds" 1444 MAX-ACCESS read-write 1445 STATUS current 1446 DESCRIPTION 1447 "Specifies the interval at the end of which the 1448 traffic utilization on a fabric channel for a 1449 given traffic direction is compared against 1450 its corresponding cc6kxbarTMChUtilThreshold." 1451 ::= { cc6kxbarTMChUtilEntry 5 } 1452 1453cc6kxbarTMChUtilThreshold OBJECT-TYPE 1454 SYNTAX Percent 1455 MAX-ACCESS read-write 1456 STATUS current 1457 DESCRIPTION 1458 "Specifies the threshold of the traffic utilization 1459 on a fabric channel for a given traffic direction." 1460 ::= { cc6kxbarTMChUtilEntry 6 } 1461 1462cc6kxbarTMChUtilLogCount OBJECT-TYPE 1463 SYNTAX Counter32 1464 MAX-ACCESS read-only 1465 STATUS current 1466 DESCRIPTION 1467 "Indicates the number of times the following 1468 events are logged on a fabric channel 1469 for a given direction. 1470 1471 1. the traffic utilization on a fabric channel 1472 for a given traffic direction has risen above its 1473 corresponding configured threshold (as specified 1474 by cc6kxbarTMChUtilThreshold), or has kept 1475 staying above the configured threshold at a 1476 logging interval (as specified by 1477 cc6kxbarTMChUtilLogInterval). 1478 1479 2. the traffic utilization on a fabric channel 1480 for a given traffic direction has fallen below 1481 its corresponding configured threshold." 1482 ::= { cc6kxbarTMChUtilEntry 7 } 1483 1484cc6kxbarTMChUtilLastLogTime OBJECT-TYPE 1485 SYNTAX DateAndTime 1486 MAX-ACCESS read-only 1487 STATUS current 1488 DESCRIPTION 1489 "Indicates the last logging time of the 1490 events as counted in the corresponding 1491 cc6kxbarTMChUtilLogCount on a fabric channel 1492 for a given traffic direction. 1493 1494 This object will contain 0-1-1,00:00:00.0 when 1495 the corresponding cc6kxbarTMChUtilLogCount is zero." 1496 ::= { cc6kxbarTMChUtilEntry 8 } 1497 1498 1499 1500cc6kxbarTMChUtilLogInterval OBJECT-TYPE 1501 SYNTAX Unsigned32 (1..4294967295) 1502 UNITS "seconds" 1503 MAX-ACCESS read-write 1504 STATUS current 1505 DESCRIPTION 1506 "Specifies the logging interval if the traffic 1507 utilization for a fabric channel on a given 1508 traffic direction keeps staying above its 1509 corresponding cc6kxbarTMChUtilThreshold." 1510 ::= { cc6kxbarTrafficMonitorChObjects 2 } 1511 1512cc6kxbarTMChUtilUtilization OBJECT-TYPE 1513 SYNTAX Percent 1514 MAX-ACCESS accessible-for-notify 1515 STATUS current 1516 DESCRIPTION 1517 "The traffic utilization on a fabric channel 1518 for a given traffic direction included in the 1519 notification currently being sent." 1520 ::= { cc6kxbarTrafficMonitorChObjects 3 } 1521 1522cc6kxbarTMChUtilNotifEnable OBJECT-TYPE 1523 SYNTAX TruthValue 1524 MAX-ACCESS read-write 1525 STATUS current 1526 DESCRIPTION 1527 "Specifies whether the generation of 1528 cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif 1529 notifications is enabled or not. 1530 1531 When this object is 'true', the generation of 1532 cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif 1533 notifications is enabled. When this object is 'false', 1534 the generation of cc6kxbarTMChUtilAboveNotif and 1535 cc6kxbarTMChUtilBelowNotif notifications is disabled." 1536 ::= { cc6kxbarTrafficMonitorChObjects 4 } 1537-- Notifications 1538 1539ciscoCat6kXbarMIBNotifs OBJECT IDENTIFIER 1540 ::= { ciscoCat6kCrossbarMIB 0 } 1541 1542 1543cc6kxbarSwBusStatusChangeNotif NOTIFICATION-TYPE 1544 OBJECTS { 1545 cc6kxbarSwBusSwitchingStatus, 1546 cc6kxbarSwBusFailureDuration 1547 } 1548 STATUS current 1549 DESCRIPTION 1550 "A cc6kxbarSwBusStatusChangeNotif notification 1551 is sent by the device when there is change 1552 in switching status of the switching bus as 1553 monitored by cc6kxbarSwBusSwitchingStatus." 1554 ::= { ciscoCat6kXbarMIBNotifs 1 } 1555 1556cc6kxbarIntBusCRCErrExcdNotif NOTIFICATION-TYPE 1557 OBJECTS { 1558 entPhysicalName, 1559 entPhysicalVendorType 1560 } 1561 STATUS current 1562 DESCRIPTION 1563 "A cc6kxbarIntBusCRCThreshExcdNotif notification 1564 is sent by the system when the system has 1565 detected that the internal bus CRC error on 1566 a physical entity (such as a module) as specified 1567 by entPhysicalName has exceeded the fatal threshold." 1568 ::= { ciscoCat6kXbarMIBNotifs 2 } 1569 1570cc6kxbarIntBusCRCErrRcvrdNotif NOTIFICATION-TYPE 1571 OBJECTS { 1572 entPhysicalName, 1573 entPhysicalVendorType 1574 } 1575 STATUS current 1576 DESCRIPTION 1577 "A cc6kxbarIntBusCRCErrRcvrdNotif notification 1578 is sent by the system when the system has 1579 recovered as the internal bus CRC error on 1580 a physical entity (such as a module) as 1581 specified by entPhysicalName has fallen below 1582 the normal threshold." 1583 ::= { ciscoCat6kXbarMIBNotifs 3 } 1584 1585cc6kxbarFlowCtrlBusThrExcdNotif NOTIFICATION-TYPE 1586 OBJECTS { 1587 entPhysicalName, 1588 entPhysicalVendorType 1589 } 1590 STATUS current 1591 DESCRIPTION 1592 "A cc6kxbarFlowCtrlBusThrExcdNotif notification 1593 is sent by the system when the system detects the 1594 first occurrence of the system bus flow control FIFO 1595 threshold exceeding on a physical entity 1596 (such as a module) over the system allowed limit 1597 when the object value of 1598 cc6kxbarFlowCtrlBusFIFOThrMode is 'auto'." 1599 ::= { ciscoCat6kXbarMIBNotifs 4 } 1600 1601cc6kxbarTMSwBusUtilAboveNotif NOTIFICATION-TYPE 1602 OBJECTS { 1603 cc6kxbarTMSwBusUtilUtilization, 1604 cc6kxbarTMSwBusUtilThreshold, 1605 cc6kxbarTMSwBusUtilInterval, 1606 entPhysicalDescr 1607 } 1608 STATUS current 1609 DESCRIPTION 1610 "This notification is sent when the switching bus 1611 traffic utilization has risen above the configured 1612 threshold (as specified by 1613 cc6kxbarTMSwBusUtilThreshold), or has kept staying 1614 above the configured threshold at a logging interval 1615 (as specified by cc6kxbarTMSwBusUtilLogInterval). 