1TIMETRA-CHASSIS-MIB DEFINITIONS ::= BEGIN
2
3IMPORTS
4        MODULE-IDENTITY, OBJECT-TYPE,
5        NOTIFICATION-TYPE, Unsigned32,
6        Integer32, Gauge32, Counter32,
7        Counter64                               FROM SNMPv2-SMI
8
9        MODULE-COMPLIANCE, OBJECT-GROUP,
10        NOTIFICATION-GROUP                      FROM SNMPv2-CONF
11
12        TEXTUAL-CONVENTION, DateAndTime,
13        RowStatus, TimeStamp, TimeInterval,
14        TruthValue, MacAddress, RowPointer,
15        DisplayString                           FROM SNMPv2-TC
16
17        SnmpAdminString                         FROM SNMP-FRAMEWORK-MIB
18
19        TmnxActionType, TmnxPortID,
20        TItemDescription, TNamedItemOrEmpty,
21        TNamedItem, TmnxOperState,
22        THsmdaPIRMRateOverride,
23        THsmdaWeightOverride,
24        TmnxAdminState, TmnxIpSecIsaOperFlags,
25        TmnxEnabledDisabled, TIngPolicerId,
26        TmnxIngPolicerStatMode,
27        THPolPIRRateOverride, THPolCIRRateOverride,
28        TmnxIngPolicerStatModeOverride,
29        TPlcrBurstSizeBytesOverride,
30        TPerPacketOffsetOvr                     FROM TIMETRA-TC-MIB
31
32        timetraSRMIBModules, tmnxSRObjs,
33        tmnxSRNotifyPrefix, tmnxSRConfs         FROM TIMETRA-GLOBAL-MIB
34        ;
35
36tmnxChassisMIBModule MODULE-IDENTITY
37        LAST-UPDATED "201102010000Z"
38        ORGANIZATION "Alcatel-Lucent"
39        CONTACT-INFO
40            "Alcatel-Lucent SROS Support
41             Web: http://support.alcatel-lucent.com "
42        DESCRIPTION
43        "This document is the SNMP MIB module to manage and provision the
44        hardware components of the Alcatel-Lucent 7x50 device.
45
46        Copyright 2003-2014 Alcatel-Lucent.  All rights reserved.
47        Reproduction of this document is authorized on the condition that
48        the foregoing copyright notice is included.
49
50        This SNMP MIB module (Specification) embodies Alcatel-Lucent's
51        proprietary intellectual property.  Alcatel-Lucent retains
52        all title and ownership in the Specification, including any
53        revisions.
54
55        Alcatel-Lucent grants all interested parties a non-exclusive
56        license to use and distribute an unmodified copy of this
57        Specification in connection with management of Alcatel-Lucent
58        products, and without fee, provided this copyright notice and
59        license appear on all copies.
60
61        This Specification is supplied 'as is', and Alcatel-Lucent
62        makes no warranty, either express or implied, as to the use,
63        operation, condition, or performance of the Specification."
64
65--
66--  Revision History
67--
68        REVISION        "1102010000Z"
69        DESCRIPTION     "Rev 9.0                01 Feb 2011 00:00
70                         9.0 release of the TIMETRA-CHASSIS-MIB."
71
72        REVISION        "0902280000Z"
73        DESCRIPTION     "Rev 7.0                28 Feb 2009 00:00
74                         7.0 release of the TIMETRA-CHASSIS-MIB."
75
76        REVISION        "0807010000Z"
77        DESCRIPTION     "Rev 6.1                01 Jul 2008 00:00
78                         6.1 release of the TIMETRA-CHASSIS-MIB."
79
80        REVISION        "0801010000Z"
81        DESCRIPTION     "Rev 6.0                01 Jan 2008 00:00
82                         6.0 release of the TIMETRA-CHASSIS-MIB."
83
84        REVISION        "0701010000Z"
85        DESCRIPTION     "Rev 5.0                01 Jan 2007 00:00
86                         5.0 release of the TIMETRA-CHASSIS-MIB."
87
88        REVISION        "0603160000Z"
89        DESCRIPTION     "Rev 4.0                16 Mar 2006 00:00
90                         4.0 release of the TIMETRA-CHASSIS-MIB."
91
92        REVISION        "0508310000Z"
93        DESCRIPTION     "Rev 3.0                31 Aug 2005 00:00
94                         3.0 release of the TIMETRA-CHASSIS-MIB."
95
96        REVISION        "0501240000Z"
97        DESCRIPTION     "Rev 2.1                24 Jan 2005 00:00
98                        2.1 release of the TIMETRA-CHASSIS-MIB."
99
100        REVISION        "0401150000Z"
101        DESCRIPTION     "Rev 2.0                15 Jan 2004 00:00
102                         2.0 release of the TIMETRA-CHASSIS-MIB."
103
104        REVISION        "0308150000Z"
105        DESCRIPTION     "Rev 1.2                15 Aug 2003 00:00
106                         1.2 release of the TIMETRA-CHASSIS-MIB."
107
108        REVISION        "0301200000Z"
109        DESCRIPTION     "Rev 1.0                20 Jan 2003 00:00
110                         Release 1.0 of the TIMETRA-HW-MIB."
111
112        REVISION        "0008140000Z"
113        DESCRIPTION     "Rev 0.1                14 Aug 2000 00:00
114                         Initial version of the TIMETRA-HW-MIB."
115
116        ::= { timetraSRMIBModules 2 }
117
118
119--  sub-tree for managed objects, and for each functional area
120tmnxHwObjs            OBJECT IDENTIFIER ::= { tmnxSRObjs 2 }
121        tmnxChassisObjs         OBJECT IDENTIFIER ::= { tmnxHwObjs 1 }
122        tmnxSlotObjs            OBJECT IDENTIFIER ::= { tmnxHwObjs 2 }
123        tmnxCardObjs            OBJECT IDENTIFIER ::= { tmnxHwObjs 3 }
124--      tmnxPortObjs            OBJECT IDENTIFIER ::= { tmnxHwObjs 4 }
125--      tmnxPppObjs             OBJECT IDENTIFIER ::= { tmnxHwObjs 5 }
126
127tmnxChassisNotificationObjects  OBJECT IDENTIFIER ::= { tmnxHwObjs 6 }
128-- tmnxPortNotificationObjects  OBJECT IDENTIFIER ::= { tmnxHwObjs 7 }
129tmnxChassisAdminObjects         OBJECT IDENTIFIER ::= { tmnxHwObjs 8 }
130-- tmnxFRObjs                   OBJECT IDENTIFIER ::= { tmnxHwObjs 9 }
131-- tmnxQosAppObjs               OBJECT IDENTIFIER ::= { tmnxHwObjs 10 }
132-- tmnxATMObjs                  OBJECT IDENTIFIER ::= { tmnxHwObjs 11 }
133
134tmnxHwNotification           OBJECT IDENTIFIER ::= { tmnxSRNotifyPrefix 2 }
135tmnxChassisNotifyPrefix      OBJECT IDENTIFIER ::= { tmnxHwNotification 1}
136tmnxChassisNotification      OBJECT IDENTIFIER ::= { tmnxChassisNotifyPrefix 0 }
137
138--  tmnxPortNotifyPrefix   OBJECT IDENTIFIER ::= { tmnxHwNotification 2 }
139--  tmnxPortNotification    OBJECT IDENTIFIER ::= { tmnxPortNotifyPrefix 0 }
140
141--  tmnxPppNotifyPrefix     OBJECT IDENTIFIER ::= { tmnxHwNotification 3 }
142--  tmnxPppNotification     OBJECT IDENTIFIER ::= { tmnxPppNotifyPrefix 0 }
143
144--  tAtmNotifyPrefix       OBJECT IDENTIFIER ::= { tmnxSrNotifyPrefix 27 }
145--  tAtmNotifications       OBJECT IDENTIFIER ::= { tAtmNotifyPrefix 0 }
146
147tmnxHwConformance           OBJECT IDENTIFIER ::= { tmnxSRConfs 2 }
148    tmnxChassisConformance      OBJECT IDENTIFIER ::= { tmnxHwConformance 1 }
149--  tmnxPortConformance         OBJECT IDENTIFIER ::= { tmnxHwConformance 2 }
150--  tmnxPppConformance          OBJECT IDENTIFIER ::= { tmnxHwConformance 3 }
151
152--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
153--
154--      TIMETRA-CHASSIS-MIB textual conventions
155--
156
157--
158--      TmnxAlarmState
159--
160TmnxAlarmState ::= TEXTUAL-CONVENTION
161    STATUS      current
162    DESCRIPTION
163        "The TmnxAlarmState is an enumerated integer whose value indicates
164         the current alarm state of a physical or logical component in the
165         Alcatel-Lucent SROS series system."
166    SYNTAX  INTEGER {
167                unknown (0),
168                alarmActive (1),
169                alarmCleared (2)
170            }
171
172--
173--      TmnxChassisIndex
174--
175TmnxChassisIndex ::= TEXTUAL-CONVENTION
176    STATUS      current
177    DESCRIPTION
178        "The TmnxChassisIndex is a unique index that identifies a chassis
179         within an Alcatel-Lucent SROS system.  Note that initial releases will
180         support only one chassis in a system."
181    SYNTAX      INTEGER (1..32)
182
183TmnxChassisIndexOrZero ::= TEXTUAL-CONVENTION
184    STATUS      current
185    DESCRIPTION
186        "The TmnxChassisIndexOrZero can be either a nonzero TmnxChassisIndex,
187         or the value zero."
188    SYNTAX      INTEGER (0..32)
189
190--
191--      TmnxHwIndex
192--
193TmnxHwIndex ::= TEXTUAL-CONVENTION
194    STATUS      current
195    DESCRIPTION
196        "The TmnxHwIndex is a unique integer index that identifies an
197         Alcatel-Lucent SROS series manufactured hardware component, such as
198         an IOM, CPM, Fabric or MDA card."
199    SYNTAX      Integer32 (1..2147483647)
200
201TmnxHwIndexOrZero ::= TEXTUAL-CONVENTION
202    STATUS      current
203    DESCRIPTION
204        "The TmnxHwIndexOrZero is a unique integer index that identifies an
205         Alcatel-Lucent SROS series manufactured hardware component, such as
206         an IOM, CPM, Fabric or MDA card. Also TmnxHwIndexOrZero can be zero."
207    SYNTAX      Integer32 (0..2147483647)
208
209--
210--      TmnxHwClass
211--
212TmnxHwClass ::= TEXTUAL-CONVENTION
213    STATUS      current
214    DESCRIPTION
215        "TmnxHwClass is an enumerated integer that identifies the general
216         hardware type of a component in the tmnxHwTable."
217    SYNTAX  INTEGER {
218                other (1),
219                unknown (2),
220                chassis (3),
221                container (4),
222                powerSupply (5),
223                fan (6),
224                sensor (7),
225                ioModule (8),
226                cpmModule (9),
227                fabricModule (10),
228                mdaModule (11),
229                flashDiskModule (12),
230                port (13),
231                mcm (14),
232                ccm (15),
233                alarmInputModule (16),
234                vwmShelfModule (30)
235            }
236
237--
238--      TmnxCardType
239--
240TmnxCardType ::= TEXTUAL-CONVENTION
241    STATUS  current
242    DESCRIPTION
243        "The TmnxCardType data type is an integer that specifies an
244         Alcatel-Lucent SROS series card type.
245
246         A TmnxCardType value is valid when there is a corresponding row in the
247         tmnxCardTypeTable."
248    SYNTAX  Unsigned32
249
250--
251--      TmnxCardSuppType
252--
253TmnxCardSuppType                 ::= TEXTUAL-CONVENTION
254    STATUS      current
255    DESCRIPTION
256        "The TmnxCardSuppType is a bit-mask specifying the valid card types
257         supported for a specific card slot.
258
259         When multiple bits are set, it can be used to identify a set or
260         list of card types used in the tmnxCardTable and tmnxCpmCardTable to
261         indicate supported cards within a specific chassis slot.
262         Some example card types might be:
263
264                    sfm-400g  -- 400g CPM/SF module
265                    sfm-200g  -- 200g CPM/SF module
266                    iom-20g   -- 2 x 10-Gig MDA IOM Card"
267   SYNTAX BITS {
268                    invalid-card-type  (0),
269                    unassigned         (1),
270                    supp-card-type-2   (2),
271                    supp-card-type-3   (3),
272                    supp-card-type-4   (4),
273                    supp-card-type-5   (5),
274                    supp-card-type-6   (6),
275                    supp-card-type-7   (7),
276                    supp-card-type-8   (8),
277                    supp-card-type-9   (9),
278                    supp-card-type-10 (10),
279                    supp-card-type-11 (11),
280                    supp-card-type-12 (12),
281                    supp-card-type-13 (13),
282                    supp-card-type-14 (14),
283                    supp-card-type-15 (15),
284                    supp-card-type-16 (16),
285                    supp-card-type-17 (17),
286                    supp-card-type-18 (18),
287                    supp-card-type-19 (19),
288                    supp-card-type-20 (20),
289                    supp-card-type-21 (21),
290                    supp-card-type-22 (22),
291                    supp-card-type-23 (23),
292                    supp-card-type-24 (24),
293                    supp-card-type-25 (25),
294                    supp-card-type-26 (26),
295                    supp-card-type-27 (27),
296                    supp-card-type-28 (28),
297                    supp-card-type-29 (29),
298                    supp-card-type-30 (30),
299                    supp-card-type-31 (31),
300                    supp-card-type-32 (32),
301                    supp-card-type-33 (33),
302                    supp-card-type-34 (34),
303                    supp-card-type-35 (35),
304                    supp-card-type-36 (36),
305                    supp-card-type-37 (37),
306                    supp-card-type-38 (38),
307                    supp-card-type-39 (39),
308                    supp-card-type-40 (40),
309                    supp-card-type-41 (41),
310                    supp-card-type-42 (42),
311                    supp-card-type-43 (43),
312                    supp-card-type-44 (44),
313                    supp-card-type-45 (45),
314                    supp-card-type-46 (46),
315                    supp-card-type-47 (47),
316                    supp-card-type-48 (48),
317                    supp-card-type-49 (49),
318                    supp-card-type-50 (50),
319                    supp-card-type-51 (51),
320                    supp-card-type-52 (52),
321                    supp-card-type-53 (53),
322                    supp-card-type-54 (54),
323                    supp-card-type-55 (55),
324                    supp-card-type-56 (56),
325                    supp-card-type-57 (57),
326                    supp-card-type-58 (58),
327                    supp-card-type-59 (59),
328                    supp-card-type-60 (60),
329                    supp-card-type-61 (61),
330                    supp-card-type-62 (62),
331                    supp-card-type-63 (63)
332   }
333
334--
335--      TmnxFabricType
336--
337TmnxFabricType                   ::= TEXTUAL-CONVENTION
338    STATUS  current
339    DESCRIPTION
340        "The TmnxFabricType data type is an integer that specifies an
341         Alcatel-Lucent SROS series fabric card type.
342
343         A TmnxFabricType value is valid when there is a corresponding row in
344         the tmnxFabricTypeTable."
345    SYNTAX  Unsigned32
346
347--
348--      TmnxFabricSuppType
349--
350TmnxFabricSuppType               ::= TEXTUAL-CONVENTION
351    STATUS      current
352    DESCRIPTION
353        "The TmnxFabricSuppType is a bit-mask specifying the valid fabric card
354         types supported for a specific card slot.
355
356         When multiple bits are set, it can be used to identify a set or
357         list of card types used in the tmnxFabricTable to indicate supported
358         fabric cards within a specific chassis slot.
359         Some example card types might be:
360
361                    integrated -- the CPM/SF Module consists of an integrated
362                                  fabric card."
363   SYNTAX BITS {
364                    invalidCardType (0),
365                    unassigned      (1),
366                    suppCardType2   (2),
367                    suppCardType3   (3),
368                    suppCardType4   (4),
369                    suppCardType5   (5),
370                    suppCardType6   (6),
371                    suppCardType7   (7),
372                    suppCardType8   (8),
373                    suppCardType9   (9),
374                    suppCardType10 (10),
375                    suppCardType11 (11),
376                    suppCardType12 (12),
377                    suppCardType13 (13),
378                    suppCardType14 (14),
379                    suppCardType15 (15),
380                    suppCardType16 (16),
381                    suppCardType17 (17),
382                    suppCardType18 (18),
383                    suppCardType19 (19),
384                    suppCardType20 (20),
385                    suppCardType21 (21),
386                    suppCardType22 (22),
387                    suppCardType23 (23),
388                    suppCardType24 (24),
389                    suppCardType25 (25),
390                    suppCardType26 (26),
391                    suppCardType27 (27),
392                    suppCardType28 (28),
393                    suppCardType29 (29),
394                    suppCardType30 (30),
395                    suppCardType31 (31),
396                    suppCardType32 (32),
397                    suppCardType33 (33),
398                    suppCardType34 (34),
399                    suppCardType35 (35),
400                    suppCardType36 (36),
401                    suppCardType37 (37),
402                    suppCardType38 (38),
403                    suppCardType39 (39),
404                    suppCardType40 (40),
405                    suppCardType41 (41),
406                    suppCardType42 (42),
407                    suppCardType43 (43),
408                    suppCardType44 (44),
409                    suppCardType45 (45),
410                    suppCardType46 (46),
411                    suppCardType47 (47),
412                    suppCardType48 (48),
413                    suppCardType49 (49),
414                    suppCardType50 (50),
415                    suppCardType51 (51),
416                    suppCardType52 (52),
417                    suppCardType53 (53),
418                    suppCardType54 (54),
419                    suppCardType55 (55),
420                    suppCardType56 (56),
421                    suppCardType57 (57),
422                    suppCardType58 (58),
423                    suppCardType59 (59),
424                    suppCardType60 (60),
425                    suppCardType61 (61),
426                    suppCardType62 (62),
427                    suppCardType63 (63)
428   }
429--
430--      TmnxCardRebootType
431--
432TmnxCardRebootType ::= TEXTUAL-CONVENTION
433    STATUS  current
434    DESCRIPTION
435        "The TmnxCardRebootType is an enumerated integer that describes the
436         values used to support reboot operation style commands.