1616 The varbind entPhysicalDescr specifies the physical 1617 entity (such as chassis) for which the 1618 cc6kxbarTMSwBusUtilAboveNotif is sent." 1619 ::= { ciscoCat6kXbarMIBNotifs 5 } 1620 1621cc6kxbarTMSwBusUtilBelowNotif NOTIFICATION-TYPE 1622 OBJECTS { 1623 cc6kxbarTMSwBusUtilUtilization, 1624 cc6kxbarTMSwBusUtilThreshold, 1625 cc6kxbarTMSwBusUtilInterval, 1626 entPhysicalDescr 1627 } 1628 STATUS current 1629 DESCRIPTION 1630 "This notification is sent when the switching bus 1631 traffic utilization has fallen below the configured 1632 threshold (as specified by 1633 cc6kxbarTMSwBusUtilThreshold). The varbind 1634 entPhysicalDescr specifies the physical entity 1635 (such as chassis) for which the 1636 cc6kxbarTMSwBusUtilBelowNotif is sent." 1637 ::= { ciscoCat6kXbarMIBNotifs 6 } 1638 1639cc6kxbarTMChUtilAboveNotif NOTIFICATION-TYPE 1640 OBJECTS { 1641 cc6kxbarTMChUtilUtilization, 1642 cc6kxbarTMChUtilThreshold, 1643 cc6kxbarTMChUtilInterval, 1644 entPhysicalDescr 1645 } 1646 STATUS current 1647 DESCRIPTION 1648 "This notification is sent when the traffic 1649 utilization on a fabric channel for a given 1650 traffic direction has risen above its 1651 corresponding configured threshold (as 1652 specified by cc6kxbarTMChUtilThreshold), or has 1653 kept staying above the configured threshold at a 1654 logging interval (as specified by 1655 cc6kxbarTMChUtilLogInterval). The varbind 1656 entPhysicalDescr specifies the physical entity 1657 (such as chassis) for which the 1658 cc6kxbarTMChUtilAboveNotif is sent." 1659 ::= { ciscoCat6kXbarMIBNotifs 7 } 1660 1661cc6kxbarTMChUtilBelowNotif NOTIFICATION-TYPE 1662 OBJECTS { 1663 cc6kxbarTMChUtilUtilization, 1664 cc6kxbarTMChUtilThreshold, 1665 cc6kxbarTMChUtilInterval, 1666 entPhysicalDescr 1667 } 1668 STATUS current 1669 DESCRIPTION 1670 "This notification is sent when the traffic 1671 utilization on a fabric channel for a given 1672 traffic direction has fallen below its 1673 corresponding configured threshold (as 1674 specified by cc6kxbarTMChUtilThreshold). The 1675 varbind entPhysicalDescr specifies the 1676 physical entity (such as chassis) for which 1677 the cc6kxbarTMChUtilBelowNotif is sent." 1678 ::= { ciscoCat6kXbarMIBNotifs 8 } 1679-- Conformance and Compliance 1680 1681cc6kxbarMIBConformance OBJECT IDENTIFIER 1682 ::= { ciscoCat6kCrossbarMIB 3 } 1683 1684cc6kxbarMIBCompliances OBJECT IDENTIFIER 1685 ::= { cc6kxbarMIBConformance 1 } 1686 1687cc6kxbarMIBGroups OBJECT IDENTIFIER 1688 ::= { cc6kxbarMIBConformance 2 } 1689 1690 1691-- Conformance 1692 1693cc6kxbarMIBCompliance MODULE-COMPLIANCE 1694 STATUS deprecated 1695 DESCRIPTION 1696 "The compliance statement for 1697 the CISCO-CAT6K-CROSSBAR-MIB." 1698 MODULE -- this module 1699 MANDATORY-GROUPS { 1700 cc6kxbarModuleStatusGroup, 1701 cc6kxbarChannelStatusGroup, 1702 cc6kxbarChannelStatisticsGroup 1703 } 1704 1705 GROUP cc6kxbarFallbackGroup 1706 DESCRIPTION 1707 "This group is mandatory only for those platforms which 1708 support fallback mode feature." 1709 1710 GROUP cc6kxbarBusOnlyAllowedGroup 1711 DESCRIPTION 1712 "This group is mandatory only for those platforms which 1713 support busonly mode feature." 1714 ::= { cc6kxbarMIBCompliances 2 } 1715 1716cc6kxbarMIBComplianceVer1 MODULE-COMPLIANCE 1717 STATUS deprecated 1718 DESCRIPTION 1719 "The compliance statement for 1720 the CISCO-CAT6K-CROSSBAR-MIB." 1721 MODULE -- this module 1722 MANDATORY-GROUPS { 1723 cc6kxbarModuleStatusGroupVer1, 1724 cc6kxbarChannelStatusGroup, 1725 cc6kxbarChannelStatisticsGroupVer1 1726 } 1727 1728 GROUP cc6kxbarFallbackGroup 1729 DESCRIPTION 1730 "This group is mandatory only for those platforms which 1731 support fallback mode feature." 1732 1733 GROUP cc6kxbarBusOnlyAllowedGroup 1734 DESCRIPTION 1735 "This group is mandatory only for those platforms which 1736 support bus only mode feature." 1737 1738 GROUP cc6kxbarLcdBannerGroup 1739 DESCRIPTION 1740 "This group is mandatory only for those platforms which 1741 support lcd banner feature." 1742 1743 GROUP cc6kxbarChannelUtilGroup 1744 DESCRIPTION 1745 "This group is mandatory only for those platforms which 1746 support Input and Output traffic utilization on the 1747 fabric channel." 1748 1749 GROUP cc6kxbarChannelSpeedGroup 1750 DESCRIPTION 1751 "This group is mandatory only for those platforms which 1752 support fabric channel speed feature." 1753 1754 GROUP cc6kxbarSwBusGroup 1755 DESCRIPTION 1756 "This group is mandatory only for platforms which support 1757 switching bus switching detection feature." 1758 1759 GROUP cc6kxbarSwBusNotifGroup 1760 DESCRIPTION 1761 "This group is mandatory only for platforms which support 1762 switching bus switching detection notification 1763 feature." 1764 ::= { cc6kxbarMIBCompliances 3 } 1765 1766cc6kxbarMIBComplianceVer2 MODULE-COMPLIANCE 1767 STATUS deprecated 1768 DESCRIPTION 1769 "The compliance statement for 1770 the CISCO-CAT6K-CROSSBAR-MIB." 1771 MODULE -- this module 1772 MANDATORY-GROUPS { 1773 cc6kxbarModuleStatusGroupVer1, 1774 cc6kxbarChannelStatusGroup, 1775 cc6kxbarChannelStatisticsGroupVer1 1776 } 1777 1778 GROUP cc6kxbarFallbackGroup 1779 DESCRIPTION 1780 "This group is mandatory only for those platforms which 1781 support fallback mode feature." 1782 1783 GROUP cc6kxbarBusOnlyAllowedGroup 1784 DESCRIPTION 1785 "This group is mandatory only for those platforms which 1786 support bus only mode feature." 1787 1788 GROUP cc6kxbarLcdBannerGroup 1789 DESCRIPTION 1790 "This group is mandatory only for those platforms which 1791 support lcd banner feature." 1792 1793 GROUP cc6kxbarChannelUtilGroup 1794 DESCRIPTION 1795 "This group is mandatory only for those platforms which 1796 support Input and Output traffic utilization on the 1797 fabric channel." 1798 1799 GROUP cc6kxbarChannelSpeedGroup 1800 DESCRIPTION 1801 "This group is mandatory only for those platforms which 1802 support fabric channel speed feature." 1803 1804 GROUP cc6kxbarSwBusGroup 1805 DESCRIPTION 1806 "This group is mandatory only for platforms which support 1807 switching bus switching detection feature." 1808 1809 GROUP cc6kxbarSwBusNotifGroup 1810 DESCRIPTION 1811 "This group is mandatory only for platforms which support 1812 switching bus switching detection notification 1813 feature." 1814 1815 GROUP cc6kxbarTruncatedOperGroup 1816 DESCRIPTION 1817 "This group is mandatory only for platforms which support 1818 operational truncated mode." 1819 ::= { cc6kxbarMIBCompliances 4 } 1820 1821cc6kxbarMIBComplianceVer3 MODULE-COMPLIANCE 1822 STATUS deprecated 1823 DESCRIPTION 1824 "The compliance statement for 1825 the CISCO-CAT6K-CROSSBAR-MIB." 1826 MODULE -- this module 1827 MANDATORY-GROUPS { 1828 cc6kxbarModuleStatusGroupVer1, 1829 cc6kxbarChannelStatusGroup, 1830 cc6kxbarChannelStatisticsGroupVer1 1831 } 1832 1833 GROUP cc6kxbarFallbackGroup 1834 DESCRIPTION 1835 "This group is mandatory only for those platforms which 1836 support fallback mode feature." 