437
438         GETs and GETNEXTs on a variable of this type always returns
439         'not-applicable (2)'."
440    SYNTAX  INTEGER {
441                cardReset      (1),
442                notApplicable  (2),
443                cardPowerCycle (3)
444            }
445
446--
447--      TmnxChassisType
448--
449TmnxChassisType ::= TEXTUAL-CONVENTION
450    STATUS  current
451    DESCRIPTION
452        "The TmnxChassisType data type is an integer that specifies
453         the index value for the entry in the tmnxChassisTypeTable used to
454         identify a specific type of chassis backplane manufactured
455         by Alcatel-Lucent."
456    SYNTAX  Unsigned32
457
458--
459--      TmnxDeviceState
460--
461TmnxDeviceState ::= TEXTUAL-CONVENTION
462    STATUS  current
463    DESCRIPTION
464        "The TmnxDeviceState data type is an enumerated integer that
465         describes the values used to identify states of chassis
466         components such as fans and power supplies."
467    SYNTAX  INTEGER {
468                deviceStateUnknown (1),
469                deviceNotEquipped (2),
470                deviceStateOk (3),
471                deviceStateFailed (4),
472                deviceStateOutOfService (5)
473            }
474
475--
476--      TmnxLEDState
477--
478TmnxLEDState ::= TEXTUAL-CONVENTION
479    STATUS  current
480    DESCRIPTION
481        "The TmnxLEDState data type is an enumerated integer that
482         describes the values used to identify state LEDs on Alcatel-Lucent
483         SROS series cards."
484    SYNTAX  INTEGER {
485                ledOff          (1),
486                ledRed          (2),
487                ledAmber        (3),
488                ledYellow       (4),
489                ledGreen        (5),
490                ledAmberBlink   (6),
491                ledYellowBlink  (7),
492                ledGreenBlink   (8)
493            }
494
495--
496--      TmnxMdaType
497--
498TmnxMdaType ::= TEXTUAL-CONVENTION
499    STATUS      current
500    DESCRIPTION
501        "The TmnxMdaType data type is an integer that used to identify the
502         kind of Media Dependent Adapter (MDA) installed on a card.
503
504         The value of TmnxMdaType corresponds to the bit number indicated by
505         TmnxMDASuppType.
506
507         A TmnxMdaType value specifies the index value for the entry in the
508         tmnxMdaTypeTable used to identify a specific type of MDA
509         manufactured by Alcatel-Lucent."
510    SYNTAX      Unsigned32
511
512--
513--      TmnxMDASuppType
514--
515TmnxMDASuppType ::= TEXTUAL-CONVENTION
516    STATUS      current
517    DESCRIPTION
518        "The TmnxMDASuppType data type is a SNMP BIT that is used to identify
519         the kind of Media Dependent Adapter (MDA) supported on a card.
520
521         When multiple bits are set, it can be used to identify a set or list
522         of supported MDAs within a specific card slot. The MDA types are
523         defined in the tmnxMdaTypeTable."
524    SYNTAX      BITS {
525                    invalid-MDA-type (0),
526                    unassigned (1),
527                    supp-MDA-type-2 (2),
528                    supp-MDA-type-3 (3),
529                    supp-MDA-type-4 (4),
530                    supp-MDA-type-5 (5),
531                    supp-MDA-type-6 (6),
532                    supp-MDA-type-7 (7),
533                    supp-MDA-type-8 (8),
534                    supp-MDA-type-9 (9),
535                    supp-MDA-type-10 (10),
536                    supp-MDA-type-11 (11),
537                    supp-MDA-type-12 (12),
538                    supp-MDA-type-13 (13),
539                    supp-MDA-type-14 (14),
540                    supp-MDA-type-15 (15),
541                    supp-MDA-type-16 (16),
542                    supp-MDA-type-17 (17),
543                    supp-MDA-type-18 (18),
544                    supp-MDA-type-19 (19),
545                    supp-MDA-type-20 (20),
546                    supp-MDA-type-21 (21),
547                    supp-MDA-type-22 (22),
548                    supp-MDA-type-23 (23),
549                    supp-MDA-type-24 (24),
550                    supp-MDA-type-25 (25),
551                    supp-MDA-type-26 (26),
552                    supp-MDA-type-27 (27),
553                    supp-MDA-type-28 (28),
554                    supp-MDA-type-29 (29),
555                    supp-MDA-type-30 (30),
556                    supp-MDA-type-31 (31),
557                    supp-MDA-type-32 (32),
558                    supp-MDA-type-33 (33),
559                    supp-MDA-type-34 (34),
560                    supp-MDA-type-35 (35),
561                    supp-MDA-type-36 (36),
562                    supp-MDA-type-37 (37),
563                    supp-MDA-type-38 (38),
564                    supp-MDA-type-39 (39),
565                    supp-MDA-type-40 (40),
566                    supp-MDA-type-41 (41),
567                    supp-MDA-type-42 (42),
568                    supp-MDA-type-43 (43),
569                    supp-MDA-type-44 (44),
570                    supp-MDA-type-45 (45),
571                    supp-MDA-type-46 (46),
572                    supp-MDA-type-47 (47),
573                    supp-MDA-type-48 (48),
574                    supp-MDA-type-49 (49),
575                    supp-MDA-type-50 (50),
576                    supp-MDA-type-51 (51),
577                    supp-MDA-type-52 (52),
578                    supp-MDA-type-53 (53),
579                    supp-MDA-type-54 (54),
580                    supp-MDA-type-55 (55),
581                    supp-MDA-type-56 (56),
582                    supp-MDA-type-57 (57),
583                    supp-MDA-type-58 (58),
584                    supp-MDA-type-59 (59),
585                    supp-MDA-type-60 (60),
586                    supp-MDA-type-61 (61),
587                    supp-MDA-type-62 (62),
588                    supp-MDA-type-63 (63),
589                    supp-MDA-type-64 (64),
590                    supp-MDA-type-65 (65),
591                    supp-MDA-type-66 (66),
592                    supp-MDA-type-67 (67),
593                    supp-MDA-type-68 (68),
594                    supp-MDA-type-69 (69),
595                    supp-MDA-type-70 (70),
596                    supp-MDA-type-71 (71),
597                    supp-MDA-type-72 (72),
598                    supp-MDA-type-73 (73),
599                    supp-MDA-type-74 (74),
600                    supp-MDA-type-75 (75),
601                    supp-MDA-type-76 (76),
602                    supp-MDA-type-77 (77),
603                    supp-MDA-type-78 (78),
604                    supp-MDA-type-79 (79),
605                    supp-MDA-type-80 (80),
606                    supp-MDA-type-81 (81),
607                    supp-MDA-type-82 (82),
608                    supp-MDA-type-83 (83),
609                    supp-MDA-type-84 (84),
610                    supp-MDA-type-85 (85),
611                    supp-MDA-type-86 (86),
612                    supp-MDA-type-87 (87),
613                    supp-MDA-type-88 (88),
614                    supp-MDA-type-89 (89),
615                    supp-MDA-type-90 (90),
616                    supp-MDA-type-91 (91),
617                    supp-MDA-type-92 (92),
618                    supp-MDA-type-93 (93),
619                    supp-MDA-type-94 (94),
620                    supp-MDA-type-95 (95),
621                    supp-MDA-type-96 (96),
622                    supp-MDA-type-97 (97),
623                    supp-MDA-type-98 (98),
624                    supp-MDA-type-99 (99),
625                    supp-MDA-type-100 (100),
626                    supp-MDA-type-101 (101),
627                    supp-MDA-type-102 (102),
628                    supp-MDA-type-103 (103),
629                    supp-MDA-type-104 (104),
630                    supp-MDA-type-105 (105),
631                    supp-MDA-type-106 (106),
632                    supp-MDA-type-107 (107),
633                    supp-MDA-type-108 (108),
634                    supp-MDA-type-109 (109),
635                    supp-MDA-type-110 (110),
636                    supp-MDA-type-111 (111)
637                }
638--
639--      TmnxMDAChanType
640--
641TmnxMDAChanType ::= TEXTUAL-CONVENTION
642    STATUS      current
643    DESCRIPTION
644        "The TmnxMDAChanType data type indicates the type of channel that
645         can be created on an MDA."
646    SYNTAX  INTEGER {
647                unknown (0),
648                sonetSts768(1),
649                sonetSts192(2),
650                sonetSts48(3),
651                sonetSts12(4),
652                sonetSts3(5),
653                sonetSts1(6),
654                sdhTug3(7),
655                sonetVtg(8),
656                sonetVt15(9),
657                sonetVt2(10),
658                sonetVt3(11),
659                sonetVt6(12),
660                pdhTu3(13),
661                pdhDs3(14),
662                pdhE3(15),
663                pdhDs1(16),
664                pdhE1(17),
665                pdhDs0Grp(18)
666            }
667
668TmnxMdaAtmMode ::= TEXTUAL-CONVENTION
669    STATUS      current
670    DESCRIPTION
671        "TmnxMdaAtmMode is an enumerated integer whose value specifies
672         the maximum number of Virtual Circuits
673         for an ATM-capable Media Dependent Adapter (MDA)."
674    SYNTAX  INTEGER {
675                notApplicable (0),
676                max8kVc       (1),
677                max16kVc      (2)
678            }
679
680--
681--      TmnxCcmType
682--
683TmnxCcmType ::= TEXTUAL-CONVENTION
684    STATUS      current
685    DESCRIPTION
686        "The TmnxCcmType data type is bit-mask field that describes
687         the values used to identify the kind of Chassis Control
688         module (CCM) installed on the chassis.  A TmnxCcmType bit
689         value specifies the index value for the entry in the
690         tmnxCcmTypeTable used to identify a specific type of CCM
691         manufactured by Alcatel-Lucent.  When multiple bits are set, it can
692         be used to identify a set or list of CCM types used in the
693         tmnxCcmTable to indicate supported CCMs within a specific
694         chassis slot.  Some example CCM types are:
695
696                    unknown            -- unknown/uninstalled
697                    ccm-v1             -- Chassis Control Module version 1
698
699        "
700    SYNTAX      Unsigned32
701
702--
703--      TmnxMcmType
704--
705TmnxMcmType ::= TEXTUAL-CONVENTION
706    STATUS      current
707    DESCRIPTION
708        "The TmnxMcmType data type is bit-mask field that describes
709         the values used to identify the kind of MDA Carrier
710         module (MCM) installed on the chassis.  A TmnxMcmType bit
711         value specifies the index value for the entry in the
712         tmnxMcmTypeTable used to identify a specific type of MCM
713         manufactured by Alcatel-Lucent.  When multiple bits are set, it can
714         be used to identify a set or list of MCM types used in the
715         tmnxMcmTable to indicate supported MCMs within a specific
716         card slot."
717    SYNTAX      Unsigned32
718
719--
720--      TmnxSlotNum
721--
722TmnxSlotNum ::= TEXTUAL-CONVENTION
723    STATUS  current
724    DESCRIPTION
725        "The TmnxSlotNum data type is an integer that specifies a slot in
726         an Alcatel-Lucent SROS series chassis."
727    SYNTAX  INTEGER (1..128)
728
729TmnxSlotNumOrZero ::= TEXTUAL-CONVENTION
730    STATUS  current
731    DESCRIPTION
732        "The TmnxSlotNumOrZero data type is an integer that specifies a
733         slot in an Alcatel-Lucent SROS series chassis or zero."
734    SYNTAX  INTEGER (0..128)
735
736--
737--      TmnxPortAdminStatus
738--
739TmnxPortAdminStatus ::= TEXTUAL-CONVENTION
740    STATUS      current
741    DESCRIPTION
742        "The desired administrative status of this port."
743    SYNTAX      INTEGER {
744                    noop (1),
745                    inService (2),
746                    outOfService (3),
747                    diagnose (4)
748                }
749
750--
751--      TmnxChassisMode
752--
753TmnxChassisMode ::= TEXTUAL-CONVENTION
754    STATUS  current
755    DESCRIPTION
756        "The TmnxChassisMode data type is an enumerated integer that specifies
757         the values used to identify which set of scaling numbers and features
758         are effective for an Alcatel-Lucent SROS series chassis.
759         'modeA' corresponds to the scaling and feature set on the existing
760         iom-20g. 'modeB' corresponds to the scaling and features that come
761         with iom-20g-b. 'modeC' corresponds to the scaling and features that
762         come with iom2-20g. 'modeD' corresponds to the scaling and features
763         that come with iom3-xp/imm modules."
764    SYNTAX  INTEGER {
765                modeA   (1),
766                modeB   (2),
767                modeC   (3),
768                modeD   (4)
769            }
770
771--
772--      TmnxSETSRefSource
773--
774TmnxSETSRefSource ::= TEXTUAL-CONVENTION
775    STATUS  current
776    DESCRIPTION
777        "The TmnxSETSRefSource data type is an enumerated integer that
778         describes the values used to identify the Synchronous Equipment
779         Timing Subsystem (SETS) timing reference source."
780    SYNTAX  INTEGER {
781                otherCPM    (0),
782                reference1  (1),
783                reference2  (2),
784                bits1       (3),
785                bits2       (4),
786                ptp         (5),
787                noReference (6)
788            }
789
790--
791--      TmnxSETSRefQualified
792--
793TmnxSETSRefQualified ::= TEXTUAL-CONVENTION
794    STATUS  current
795    DESCRIPTION
796        "The TmnxSETSRefQualified data type is an enumerated integer that
797         describes the values used to identify whether the reference is
798         'qualified' or 'not-qualified' for use by SETS."
799    SYNTAX  INTEGER {
800                qualified (1),
801                not-qualified (2)
802            }
803
804--
805--      TmnxSETSRefAlarm
806--
807TmnxSETSRefAlarm ::= TEXTUAL-CONVENTION
808    STATUS  current
809    DESCRIPTION
810        "The TmnxSETSRefAlarm data type is a bitmap that describes the values
811         used to identify the alarms on the SETS timing reference source if
812         the source is 'not-qualified'.
813
814         'los'    - loss of signal
815         'oof'    - out of frequency range
816         'oopir'  - out of pull in range."
817    SYNTAX  BITS {
818                los (0),
819                oof (1),
820                oopir (2)
821            }
822
823--
824--      TmnxBITSIfType
825--
826TmnxBITSIfType ::= TEXTUAL-CONVENTION
827    STATUS  current
828    DESCRIPTION
829        "The TmnxBITSIfType data type is an enumerated integer that describes
830         the values used to identify the interface and framing types of a BITS
831         (Building Integrated Timing Supply) interface."
832    SYNTAX  INTEGER {
833                    none (0),
834                    t1-esf (1),
835                    t1-sf (2),
836                    e1-pcm30crc (3),
837                    e1-pcm31crc (4)
838            }
839
840--
841--      TmnxSSMQualityLevel
842--
843TmnxSSMQualityLevel              ::= TEXTUAL-CONVENTION
844    STATUS      current
845    DESCRIPTION
846        "The TmnxSSMQualityLevel is an enumerated integer that
847         describes the values used to identify the SSM Quality level of received
848         SSM messages."
849    SYNTAX      INTEGER {
850                    unknown (0),
851                    prs     (1),
852                    stu     (2),
853                    st2     (3),
854                    tnc     (4),
855                    st3e    (5),
856                    st3     (6),
857                    smc     (7),
858                    st4     (8),
859                    dus     (9),
860                    prc     (10),
861                    ssua    (11),
862                    ssub    (12),
863                    sec     (13),
864                    dnu     (14),
865                    inv     (15),
866                    pno     (16),
867                    eec1    (17),
868                    eec2    (18),
869                    failed  (19)
870                }
871
872--
873--      TmnxRefInState
874--
875TmnxRefInState                   ::= TEXTUAL-CONVENTION
876    STATUS      current
877    DESCRIPTION
878        "The TmnxRefInState is an enumerated integer that describes the values
879         used to identify the state of system timing reference.
880
881         A value of 'ptpAdminDisabled (17)' means that the PTP timing reference
882         is not in use because 'tmnxPtpClockAdminState' is 'outOfService (3)'.
883         This value only applies to the PTP timing reference.
884
885         A value of 'ptpOperDown (18)' means that the PTP timing reference is
886         not in use because 'tmnxPtpClockOperState' is 'outOfService (3)'.
887         This value only applies to the PTP timing reference.
888
889         A value of 'ptpNoParentClock (19)' means that the PTP timing reference
890         is not in use because the local PTP clock has not selected a remote
891         master clock to be the parent clock.  This value only applies to the
892         PTP timing reference."
893    REFERENCE
894        "IEEE Std 1588-2008 'IEEE Standard for a Precision Clock Synchronization
895         Protocol for Networked Measurement and Control Systems'"
896    SYNTAX      INTEGER {
897                    disabled         (0),
898                    unqualified      (1),
899                    standby          (2),
900                    up               (3),
901                    previousFailure  (4),
902                    lowQuality       (5),
903                    lof              (6),
904                    ais              (7),
905                    ghost            (8),
906                    validating       (9),
907                    reserved-10      (10),
908                    reserved-11      (11),
909                    reserved-12      (12),
910                    fer              (13),
911                    reserved-14      (14),
912                    reserved-15      (15),
913                    reserved-16      (16),
914                    ptpAdminDisabled (17),
915                    ptpOperDown      (18),
916                    ptpNoParentClock (19)
917                }
918
919--
920--      TmnxBITSOutSource
921--
922TmnxBITSOutSource                ::= TEXTUAL-CONVENTION
923    STATUS      current
924    DESCRIPTION
925        "The TmnxBITSOutSource is an enumerated integer that describes the
926         values used to identity the source of the BITS (Building Integrated
927         Timing Supply) output.
928
929         When TmnxBITSOutSource is 'lineRef (1)', the BITS output timing is
930         selected from either the first or second line reference input's timing,
931         without any filtering.
932
933         When TmnxBITSOutSource is 'internalClock (2)', the BITS output timing
934         is driven from the system timing."
935    REFERENCE
936        "ITU-T G.8264/Y.1364 Distribution of timing through packet networks,
937         Section A.7."
938    SYNTAX      INTEGER {
939                    lineRef         (1),
940                    internalClock   (2)
941                }
942
943--
944--      TmnxCcagId
945--
946TmnxCcagId ::= TEXTUAL-CONVENTION
947    STATUS               current
948    DESCRIPTION
949        "TmnxCcagId is an integer specifying the cross connect aggregation
950         group. The value '0' is used when a ccag is not defined and is not
951         a valid value when TmnxCcagId is used as an index."
952    SYNTAX Integer32 (0|1..8)
953
954--
955--      TmnxCcagRate
956--
957TmnxCcagRate ::= TEXTUAL-CONVENTION
958    STATUS              current
959    DESCRIPTION
960        "TmnxCcagRate is an integer specifying the rate for a CCAG member in
961         Kbps.  The range of TmnxCcagRate is from 0 Kbps to 100Gbps. The value
962         '-1' is used for maximum rate available."
963    SYNTAX  Integer32 (-1|0..100000000)
964
965--
966--      TmnxCcagRateOption
967--
968TmnxCcagRateOption ::= TEXTUAL-CONVENTION
969    STATUS              current
970    DESCRIPTION
971        "TmnxCcagRateOption specifies how the defined rate is
972         applied to active Cross Connect Adaptors (CCAs).
973         aggregate (1) -  the defined rate is equally divided among the CCAs in
974                          the CCAG member list based on the number of active
975                          CCAs.
976         cca       (2) -  the defined rate is applied to all CCAs in the CCAG
977                          member list."
978    SYNTAX  INTEGER {
979                aggregate (1),
980                cca       (2)
981            }
982--
983--      TmnxChassisPemType
984--
985TmnxChassisPemType ::= TEXTUAL-CONVENTION
986    STATUS              current
987    DESCRIPTION
988        "TmnxChassisPemType specifies what Power Entry Module (PEM) type is
989         installed in the Chassis.
990         not-applicable (0) - Chassis does not support an installed PEM.
991         unknown (1)        - Unknown kind of PEM installed./
992         pem (2)            - First generation of the PEM module.
993         pem-3 (3)          - Second generation of the PEM module capable of
994                              supporting the IOM3/IMM modules.
995         peq (4)            - Power Equalizer."
996    SYNTAX  INTEGER {
997                not-applicable (0),
998                unknown        (1),
999                pem            (2),
1000                pem-3          (3),
1001                peq            (4)
1002            }
1003
1004TmnxCardSlotBitMap               ::= TEXTUAL-CONVENTION
1005    STATUS      current
1006    DESCRIPTION
1007        "TmnxCardSlotBitMap specifies a bitmap of card slots. A bit value set to
1008         '1' indicates the slot is used by the object."
1009    SYNTAX      BITS {
1010                   slot1   (0),
1011                   slot2   (1),
1012                   slot3   (2),
1013                   slot4   (3),
1014                   slot5   (4),
1015                   slot6   (5),
1016                   slot7   (6),
1017                   slot8   (7),
1018                   slot9   (8),
1019                   slot10  (9),
1020                   slot11  (10),
1021                   slot12  (11),
1022                   slot13  (12),
1023                   slot14  (13),
1024                   slot15  (14),
1025                   slot16  (15)
1026                }
1027
1028--
1029--      TmnxTunnelGroupId
1030--
1031TmnxTunnelGroupId ::= TEXTUAL-CONVENTION
1032    STATUS               current
1033    DESCRIPTION
1034        "TmnxTunnelGroupId is an integer specifying the ISA tunnel-group."
1035    SYNTAX Unsigned32 (1..16)
1036
1037TmnxTunnelGroupIdOrZero ::= TEXTUAL-CONVENTION
1038    STATUS               current
1039    DESCRIPTION
1040        "TmnxTunnelGroupIdOrZero is an integer specifying the ISA tunnel-group
1041         A value of zero is used when the tunnel-group is not defined."
1042    SYNTAX Unsigned32 (0|1..16)
1043
1044--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
1045--
1046--      TIMETRA-CHASSIS-MIB at a glance
1047--
1048--  timetra (enterprises 6527)
1049--    timetraProducts (3)
1050--      tmnxSRMIB (1)
1051--                tmnxSRConfs (1)
1052--                tmnxSRObjs (2)
1053--                      tmnxHwObjs (tmnxSRObjs 2)
1054--                tmnxSRNotifyPrefix (3)
1055--
1056--
1057--  tmnxChassisObjs (tmnxHwObjs 1)
1058--        tmnxChassisTotalNumber (1)
1059--        tmnxChassisLastChange (2)
1060--        tmnxChassisTable (3)
1061--        tmnxChassisFanTable (4)
1062--        tmnxChassisPowerSupplyTable (5)
1063--        tmnxChassisTypeTable (6)
1064--        tmnxChassisHwLastChange (7)
1065--        tmnxHwTable (8)
1066--        tmnxHwContainsTable (9)
1067--        tmnxCcmTable (10)
1068--        tmnxCcmTypeTable (11)
1069--
1070--  tmnxSlotObjs (2)    - not used
1071--
1072--  tmnxCardObjs (3)
1073--        tmnxCardLastChange (1)
1074--        tmnxCardTable (2)
1075--        tmnxCpmCardLastChange (3)
1076--        tmnxCpmCardTable (4)
1077--        tmnxFabricLastChange (5)
1078--        tmnxFabricTable (6)
1079--        tmnxCpmFlashTable (7)
1080--        tmnxMDATable (8)
1081--        tmnxCardTypeTable (9)
1082--        tmnxMdaTypeTable (10)
1083--        tmnxSyncIfTimingTable (11)
1084--        tmnxCcagTable (12)
1085--        tmnxCcagPathTable (13)
1086--        tmnxCcagPathCcTable (14)
1087--        tmnxMcmTable (15)
1088--        tmnxMcmTypeTable (16)
1089--        tmnxIPsecIsaGrpTableLastChanged(17)
1090--        tmnxIPsecIsaGrpTable (18)
1091--        tmnxHsmdaMdaSchOvrTblLastChangd (19)
1092--        tmnxHsmdaMdaSchOvrTable (20)
1093--        tmnxFPTable (21)
1094--
1095--  tmnxPortObjs (4)
1096--  tmnxPppObjs (5)
1097--  tmnxChassisNotificationObjects (6)
1098--  tmnxPortNotificationObjects (7)
1099--  tmnxChassisAdminObjects (8)
1100--        tmnxChassisAdminCtrlObjs  (1)
1101--        tmnxChassisAdminValueObjs (2)
1102--              tSyncIfTimingAdmTable (1)
1103--  tmnxFRObjs (9)
1104--  tmnxQosAppObjs (10)
1105--
1106
1107--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
1108--
1109--      The Chassis Group
1110--
1111
1112
1113tmnxChassisTotalNumber OBJECT-TYPE
1114    SYNTAX      INTEGER (1..32)
1115    MAX-ACCESS  read-only
1116    STATUS      current
1117    DESCRIPTION
1118        "The number of chassis installed in this system.  For the first
1119         release of the Alcatel-Lucent 7x50 series product, there is only
1120         1 chassis per system.  A multi-chassis system model is supported
1121         to allow for future product expansion."
1122    ::= { tmnxChassisObjs 1 }
1123
1124tmnxChassisLastChange   OBJECT-TYPE
1125    SYNTAX      TimeStamp
1126    MAX-ACCESS  read-only
1127    STATUS      current
1128    DESCRIPTION
1129        "The value of sysUpTime when the tmnxChassisTable was last changed."
1130    ::= { tmnxChassisObjs 2 }
1131
1132tmnxChassisTable OBJECT-TYPE
1133    SYNTAX  SEQUENCE OF TmnxChassisEntry
1134    MAX-ACCESS  not-accessible
1135    STATUS      current
1136    DESCRIPTION
1137        "The chassis table has an entry for each chassis in the system."
1138    ::= { tmnxChassisObjs 3 }
1139
1140tmnxChassisEntry    OBJECT-TYPE
1141    SYNTAX      TmnxChassisEntry
1142    MAX-ACCESS  not-accessible
1143    STATUS      current
1144    DESCRIPTION
1145        "Each row entry represents a chassis in the system.  The agent
1146         creates the row for the first chassis in the system, with
1147         tmnxChassisIndex = 1, which is auto-discovered by the active CPM
1148         card.  Additional chassis entries can be created and deleted via
1149         SNMP SET operations.  Creation requires a SET request containing
1150         at least tmnxChassisAdminMode and tmnxChassisRowStatus.  Note
1151         that the first Alcatel-Lucent 7x50 series product release does not
1152         support multiple chassis, therefore there will not be more
1153         than one row entry in this table; attempts to create additional
1154         rows in this table will be denied."
1155    INDEX       { tmnxChassisIndex }
1156    ::= { tmnxChassisTable 1 }
1157
1158TmnxChassisEntry ::=
1159    SEQUENCE {
1160        tmnxChassisIndex                 TmnxChassisIndex,
1161        tmnxChassisRowStatus             RowStatus,
1162        tmnxChassisName                  TNamedItemOrEmpty,
1163        tmnxChassisType                  TmnxChassisType,
1164        tmnxChassisLocation              TItemDescription,
1165        tmnxChassisCoordinates           TItemDescription,
1166        tmnxChassisNumSlots              Unsigned32,
1167        tmnxChassisNumPorts              Unsigned32,
1168        tmnxChassisNumPwrSupplies        Unsigned32,
1169        tmnxChassisNumFanTrays           Unsigned32,
1170        tmnxChassisNumFans               Unsigned32,
1171        tmnxChassisCriticalLEDState      TmnxLEDState,
1172        tmnxChassisMajorLEDState         TmnxLEDState,
1173        tmnxChassisMinorLEDState         TmnxLEDState,
1174        tmnxChassisBaseMacAddress        MacAddress,
1175        tmnxChassisCLLICode              DisplayString,
1176        tmnxChassisReboot                TmnxActionType,
1177        tmnxChassisUpgrade               TmnxActionType,
1178        tmnxChassisAdminMode             TmnxChassisMode,
1179        tmnxChassisOperMode              TmnxChassisMode,
1180        tmnxChassisModeForce             TmnxActionType,
1181        tmnxChassisUpdateWaitTime        Unsigned32,
1182        tmnxChassisUpdateTimeLeft        Unsigned32,
1183        tmnxChassisOverTempState         INTEGER,
1184        tmnxChassisMixedModeIomAdminMode TmnxEnabledDisabled,
1185        tmnxChassisMixedModeIomUpgrList  BITS,
1186        tmnxChassisRedForcedSingleSfm    TruthValue
1187    }
1188
1189tmnxChassisIndex    OBJECT-TYPE
1190    SYNTAX      TmnxChassisIndex
1191    MAX-ACCESS  not-accessible
1192    STATUS      current
1193    DESCRIPTION
1194        "The unique value which identifies this chassis in the system.
1195         The first release of the product only supports a single chassis
1196         in the system."
1197    ::= { tmnxChassisEntry 1 }
1198
1199tmnxChassisRowStatus        OBJECT-TYPE
1200    SYNTAX      RowStatus
1201    MAX-ACCESS  read-create
1202    STATUS      current
1203    DESCRIPTION
1204        "The row status.  The creation or deletion of a chassis entry causes
1205         creation or deletion of corresponding entries in the tmnxCardTable with
1206         the same tmnxChassisIndex value.  Note, the agent will disallow
1207         chassis deletion if its entries in the card table have not first been
1208         put into the proper state for removal.  The row entry for
1209         tmnxChassisIndex equal 1 cannot be deleted."
1210    ::= { tmnxChassisEntry 2 }
1211
1212tmnxChassisName     OBJECT-TYPE
1213    SYNTAX      TNamedItemOrEmpty
1214    MAX-ACCESS  read-create
1215    STATUS      current
1216    DESCRIPTION
1217        "The administrative name assigned this chassis.  Setting
1218         tmnxChassisName to the empty string, ''H, resets tmnxChassisName
1219         to the TiMOS default value."
1220    DEFVAL      { ''H }
1221    ::= { tmnxChassisEntry 3 }
1222
1223
1224tmnxChassisType     OBJECT-TYPE
1225    SYNTAX      TmnxChassisType
1226    MAX-ACCESS  read-only
1227    STATUS      current
1228    DESCRIPTION
1229        "The type of chassis used in this Alcatel-Lucent 7x50 system.  The value
1230         of tmnxChassisType is the tmnxChassisTypeIndex for the entry in the
1231         tmnxChassisTypeTable that represents the Alcatel-Lucent SROS series
1232         chassis model for this system.  Chassis types are distinguished by
1233         their backplane type."
1234    ::= { tmnxChassisEntry 4 }
1235
1236tmnxChassisLocation OBJECT-TYPE
1237    SYNTAX      TItemDescription
1238    MAX-ACCESS  read-create
1239    STATUS      current
1240    DESCRIPTION
1241        "A user supplied string that indicates the on site location of this
1242         chassis.  This could used for a Common Language Location Identifier,
1243         CLLI, code string if desired.
1244
1245         A CLLI code is an 11-character standardized geographic identifier that
1246         uniquely identifies the geographic location of places and certain
1247         functional categories of equipment unique to the telecommunications
1248         industry.
1249
1250         All valid CLLI codes are created, updated and maintained in the
1251         Central Location Online Entry System (CLONES) database."
1252    DEFVAL      { ''H }
1253    ::= { tmnxChassisEntry 5 }
1254
1255tmnxChassisCoordinates   OBJECT-TYPE
1256    SYNTAX      TItemDescription
1257    MAX-ACCESS  read-create
1258    STATUS      current
1259    DESCRIPTION
1260        "A user supplied string that indicates the Global Positioning
1261         System (GPS) coordinates for the location of this chassis.
1262
1263            N 45 58 23, W 34 56 12
1264            N37 37' 00 latitude, W122 22' 00 longitude
1265            N36*39.246'  W121*40.121'
1266
1267         Two-dimensional GPS positioning offers latitude and longitude
1268         information as a four dimensional vector:
1269
1270            <Direction, hours, minutes, seconds>
1271
1272         where Direction is one of the four basic values: N, S, W, E; hours
1273         ranges from 0 to 180 (for latitude) and 0 to 90 for longitude, and,
1274         finally, minutes and seconds range from 0 to 60.
1275
1276         Thus <W, 122, 56, 89> is an example of longitude and <N, 85, 66, 43>
1277         is an example of latitude.
1278
1279         Four bytes of addressing space (one byte for each of the four
1280         dimensions) are necessary to store latitude and four bytes are also
1281         sufficient to store longitude. Thus eight bytes total are necessary
1282         to address the whole surface of earth with precision down to 0.1
1283         mile!  Notice that if we desired precision down to 0.001 mile (1.8
1284         meters) then we would need just five bytes for each component, or ten
1285         bytes together for the full address (as military versions provide)."
1286        DEFVAL      { ''H }
1287    ::= { tmnxChassisEntry 6 }
1288
1289tmnxChassisNumSlots OBJECT-TYPE
1290    SYNTAX      Unsigned32
1291    MAX-ACCESS  read-only
1292    STATUS      current
1293    DESCRIPTION
1294        "The number of slots in this chassis that are available for plug-in
1295         cards.  This includes both fabric and IOM cards"
1296    ::= { tmnxChassisEntry 7 }
1297
1298tmnxChassisNumPorts OBJECT-TYPE
1299    SYNTAX      Unsigned32
1300    MAX-ACCESS  read-only
1301    STATUS      current
1302    DESCRIPTION
1303        "The total number of ports currently installed in this chassis.
1304         This count does not include the Ethernet ports on the CPM cards
1305         that are used for management access."
1306    ::= { tmnxChassisEntry  8 }
1307
1308tmnxChassisNumPwrSupplies   OBJECT-TYPE
1309    SYNTAX      Unsigned32
1310    MAX-ACCESS  read-only
1311    STATUS      current
1312    DESCRIPTION
1313        "The total number of power supplies installed in this chassis."
1314    ::= { tmnxChassisEntry 9 }
1315
1316tmnxChassisNumFanTrays  OBJECT-TYPE
1317    SYNTAX      Unsigned32
1318    MAX-ACCESS  read-only
1319    STATUS      current
1320    DESCRIPTION
1321        "The total number of fan trays installed in this chassis."