1837 1838 GROUP cc6kxbarBusOnlyAllowedGroup 1839 DESCRIPTION 1840 "This group is mandatory only for those platforms which 1841 support bus only mode feature." 1842 1843 GROUP cc6kxbarLcdBannerGroup 1844 DESCRIPTION 1845 "This group is mandatory only for those platforms which 1846 support lcd banner feature." 1847 1848 GROUP cc6kxbarChannelUtilGroup 1849 DESCRIPTION 1850 "This group is mandatory only for those platforms which 1851 support Input and Output traffic utilization on the 1852 fabric channel." 1853 1854 GROUP cc6kxbarChannelSpeedGroup 1855 DESCRIPTION 1856 "This group is mandatory only for those platforms which 1857 support fabric channel speed feature." 1858 1859 GROUP cc6kxbarSwBusGroup 1860 DESCRIPTION 1861 "This group is mandatory only for platforms which support 1862 switching bus switching detection feature." 1863 1864 GROUP cc6kxbarSwBusNotifGroup 1865 DESCRIPTION 1866 "This group is mandatory only for platforms which support 1867 switching bus switching detection notification 1868 feature." 1869 1870 GROUP cc6kxbarTruncatedOperGroup 1871 DESCRIPTION 1872 "This group is mandatory only for platforms which support 1873 operational truncated mode." 1874 1875 GROUP cc6kxbarIntBusNotifControlGroup 1876 DESCRIPTION 1877 "This group is mandatory only for platforms which support 1878 internal bus notifications." 1879 1880 GROUP cc6kxbarIntBusCRCErrNotifGroup 1881 DESCRIPTION 1882 "This group is mandatory only for platforms which support 1883 internal bus CRC error notifications." 1884 ::= { cc6kxbarMIBCompliances 5 } 1885 1886cc6kxbarMIBComplianceVer4 MODULE-COMPLIANCE 1887 STATUS deprecated 1888 DESCRIPTION 1889 "The compliance statement for 1890 the CISCO-CAT6K-CROSSBAR-MIB." 1891 MODULE -- this module 1892 MANDATORY-GROUPS { 1893 cc6kxbarModuleStatusGroupVer1, 1894 cc6kxbarChannelStatusGroup, 1895 cc6kxbarChannelStatisticsGroupVer1 1896 } 1897 1898 GROUP cc6kxbarFallbackGroup 1899 DESCRIPTION 1900 "This group is mandatory only for those platforms which 1901 support fallback mode feature." 1902 1903 GROUP cc6kxbarBusOnlyAllowedGroup 1904 DESCRIPTION 1905 "This group is mandatory only for those platforms which 1906 support bus only mode feature." 1907 1908 GROUP cc6kxbarLcdBannerGroup 1909 DESCRIPTION 1910 "This group is mandatory only for those platforms which 1911 support lcd banner feature." 1912 1913 GROUP cc6kxbarChannelUtilGroup 1914 DESCRIPTION 1915 "This group is mandatory only for those platforms which 1916 support Input and Output traffic utilization on the 1917 fabric channel." 1918 1919 GROUP cc6kxbarChannelSpeedGroup 1920 DESCRIPTION 1921 "This group is mandatory only for those platforms which 1922 support fabric channel speed feature." 1923 1924 GROUP cc6kxbarSwBusGroup 1925 DESCRIPTION 1926 "This group is mandatory only for platforms which support 1927 switching bus switching detection feature." 1928 1929 GROUP cc6kxbarSwBusNotifGroup 1930 DESCRIPTION 1931 "This group is mandatory only for platforms which support 1932 switching bus switching detection notification 1933 feature." 1934 1935 GROUP cc6kxbarTruncatedOperGroup 1936 DESCRIPTION 1937 "This group is mandatory only for platforms which support 1938 operational truncated mode." 1939 1940 GROUP cc6kxbarIntBusNotifControlGroup 1941 DESCRIPTION 1942 "This group is mandatory only for platforms which support 1943 internal bus notifications." 1944 1945 GROUP cc6kxbarIntBusCRCErrNotifGroup 1946 DESCRIPTION 1947 "This group is mandatory only for platforms which support 1948 internal bus CRC error notifications." 1949 1950 GROUP cc6kxbarIntBusCRCErrGroup 1951 DESCRIPTION 1952 "This group is mandatory only for platforms which support 1953 internal bus CRC error status." 1954 ::= { cc6kxbarMIBCompliances 6 } 1955 1956cc6kxbarMIBComplianceVer5 MODULE-COMPLIANCE 1957 STATUS deprecated 1958 DESCRIPTION 1959 "The compliance statement for 1960 the CISCO-CAT6K-CROSSBAR-MIB." 1961 MODULE -- this module 1962 MANDATORY-GROUPS { 1963 cc6kxbarModuleStatusGroupVer1, 1964 cc6kxbarChannelStatusGroup, 1965 cc6kxbarChannelStatisticsGroupVer1 1966 } 1967 1968 GROUP cc6kxbarFallbackGroup 1969 DESCRIPTION 1970 "This group is mandatory only for those platforms which 1971 support fallback mode feature." 1972 1973 GROUP cc6kxbarBusOnlyAllowedGroup 1974 DESCRIPTION 1975 "This group is mandatory only for those platforms which 1976 support bus only mode feature." 1977 1978 GROUP cc6kxbarLcdBannerGroup 1979 DESCRIPTION 1980 "This group is mandatory only for those platforms which 1981 support lcd banner feature." 1982 1983 GROUP cc6kxbarChannelUtilGroup 1984 DESCRIPTION 1985 "This group is mandatory only for those platforms which 1986 support Input and Output traffic utilization on the 1987 fabric channel." 1988 1989 GROUP cc6kxbarChannelSpeedGroup 1990 DESCRIPTION 1991 "This group is mandatory only for those platforms which 1992 support fabric channel speed feature." 1993 1994 GROUP cc6kxbarSwBusGroup 1995 DESCRIPTION 1996 "This group is mandatory only for platforms which support 1997 switching bus switching detection feature." 1998 1999 GROUP cc6kxbarSwBusNotifGroup 2000 DESCRIPTION 2001 "This group is mandatory only for platforms which support 2002 switching bus switching detection notification 2003 feature." 2004 2005 GROUP cc6kxbarTruncatedOperGroup 2006 DESCRIPTION 2007 "This group is mandatory only for platforms which support 2008 operational truncated mode." 2009 2010 GROUP cc6kxbarIntBusNotifControlGroup 2011 DESCRIPTION 2012 "This group is mandatory only for platforms which support 2013 internal bus notifications." 2014 2015 GROUP cc6kxbarIntBusCRCErrNotifGroup 2016 DESCRIPTION 2017 "This group is mandatory only for platforms which support 2018 internal bus CRC error notifications." 2019 2020 GROUP cc6kxbarIntBusCRCErrGroup 2021 DESCRIPTION 2022 "This group is mandatory only for platforms which support 2023 internal bus CRC error status." 2024 2025 GROUP cc6kxbarDcefOnlyModeAllowedGroup 2026 DESCRIPTION 2027 "This group is mandatory only for platforms which support 2028 dcef only mode feature." 2029 2030 GROUP cc6kxbarForceBusModeGroup 2031 DESCRIPTION 2032 "This group is mandatory only for platforms which support 2033 force bus mode feature." 2034 2035 GROUP cc6kxbarFlowCtrlNotifCtrlGroup 2036 DESCRIPTION 2037 "This group is mandatory only for platforms which support 2038 the system flow control notification control." 