1322    ::= { tmnxChassisEntry 10 }
1323
1324tmnxChassisNumFans  OBJECT-TYPE
1325    SYNTAX      Unsigned32
1326    MAX-ACCESS  read-only
1327    STATUS      current
1328    DESCRIPTION
1329        "The total number of fans installed in this chassis."
1330    ::= { tmnxChassisEntry 11 }
1331
1332tmnxChassisCriticalLEDState    OBJECT-TYPE
1333    SYNTAX      TmnxLEDState
1334    MAX-ACCESS  read-only
1335    STATUS      current
1336    DESCRIPTION
1337        "The current state of the Critical LED in this chassis."
1338    ::= { tmnxChassisEntry 12 }
1339
1340tmnxChassisMajorLEDState    OBJECT-TYPE
1341    SYNTAX      TmnxLEDState
1342    MAX-ACCESS  read-only
1343    STATUS      current
1344    DESCRIPTION
1345        "The current state of the Major LED in this chassis."
1346    ::= { tmnxChassisEntry 13 }
1347
1348tmnxChassisMinorLEDState    OBJECT-TYPE
1349    SYNTAX      TmnxLEDState
1350    MAX-ACCESS  read-only
1351    STATUS      current
1352    DESCRIPTION
1353        "The current state of the Minor LED in this chassis."
1354    ::= { tmnxChassisEntry 14 }
1355
1356tmnxChassisBaseMacAddress   OBJECT-TYPE
1357    SYNTAX      MacAddress
1358    MAX-ACCESS  read-only
1359    STATUS      current
1360    DESCRIPTION
1361        "The base chassis ethernet MAC address.  Special purpose MAC
1362         addresses used by the system software are constructed as
1363         offsets from this base address."
1364    ::= { tmnxChassisEntry 15 }
1365
1366tmnxChassisCLLICode   OBJECT-TYPE
1367    SYNTAX      DisplayString
1368    MAX-ACCESS  read-create
1369    STATUS      current
1370    DESCRIPTION
1371        "A Common Language Location Identifier (CLLI) code is an 11-character
1372         standardized geographic identifier that uniquely identifies the
1373         geographic location of places and certain functional categories of
1374         equipment unique to the telecommunications industry.
1375         If the set on this object specifies a non-null string, the string will
1376         automatically be truncated or padded(with spaces) to 11 characters."
1377    ::= { tmnxChassisEntry 16 }
1378
1379tmnxChassisReboot      OBJECT-TYPE
1380    SYNTAX      TmnxActionType
1381    MAX-ACCESS  read-create
1382    STATUS      current
1383    DESCRIPTION
1384        "Setting this tmnxChassisReboot to 'doAction' causes a soft-reboot
1385         of the entire chassis including all the CPM and IOM cards.
1386
1387         Note that the reboot action is likely to occur before the SNMP
1388         SET response can be transmitted."
1389    DEFVAL { notApplicable }
1390    ::= { tmnxChassisEntry 17 }
1391
1392tmnxChassisUpgrade      OBJECT-TYPE
1393    SYNTAX      TmnxActionType
1394    MAX-ACCESS  read-create
1395    STATUS      current
1396    DESCRIPTION
1397        "Setting this tmnxChassisUpgrade to 'doAction' causes an upgrade
1398         of all firmware and a reboot of the entire chassis including all
1399         the CPM and IOM cards.
1400
1401         CAUTION: This upgrade and reboot may take several minutes to
1402         complete.  The chassis MUST NOT be reset or powered down,
1403         nor cards inserted or removed, during this process.  Any of
1404         these prohibited actions may cause the cards to be rendered
1405         inoperable.
1406
1407         tmnxChassisUpgrade and tmnxChassisReboot must be set
1408         together in the same SNMP SET request PDU or else the SET request
1409         will fail with an inconsistentValue error.
1410
1411         Note that the reboot action is likely to occur before the SNMP
1412         SET response can be transmitted."
1413    DEFVAL { notApplicable }
1414    ::= { tmnxChassisEntry 18 }
1415
1416tmnxChassisAdminMode     OBJECT-TYPE
1417    SYNTAX      TmnxChassisMode
1418    MAX-ACCESS  read-create
1419    STATUS      current
1420
1421    DESCRIPTION
1422        "The value of tmnxChassisAdminMode specifies the scaling and feature
1423         set for all of the IOM cards in the chassis.  Setting
1424         tmnxChassisAdminMode to a particular mode corresponds to the scaling
1425         and feature sets supported on that IOM card type. The following table
1426         describes the maximum mode capable per IOM (ie. 'modeC' scaling and
1427         feature sets cannot be supported on either the iom-20g or the
1428         iom-20g-b):
1429
1430              IOM                MODE (maximum)
1431              ----------------   --------------
1432                iom-20g            modeA
1433                iom-20g-b          modeB
1434                iom2-20g           modeC
1435                iom3-xp/imm        modeD
1436
1437         An attempt to change the value of tmnxChassisAdminMode from a lesser
1438         mode to a greater mode (ie. Upgrading from 'modeA' to 'modeB') without
1439         also setting tmnxChassisModeForce to a value of 'doAction' in the same
1440         SNMP SET request, will fail with an inconsistentValue error if there
1441         are any IOM cards in the chassis with a tmnxCardAssignedType value that
1442         does not support the new mode.
1443
1444         Changing the value of tmnxChassisAdminMode from a greater mode to a
1445         lesser mode (ie. Downgrading from 'modeC' to 'modeA') will not take
1446         effect until after saving the configuration and rebooting the system."
1447
1448    DEFVAL { modeA }
1449    ::= { tmnxChassisEntry 19 }
1450
1451tmnxChassisOperMode OBJECT-TYPE
1452    SYNTAX      TmnxChassisMode
1453    MAX-ACCESS  read-only
1454    STATUS      current
1455
1456    DESCRIPTION
1457        "The value of tmnxChassisOperMode indicates the operational scaling
1458         and feature set for all IOM cards in the chassis. Changing the value
1459         of tmnxChassisAdminMode from a greater mode to a lesser mode
1460         (downgrade) will result in tmnxChassisAdminMode indicating the new mode
1461         while tmnxChassisOperMode indicates previous mode until the
1462         configuration is saved and the system rebooted, at which point, the
1463         actual downgrade will take effect and both tmnxChassisAdminMode and
1464         tmnxChassisOperMode will indicate the new mode.
1465
1466         Upgrading from a lesser mode to a greater mode (ie. From 'modeA' to
1467         'modeB') will take effect immediately and the tmnxChassisOperMode will
1468         indicate the same mode as that of tmnxChassisAdminMode."
1469    ::= { tmnxChassisEntry 20 }
1470
1471tmnxChassisModeForce     OBJECT-TYPE
1472    SYNTAX      TmnxActionType
1473    MAX-ACCESS  read-create
1474    STATUS      current
1475    DESCRIPTION
1476        "Setting tmnxChassisModeForce to a value of 'doAction' in the
1477         same SNMP SET request where tmnxChassisAdminMode is set to a greater
1478         mode than the current mode (ie. New mode 'modeB', while current is
1479         'modeA') allows the chassis to be upgraded to to the new mode even if
1480         there are IOM cards in the chassis with a tmnxCardAssignedType value
1481         that does not support the new mode.
1482
1483         An attempt to set tmnxChassisModeForce to 'doAction' without
1484         also setting tmnxChassisAdminMode, in the same SNMP SET request
1485         will fail with an inconsistentValue error."
1486
1487    DEFVAL { notApplicable }
1488    ::= { tmnxChassisEntry 21 }
1489
1490tmnxChassisUpdateWaitTime      OBJECT-TYPE
1491    SYNTAX      Unsigned32 (15..600)
1492    UNITS       "seconds"
1493    MAX-ACCESS  read-create
1494    STATUS      obsolete
1495    DESCRIPTION
1496        "The value of tmnxChassisUpdateWaitTime specifies the time to wait
1497         before rebooting IOM cards running older software versions following
1498         a software upgrade or downgrade activity switchover. This object
1499         was obsoleted in release 5.0."
1500    DEFVAL { 15 }
1501    ::= { tmnxChassisEntry 22 }
1502
1503tmnxChassisUpdateTimeLeft      OBJECT-TYPE
1504    SYNTAX      Unsigned32
1505    UNITS       "seconds"
1506    MAX-ACCESS  read-only
1507    STATUS      current
1508    DESCRIPTION
1509        "Following a software upgrade or downgrade activity switchover,
1510         the value of tmnxChassisUpdateTimeLeft indicates the time remaining
1511         before IOM cards or MDAs running older software versions will be
1512         rebooted."
1513    ::= { tmnxChassisEntry 23 }
1514
1515tmnxChassisOverTempState    OBJECT-TYPE
1516    SYNTAX      INTEGER {
1517                    stateOk       (1),
1518                    stateOverTemp (2)
1519                }
1520    MAX-ACCESS  read-only
1521    STATUS      current
1522    DESCRIPTION
1523        "The current Over Temperature state of this chassis.
1524
1525         stateOk         Indicates chassis is below the temperature threshold.
1526         stateOverTemp   Indicates chassis is above the temperature threshold.
1527         "
1528    ::= { tmnxChassisEntry 24 }
1529
1530tmnxChassisMixedModeIomAdminMode    OBJECT-TYPE
1531    SYNTAX      TmnxEnabledDisabled
1532    MAX-ACCESS  read-create
1533    STATUS      current
1534    DESCRIPTION
1535        "The value of tmnxChassisMixedModeIomAdminMode specifies if the chassis
1536         should allow functionally to run with a mixture of forwarding hardware.
1537
1538         When 'enabled(1)' on a 7450 chassis it allows SR functionality to be
1539         configured. SR functionality is a superset of ESS functionality.
1540         Once tmnxChassisMixedModeIomAdminMode is enabled, additional IOMs can
1541         be converted to SR functionality by setting the tmnxCardCapability
1542         field of the corresponding tmnxCardEntry.
1543
1544         When 'enabled(1)' on a 7750 chassis it allows allows IPv6 functionality
1545         without requiring chassis mode C or better.
1546
1547         tmnxChassisMixedModeIomAdminMode is only applicable when tmnxChassisType
1548         indicates the chassis type is 7450 ESS-6, 7450 ESS-6v, 7450 ESS-7,
1549         7450 ESS-12, 7750 SR-7 or 7750 SR-12."
1550    DEFVAL { disabled }
1551    ::= { tmnxChassisEntry 25 }
1552
1553tmnxChassisMixedModeIomUpgrList    OBJECT-TYPE
1554    SYNTAX      BITS {
1555                    iomSlot1   (0), -- numbering must start at zero.
1556                    iomSlot2   (1),
1557                    iomSlot3   (2),
1558                    iomSlot4   (3),
1559                    iomSlot5   (4),
1560                    iomSlot6   (5),
1561                    iomSlot7   (6),
1562                    iomSlot8   (7),
1563                    iomSlot9   (8),
1564                    iomSlot10  (9)
1565                }
1566    MAX-ACCESS  read-create
1567    STATUS      current
1568    DESCRIPTION
1569        "The value of tmnxChassisMixedModeIomUpgrList specifies the list of
1570         IOM slots which are to operate with SR functionality on the 7450
1571         chassis.
1572
1573         tmnxChassisMixedModeIomUpgrList is only applicable when tmnxChassisType
1574         indicates the chassis type is 7450 ESS-7 or 7450 ESS-12, and should
1575         only be set when enabling mixed-mode.
1576
1577         tmnxChassisMixedModeIomUpgrList is a bitmap, with a bit for each IOM
1578         slot on the chassis.  If the bit for a particular IOM slot is '1', the
1579         SR functionality will be enabled on the IOM when enabling mixed-mode.
1580         If the bit is set to '0', the IOM will continue to operate with ESS
1581         functionality.
1582
1583         To set a particular bit to '1':
1584         1.  The IOM slot must have a configured type of iom3-xp, or any type of
1585             IMM.
1586         2.  The installed IOM/IMM must be a 7750 IOM/IMM.  The platform type
1587             for an IOM/IMM can be read using tmnxHwEquippedPlatform.
1588         3.  tmnxChassisMixedModeIomAdminMode must be set to 'enabled (1)' in
1589             the same Set request packet."
1590    DEFVAL { {} }
1591    ::= { tmnxChassisEntry 26 }
1592
1593tmnxChassisRedForcedSingleSfm   OBJECT-TYPE
1594    SYNTAX      TruthValue
1595    MAX-ACCESS  read-create
1596    STATUS      current
1597    DESCRIPTION
1598        "Setting this variable to 'true' forces the IGP single-SFM-overload
1599         state to 'overload' in the router instances where the value of the
1600         object TIMETRA-VRTR-MIB::vRtrSingleSfmOverloadAdminState is equal to
1601         'inService'."
1602    DEFVAL { false }
1603    ::= { tmnxChassisEntry 27 }
1604
1605--
1606--  Fan Table
1607--
1608
1609tmnxChassisFanTable OBJECT-TYPE
1610    SYNTAX      SEQUENCE OF TmnxChassisFanEntry
1611    MAX-ACCESS  not-accessible
1612    STATUS      current
1613    DESCRIPTION
1614        "This table contains information about fan trays."
1615    ::= { tmnxChassisObjs 4 }
1616
1617tmnxChassisFanEntry OBJECT-TYPE
1618    SYNTAX      TmnxChassisFanEntry
1619    MAX-ACCESS  not-accessible
1620    STATUS  current
1621    DESCRIPTION
1622        "Contains information regarding a fan tray."
1623    INDEX       { tmnxChassisIndex, tmnxChassisFanIndex }
1624    ::= { tmnxChassisFanTable 1 }
1625
1626TmnxChassisFanEntry ::=
1627     SEQUENCE {
1628        tmnxChassisFanIndex         Unsigned32,
1629        tmnxChassisFanOperStatus    TmnxDeviceState,
1630        tmnxChassisFanSpeed         INTEGER,
1631        tmnxChassisFanRevision      INTEGER
1632    }
1633
1634tmnxChassisFanIndex OBJECT-TYPE
1635    SYNTAX      Unsigned32 (1..31)
1636    MAX-ACCESS  not-accessible
1637    STATUS      current
1638    DESCRIPTION
1639        "The unique value which identifies a specific fan tray in the
1640         chassis."
1641    ::= { tmnxChassisFanEntry 1 }
1642
1643tmnxChassisFanOperStatus OBJECT-TYPE
1644    SYNTAX      TmnxDeviceState
1645    MAX-ACCESS  read-only
1646    STATUS      current
1647    DESCRIPTION
1648        "Current status of the Fan tray."
1649    ::= { tmnxChassisFanEntry 2 }
1650
1651tmnxChassisFanSpeed     OBJECT-TYPE
1652    SYNTAX      INTEGER {
1653                    notApplicable (0),
1654                    unknown (1),
1655                    halfSpeed (2),
1656                    fullSpeed (3),
1657                    lowSpeed (4)
1658                }
1659    MAX-ACCESS  read-only
1660    STATUS  current
1661    DESCRIPTION
1662        "The value of tmnxChassisFanSpeed indicates if the fans in this
1663         fan tray are running at 'lowSpeed', 'halfSpeed' or 'fullSpeed'."
1664    ::= { tmnxChassisFanEntry 3 }
1665
1666tmnxChassisFanRevision           OBJECT-TYPE
1667    SYNTAX      INTEGER {
1668                    unknown   (0),
1669                    fan1      (1),
1670                    hfFan2    (2)
1671                }
1672    MAX-ACCESS  read-only
1673    STATUS      current
1674    DESCRIPTION
1675        "The value of tmnxChassisFanRevision indicates the fan tray revision.
1676               fan1   - represents the original fan tray.
1677               hfFan2 - represents the high-flow fan tray; second revision."
1678    ::= { tmnxChassisFanEntry 4 }
1679
1680--
1681--  Power Supply table
1682--
1683
1684tmnxChassisPowerSupplyTable OBJECT-TYPE
1685    SYNTAX      SEQUENCE OF TmnxChassisPowerSupplyEntry
1686    MAX-ACCESS  not-accessible
1687    STATUS      current
1688    DESCRIPTION
1689        "This table contains information about power supply trays, also known as
1690         PEMs (Power Entry Modules)."
1691    ::= { tmnxChassisObjs 5 }
1692
1693tmnxChassisPowerSupplyEntry OBJECT-TYPE
1694    SYNTAX      TmnxChassisPowerSupplyEntry
1695    MAX-ACCESS  not-accessible
1696    STATUS  current
1697    DESCRIPTION
1698        "Contains information regarding a power supply tray."
1699    INDEX  { tmnxChassisIndex, tmnxChassisPowerSupplyId }
1700    ::= { tmnxChassisPowerSupplyTable 1 }
1701
1702TmnxChassisPowerSupplyEntry ::=
1703    SEQUENCE {
1704        tmnxChassisPowerSupplyId            Unsigned32,
1705        tmnxChassisPowerSupplyACStatus      TmnxDeviceState,
1706        tmnxChassisPowerSupplyDCStatus      TmnxDeviceState,
1707        tmnxChassisPowerSupplyTempStatus    TmnxDeviceState,
1708        tmnxChassisPowerSupplyTempThreshold Integer32,
1709        tmnxChassisPowerSupply1Status       TmnxDeviceState,
1710        tmnxChassisPowerSupply2Status       TmnxDeviceState,
1711        tmnxChassisPowerSupplyAssignedType  INTEGER,
1712        tmnxChassisPowerSupplyInputStatus   TmnxDeviceState,
1713        tmnxChassisPowerSupplyOutputStatus  TmnxDeviceState,
1714        tmnxChassisPowerSupplyPemType       TmnxChassisPemType
1715    }
1716
1717tmnxChassisPowerSupplyId OBJECT-TYPE
1718    SYNTAX      Unsigned32 (1..31)
1719    MAX-ACCESS  not-accessible
1720    STATUS      current
1721    DESCRIPTION
1722        "The unique identifier index for a power supply tray in the chassis."