2039 2040 GROUP cc6kxbarFlowCtrlBusThreshGroup 2041 DESCRIPTION 2042 "This group is mandatory only for platforms which support 2043 the system bus flow control FIFO threshold configuration." 2044 2045 GROUP cc6kxbarFlowCtrlBusThrNotifGroup 2046 DESCRIPTION 2047 "This group is mandatory only for platforms which support 2048 the system bus flow control FIFO threshold exceeding 2049 notification." 2050 2051 GROUP cc6kxbarBusOnlyModeOperGroup 2052 DESCRIPTION 2053 "This group is mandatory only for platforms which support 2054 operational bus mode." 2055 ::= { cc6kxbarMIBCompliances 7 } 2056 2057cc6kxbarMIBComplianceVer6 MODULE-COMPLIANCE 2058 STATUS deprecated 2059 DESCRIPTION 2060 "The compliance statement for 2061 the CISCO-CAT6K-CROSSBAR-MIB." 2062 MODULE -- this module 2063 MANDATORY-GROUPS { 2064 cc6kxbarModuleStatusGroupVer1, 2065 cc6kxbarChannelStatusGroup, 2066 cc6kxbarChannelStatisticsGroupVer1 2067 } 2068 2069 GROUP cc6kxbarFallbackGroup 2070 DESCRIPTION 2071 "This group is mandatory only for those platforms which 2072 support fallback mode feature." 2073 2074 GROUP cc6kxbarBusOnlyAllowedGroup 2075 DESCRIPTION 2076 "This group is mandatory only for those platforms which 2077 support bus only mode feature." 2078 2079 GROUP cc6kxbarLcdBannerGroup 2080 DESCRIPTION 2081 "This group is mandatory only for those platforms which 2082 support lcd banner feature." 2083 2084 GROUP cc6kxbarChannelUtilGroup 2085 DESCRIPTION 2086 "This group is mandatory only for those platforms which 2087 support Input and Output traffic utilization on the 2088 fabric channel." 2089 2090 GROUP cc6kxbarChannelSpeedGroup 2091 DESCRIPTION 2092 "This group is mandatory only for those platforms which 2093 support fabric channel speed feature." 2094 2095 GROUP cc6kxbarSwBusGroup 2096 DESCRIPTION 2097 "This group is mandatory only for platforms which support 2098 switching bus switching detection feature." 2099 2100 GROUP cc6kxbarSwBusNotifGroup 2101 DESCRIPTION 2102 "This group is mandatory only for platforms which support 2103 switching bus switching detection notification 2104 feature." 2105 2106 GROUP cc6kxbarTruncatedOperGroup 2107 DESCRIPTION 2108 "This group is mandatory only for platforms which support 2109 operational truncated mode." 2110 2111 GROUP cc6kxbarIntBusNotifControlGroup 2112 DESCRIPTION 2113 "This group is mandatory only for platforms which support 2114 internal bus notifications." 2115 2116 GROUP cc6kxbarIntBusCRCErrNotifGroup 2117 DESCRIPTION 2118 "This group is mandatory only for platforms which support 2119 internal bus CRC error notifications." 2120 2121 GROUP cc6kxbarIntBusCRCErrGroup 2122 DESCRIPTION 2123 "This group is mandatory only for platforms which support 2124 internal bus CRC error status." 2125 2126 GROUP cc6kxbarDcefOnlyModeAllowedGroup 2127 DESCRIPTION 2128 "This group is mandatory only for platforms which support 2129 dcef only mode feature." 2130 2131 GROUP cc6kxbarForceBusModeGroup 2132 DESCRIPTION 2133 "This group is mandatory only for platforms which support 2134 force bus mode feature." 2135 2136 GROUP cc6kxbarFlowCtrlNotifCtrlGroup 2137 DESCRIPTION 2138 "This group is mandatory only for platforms which support 2139 the system flow control notification control." 2140 2141 GROUP cc6kxbarFlowCtrlBusThreshGroup 2142 DESCRIPTION 2143 "This group is mandatory only for platforms which support 2144 the system bus flow control FIFO threshold configuration." 2145 2146 GROUP cc6kxbarFlowCtrlBusThrNotifGroup 2147 DESCRIPTION 2148 "This group is mandatory only for platforms which support 2149 the system bus flow control FIFO threshold exceeding 2150 notification." 2151 2152 GROUP cc6kxbarBusOnlyModeOperGroup 2153 DESCRIPTION 2154 "This group is mandatory only for platforms which support 2155 operational bus mode." 2156 2157 GROUP cc6kxbarSysCapPfcOperModeGroup 2158 DESCRIPTION 2159 "This group is mandatory only for platforms which 2160 support the system information of PFC operational mode." 2161 2162 GROUP cc6kxbarSysCapSwitchResGroup 2163 DESCRIPTION 2164 "This group is mandatory only for platforms which 2165 support the capacity information of switching 2166 resources in the system." 2167 2168 GROUP cc6kxbarChannelUtilGroup1 2169 DESCRIPTION 2170 "This group is mandatory only for those platforms which 2171 support peak input and output traffic utilization on the 2172 fabric channel." 2173 2174 GROUP cc6kxbarSwBusGroup1 2175 DESCRIPTION 2176 "This group is mandatory only for platforms which support 2177 switching bus utilization." 2178 2179 GROUP cc6kxbarErrorGroup 2180 DESCRIPTION 2181 "This group is mandatory only for those platforms which 2182 support error statistics on the fabric channel." 2183 2184 GROUP cc6kxbarErrRcvryThresholdGroup 2185 DESCRIPTION 2186 "This group is mandatory for platforms which provide 2187 the configuration of thresholds on fabric link errors 2188 for the fabric error recovery feature." 2189 2190 GROUP cc6kxbarErrRcvrySwitchoverGroup 2191 DESCRIPTION 2192 "This group is mandatory for platforms which provide 2193 the configuration of fabric switchover on excessive fabric 2194 link errors for the fabric error recovery feature." 2195 ::= { cc6kxbarMIBCompliances 8 } 2196 2197cc6kxbarMIBComplianceVer7 MODULE-COMPLIANCE 2198 STATUS deprecated 2199 DESCRIPTION 2200 "The compliance statement for 2201 the CISCO-CAT6K-CROSSBAR-MIB." 2202 MODULE -- this module 2203 MANDATORY-GROUPS { 2204 cc6kxbarModuleStatusGroupVer1, 2205 cc6kxbarChannelStatusGroup, 2206 cc6kxbarChannelStatisticsGroupVer1 2207 } 2208 2209 GROUP cc6kxbarFallbackGroup 2210 DESCRIPTION 2211 "This group is mandatory only for those platforms which 2212 support fallback mode feature." 2213 2214 GROUP cc6kxbarBusOnlyAllowedGroup 2215 DESCRIPTION 2216 "This group is mandatory only for those platforms which 2217 support bus only mode feature." 2218 2219 GROUP cc6kxbarLcdBannerGroup 2220 DESCRIPTION 2221 "This group is mandatory only for those platforms which 2222 support lcd banner feature." 2223 2224 GROUP cc6kxbarChannelUtilGroup 2225 DESCRIPTION 2226 "This group is mandatory only for those platforms which 2227 support Input and Output traffic utilization on the 2228 fabric channel." 2229 2230 GROUP cc6kxbarChannelSpeedGroup 2231 DESCRIPTION 2232 "This group is mandatory only for those platforms which 2233 support fabric channel speed feature." 