1723    ::= { tmnxChassisPowerSupplyEntry 1 }
1724
1725tmnxChassisPowerSupplyACStatus OBJECT-TYPE
1726    SYNTAX      TmnxDeviceState
1727    MAX-ACCESS  read-only
1728    STATUS      current
1729    DESCRIPTION
1730        "If the value of tmnxChassisPowerSupplyACStatus is 'deviceStateOk',
1731         the input AC voltage is within range.  If the value is
1732         'deviceStateFailed', an AC voltage out of range condition has been
1733         detected. A value of 'deviceNotEquipped' indicates that the AC
1734         power supply is not present."
1735    ::= { tmnxChassisPowerSupplyEntry 2 }
1736
1737tmnxChassisPowerSupplyDCStatus OBJECT-TYPE
1738    SYNTAX      TmnxDeviceState
1739    MAX-ACCESS  read-only
1740    STATUS      current
1741    DESCRIPTION
1742        "If the value of tmnxChassisPowerSupplyDCStatus is 'deviceStateOk',
1743         the input DC voltage is within range.  If the value is
1744         'deviceStateFailed', an DC voltage out of range condition has been
1745         detected. A value of 'deviceNotEquipped' indicates that the DC
1746         power supply is not present."
1747    ::= { tmnxChassisPowerSupplyEntry 3 }
1748
1749tmnxChassisPowerSupplyTempStatus OBJECT-TYPE
1750    SYNTAX      TmnxDeviceState
1751    MAX-ACCESS  read-only
1752    STATUS      current
1753    DESCRIPTION
1754        "If the value of tmnxChassisPowerSupplyTempStatus is 'deviceStateOk',
1755         the current temperature is within acceptable range. If the value is
1756         'deviceStateFailed', a temperature too high condition has been
1757         detected."
1758    ::= { tmnxChassisPowerSupplyEntry 4 }
1759
1760tmnxChassisPowerSupplyTempThreshold   OBJECT-TYPE
1761    SYNTAX      Integer32
1762    UNITS       "degrees celsius"
1763    MAX-ACCESS  read-only
1764    STATUS      current
1765    DESCRIPTION
1766        "The temperature threshold for this power supply tray in degrees
1767         celsius.  When the temperature raises above
1768         tmnxChassisPowerSupplyTempThreshold, a 'temperature too high'
1769         event will be generated."
1770    ::= { tmnxChassisPowerSupplyEntry 5 }
1771
1772tmnxChassisPowerSupply1Status OBJECT-TYPE
1773    SYNTAX      TmnxDeviceState
1774    MAX-ACCESS  read-only
1775    STATUS      current
1776    DESCRIPTION
1777        "The overall status of an equipped power supply. For AC multiple power
1778         supplies, this represents the overall status of the first power supply
1779         in the tray (or shelf). For any other type, this represents the overall
1780         status of the power supply. If tmnxChassisPowerSupply1Status is
1781         'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A
1782         value of 'deviceStateFailed' represents a condition where at least one
1783         monitored status is in a failed state."
1784    ::= { tmnxChassisPowerSupplyEntry 6 }
1785
1786tmnxChassisPowerSupply2Status OBJECT-TYPE
1787    SYNTAX         TmnxDeviceState
1788    MAX-ACCESS     read-only
1789    STATUS         current
1790    DESCRIPTION
1791        "The overall status of an equipped power supply. For AC multiple power
1792         supplies, this represents the overall status of the second power supply
1793         in the tray (or shelf). For any other type, this field is unused and
1794         set to 'deviceNotEquipped'. If tmnxChassisPowerSupply2Status is
1795         'deviceStateOk', then all monitored statuses are 'deviceStateOk'. A
1796         value of 'deviceStateFailed' represents a condition where at least one
1797         monitored status is in a failed state."
1798    ::= { tmnxChassisPowerSupplyEntry 7 }
1799
1800tmnxChassisPowerSupplyAssignedType OBJECT-TYPE
1801    SYNTAX         INTEGER {
1802                       none (0),
1803                       dc (1),
1804                       acSingle (2),
1805                       acMultiple (3),
1806                       default (4)
1807                   }
1808    MAX-ACCESS     read-create
1809    STATUS         current
1810    DESCRIPTION
1811        "tmnxChassisPowerSupplyAssignedType configures the type of power supply
1812         for a platform. Based on the value assigned to this object, various
1813         power supply monitoring signals will be interpreted. For example, if
1814         a platform is provisioned to use DC power supplies, then the signal
1815         that indicates an AC power supply is missing can be ignored.
1816         The configuration of this object away from 'default (4)' is required
1817         for proper generation of traps and LED management."
1818    DEFVAL { default }
1819    ::= { tmnxChassisPowerSupplyEntry 8 }
1820
1821tmnxChassisPowerSupplyInputStatus OBJECT-TYPE
1822    SYNTAX         TmnxDeviceState
1823    MAX-ACCESS     read-only
1824    STATUS         current
1825    DESCRIPTION
1826        "If the value of tmnxChassisPowerSupplyInputStatus is 'deviceStateOk',
1827         the input voltage of the power supply is within range.  If the value
1828         is 'deviceStateFailed', an input voltage out of range condition has
1829         been detected. A value of 'deviceNotEquipped' indicates that the power
1830         supply is not present."
1831    ::= { tmnxChassisPowerSupplyEntry 9 }
1832
1833tmnxChassisPowerSupplyOutputStatus OBJECT-TYPE
1834    SYNTAX         TmnxDeviceState
1835    MAX-ACCESS     read-only
1836    STATUS         current
1837    DESCRIPTION
1838        "If the value of tmnxChassisPowerSupplyOutputStatus is 'deviceStateOk',
1839         the output voltage of the power supply is within range.  If the value
1840         is 'deviceStateFailed', an output voltage out of range condition has
1841         been detected. A value of 'deviceNotEquipped' indicates that the power
1842         supply is not present."
1843    ::= { tmnxChassisPowerSupplyEntry 10 }
1844
1845tmnxChassisPowerSupplyPemType         OBJECT-TYPE
1846    SYNTAX      TmnxChassisPemType
1847    MAX-ACCESS  read-only
1848    STATUS      current
1849    DESCRIPTION
1850        "The tmnxChassisPowerSupplyPemType indicates the Power Entry Module
1851         type installed in the PEM slot."
1852    ::= { tmnxChassisPowerSupplyEntry 11 }
1853
1854--
1855--  Alcatel-Lucent SROS series Chassis Type Defintion Table
1856--
1857tmnxChassisTypeTable OBJECT-TYPE
1858    SYNTAX      SEQUENCE OF TmnxChassisTypeEntry
1859    MAX-ACCESS  not-accessible
1860    STATUS      current
1861    DESCRIPTION
1862        "The chassis type table has an entry for each Alcatel-Lucent SROS
1863         series chassis model."
1864    ::= { tmnxChassisObjs 6 }
1865
1866tmnxChassisTypeEntry    OBJECT-TYPE
1867    SYNTAX      TmnxChassisTypeEntry
1868    MAX-ACCESS  not-accessible
1869    STATUS      current
1870    DESCRIPTION
1871        "Each row entry represents an Alcatel-Lucent SROS series Chassis
1872         model.  Rows in this table are created by the agent at initialization
1873         and cannot be created or destroyed by SNMP Get or Set requests."
1874    INDEX   { tmnxChassisTypeIndex }
1875    ::= { tmnxChassisTypeTable 1 }
1876
1877TmnxChassisTypeEntry ::=
1878    SEQUENCE {
1879        tmnxChassisTypeIndex        TmnxChassisType,
1880        tmnxChassisTypeName         TNamedItemOrEmpty,
1881        tmnxChassisTypeDescription  TItemDescription,
1882        tmnxChassisTypeStatus       TruthValue
1883    }
1884
1885tmnxChassisTypeIndex    OBJECT-TYPE
1886    SYNTAX      TmnxChassisType
1887    MAX-ACCESS  not-accessible
1888    STATUS      current
1889    DESCRIPTION
1890        "The unique index value which identifies this type of Alcatel-Lucent
1891         SROS series chassis model."
1892    ::= { tmnxChassisTypeEntry 1 }
1893
1894tmnxChassisTypeName     OBJECT-TYPE
1895    SYNTAX      TNamedItemOrEmpty
1896    MAX-ACCESS  read-only
1897    STATUS      current
1898    DESCRIPTION
1899        "The administrative name that identifies this type of Alcatel-Lucent
1900         SROS series chassis model.  This name string may be used in
1901         CLI commands to specify a particular chassis model type."
1902    ::= { tmnxChassisTypeEntry 2 }
1903
1904tmnxChassisTypeDescription  OBJECT-TYPE
1905    SYNTAX      TItemDescription
1906    MAX-ACCESS  read-only
1907    STATUS      current
1908    DESCRIPTION
1909        "A detailed description of this Alcatel-Lucent SROS series chassis
1910         model."
1911    ::= { tmnxChassisTypeEntry 3 }
1912
1913tmnxChassisTypeStatus       OBJECT-TYPE
1914    SYNTAX      TruthValue
1915    MAX-ACCESS  read-only
1916    STATUS      current
1917    DESCRIPTION
1918        "When tmnxChassisTypeStatus has a value of 'true' it indicates that
1919         this chassis model is supported in this revision of the management
1920         software.  When it has a value of 'false' there is no support."
1921    ::= { tmnxChassisTypeEntry 4 }
1922
1923
1924--
1925--  Alcatel-Lucent SROS series Hardware Components Table
1926--
1927tmnxHwLastChange   OBJECT-TYPE
1928    SYNTAX      TimeStamp
1929    MAX-ACCESS  read-only
1930    STATUS      current
1931    DESCRIPTION
1932        "The value of sysUpTime when the tmnxHwTable was last changed."
1933    ::= { tmnxChassisObjs 7 }
1934
1935tmnxHwTable OBJECT-TYPE
1936    SYNTAX  SEQUENCE OF TmnxHwEntry
1937    MAX-ACCESS  not-accessible
1938    STATUS      current
1939    DESCRIPTION
1940        "The tmnxHwTable has an entry for each managed hardware component
1941         in the Alcatel-Lucent SROS series system's chassis.  Examples of
1942         these hardware component types are IOM, Fabric, and CPM cards,
1943         MCM and CCM, and MDA modules.  Similar information for physical ports
1944         is in the tmnxPortObjs."
1945    ::= { tmnxChassisObjs 8 }
1946
1947tmnxHwEntry       OBJECT-TYPE
1948    SYNTAX      TmnxHwEntry
1949    MAX-ACCESS  not-accessible
1950    STATUS      current
1951    DESCRIPTION
1952        "Each row entry represents an Alcatel-Lucent SROS series manufactured
1953         hardware component.  Entries cannot be created and deleted via
1954         SNMP SET operations.  When an entry is created in one of the
1955         card tables, IOM, CPM, Fabric or MDA, a tmnxHwEntry is created
1956         for the common hardware management information for that card
1957         in that chassis.  When the card  is removed from the chassis,
1958         its corresponding tmnxHwEntry is deleted.
1959
1960         The tmnxHwIndex is bitmapped:
1961
1962         | 32       25 | 24       17 | 16        9 | 8         1 |
1963         +-------------+-------------+-------------+-------------+
1964         | TmnxHwClass |   00000000  |     Slot    |     number  |
1965         +-------------+-------------+-------------+-------------+
1966
1967         The Slot field is only used for components on cards in
1968         slots. It is zero for all others.
1969
1970         The number field starts from 1 and indicates which component.
1971         E.g. Power supply 1 or 2."
1972
1973
1974    INDEX   { tmnxChassisIndex, tmnxHwIndex }
1975    ::= { tmnxHwTable 1 }
1976
1977TmnxHwEntry ::=
1978    SEQUENCE {
1979        tmnxHwIndex                     TmnxHwIndex,
1980        tmnxHwID                        RowPointer,
1981        tmnxHwMfgString                 SnmpAdminString,
1982        tmnxHwMfgBoardNumber            OCTET STRING,
1983        tmnxHwSerialNumber              SnmpAdminString,
1984        tmnxHwManufactureDate           SnmpAdminString,
1985        tmnxHwClass                     TmnxHwClass,
1986        tmnxHwName                      TNamedItemOrEmpty,
1987        tmnxHwAlias                     TNamedItemOrEmpty,
1988        tmnxHwAssetID                   SnmpAdminString,
1989        tmnxHwCLEI                      SnmpAdminString,
1990        tmnxHwIsFRU                     TruthValue,
1991        tmnxHwContainedIn               Integer32,
1992        tmnxHwParentRelPos              Integer32,
1993        tmnxHwAdminState                INTEGER,
1994        tmnxHwOperState                 INTEGER,
1995        tmnxHwTempSensor                TruthValue,
1996        tmnxHwTemperature               Integer32,
1997        tmnxHwTempThreshold             Integer32,
1998        tmnxHwBootCodeVersion           DisplayString,
1999        tmnxHwSoftwareCodeVersion       DisplayString,
2000        tmnxHwSwLastBoot                DateAndTime,
2001        tmnxHwSwState                   INTEGER,
2002        tmnxHwAlarmState                TmnxAlarmState,
2003        tmnxHwLastAlarmEvent            RowPointer,
2004        tmnxHwClearAlarms               TmnxActionType,
2005        tmnxHwSwImageSource             INTEGER,
2006        tmnxHwMfgDeviations             SnmpAdminString,
2007        tmnxHwBaseMacAddress            MacAddress,
2008        tmnxHwFailureReason             DisplayString,
2009        tmnxHwEquippedPlatform          INTEGER,
2010        tmnxHwMfgAssemblyNumber         SnmpAdminString,
2011        tmnxHwFirmwareCodeVersion       DisplayString
2012    }
2013
2014tmnxHwIndex     OBJECT-TYPE
2015    SYNTAX      TmnxHwIndex
2016    MAX-ACCESS  not-accessible
2017    STATUS      current
2018    DESCRIPTION
2019        "The value of tmnxHwIndex is a unique index that identifies
2020         common management information for Alcatel-Lucent SROS series
2021         manufactured hardware components within the specified chassis."
2022    ::= { tmnxHwEntry 1 }
2023
2024tmnxHwID        OBJECT-TYPE
2025    SYNTAX      RowPointer
2026    MAX-ACCESS  read-only
2027    STATUS      current
2028    DESCRIPTION
2029        "The value of tmnxHwID is an object identifier that points to
2030         the table and row entry with additional management information
2031         specific to this hardware component's class."
2032    ::= { tmnxHwEntry 2 }
2033
2034tmnxHwMfgString     OBJECT-TYPE
2035    SYNTAX      SnmpAdminString (SIZE(0..253))
2036    MAX-ACCESS  read-only
2037    STATUS      current
2038    DESCRIPTION
2039        "The tmnxHwMfgString contains unspecified Alcatel-Lucent SROS series
2040         manufacturing information and includes the Alcatel-Lucent vendor
2041         information."
2042    ::= { tmnxHwEntry 3 }
2043
2044tmnxHwMfgBoardNumber    OBJECT-TYPE
2045    SYNTAX      OCTET STRING (SIZE(0..32))
2046    MAX-ACCESS  read-only
2047    STATUS      current
2048    DESCRIPTION
2049        "The tmnxHwMfgBoardNumber contains the part number information."
2050    ::= { tmnxHwEntry 4 }
2051
2052tmnxHwSerialNumber        OBJECT-TYPE
2053    SYNTAX      SnmpAdminString (SIZE(0..32))
2054    MAX-ACCESS  read-only
2055    STATUS      current
2056    DESCRIPTION
2057        "The unique Alcatel-Lucent SROS series serial number of the hardware
2058         component."
2059    ::= { tmnxHwEntry 5 }
2060
2061tmnxHwManufactureDate     OBJECT-TYPE
2062    SYNTAX      SnmpAdminString (SIZE(8))
2063    MAX-ACCESS  read-only
2064    STATUS      current
2065    DESCRIPTION
2066        "The manufacturing date of the hardware component in 'mmddyyyy'
2067         ascii format."
2068    ::= { tmnxHwEntry 6 }
2069
2070tmnxHwClass     OBJECT-TYPE
2071    SYNTAX      TmnxHwClass
2072    MAX-ACCESS  read-only
2073    STATUS      current
2074    DESCRIPTION
2075        "The value of tmnxHwClass  indicates the general hardware type of this
2076         component.  If no appropriate enumeration exists for this hardware
2077         component then the value 'other (1)' is used.  If the agent cannot
2078         identify this hardware component then the value 'unknown (2)' is
2079         used."
2080    ::= { tmnxHwEntry 7 }
2081
2082tmnxHwName      OBJECT-TYPE
2083    SYNTAX      TNamedItemOrEmpty
2084    MAX-ACCESS  read-only
2085    STATUS      current
2086    DESCRIPTION
2087        "The value of tmnxHwName is the name of the component as assigned
2088         by the system software itself and is suitable for use in CLI commands.