2234 2235 GROUP cc6kxbarSwBusGroup 2236 DESCRIPTION 2237 "This group is mandatory only for platforms which support 2238 switching bus switching detection feature." 2239 2240 GROUP cc6kxbarSwBusNotifGroup 2241 DESCRIPTION 2242 "This group is mandatory only for platforms which support 2243 switching bus switching detection notification 2244 feature." 2245 2246 GROUP cc6kxbarTruncatedOperGroup 2247 DESCRIPTION 2248 "This group is mandatory only for platforms which support 2249 operational truncated mode." 2250 2251 GROUP cc6kxbarIntBusNotifControlGroup 2252 DESCRIPTION 2253 "This group is mandatory only for platforms which support 2254 internal bus notifications." 2255 2256 GROUP cc6kxbarIntBusCRCErrNotifGroup 2257 DESCRIPTION 2258 "This group is mandatory only for platforms which support 2259 internal bus CRC error notifications." 2260 2261 GROUP cc6kxbarIntBusCRCErrGroup 2262 DESCRIPTION 2263 "This group is mandatory only for platforms which support 2264 internal bus CRC error status." 2265 2266 GROUP cc6kxbarDcefOnlyModeAllowedGroup 2267 DESCRIPTION 2268 "This group is mandatory only for platforms which support 2269 dcef only mode feature." 2270 2271 GROUP cc6kxbarForceBusModeGroup 2272 DESCRIPTION 2273 "This group is mandatory only for platforms which support 2274 force bus mode feature." 2275 2276 GROUP cc6kxbarFlowCtrlNotifCtrlGroup 2277 DESCRIPTION 2278 "This group is mandatory only for platforms which support 2279 the system flow control notification control." 2280 2281 GROUP cc6kxbarFlowCtrlBusThreshGroup 2282 DESCRIPTION 2283 "This group is mandatory only for platforms which support 2284 the system bus flow control FIFO threshold configuration." 2285 2286 GROUP cc6kxbarFlowCtrlBusThrNotifGroup 2287 DESCRIPTION 2288 "This group is mandatory only for platforms which support 2289 the system bus flow control FIFO threshold exceeding 2290 notification." 2291 2292 GROUP cc6kxbarBusOnlyModeOperGroup 2293 DESCRIPTION 2294 "This group is mandatory only for platforms which support 2295 operational bus mode." 2296 2297 GROUP cc6kxbarSysCapPfcOperModeGroup 2298 DESCRIPTION 2299 "This group is mandatory only for platforms which 2300 support the system information of PFC operational mode." 2301 2302 GROUP cc6kxbarSysCapSwitchResGroup 2303 DESCRIPTION 2304 "This group is mandatory only for platforms which 2305 support the capacity information of switching 2306 resources in the system." 2307 2308 GROUP cc6kxbarChannelUtilGroup1 2309 DESCRIPTION 2310 "This group is mandatory only for those platforms which 2311 support peak input and output traffic utilization on the 2312 fabric channel." 2313 2314 GROUP cc6kxbarSwBusGroup1 2315 DESCRIPTION 2316 "This group is mandatory only for platforms which support 2317 switching bus utilization." 2318 2319 GROUP cc6kxbarErrorGroup 2320 DESCRIPTION 2321 "This group is mandatory only for those platforms which 2322 support error statistics on the fabric channel." 2323 2324 GROUP cc6kxbarErrRcvryThresholdGroup 2325 DESCRIPTION 2326 "This group is mandatory for platforms which provide 2327 the configuration of thresholds on fabric link errors 2328 for the fabric error recovery feature." 2329 2330 GROUP cc6kxbarErrRcvrySwitchoverGroup 2331 DESCRIPTION 2332 "This group is mandatory for platforms which provide 2333 the configuration of fabric switchover on excessive fabric 2334 link errors for the fabric error recovery feature." 2335 2336 GROUP cc6kxbarErrRcvryPersLinkResGroup 2337 DESCRIPTION 2338 "This group is mandatory for platforms which provide 2339 the configuration of channel resync on excessive 2340 persistent fabric link errors for the fabric error 2341 recovery feature." 2342 2343 GROUP cc6kxbarErrRcvryChResyncGroup 2344 DESCRIPTION 2345 "This group is mandatory for platforms which provide 2346 the configuration of channel resync threshold for the 2347 fabric error recovery feature." 2348 2349 GROUP cc6kxbarTMSwBusUtilGroup 2350 DESCRIPTION 2351 "This group is mandatory for platforms which provide 2352 the configuration for traffic monitor feature on the 2353 switching bus." 2354 2355 GROUP cc6kxbarTMSwBusUtilNotifControlGroup 2356 DESCRIPTION 2357 "This group is mandatory for platforms which provide 2358 the notification control for traffic monitor 2359 notifications on the switching bus." 2360 2361 GROUP cc6kxbarTMSwBusUtilNotifObjectGroup 2362 DESCRIPTION 2363 "This group is mandatory for platforms which support 2364 traffic monitor notifications on the switching bus." 2365 2366 GROUP cc6kxbarTMSwBusUtilNotifGroup 2367 DESCRIPTION 2368 "This group is mandatory for platforms which support 2369 traffic monitor notifications on the switching bus." 2370 2371 GROUP cc6kxbarTMChUtilGroup 2372 DESCRIPTION 2373 "This group is mandatory for platforms which provide 2374 the configuration for traffic monitor feature on 2375 fabric channels." 2376 2377 GROUP cc6kxbarTMChUtilNotifControlGroup 2378 DESCRIPTION 2379 "This group is mandatory for platforms which provide 2380 the notification control for traffic monitor 2381 notifications on fabric channels." 2382 2383 GROUP cc6kxbarTMChUtilNotifObjectGroup 2384 DESCRIPTION 2385 "This group is mandatory for platforms which support 2386 traffic monitor notifications on fabric channels." 2387 2388 GROUP cc6kxbarTMChUtilNotifGroup 2389 DESCRIPTION 2390 "This group is mandatory for platforms which support 2391 traffic monitor notifications on fabric channels." 2392 ::= { cc6kxbarMIBCompliances 9 } 2393 2394cc6kxbarMIBComplianceVer8 MODULE-COMPLIANCE 2395 STATUS current 2396 DESCRIPTION 2397 "The compliance statement for 2398 the CISCO-CAT6K-CROSSBAR-MIB." 2399 MODULE -- this module 2400 MANDATORY-GROUPS { 2401 cc6kxbarModuleStatusGroupVer1, 2402 cc6kxbarChannelStatusGroup, 2403 cc6kxbarChannelStatisticsGroupVer1 2404 } 2405 2406 GROUP cc6kxbarFallbackGroup 2407 DESCRIPTION 2408 "This group is mandatory only for those platforms which 2409 support fallback mode feature." 2410 2411 GROUP cc6kxbarBusOnlyAllowedGroup 2412 DESCRIPTION 2413 "This group is mandatory only for those platforms which 2414 support bus only mode feature." 2415 2416 GROUP cc6kxbarLcdBannerGroup 2417 DESCRIPTION 2418 "This group is mandatory only for those platforms which 2419 support lcd banner feature." 2420 2421 GROUP cc6kxbarChannelUtilGroup 2422 DESCRIPTION 2423 "This group is mandatory only for those platforms which 2424 support Input and Output traffic utilization on the 2425 fabric channel." 