2089         This may be a text name such as 'console' or a port ID such as '2/2'.
2090
2091         If there is no predefined name then a zero length string is returned.
2092
2093         Note that the value of tmnxHwName for two component entries will
2094         be the same if the CLI does not distinguish between them, e.g.  the
2095         chassis slot-1 and the card in slot-1."
2096    ::= { tmnxHwEntry 8 }
2097
2098tmnxHwAlias        OBJECT-TYPE
2099    SYNTAX      TNamedItemOrEmpty
2100    MAX-ACCESS  read-write
2101    STATUS      current
2102    DESCRIPTION
2103        "The value of tmnxHwAlias is the administrative name assigned to this
2104         hardware component by the CLI user or network manager.  It is saved
2105         across re-initializations and reboots of the system.
2106
2107         The object tmnxHwAlias is not supported on rows where the tmnxHwClass
2108         is set to 'flashDiskModule (12)'. Attempts to set the tmnxHwAlias
2109         object on rows where it is not supported will result in an
2110         inconsistentValue error."
2111    DEFVAL      { ''H }
2112    ::= { tmnxHwEntry 9 }
2113
2114tmnxHwAssetID   OBJECT-TYPE
2115    SYNTAX      SnmpAdminString
2116    MAX-ACCESS  read-write
2117    STATUS      current
2118    DESCRIPTION
2119        "The value of tmnxHwAssetID is an administratively assigned asset
2120         tracking identifier for this hardware component.  It is saved across
2121         re-initializations and reboots of the system.  If no asset tracking
2122         information is associated with this hardware component, a zero-length
2123         string is returned to an SNMP get request.
2124
2125         The object tmnxHwAssetID is not supported on rows where the tmnxHwClass
2126         is set to 'flashDiskModule (12)'. Attempts to set the tmnxHwAssetID
2127         object on rows where it is not supported will result in an
2128         inconsistentValue error.
2129
2130         Some hardware components do not have asset tracking identifiers.
2131         Components for which tmnxHwIsFRU has a value of 'false' do not
2132         need their own unique asset tracking identifier.  In this case, the
2133         agent denies write access to this object and returns a zero-length
2134         string to an SNMP get request."
2135    DEFVAL      { ''H }
2136    ::= { tmnxHwEntry 10 }
2137
2138tmnxHwCLEI          OBJECT-TYPE
2139    SYNTAX      SnmpAdminString (SIZE(10))
2140    MAX-ACCESS  read-only
2141    STATUS      current
2142    DESCRIPTION
2143        "The Common Language Equipment Identifier, CLEI, code is a unique
2144         10-character identifier, that is fixed by the manufacturer.  It
2145         consists of ten alphanumeric characters.  The first seven characters
2146         present a concise summary of an equipment entity's circuit or
2147         transport capabilities, e.g., functional, electrical, bandwidth, etc.
2148         CLEI codes for plug-in or portable equipment with the same first
2149         seven characters (CLEI-7) are considered bidirectionally
2150         interchangeable and group under a G level record.  Most licensees
2151         plug-in inventories and records are controlled at the group level.
2152         The eighth character denotes the reference source used for coding
2153         the item, and the last two characters denote manufacturing vintage
2154         or version, and other complemental information.
2155
2156         A ten-character CLEI code that is developed for a specific piece of
2157         equipment is unique within the CLEI code universe and is used in A
2158         level records; the code is not assigned to any other equipment piece.
2159         Equipment is coded to a first or major application. When the same
2160         equipment is usable in another application or system, it is not
2161         recorded nor are additional codes developed for that purpose."
2162    REFERENCE
2163        "Bellcore (Telcordia Technologies) GR-485."
2164    ::= { tmnxHwEntry 11 }
2165
2166tmnxHwIsFRU     OBJECT-TYPE
2167    SYNTAX      TruthValue
2168    MAX-ACCESS  read-only
2169    STATUS      current
2170    DESCRIPTION
2171        "The value of tmnxHwIsFRU indicates whether or not this hardware
2172         component is a Field Replaceable Unit (FRU) or not.  Those components
2173         that are permanently contained within a FRU have a value of 'false'."
2174    ::= { tmnxHwEntry 12 }
2175
2176tmnxHwContainedIn   OBJECT-TYPE
2177    SYNTAX      Integer32 (0..2147483647)
2178    MAX-ACCESS  read-only
2179    STATUS      current
2180    DESCRIPTION
2181        "The value of tmnxHwContainedIn is the tmnxHwIndex value for the
2182         row entry of the hardware component that contains this component.
2183         A value of zero indicates that this component is not contained in any
2184         other component."
2185    ::= { tmnxHwEntry 13 }
2186
2187tmnxHwParentRelPos      OBJECT-TYPE
2188    SYNTAX      Integer32 (-1..2147483647)
2189    MAX-ACCESS  read-only
2190    STATUS      current
2191    DESCRIPTION
2192        "The value of tmnxHwParentRelPos indicates the relative position of
2193         this hardware component among all its 'sibling' components.  A sibling
2194         component shares the same instance values for tmnxHwContainedIn and
2195         tmnxHwClass objects.
2196
2197         If the associated value of tmnxHwContainedIn is zero, then the value -1
2198         is returned."
2199    ::= { tmnxHwEntry 14 }
2200
2201tmnxHwAdminState  OBJECT-TYPE
2202    SYNTAX      INTEGER {
2203                    noop (1),
2204                    inService (2),
2205                    outOfService (3),
2206                    diagnose (4),
2207                    operateSwitch (5)
2208                }
2209    MAX-ACCESS  read-write
2210    STATUS      current
2211    DESCRIPTION
2212        "The desired administrative status of this hardware component.  Write
2213         access will be denied for those components that do not have
2214         administrative status.  An attempt to set tmnxHwAdminState to
2215         'operateSwitch (5)' will fail if the hardware component is not part
2216         of a redundant pair.  Some examples of redundant hardware are the
2217         CPM cards and fabric cards."
2218    DEFVAL { noop }
2219    ::= { tmnxHwEntry 15 }
2220
2221tmnxHwOperState   OBJECT-TYPE
2222    SYNTAX      INTEGER {
2223                    unknown (1),
2224                    inService (2),
2225                    outOfService (3),
2226                    diagnosing (4),
2227                    failed (5),
2228                    booting (6),
2229                    empty (7),
2230                    provisioned (8),
2231                    unprovisioned (9),
2232                    upgrade (10),
2233                    downgrade (11),
2234                    inServiceUpgrade (12),
2235                    inServiceDowngrade (13),
2236                    resetPending (14),
2237                    softReset (15)
2238                }
2239    MAX-ACCESS  read-only
2240    STATUS      current
2241    DESCRIPTION
2242        "The actual operational status of this hardware component.
2243
2244         unknown (1)                Status cannot be determined
2245
2246         inService (2)              Online - If tmnxHwClass has a value of
2247                                    'ioModule (8)' or 'cpmModule (9), the
2248                                    card is present, booted, configured,
2249                                    and running.
2250
2251         outOfService (3)           Ready - The hardware component is OK
2252                                    but is down because tmnxHwAdminState has
2253                                    a value of 'outOfService (3)'.
2254
2255         diagnosing (4)             Not implemented.
2256
2257         failed (5)                 This hardware component has failed.  The
2258                                    value of tmnxHwFailureReason indicates
2259                                    the type of failure.  If tmnxHwClass has
2260                                    a value of 'ioModule(8)' or 'cpmModule(9)',
2261                                    there is a card in the slot but it has
2262                                    failed.
2263
2264         booting (6)                A card is in the transitional startup state.
2265
2266         empty (7)                  There is no card in the slot and it has
2267                                    not been pre-configured.
2268
2269         provisioned (8)            There is no card in the slot but it has
2270                                    been pre-configured.
2271
2272         unprovisioned (9)          There is a card in the slot but it is not
2273                                    configured.
2274
2275         upgrade (10)               Card software version is compatible with
2276                                    and newer than that running on the current
2277                                    active CPM.
2278
2279         downgrade (11)             Card software version is compatible with
2280                                    and older than that running on the current
2281                                    active CPM.
2282
2283         inServiceUpgrade (12)      Card is inService and the card software
2284                                    version is compatible with and newer than
2285                                    that running on the current active CPM.
2286                                    This state applies only to a standby CPM
2287                                    card. This enumeration is no longer
2288                                    supported as of release 5.0.
2289
2290         inServiceDowngrade (13)    Card is inService and the card software
2291                                    is compatible with and older than that
2292                                    running on the current active CPM.  This
2293                                    state applies only to a standby CPM card.
2294                                    This enumeration is no longer supported
2295                                    as of release 5.0.
2296
2297         resetPending (14)          Card is awaiting reset following an
2298                                    upgrade or downgrade activity switch.
2299                                    The card software version is upgrade
2300                                    or downgrade compatible but will be reset
2301                                    in order to update it to match the active
2302                                    CPM software.  The value of
2303                                    tmnxChassisUpdateWaitTime indicates the
2304                                    how long the system will wait following
2305                                    an upgrade or downgrade activity switch
2306                                    before it resets IOM cards.  This state
2307                                    applies only to IOM cards. This
2308                                    enumeration is no longer supported as of
2309                                    release 5.0.
2310
2311         softReset (15)             Card is performing a soft reset. The
2312                                    data path is active, but control path
2313                                    transitional changes are suspended until
2314                                    the card leaves this state.
2315        "
2316    ::= { tmnxHwEntry 16 }
2317
2318tmnxHwTempSensor    OBJECT-TYPE
2319    SYNTAX      TruthValue
2320    MAX-ACCESS  read-only
2321    STATUS      current
2322    DESCRIPTION
2323        "The value of tmnxHwTempSensor indicates whether or not this
2324         hardware component contains a temperature sensor."
2325    ::= { tmnxHwEntry 17 }
2326
2327tmnxHwTemperature OBJECT-TYPE
2328    SYNTAX      Integer32
2329    UNITS       "degrees celsius"
2330    MAX-ACCESS  read-only
2331    STATUS      current
2332    DESCRIPTION
2333        "The current temperature reading in degrees celsius from this hardware
2334         component's temperature sensor.  If this component does not contain
2335         a temperature sensor, then the value -1 is returned."
2336    ::= { tmnxHwEntry 18 }
2337
2338tmnxHwTempThreshold   OBJECT-TYPE
2339    SYNTAX     Integer32
2340    UNITS       "degrees celsius"
2341    MAX-ACCESS  read-only
2342    STATUS      current
2343    DESCRIPTION
2344        "The temperature threshold for this hardware component in degrees
2345         celsius.  When the value of tmnxHwTemperature raises above
2346         tmnxHwTempThreshold, a 'temperature too high' event will
2347         be generated."
2348    ::= { tmnxHwEntry 19 }
2349
2350tmnxHwBootCodeVersion     OBJECT-TYPE
2351    SYNTAX      DisplayString
2352    MAX-ACCESS  read-only
2353    STATUS      current
2354    DESCRIPTION
2355        "The version number of boot eprom on the card in this slot.
2356
2357         If no specific software program is associated with this hardware
2358         component then this object will contain a zero length string."
2359    ::= { tmnxHwEntry 20 }
2360
2361tmnxHwSoftwareCodeVersion OBJECT-TYPE
2362    SYNTAX      DisplayString
2363    MAX-ACCESS  read-only
2364    STATUS      current
2365    DESCRIPTION
2366        "The software product release version number for the software image
2367         currently running on this IOM or CPM card.
2368
2369         If no specific software program is associated with this hardware
2370         component then this object will contain a zero length string."
2371    ::= { tmnxHwEntry 21 }
2372
2373tmnxHwSwLastBoot  OBJECT-TYPE
2374    SYNTAX      DateAndTime
2375    MAX-ACCESS  read-only
2376    STATUS      current
2377    DESCRIPTION
2378        "The date and time the software running on this IOM or CPM card was
2379         last rebooted.
2380
2381         If this row entry represents a standby CPM card, the date and time
2382         indicated is when the standby completed its initial synchronization
2383         process and became ready to take over in case the active card fails
2384         or a manual switchover command is issued."
2385    ::= { tmnxHwEntry 22 }
2386
2387tmnxHwSwState     OBJECT-TYPE
2388    SYNTAX      INTEGER {
2389                    unknown (0),
2390                    hwFailure (1),
2391                    swFailure (2),
2392                    hwInitting (3),
2393                    swDownloading (4),
2394                    swInitting (5),
2395                    swInitted (6),
2396                    swRunning (7)
2397                }
2398    MAX-ACCESS  read-only
2399    STATUS      obsolete
2400    DESCRIPTION
2401        "The state of the software running on this IOM or CPM card.
2402
2403         The tmnxHwSwState object is obsolete.  The Alcatel-Lucent 7x50 platform
2404         cannot distinguish software status separate from the hardware
2405         status.  Instead of using this object, additional operational
2406         states have been added to tmnxHwOperState.
2407
2408         If no specific software program is associated with this hardware
2409         component then this object will contain a zero."
2410    ::= { tmnxHwEntry 23 }
2411
2412tmnxHwAlarmState    OBJECT-TYPE
2413    SYNTAX  TmnxAlarmState
2414    MAX-ACCESS  read-only
2415    STATUS  current
2416    DESCRIPTION
2417        "The value of tmnxHwAlarmState indicates the current alarm
2418         state for this hardware component."
2419    ::= { tmnxHwEntry 24 }
2420
2421tmnxHwLastAlarmEvent    OBJECT-TYPE
2422    SYNTAX  RowPointer
2423    MAX-ACCESS  read-only
2424    STATUS  current
2425    DESCRIPTION
2426        "The value of tmnxHwLastAlarmEvent indicates the object name
2427         and instance value that points to the row entry in the ALARM-MIB
2428         containing the most recent alarm associated with this hardware
2429         component.  If tmnxHwAlarmState has a value of 'alarmCleared(2)', the
2430         most recent alarm event will be in the cleared alarm table.  If it has
2431         a value of 'alarmActive(1)', the most recent alarm event will be in
2432         the active alarm table.  If the value of tmnxHwLastAlarmEvent is
2433         '0.0', either no hardware component alarm events have occurred since
2434         the system was last booted, or the last hardware component alarm event
2435         has aged out and its entry is no longer available in the ALARM-MIB
2436         tables."
2437    ::= { tmnxHwEntry 25 }
2438
2439tmnxHwClearAlarms OBJECT-TYPE
2440    SYNTAX      TmnxActionType
2441    MAX-ACCESS  read-write
2442    STATUS      current
2443    DESCRIPTION
2444        "Setting this action variable causes all the active alarms associated
2445         with this hardware component to be moved from the ALARM-MIB
2446         nlmActiveAlarmTable to the nlmClearedAlarmTable.  This action button
2447         is primarily meant for use as a code development aid.  This object may
2448         be removed from the TIMETRA-CHASSIS-MIB before product release."
2449    DEFVAL { notApplicable }
2450    ::= { tmnxHwEntry 26 }
2451
2452tmnxHwSwImageSource       OBJECT-TYPE
2453    SYNTAX      INTEGER {
2454                    unknown (0),
2455                    primary (1),
2456                    secondary (2),
2457                    tertiary (3)
2458                }
2459    MAX-ACCESS  read-only
2460    STATUS      current
2461    DESCRIPTION
2462        "The value of tmnxHwSwImageSource indicates the location in the
2463         Boot Options File (BOF) where the software image file was found
2464         when the system last rebooted."
2465    ::= { tmnxHwEntry 27 }
2466
2467tmnxHwMfgDeviations        OBJECT-TYPE
2468    SYNTAX      SnmpAdminString
2469    MAX-ACCESS  read-only
2470    STATUS      current
2471    DESCRIPTION
2472        "tmnxHwMfgDeviations contains a record of changes done by the
2473         manufacturing to the hardware or software and which is outside the
2474         normal revision control process."
2475    ::= { tmnxHwEntry 28 }
2476
2477tmnxHwBaseMacAddress        OBJECT-TYPE
2478    SYNTAX      MacAddress
2479    MAX-ACCESS  read-only
2480    STATUS      current
2481    DESCRIPTION
2482        "tmnxHwBaseMacAddress contains the base MAC address of the hardware
2483         component. It is applicable only if tmnxHwClass is of type 'chassis',
2484         'ioModule', 'cpmModule' or 'mdaModule'."
2485    ::= { tmnxHwEntry 29 }
2486
2487tmnxHwFailureReason OBJECT-TYPE
2488    SYNTAX      DisplayString
2489    MAX-ACCESS  read-only
2490    STATUS      current
2491    DESCRIPTION
2492        "tmnxHwFailureReason indicates the reason why a hardware component
2493         'failed' as indicated in tmnxHwOperState."
2494    ::= { tmnxHwEntry 30 }
2495
2496tmnxHwEquippedPlatform OBJECT-TYPE
2497    SYNTAX      INTEGER {
2498                    pfUnknown (0),
2499                    pf7750 (1),
2500                    pf7450 (2),
2501                    pf7710 (3)
2502                }
2503    MAX-ACCESS  read-only
2504    STATUS      current
2505    DESCRIPTION
2506        "The value of tmnxHwEquippedPlatform indicates the platform type
2507         of the installed hardware component, as read from the component's
2508         EEPROM.  For example, 'pf7750' is returned for an installed 7750
2509         iom3-xp.  pfUnknown is returned if the component's EEPROM is
2510         unreadable, or in the case of an empty slot."
2511   ::= { tmnxHwEntry 31 }
2512
2513tmnxHwMfgAssemblyNumber    OBJECT-TYPE
2514    SYNTAX      SnmpAdminString (SIZE(0..32))
2515    MAX-ACCESS  read-only
2516    STATUS      current
2517    DESCRIPTION
2518        "The value of tmnxHwMfgAssemblyNumber may contain an assembly number
2519         which indicates manufacturing differences for a given part number."
2520    ::= { tmnxHwEntry 32 }
2521
2522tmnxHwFirmwareCodeVersion OBJECT-TYPE
2523    SYNTAX      DisplayString
2524    MAX-ACCESS  read-only
2525    STATUS      current
2526    DESCRIPTION
2527        "The software product release version number associated with
2528         the firmware version currently programmed on this card.
2529
2530         If no specific software release is associated with this hardware
2531         component then this object will contain a zero length string."
2532    ::= { tmnxHwEntry 33 }
2533
2534--
2535--  Alcatel-Lucent SROS series Hardware Components Containment Table
2536--
2537tmnxHwContainsTable OBJECT-TYPE
2538    SYNTAX  SEQUENCE OF TmnxHwContainsEntry
2539    MAX-ACCESS  not-accessible
2540    STATUS      current
2541    DESCRIPTION
2542        "The tmnxHwContainsTable shows the container/containee relationship
2543         between entries in the tmnxHwTable.  The hardware component
2544         containment tree can be constructed from information in the
2545         tmnxHwTable, but this table provides the information in a more
2546         convenient format for the manager system to use."
2547    ::= { tmnxChassisObjs 9 }
2548
2549tmnxHwContainsEntry       OBJECT-TYPE
2550    SYNTAX      TmnxHwContainsEntry
2551    MAX-ACCESS  not-accessible
2552    STATUS      current
2553    DESCRIPTION
2554        "Each row entry represents a single container/containee relationship.
2555         Entries cannot be created and deleted via SNMP SET operations."
2556    INDEX   { tmnxHwIndex, tmnxHwContainedIndex }
2557    ::= { tmnxHwContainsTable 1 }
2558
2559TmnxHwContainsEntry ::=
2560    SEQUENCE {
2561        tmnxHwContainedIndex    TmnxHwIndex
2562    }
2563
2564tmnxHwContainedIndex    OBJECT-TYPE
2565    SYNTAX      TmnxHwIndex
2566    MAX-ACCESS  read-only
2567    STATUS      current
2568    DESCRIPTION
2569        "The value of tmnxHwIndex for the contained hardware component."
2570    ::= { tmnxHwContainsEntry 1 }
2571
2572--
2573--  Alcatel-Lucent 7710 SR series Chassis Control Module (CCM) Table
2574--
2575
2576tmnxCcmTable OBJECT-TYPE
2577    SYNTAX      SEQUENCE OF TmnxCcmEntry
2578    MAX-ACCESS  not-accessible
2579    STATUS      current
2580    DESCRIPTION
2581        "This table contains information about CCM."
2582    ::= { tmnxChassisObjs 10 }
2583
2584tmnxCcmEntry OBJECT-TYPE
2585    SYNTAX      TmnxCcmEntry
2586    MAX-ACCESS  not-accessible
2587    STATUS  current
2588    DESCRIPTION
2589        "Contains information regarding a CCM."
2590    INDEX       { tmnxChassisIndex, tmnxCcmIndex }
2591    ::= { tmnxCcmTable 1 }
2592
2593TmnxCcmEntry ::=
2594     SEQUENCE {
2595        tmnxCcmIndex            Unsigned32,
2596        tmnxCcmOperStatus       TmnxDeviceState,
2597        tmnxCcmHwIndex          TmnxHwIndex,
2598        tmnxCcmEquippedType     TmnxCcmType
2599    }
2600
2601tmnxCcmIndex OBJECT-TYPE
2602    SYNTAX      Unsigned32 (1..8)
2603    MAX-ACCESS  not-accessible
2604    STATUS      current
2605    DESCRIPTION
2606        "The unique value which identifies a specific CCM instance in the
2607         chassis."
2608    ::= { tmnxCcmEntry 1 }
2609
2610tmnxCcmOperStatus OBJECT-TYPE
2611    SYNTAX      TmnxDeviceState
2612    MAX-ACCESS  read-only
2613    STATUS      current
2614    DESCRIPTION
2615        "Current status of the CCM."
2616    ::= { tmnxCcmEntry 2 }
2617
2618tmnxCcmHwIndex     OBJECT-TYPE
2619    SYNTAX      TmnxHwIndex
2620    MAX-ACCESS  read-only
2621    STATUS  current
2622    DESCRIPTION
2623        "The value of tmnxCcmHwIndex is the index into the tmnxHwTable
2624         for the row entry that represents the hardware component information
2625         for this CCM."
2626    ::= { tmnxCcmEntry 3 }
2627
2628tmnxCcmEquippedType        OBJECT-TYPE
2629    SYNTAX      TmnxCcmType
2630    MAX-ACCESS  read-only
2631    STATUS      current
2632    DESCRIPTION
2633        "A bit-mask that identifies the CCM type that is physically
2634         inserted into this chassis.  There will not be more than one
2635         bit set at a time in tmnxCcmEquippedType."
2636    ::= { tmnxCcmEntry 4 }
2637
2638--
2639--  Chassis Control Module Type (CCM) Definition Table
2640--
2641tmnxCcmTypeTable OBJECT-TYPE
2642    SYNTAX      SEQUENCE OF TmnxCcmTypeEntry
2643    MAX-ACCESS  not-accessible
2644    STATUS      current
2645    DESCRIPTION
2646        "The card type table has an entry for each Alcatel-Lucent 7710 series
2647         Chassis Control Module (CCM) model."
2648    ::= { tmnxChassisObjs 11 }
2649
2650tmnxCcmTypeEntry    OBJECT-TYPE
2651    SYNTAX      TmnxCcmTypeEntry
2652    MAX-ACCESS  not-accessible
2653    STATUS      current
2654    DESCRIPTION
2655        "Each row entry represents an Alcatel-Lucent 7710 series CCM model.
2656         Rows in this table are created by the agent at initialization and
2657         cannot be created or destroyed by SNMP Get or Set requests."
2658    INDEX   { tmnxCcmTypeIndex }
2659    ::= { tmnxCcmTypeTable 1 }
2660
2661TmnxCcmTypeEntry ::=
2662    SEQUENCE {
2663        tmnxCcmTypeIndex        TmnxCcmType,
2664        tmnxCcmTypeName         TNamedItemOrEmpty,
2665        tmnxCcmTypeDescription  TItemDescription,
2666        tmnxCcmTypeStatus       TruthValue
2667    }
2668
2669tmnxCcmTypeIndex    OBJECT-TYPE
2670    SYNTAX      TmnxCcmType
2671    MAX-ACCESS  not-accessible
2672    STATUS      current
2673    DESCRIPTION
2674        "The unique index value which identifies this type of Alcatel-Lucent
2675         7710 series CCM model."
2676    ::= { tmnxCcmTypeEntry 1 }
2677
2678tmnxCcmTypeName     OBJECT-TYPE
2679    SYNTAX      TNamedItemOrEmpty
2680    MAX-ACCESS  read-only
2681    STATUS      current
2682    DESCRIPTION
2683        "The administrative name that identifies this type of Alcatel-Lucent
2684         7710 series CCM model.  This name string may be used in CLI
2685         commands to specify a particular card model type."
2686    ::= { tmnxCcmTypeEntry 2 }
2687
2688tmnxCcmTypeDescription  OBJECT-TYPE
2689    SYNTAX      TItemDescription
2690    MAX-ACCESS  read-only
2691    STATUS      current
2692    DESCRIPTION
2693        "A detailed description of this Alcatel-Lucent 7710 series CCM model."
2694    ::= { tmnxCcmTypeEntry 3 }
2695
2696tmnxCcmTypeStatus       OBJECT-TYPE
2697    SYNTAX      TruthValue
2698    MAX-ACCESS  read-only
2699    STATUS      current
2700    DESCRIPTION
2701        "When tmnxCcmTypeStatus has a value of 'true' it
2702        indicates that this CCM is supported in this revision of the
2703        management software.  When it has a value of 'false' there is no
2704        support."
2705    ::= { tmnxCcmTypeEntry 4 }
2706
2707--
2708--  Fan Components Definition Table
2709--
2710tmnxFanTrayComponentTable        OBJECT-TYPE
2711    SYNTAX      SEQUENCE OF TmnxFanTrayComponentEntry
2712    MAX-ACCESS  not-accessible
2713    STATUS      current
2714    DESCRIPTION
2715        "The Fan Tray Component table has an entry for every sub-component of a
2716         Fan Tray that has monitored states. Not all fan trays have monitored
2717         sub-components, in this case, this table will be empty for the given
2718         fan-tray."
2719    ::= { tmnxChassisObjs 12 }
2720
2721tmnxFanTrayComponentEntry        OBJECT-TYPE
2722    SYNTAX      TmnxFanTrayComponentEntry
2723    MAX-ACCESS  not-accessible
2724    STATUS      current
2725    DESCRIPTION
2726        "Each row entry represents a fan tray component.
2727         Rows in this table are created by the agent at initialization and
2728         cannot be created or destroyed by SNMP Get or Set requests."
2729    INDEX       { tmnxChassisIndex,
2730                  tmnxChassisFanIndex,
2731                  tmnxFanTrayCompIndex
2732                }
2733    ::= { tmnxFanTrayComponentTable 1 }
2734
2735TmnxFanTrayComponentEntry        ::= SEQUENCE {
2736    tmnxFanTrayCompIndex             Unsigned32,
2737    tmnxFanTrayCompSpeed             Gauge32
2738}
2739
2740tmnxFanTrayCompIndex             OBJECT-TYPE
2741    SYNTAX      Unsigned32
2742    MAX-ACCESS  not-accessible
2743    STATUS      current
2744    DESCRIPTION
2745        "The tmnxFanTrayCompIndex specifies an individual fan tray component."
2746    ::= { tmnxFanTrayComponentEntry 1 }
2747
2748tmnxFanTrayCompSpeed             OBJECT-TYPE
2749    SYNTAX      Gauge32 (0..100)
2750    UNITS       "percent"
2751    MAX-ACCESS  read-only
2752    STATUS      current
2753    DESCRIPTION
2754        "The tmnxFanTrayCompSpeed indicates the current speed of the fan tray
2755        component."
2756    ::= { tmnxFanTrayComponentEntry 2 }
2757
2758--
2759--  Hardware Resource Usage Table
2760--
2761 tmnxHwResourceTable             OBJECT-TYPE
2762     SYNTAX     SEQUENCE OF TmnxHwResourceEntry
2763     MAX-ACCESS not-accessible
2764     STATUS     current
2765     DESCRIPTION
2766         "The tmnxHwResourceTable has an entry for each managed hardware
2767          component in the Alcatel-Lucent SROS series system's chassis that
2768          supports resource monitoring. Hardware components that do not support
2769          resource monitoring will not show up in this table.
2770
2771          Rows in this table are created by the agent at initialization and
2772          cannot be created or destroyed by SNMP Get or Set requests."
2773     ::= { tmnxChassisObjs 13 }
2774
2775tmnxHwResourceEntry              OBJECT-TYPE
2776    SYNTAX      TmnxHwResourceEntry
2777    MAX-ACCESS  not-accessible
2778    STATUS      current
2779    DESCRIPTION
2780        "Each tmnxHwResourceEntry row consists of the current resource levels
2781         for a particular managed hardware component."
2782    INDEX { tmnxChassisIndex, tmnxHwIndex }
2783    ::= { tmnxHwResourceTable 1 }
2784
2785TmnxHwResourceEntry              ::= SEQUENCE {
2786    tmnxHwResourceCurrentVoltage     Integer32,
2787    tmnxHwResourcePeakVoltage        Integer32,
2788    tmnxHwResourcePeakVoltageTime    TimeStamp,
2789    tmnxHwResourceMinVoltage         Integer32,
2790    tmnxHwResourceMinVoltageTime     TimeStamp,
2791
2792    tmnxHwResourceCurrentWattage     Integer32,
2793    tmnxHwResourcePeakWattage        Integer32,
2794    tmnxHwResourcePeakWattageTime    TimeStamp,
2795    tmnxHwResourceMinWattage         Integer32,
2796    tmnxHwResourceMinWattageTime     TimeStamp,
2797
2798    tmnxHwResourceCurrentAmperage    Integer32,
2799    tmnxHwResourcePeakAmperage       Integer32,
2800    tmnxHwResourcePeakAmperageTime   TimeStamp,
2801    tmnxHwResourceMinAmperage        Integer32,
2802    tmnxHwResourceMinAmperageTime    TimeStamp
2803}
2804
2805tmnxHwResourceCurrentVoltage     OBJECT-TYPE
2806    SYNTAX      Integer32
2807    MAX-ACCESS  read-only
2808    STATUS      current
2809    DESCRIPTION
2810        "The value of tmnxHwResourceCurrentVoltage indicates the current voltage
2811         use of the managed hardware component in 1/10000 of a Volt(V)."
2812    ::= { tmnxHwResourceEntry 1 }
2813
2814tmnxHwResourcePeakVoltage        OBJECT-TYPE
2815    SYNTAX      Integer32
2816    MAX-ACCESS  read-only
2817    STATUS      current
2818    DESCRIPTION
2819        "The value of tmnxHwResourcePeakVoltage indicates the peak voltage
2820         use of the managed hardware component in 1/10000 of a Volt(V) last
2821         recorded at the time indicated by tmnxHwResourcePeakVoltageTime."
2822    ::= { tmnxHwResourceEntry 2 }
2823
2824tmnxHwResourcePeakVoltageTime    OBJECT-TYPE
2825    SYNTAX      TimeStamp
2826    MAX-ACCESS  read-only
2827    STATUS      current
2828    DESCRIPTION
2829        "The value of tmnxHwResourcePeakVoltageTime indicates the time, since
2830         system initialization, that tmnxHwResourcePeakVoltage was last
2831         updated."
2832    ::= { tmnxHwResourceEntry 3 }
2833
2834tmnxHwResourceMinVoltage         OBJECT-TYPE
2835    SYNTAX      Integer32
2836    MAX-ACCESS  read-only
2837    STATUS      current
2838    DESCRIPTION
2839        "The value of tmnxHwResourceMinVoltage indicates the lowest voltage
2840         use of the managed hardware component in 1/10000 of a Volt(V) last
2841         recorded at the time indicated by tmnxHwResourceMinVoltageTime."
2842    ::= { tmnxHwResourceEntry 4 }
2843
2844tmnxHwResourceMinVoltageTime     OBJECT-TYPE
2845    SYNTAX      TimeStamp
2846    MAX-ACCESS  read-only
2847    STATUS      current
2848    DESCRIPTION
2849        "The value of tmnxHwResourceMinVoltageTime indicates the time, since
2850         system initialization, that tmnxHwResourceMinVoltage was last updated."
2851    ::= { tmnxHwResourceEntry 5 }
2852
2853tmnxHwResourceCurrentWattage     OBJECT-TYPE
2854    SYNTAX      Integer32
2855    MAX-ACCESS  read-only
2856    STATUS      current
2857    DESCRIPTION
2858        "The value of tmnxHwResourceCurrentWattage indicates the current power
2859         use of the managed hardware component in 1/10th of a micro-Watt (uW)."
2860    ::= { tmnxHwResourceEntry 6 }
2861
2862tmnxHwResourcePeakWattage        OBJECT-TYPE
2863    SYNTAX      Integer32
2864    MAX-ACCESS  read-only
2865    STATUS      current
2866    DESCRIPTION
2867        "The value of tmnxHwResourcePeakWattage indicates the peak power
2868         use of the managed hardware component in 1/10th of a micro-Watt (uW)
2869         last recorded at the time indicated by
2870         tmnxHwResourcePeakWattageTime."
2871    ::= { tmnxHwResourceEntry 7 }
2872
2873tmnxHwResourcePeakWattageTime    OBJECT-TYPE
2874    SYNTAX      TimeStamp
2875    MAX-ACCESS  read-only
2876    STATUS      current
2877    DESCRIPTION
2878        "The value of tmnxHwResourcePeakWattageTime indicates the time, since
2879         system initialization, that tmnxHwResourcePeakWattage was last
2880         updated."
2881    ::= { tmnxHwResourceEntry 8 }
2882
2883tmnxHwResourceMinWattage         OBJECT-TYPE
2884    SYNTAX      Integer32
2885    MAX-ACCESS  read-only
2886    STATUS      current
2887    DESCRIPTION
2888        "The value of tmnxHwResourceMinWattage indicates the lowest power
2889         use of the managed hardware component in 1/10th of a micro-Watt (uW)
2890         last recorded at the time indicated by tmnxHwResourceMinWattageTime."
2891    ::= { tmnxHwResourceEntry 9 }
2892
2893tmnxHwResourceMinWattageTime     OBJECT-TYPE
2894    SYNTAX      TimeStamp
2895    MAX-ACCESS  read-only
2896    STATUS      current
2897    DESCRIPTION
2898        "The value of tmnxHwResourceMinWattageTime indicates the time, since
2899        system initialization, that tmnxHwResourceMinWattage was last updated."