2426 2427 GROUP cc6kxbarChannelSpeedGroup 2428 DESCRIPTION 2429 "This group is mandatory only for those platforms which 2430 support fabric channel speed feature." 2431 2432 GROUP cc6kxbarSwBusGroup 2433 DESCRIPTION 2434 "This group is mandatory only for platforms which support 2435 switching bus switching detection feature." 2436 2437 GROUP cc6kxbarSwBusNotifGroup 2438 DESCRIPTION 2439 "This group is mandatory only for platforms which support 2440 switching bus switching detection notification 2441 feature." 2442 2443 GROUP cc6kxbarTruncatedOperGroup 2444 DESCRIPTION 2445 "This group is mandatory only for platforms which support 2446 operational truncated mode." 2447 2448 GROUP cc6kxbarIntBusNotifControlGroup 2449 DESCRIPTION 2450 "This group is mandatory only for platforms which support 2451 internal bus notifications." 2452 2453 GROUP cc6kxbarIntBusCRCErrNotifGroup 2454 DESCRIPTION 2455 "This group is mandatory only for platforms which support 2456 internal bus CRC error notifications." 2457 2458 GROUP cc6kxbarIntBusCRCErrGroup 2459 DESCRIPTION 2460 "This group is mandatory only for platforms which support 2461 internal bus CRC error status." 2462 2463 GROUP cc6kxbarDcefOnlyModeAllowedGroup 2464 DESCRIPTION 2465 "This group is mandatory only for platforms which support 2466 dcef only mode feature." 2467 2468 GROUP cc6kxbarForceBusModeGroup 2469 DESCRIPTION 2470 "This group is mandatory only for platforms which support 2471 force bus mode feature." 2472 2473 GROUP cc6kxbarFlowCtrlNotifCtrlGroup 2474 DESCRIPTION 2475 "This group is mandatory only for platforms which support 2476 the system flow control notification control." 2477 2478 GROUP cc6kxbarFlowCtrlBusThreshGroup 2479 DESCRIPTION 2480 "This group is mandatory only for platforms which support 2481 the system bus flow control FIFO threshold configuration." 2482 2483 GROUP cc6kxbarFlowCtrlBusThrNotifGroup 2484 DESCRIPTION 2485 "This group is mandatory only for platforms which support 2486 the system bus flow control FIFO threshold exceeding 2487 notification." 2488 2489 GROUP cc6kxbarBusOnlyModeOperGroup 2490 DESCRIPTION 2491 "This group is mandatory only for platforms which support 2492 operational bus mode." 2493 2494 GROUP cc6kxbarSysCapPfcOperModeGroup 2495 DESCRIPTION 2496 "This group is mandatory only for platforms which 2497 support the system information of PFC operational mode." 2498 2499 GROUP cc6kxbarSysCapSwitchResGroup 2500 DESCRIPTION 2501 "This group is mandatory only for platforms which 2502 support the capacity information of switching 2503 resources in the system." 2504 2505 GROUP cc6kxbarChannelUtilGroup1 2506 DESCRIPTION 2507 "This group is mandatory only for those platforms which 2508 support peak input and output traffic utilization on the 2509 fabric channel." 2510 2511 GROUP cc6kxbarSwBusGroup1 2512 DESCRIPTION 2513 "This group is mandatory only for platforms which support 2514 switching bus utilization." 2515 2516 GROUP cc6kxbarErrorGroup 2517 DESCRIPTION 2518 "This group is mandatory only for those platforms which 2519 support error statistics on the fabric channel." 2520 2521 GROUP cc6kxbarErrRcvryThresholdGroup 2522 DESCRIPTION 2523 "This group is mandatory for platforms which provide 2524 the configuration of thresholds on fabric link errors 2525 for the fabric error recovery feature." 2526 2527 GROUP cc6kxbarErrRcvrySwitchoverGroup 2528 DESCRIPTION 2529 "This group is mandatory for platforms which provide 2530 the configuration of fabric switchover on excessive fabric 2531 link errors for the fabric error recovery feature." 2532 2533 GROUP cc6kxbarErrRcvryPersLinkResGroup 2534 DESCRIPTION 2535 "This group is mandatory for platforms which provide 2536 the configuration of channel resync on excessive 2537 persistent fabric link errors for the fabric error 2538 recovery feature." 2539 2540 GROUP cc6kxbarErrRcvryChResyncGroup 2541 DESCRIPTION 2542 "This group is mandatory for platforms which provide 2543 the configuration of channel resync threshold for the 2544 fabric error recovery feature." 2545 2546 GROUP cc6kxbarTMSwBusUtilGroup 2547 DESCRIPTION 2548 "This group is mandatory for platforms which provide 2549 the configuration for traffic monitor feature on the 2550 switching bus." 2551 2552 GROUP cc6kxbarTMSwBusUtilNotifControlGroup 2553 DESCRIPTION 2554 "This group is mandatory for platforms which provide 2555 the notification control for traffic monitor 2556 notifications on the switching bus." 2557 2558 GROUP cc6kxbarTMSwBusUtilNotifObjectGroup 2559 DESCRIPTION 2560 "This group is mandatory for platforms which support 2561 traffic monitor notifications on the switching bus." 2562 2563 GROUP cc6kxbarTMSwBusUtilNotifGroup 2564 DESCRIPTION 2565 "This group is mandatory for platforms which support 2566 traffic monitor notifications on the switching bus." 2567 2568 GROUP cc6kxbarTMChUtilGroup 2569 DESCRIPTION 2570 "This group is mandatory for platforms which provide 2571 the configuration for traffic monitor feature on 2572 fabric channels." 2573 2574 GROUP cc6kxbarTMChUtilNotifControlGroup 2575 DESCRIPTION 2576 "This group is mandatory for platforms which provide 2577 the notification control for traffic monitor 2578 notifications on fabric channels." 2579 2580 GROUP cc6kxbarTMChUtilNotifObjectGroup 2581 DESCRIPTION 2582 "This group is mandatory for platforms which support 2583 traffic monitor notifications on fabric channels." 2584 2585 GROUP cc6kxbarTMChUtilNotifGroup 2586 DESCRIPTION 2587 "This group is mandatory for platforms which support 2588 traffic monitor notifications on fabric channels." 2589 2590 GROUP cc6kxbarStatisticsLbusDropGroup 2591 DESCRIPTION 2592 "This group is mandatory for platforms which support 2593 local bus packet drop statistics on fabric channels." 2594 ::= { cc6kxbarMIBCompliances 10 } 2595 2596-- Units of Conformance 2597 2598cc6kxbarModuleStatusGroup OBJECT-GROUP 2599 OBJECTS { 2600 cc6kxbarLcdBannerMaxSize, 2601 cc6kxbarLcdBannerBanner, 2602 cc6kxbarTruncatedModeAllowed, 2603 cc6kxbarMinFabricPresent, 2604 cc6kxbarFabricActiveSlot, 2605 cc6kxbarFabricBackupSlot, 2606 cc6kxbarModuleModeSwitchingMode 2607 } 2608 STATUS deprecated 2609 DESCRIPTION 2610 "A collection of objects providing 2611 configuration and operation of the crossbar 2612 switching fabric module and switching capable 2613 module. 2614 cc6kxbarModuleStatusGroup object is superseded by cc6kxbarModuleStatusGroupVer1." 2615 ::= { cc6kxbarMIBGroups 1 } 2616 2617cc6kxbarChannelStatusGroup OBJECT-GROUP 2618 OBJECTS { 2619 cc6kxbarModuleChannelModStatus, 2620 cc6kxbarModuleChannelFabStatus 2621 } 2622 STATUS current 2623 DESCRIPTION 2624 "A collection of objects providing 2625 status and configuration of the fabric channel." 2626 ::= { cc6kxbarMIBGroups 2 } 2627 2628cc6kxbarChannelStatisticsGroup OBJECT-GROUP 2629 OBJECTS { 2630 cc6kxbarStatisticsInErrors, 2631 cc6kxbarStatisticsOutErrors, 2632 cc6kxbarStatisticsOutDropped, 2633 cc6kxbarStatisticsInUtil, 2634 cc6kxbarStatisticsOutUtil 2635 } 2636 STATUS deprecated 2637 DESCRIPTION 2638 "A collection of objects providing statistics for 2639 the fabric channel. 2640 cc6kxbarChannelStatisticsGroup object is superseded by cc6kxbarChannelStatisticsGroupVer1." 2641 ::= { cc6kxbarMIBGroups 3 } 2642 2643cc6kxbarFallbackGroup OBJECT-GROUP 2644 OBJECTS { cc6kxbarFallbackMode } 2645 STATUS current 2646 DESCRIPTION 2647 "This object controls system fallback to bus-mode 2648 after loss of switching fabric module." 2649 ::= { cc6kxbarMIBGroups 4 } 2650 2651cc6kxbarBusOnlyAllowedGroup OBJECT-GROUP 2652 OBJECTS { cc6kxbarBusOnlyModeAllowed } 2653 STATUS current 2654 DESCRIPTION 2655 "This object determines the value of 2656 cc6kxbarModuleModeSwitchingMode of each module." 2657 ::= { cc6kxbarMIBGroups 5 } 2658 2659cc6kxbarModuleStatusGroupVer1 OBJECT-GROUP 2660 OBJECTS { 2661 cc6kxbarTruncatedModeAllowed, 2662 cc6kxbarMinFabricPresent, 2663 cc6kxbarFabricActiveSlot, 2664 cc6kxbarFabricBackupSlot, 2665 cc6kxbarModuleModeSwitchingMode 2666 } 2667 STATUS current 2668 DESCRIPTION 2669 "A collection of objects providing 2670 configuration and operation of the crossbar 2671 switching fabric module and switching capable 2672 module." 2673 ::= { cc6kxbarMIBGroups 6 } 2674 2675cc6kxbarChannelStatisticsGroupVer1 OBJECT-GROUP 2676 OBJECTS { 2677 cc6kxbarStatisticsInErrors, 2678 cc6kxbarStatisticsOutErrors, 2679 cc6kxbarStatisticsOutDropped 2680 } 2681 STATUS current 2682 DESCRIPTION 2683 "A collection of objects providing statistics for 2684 the fabric channel." 2685 ::= { cc6kxbarMIBGroups 7 } 2686 2687cc6kxbarLcdBannerGroup OBJECT-GROUP 2688 OBJECTS { 2689 cc6kxbarLcdBannerMaxSize, 2690 cc6kxbarLcdBannerBanner 2691 } 2692 STATUS current 2693 DESCRIPTION 2694 "A collection of objects providing configuration of 2695 the lcd Banner of the fabric module." 2696 ::= { cc6kxbarMIBGroups 8 } 2697 2698cc6kxbarChannelUtilGroup OBJECT-GROUP 2699 OBJECTS { 2700 cc6kxbarStatisticsInUtil, 2701 cc6kxbarStatisticsOutUtil 2702 } 2703 STATUS current 2704 DESCRIPTION 2705 "These object determines Input and Output Utilization of the 2706 fabric channel." 2707 ::= { cc6kxbarMIBGroups 9 } 2708 2709cc6kxbarChannelSpeedGroup OBJECT-GROUP 2710 OBJECTS { cc6kxbarModuleChannelSpeed } 2711 STATUS current 2712 DESCRIPTION 2713 "A collection of objects providing the 2714 speed of the fabric channel." 2715 ::= { cc6kxbarMIBGroups 10 } 2716 2717cc6kxbarSwBusGroup OBJECT-GROUP 2718 OBJECTS { 2719 cc6kxbarSwBusSwitchingStatus, 2720 cc6kxbarSwBusFailureDuration, 2721 cc6kxbarSwBusNotifEnable 2722 } 2723 STATUS current 2724 DESCRIPTION 2725 "A collection of objects for the switching bus switching 2726 detection feature." 2727 ::= { cc6kxbarMIBGroups 11 } 2728 2729cc6kxbarSwBusNotifGroup NOTIFICATION-GROUP 2730 NOTIFICATIONS { cc6kxbarSwBusStatusChangeNotif } 2731 STATUS current 2732 DESCRIPTION 2733 "A collection of notifications for the switching 2734 bus switching detection feature." 2735 ::= { cc6kxbarMIBGroups 12 } 2736 2737cc6kxbarTruncatedOperGroup OBJECT-GROUP 2738 OBJECTS { cc6kxbarTruncatedModeOper } 2739 STATUS current 2740 DESCRIPTION 2741 "A collection of objects providing the 2742 operational truncated mode." 2743 ::= { cc6kxbarMIBGroups 13 } 2744 2745cc6kxbarIntBusNotifControlGroup OBJECT-GROUP 2746 OBJECTS { cc6kxbarIntBusNotifEnable } 2747 STATUS current 2748 DESCRIPTION 2749 "A collection of objects to control the notification 2750 generation for internal bus." 2751 ::= { cc6kxbarMIBGroups 14 } 2752 2753cc6kxbarIntBusCRCErrNotifGroup NOTIFICATION-GROUP 2754 NOTIFICATIONS { 2755 cc6kxbarIntBusCRCErrExcdNotif, 2756 cc6kxbarIntBusCRCErrRcvrdNotif 2757 } 2758 STATUS current 2759 DESCRIPTION 2760 "A collection of notifications for the 2761 internal bus CRC error." 2762 ::= { cc6kxbarMIBGroups 15 } 2763 2764cc6kxbarIntBusCRCErrGroup OBJECT-GROUP 2765 OBJECTS { 2766 cc6kxbarIntBusCRCErrExcdStatus, 2767 cc6kxbarIntBusCRCErrExcdCount 2768 } 2769 STATUS current 2770 DESCRIPTION 2771 "A collection of objects to indicate the internal bus 2772 CRC error information on a physical entity." 2773 ::= { cc6kxbarMIBGroups 16 } 2774 2775cc6kxbarDcefOnlyModeAllowedGroup OBJECT-GROUP 2776 OBJECTS { cc6kxbarDcefOnlyModeAllowed } 2777 STATUS current 2778 DESCRIPTION 2779 "A collection of objects providing the configuration 2780 and information about the dcef only mode feature." 2781 ::= { cc6kxbarMIBGroups 17 } 2782 2783cc6kxbarForceBusModeGroup OBJECT-GROUP 2784 OBJECTS { cc6kxbarForceBusMode } 2785 STATUS current 2786 DESCRIPTION 2787 "A collection of objects providing the configuration 2788 and information about the force bus mode feature." 2789 ::= { cc6kxbarMIBGroups 18 } 2790 2791cc6kxbarFlowCtrlNotifCtrlGroup OBJECT-GROUP 2792 OBJECTS { cc6kxbarFlowCtrlNotifEnable } 2793 STATUS current 2794 DESCRIPTION 2795 "A collection of objects to control the notification 2796 generation for the system flow control feature." 2797 ::= { cc6kxbarMIBGroups 19 } 2798 2799cc6kxbarFlowCtrlBusThreshGroup OBJECT-GROUP 2800 OBJECTS { 2801 cc6kxbarFlowCtrlBusFIFOThrMode, 2802 cc6kxbarFlowCtrlBusFIFOThrValue, 2803 cc6kxbarFlowCtrlBusFIFOTransTime 2804 } 2805 STATUS current 2806 DESCRIPTION 2807 "A collection of objects providing configuration 2808 information about the system bus flow control FIFO 2809 threshold." 2810 ::= { cc6kxbarMIBGroups 20 } 2811 2812cc6kxbarFlowCtrlBusThrNotifGroup NOTIFICATION-GROUP 2813 NOTIFICATIONS { cc6kxbarFlowCtrlBusThrExcdNotif } 2814 STATUS current 2815 DESCRIPTION 2816 "A collection of notifications for the system bus 2817 flow control FIFO threshold exceeding." 2818 ::= { cc6kxbarMIBGroups 21 } 2819 2820cc6kxbarBusOnlyModeOperGroup OBJECT-GROUP 2821 OBJECTS { cc6kxbarBusOnlyModeOper } 2822 STATUS current 2823 DESCRIPTION 2824 "A collection of objects providing the 2825 operational bus mode." 2826 ::= { cc6kxbarMIBGroups 22 } 2827 2828cc6kxbarSysCapPfcOperModeGroup OBJECT-GROUP 2829 OBJECTS { cc6kxbarSysCapPfcOperMode } 2830 STATUS current 2831 DESCRIPTION 2832 "A collection of objects providing the system 2833 information of PFC operational mode." 2834 ::= { cc6kxbarMIBGroups 23 } 2835 2836cc6kxbarSysCapSwitchResGroup OBJECT-GROUP 2837 OBJECTS { 2838 cc6kxbarSysCapSwitchResSeries, 2839 cc6kxbarSysCapSwitchResCefMode 2840 } 2841 STATUS current 2842 DESCRIPTION 2843 "A collection of objects providing the capacity 2844 information of switching resources in the system." 2845 ::= { cc6kxbarMIBGroups 24 } 2846 2847cc6kxbarChannelUtilGroup1 OBJECT-GROUP 2848 OBJECTS { 2849 cc6kxbarStatisticsPeakInUtil, 2850 cc6kxbarStatisticsPeakTmInUtil, 2851 cc6kxbarStatisticsPeakOutUtil, 2852 cc6kxbarStatisticsPeakTmOutUtil 2853 } 2854 STATUS current 2855 DESCRIPTION 2856 "A collection of objects providing the information about peak 2857 input and output utilization of a specific fabric channel on 2858 a specific module." 2859 ::= { cc6kxbarMIBGroups 25 } 2860 2861cc6kxbarSwBusGroup1 OBJECT-GROUP 2862 OBJECTS { 2863 cc6kxbarSwBusUtilization, 2864 cc6kxbarSwBusPeakUtilization, 2865 cc6kxbarSwBusPeakTimeUtil 2866 } 2867 STATUS current 2868 DESCRIPTION 2869 "A collection of objects providing the information about 2870 switching bus utilization." 2871 ::= { cc6kxbarMIBGroups 26 } 2872 2873cc6kxbarErrorGroup OBJECT-GROUP 2874 OBJECTS { 2875 cc6kxbarErrorModuleCrc, 2876 cc6kxbarErrorModuleHbeat, 2877 cc6kxbarErrorModuleSync, 2878 cc6kxbarErrorModuleDDRSync, 2879 cc6kxbarErrorChannelSync, 2880 cc6kxbarErrorChannelBuffer, 2881 cc6kxbarErrorChannelTimeout 2882 } 2883 STATUS current 2884 DESCRIPTION 2885 "A collection of objects providing error statistics for 2886 a specific fabric channel on a specific module." 2887 ::= { cc6kxbarMIBGroups 27 } 2888 2889cc6kxbarErrRcvryThresholdGroup OBJECT-GROUP 2890 OBJECTS { 2891 cc6kxbarErrRcvryThreshLink, 2892 cc6kxbarErrRcvryThreshPersLink 2893 } 2894 STATUS current 2895 DESCRIPTION 2896 "A collection of objects providing the configuration 2897 of thresholds on fabric link errors for the fabric 2898 error recovery feature." 2899 ::= { cc6kxbarMIBGroups 28 } 2900 2901cc6kxbarErrRcvrySwitchoverGroup OBJECT-GROUP 2902 OBJECTS { cc6kxbarErrRcvrySwitchoverEnable } 2903 STATUS current 2904 DESCRIPTION 2905 "A collection of objects providing the configuration 2906 of fabric switchover on excessive fabric link errors 2907 for the fabric error recovery feature." 2908 ::= { cc6kxbarMIBGroups 29 } 2909 2910cc6kxbarErrRcvryPersLinkResGroup OBJECT-GROUP 2911 OBJECTS { cc6kxbarErrRcvryPersLinkResync } 2912 STATUS current 2913 DESCRIPTION 2914 "A collection of objects providing the configuration 2915 of channel resync on excessive persistent fabric link 2916 errors for the fabric error recovery feature." 2917 ::= { cc6kxbarMIBGroups 30 } 2918 2919cc6kxbarErrRcvryChResyncGroup OBJECT-GROUP 2920 OBJECTS { 2921 cc6kxbarErrRcvryChResyncCount, 2922 cc6kxbarErrRcvryChResyncInterval 2923 } 2924 STATUS current 2925 DESCRIPTION 2926 "A collection of objects providing the configuration 2927 for channel resync threshold for the fabric error 2928 recovery feature." 2929 ::= { cc6kxbarMIBGroups 31 } 2930 2931cc6kxbarTMSwBusUtilGroup OBJECT-GROUP 2932 OBJECTS { 2933 cc6kxbarTMSwBusUtilEnable, 2934 cc6kxbarTMSwBusUtilInterval, 2935 cc6kxbarTMSwBusUtilThreshold, 2936 cc6kxbarTMSwBusUtilLogCount, 2937 cc6kxbarTMSwBusUtilLastLogTime, 2938 cc6kxbarTMSwBusUtilLogInterval 2939 } 2940 STATUS current 2941 DESCRIPTION 2942 "A collection of objects providing configuration 2943 information for traffic monitor feature on 2944 the switching bus." 2945 ::= { cc6kxbarMIBGroups 32 } 2946 2947cc6kxbarTMSwBusUtilNotifControlGroup OBJECT-GROUP 2948 OBJECTS { cc6kxbarTMSwBusUtilNotifEnable } 2949 STATUS current 2950 DESCRIPTION 2951 "A collection of objects to control the traffic monitor 2952 notification generation on the switching bus." 2953 ::= { cc6kxbarMIBGroups 33 } 2954 2955cc6kxbarTMSwBusUtilNotifObjectGroup OBJECT-GROUP 2956 OBJECTS { cc6kxbarTMSwBusUtilUtilization } 2957 STATUS current 2958 DESCRIPTION 2959 "A collection of objects included in the traffic monitor 2960 notifications on the switching bus." 2961 ::= { cc6kxbarMIBGroups 34 } 2962 2963cc6kxbarTMSwBusUtilNotifGroup NOTIFICATION-GROUP 2964 NOTIFICATIONS { 2965 cc6kxbarTMSwBusUtilAboveNotif, 2966 cc6kxbarTMSwBusUtilBelowNotif 2967 } 2968 STATUS current 2969 DESCRIPTION 2970 "A collection of traffic monitor notifications on the 2971 switching bus." 2972 ::= { cc6kxbarMIBGroups 35 } 2973 2974cc6kxbarTMChUtilGroup OBJECT-GROUP 2975 OBJECTS { 2976 cc6kxbarTMChUtilEnable, 2977 cc6kxbarTMChUtilInterval, 2978 cc6kxbarTMChUtilThreshold, 2979 cc6kxbarTMChUtilLogCount, 2980 cc6kxbarTMChUtilLastLogTime, 2981 cc6kxbarTMChUtilLogInterval 2982 } 2983 STATUS current 2984 DESCRIPTION 2985 "A collection of objects providing the configuration 2986 information for traffic monitor feature on fabric 2987 channels." 2988 ::= { cc6kxbarMIBGroups 36 } 2989 2990cc6kxbarTMChUtilNotifControlGroup OBJECT-GROUP 2991 OBJECTS { cc6kxbarTMChUtilNotifEnable } 2992 STATUS current 2993 DESCRIPTION 2994 "A collection of objects to control the traffic monitor 2995 notification generation on fabric channels." 2996 ::= { cc6kxbarMIBGroups 37 } 2997 2998cc6kxbarTMChUtilNotifObjectGroup OBJECT-GROUP 2999 OBJECTS { cc6kxbarTMChUtilUtilization } 3000 STATUS current 3001 DESCRIPTION 3002 "A collection of objects included in the traffic monitor 3003 notifications on fabric channels." 3004 ::= { cc6kxbarMIBGroups 38 } 3005 3006cc6kxbarTMChUtilNotifGroup NOTIFICATION-GROUP 3007 NOTIFICATIONS { 3008 cc6kxbarTMChUtilAboveNotif, 3009 cc6kxbarTMChUtilBelowNotif 3010 } 3011 STATUS current 3012 DESCRIPTION 3013 "A collection of traffic monitor notifications on 3014 fabric channels." 3015 ::= { cc6kxbarMIBGroups 39 } 3016 3017cc6kxbarStatisticsLbusDropGroup OBJECT-GROUP 3018 OBJECTS { cc6kxbarStatisticsLbusDrops } 3019 STATUS current 3020 DESCRIPTION 3021 "A collection of objects providing information for 3022 local bus drop packets statistics." 3023 ::= { cc6kxbarMIBGroups 40 } 3024 3025END 3026 3027 3028 3029