2900    ::= { tmnxHwResourceEntry 10 }
2901
2902tmnxHwResourceCurrentAmperage    OBJECT-TYPE
2903    SYNTAX      Integer32
2904    MAX-ACCESS  read-only
2905    STATUS      current
2906    DESCRIPTION
2907        "The value of tmnxHwResourceCurrentAmperage indicates the current
2908         drawn by the managed hardware component in micro-Amperes (uA)."
2909    ::= { tmnxHwResourceEntry 11 }
2910
2911tmnxHwResourcePeakAmperage       OBJECT-TYPE
2912    SYNTAX      Integer32
2913    MAX-ACCESS  read-only
2914    STATUS      current
2915    DESCRIPTION
2916        "The value of tmnxHwResourcePeakAmperage indicates the peak current
2917         drawn by the managed hardware component in micro-Amperes (uA) last
2918         recorded at the time indicated by tmnxHwResourcePeakAmperageTime."
2919    ::= { tmnxHwResourceEntry 12 }
2920
2921tmnxHwResourcePeakAmperageTime   OBJECT-TYPE
2922    SYNTAX      TimeStamp
2923    MAX-ACCESS  read-only
2924    STATUS      current
2925    DESCRIPTION
2926        "The value of tmnxHwResourcePeakAmperageTime indicates the time, since
2927         system initialization, that tmnxHwResourcePeakAmperage was last
2928         updated."
2929    ::= { tmnxHwResourceEntry 13 }
2930
2931tmnxHwResourceMinAmperage        OBJECT-TYPE
2932    SYNTAX      Integer32
2933    MAX-ACCESS  read-only
2934    STATUS      current
2935    DESCRIPTION
2936        "The value of tmnxHwResourceMinAmperage indicates the lowest current
2937         drawn by the managed hardware component in micro-Amperes (uA) last
2938         recorded at the time indicated by tmnxHwResourceMinAmperageTime."
2939    ::= { tmnxHwResourceEntry 14 }
2940
2941tmnxHwResourceMinAmperageTime    OBJECT-TYPE
2942    SYNTAX      TimeStamp
2943    MAX-ACCESS  read-only
2944    STATUS      current
2945    DESCRIPTION
2946        "The value of tmnxHwResourceMinAmperageTime indicates the time, since
2947        system initialization, that tmnxHwResourceMinAmperage was last updated."
2948    ::= { tmnxHwResourceEntry 15 }
2949
2950--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
2951--
2952--      Alcatel-Lucent SROS series Card Objects
2953--
2954
2955--
2956--      IOM Card Table - The tmnxCardTable contains information
2957--                       about the IOM cards in a chassis.
2958--
2959
2960tmnxCardLastChange   OBJECT-TYPE
2961    SYNTAX      TimeStamp
2962    MAX-ACCESS  read-only
2963    STATUS      current
2964    DESCRIPTION
2965         "The value of sysUpTime when the tmnxCardTable was last changed."
2966    ::= { tmnxCardObjs 1 }
2967
2968tmnxCardTable OBJECT-TYPE
2969    SYNTAX      SEQUENCE OF TmnxCardEntry
2970    MAX-ACCESS  not-accessible
2971    STATUS      current
2972    DESCRIPTION
2973        "The tmnxCardTable has an entry for each IOM card slot in each
2974         chassis in the TMNX system."
2975    ::= { tmnxCardObjs 2 }
2976
2977tmnxCardEntry       OBJECT-TYPE
2978    SYNTAX      TmnxCardEntry
2979    MAX-ACCESS  not-accessible
2980    STATUS      current
2981    DESCRIPTION
2982        "Each row entry represents an IOM card slot in a chassis in the
2983         system.  Entries cannot be created and deleted via SNMP SET
2984         operations.  When a tmnxChassisEntry is created, a tmnxCardEntry
2985         is created for each IOM card slot in that chassis.  Before a
2986         tmnxChassisEntry can be deleted, each tmnxCardEntry for that
2987         chassis must be in the proper state for removal."
2988    INDEX   { tmnxChassisIndex, tmnxCardSlotNum }
2989    ::= { tmnxCardTable 1 }
2990
2991TmnxCardEntry ::=
2992    SEQUENCE {
2993        tmnxCardSlotNum                     TmnxSlotNum,
2994        tmnxCardSupportedTypes              TmnxCardSuppType,
2995        tmnxCardAllowedTypes                TmnxCardType,
2996        tmnxCardAssignedType                TmnxCardType,
2997        tmnxCardEquippedType                TmnxCardType,
2998        tmnxCardHwIndex                     TmnxHwIndex,
2999        tmnxCardClockSource                 TItemDescription,
3000        tmnxCardNumMdaSlots                 Unsigned32,
3001        tmnxCardNumMdas                     Unsigned32,
3002        tmnxCardReboot                      TmnxCardRebootType,
3003        tmnxCardMemorySize                  Unsigned32,
3004        tmnxCardNamedPoolAdminMode          TmnxAdminState,
3005        tmnxCardNamedPoolOperMode           TmnxAdminState,
3006        tmnxCardSoftReset                   TmnxActionType,
3007        tmnxCardLastBootupReason            INTEGER,
3008        tmnxCardCmplx1IngrFcsOccur          Counter32,
3009        tmnxCardCmplx1IngrFcsOccurTime      TimeStamp,
3010        tmnxCardCmplx1EgrFcsOccur           Counter32,
3011        tmnxCardCmplx1EgrFcsOccurTime       TimeStamp,
3012        tmnxCardCmplx2IngrFcsOccur          Counter32,
3013        tmnxCardCmplx2IngrFcsOccurTime      TimeStamp,
3014        tmnxCardCmplx2EgrFcsOccur           Counter32,
3015        tmnxCardCmplx2EgrFcsOccurTime       TimeStamp,
3016        tmnxCardCmplx1MemParityOccur        Counter32,
3017        tmnxCardCmplx1MemParityOccurTime    TimeStamp,
3018        tmnxCardCmplx2MemParityOccur        Counter32,
3019        tmnxCardCmplx2MemParityOccurTime    TimeStamp,
3020        tmnxCardCapability                  BITS,
3021        tmnxCardCmplx1CAMErrorOccur         Counter32,
3022        tmnxCardCmplx1CAMErrorOccurTime     TimeStamp,
3023        tmnxCardCmplx2CAMErrorOccur         Counter32,
3024        tmnxCardCmplx2CAMErrorOccurTime     TimeStamp,
3025        tmnxCardFailOnError                 BITS,
3026        tmnxCardCmplx1EgrFcsSrcSlots        TmnxCardSlotBitMap,
3027        tmnxCardCmplx2EgrFcsSrcSlots        TmnxCardSlotBitMap,
3028        tmnxCardHardResetUnsupMdas          TruthValue
3029    }
3030
3031tmnxCardSlotNum     OBJECT-TYPE
3032    SYNTAX      TmnxSlotNum
3033    MAX-ACCESS  not-accessible
3034    STATUS      current
3035    DESCRIPTION
3036        "The unique value which identifies this IOM slot within a chassis
3037         in the system."
3038    ::= { tmnxCardEntry 1 }
3039
3040tmnxCardSupportedTypes  OBJECT-TYPE
3041    SYNTAX      TmnxCardSuppType
3042    MAX-ACCESS  read-only
3043    STATUS      current
3044    DESCRIPTION
3045        "A bit-mask that specifies what card types can be physically
3046         supported in this IOM slot in this chassis."
3047    ::= { tmnxCardEntry 2 }
3048
3049tmnxCardAllowedTypes    OBJECT-TYPE
3050    SYNTAX      TmnxCardType
3051    MAX-ACCESS  read-write
3052    STATUS      obsolete
3053    DESCRIPTION
3054        "A bit-mask that specifies what IOM card types the administrator
3055         has designated be allowed to be inserted into this slot.
3056         If the slot has not-been pre-provisioned and a card that
3057         does not match one of the allowed types is inserted into
3058         this slot, a mis-match alarm will be raised.  If a specific
3059         value has not yet been SET by the manager, tmnxCardAllowedTypes
3060         will return the same value to a GET request as
3061         tmnxCardSupportedTypes.
3062
3063         The object was made obsolete in the 3.0 release."
3064    ::= { tmnxCardEntry 3 }
3065
3066tmnxCardAssignedType        OBJECT-TYPE
3067    SYNTAX      TmnxCardType
3068    MAX-ACCESS  read-write
3069    STATUS      current
3070    DESCRIPTION
3071        "The tmnxCardAssignedType specifies the administratively assigned
3072         (pre-provisioned) IOM card type defined in the tmnxCardTypeTable that
3073         should occupy this slot in this chassis.  If tmnxCardAssignedType has
3074         a value of 1 (unassigned), this slot has not yet been pre-provisioned."
3075    DEFVAL { 1 }
3076    ::= { tmnxCardEntry 4 }
3077
3078tmnxCardEquippedType        OBJECT-TYPE
3079    SYNTAX      TmnxCardType
3080    MAX-ACCESS  read-only
3081    STATUS      current
3082    DESCRIPTION
3083        "The tmnxCardEquippedType indicates the IOM card type that is physically
3084         inserted into this slot in this chassis.  If the slot has been
3085         pre-provisioned, tmnxCardAssignedType is not equal to 1 (unassigned),
3086         and the value of tmnxCardEquippedType is not the same as
3087         tmnxCardAssignedType, a mis-match alarm will be raised.
3088
3089         A value of 0 indicates the IOM card type is not recognized by the
3090         software."
3091    ::= { tmnxCardEntry 5 }
3092
3093tmnxCardHwIndex      OBJECT-TYPE
3094    SYNTAX      TmnxHwIndex
3095    MAX-ACCESS  read-only
3096    STATUS      current
3097    DESCRIPTION
3098        "The value of tmnxCardHwIndex is the index into the tmnxHwTable
3099         for the row entry that represents the hardware component information
3100         for this IOM card."
3101    ::= { tmnxCardEntry 6 }
3102
3103tmnxCardClockSource OBJECT-TYPE
3104    SYNTAX      TItemDescription
3105    MAX-ACCESS  read-only
3106    STATUS      current
3107    DESCRIPTION
3108        "The clock source used by the IOM card in this slot."
3109     ::= { tmnxCardEntry 10 }
3110
3111tmnxCardNumMdaSlots             OBJECT-TYPE
3112    SYNTAX          Unsigned32
3113    MAX-ACCESS      read-only
3114    STATUS          current
3115    DESCRIPTION
3116        "The number of Media Dependent Adapter (MDA) slots available on
3117         this IOM card."
3118    ::= { tmnxCardEntry 11 }
3119
3120tmnxCardNumMdas     OBJECT-TYPE
3121    SYNTAX      Unsigned32
3122    MAX-ACCESS  read-only
3123    STATUS      current
3124    DESCRIPTION
3125        "The number of Media Dependent Adapters installed on this IOM card."
3126    ::= { tmnxCardEntry 12 }
3127
3128tmnxCardReboot      OBJECT-TYPE
3129    SYNTAX      TmnxCardRebootType
3130    MAX-ACCESS  read-write
3131    STATUS      current
3132    DESCRIPTION
3133        "Setting this variable to 'cardReboot' causes the IOM card to execute
3134         a soft-reboot. Setting this variable to 'cardPowerCycle' causes the
3135         IOM to turn off and turn on power to the card initiating a
3136         hard-reboot."
3137    DEFVAL { notApplicable }
3138    ::= { tmnxCardEntry 13 }
3139
3140tmnxCardMemorySize   OBJECT-TYPE
3141    SYNTAX      Unsigned32
3142    UNITS       "Mega-bytes"
3143    MAX-ACCESS  read-only
3144    STATUS      current
3145    DESCRIPTION
3146        "The value of tmnxCardMemorySize indicates the amount of
3147         memory, in mega-bytes, populated on this IOM card."
3148    ::= { tmnxCardEntry 14 }
3149
3150tmnxCardNamedPoolAdminMode OBJECT-TYPE
3151    SYNTAX      TmnxAdminState
3152    MAX-ACCESS  read-write
3153    STATUS      current
3154    DESCRIPTION
3155        "The value of tmnxCardNamedPoolAdminMode indicates whether or
3156         not an IOM is provisioned for the configuration of named pools. If
3157         the value of tmnxCardNamedPoolAdminMode is 'inService(2)', the
3158         system will change the way default pools are created and allow for
3159         the creation of MDA and port level named buffer pools. If the value
3160         of tmnxCardNamedPoolAdminMode is 'outOfService(3)', the system will
3161         not create per port pools, instead a default network and access pool
3162         is created for ingress and egress and is shared by queues on all
3163         ports. This object is used in conjunction with
3164         tmnxCardNamedPoolOperMode."
3165    DEFVAL  { outOfService }
3166    ::= { tmnxCardEntry 15 }
3167
3168tmnxCardNamedPoolOperMode OBJECT-TYPE
3169    SYNTAX      TmnxAdminState
3170    MAX-ACCESS  read-only
3171    STATUS      current
3172    DESCRIPTION
3173        "The value of tmnxCardNamedPoolOperMode indicates whether or
3174         not an IOM provisioned with tmnxCardNamedPoolAdminMode to a
3175         value of 'inService(2)' will activly use named pools or not.
3176         A value of 'outOfService(3) means that the named pool configurations
3177         will not be downloaded to the IOM until after a reset of the IOM
3178         is performed. A value of 'inService(2)' means that the named pool
3179         configurations are programmed by the IOM. On systems using a
3180         separate CPM and IOM combination the value of tmnxCardNamedPoolOperMode
3181         and tmnxCardNamedPoolAdminMode will always be in sync due to a
3182         mandatory reboot of the IOM. On systems using a combined image (CFM)
3183         these values will be out-of-sync until the chassis is rebooted."
3184    DEFVAL  { outOfService }
3185    ::= { tmnxCardEntry 16 }
3186
3187tmnxCardSoftReset OBJECT-TYPE
3188    SYNTAX      TmnxActionType
3189    MAX-ACCESS  read-write
3190    STATUS      current
3191    DESCRIPTION
3192        "The value of tmnxCardSoftReset, when set to 'doAction(1)', causes the
3193         IOM card to re-initialize the applications and protocols running on the
3194         card with limited traffic impact."
3195    DEFVAL  { notApplicable }
3196    ::= { tmnxCardEntry 17 }
3197
3198tmnxCardLastBootupReason OBJECT-TYPE
3199    SYNTAX     INTEGER {
3200                     hardReboot     (0),
3201                     softReset      (1),
3202                     powerCycle     (2),
3203                     clearCard      (3),
3204                     activitySwitch (4),
3205                     configChange   (5),
3206                     runtimeFail    (6),
3207                     bootFail       (7),
3208                     unexpected     (8),
3209                     issuTimeout    (9),
3210                     reinserted     (10),
3211                     issuHardReboot (11),
3212                     ccmFail        (12)
3213               }
3214    MAX-ACCESS read-only
3215    STATUS     current
3216    DESCRIPTION
3217        "The value of tmnxCardLastBootupReason indicates the type of the last
3218         reboot/reset of the IOM card.
3219
3220         Not all reasons exist in all software versions.
3221
3222         hardReboot     - new/different card inserted for first time
3223         softReset      - user initiated soft reset
3224         powerCycle     - user initiated power cycle
3225         clearCard      - user initiated clear card
3226         activitySwitch - card rebooted during activity switch
3227         configChange   - configuration change forced a reboot
3228         runtimeFail    - card failed while running and was rebooted
3229         bootFail       - card failed during boot and was rebooted
3230         unexpected     - card unexpectedly rebooted
3231         issuTimeout    - ISSU timeout timer expired
3232         reinserted     - card was removed and reinserted
3233         issuHardReboot - card rebooted during ISSU upgrade
3234                             (soft reset ineligible)
3235         ccmFail        - Chassis Control Module (CCM) failed.
3236         "
3237    ::= {tmnxCardEntry 18 }
3238
3239tmnxCardCmplx1IngrFcsOccur       OBJECT-TYPE
3240    SYNTAX      Counter32
3241    MAX-ACCESS  read-only
3242    STATUS      current
3243    DESCRIPTION
3244        "The value of tmnxCardCmplx1IngrFcsOccur indicates the
3245         number of times the first complex experienced an
3246         occurrence of a FCS error in the ingress direction since
3247         startup, last clear, or IOM reboot."
3248   ::= { tmnxCardEntry 19 }
3249
3250tmnxCardCmplx1IngrFcsOccurTime   OBJECT-TYPE
3251    SYNTAX      TimeStamp
3252    MAX-ACCESS  read-only
3253    STATUS      current
3254    DESCRIPTION
3255        "The value of tmnxCardCmplx1IngrFcsOccurTime indicates the
3256         last time tmnxCardCmplx1IngrFcsOccur incremented."
3257   ::= { tmnxCardEntry 20 }
3258
3259tmnxCardCmplx1EgrFcsOccur        OBJECT-TYPE
3260    SYNTAX      Counter32
3261    MAX-ACCESS  read-only
3262    STATUS      current
3263    DESCRIPTION
3264        "The value of tmnxCardCmplx1EgrFcsOccur indicates the
3265         number of times the first complex experienced an
3266         occurrence of a FCS error in the egress direction since
3267         startup, last clear, or IOM reboot."
3268   ::= { tmnxCardEntry 21 }
3269
3270tmnxCardCmplx1EgrFcsOccurTime    OBJECT-TYPE
3271    SYNTAX      TimeStamp
3272    MAX-ACCESS  read-only
3273    STATUS      current
3274    DESCRIPTION
3275        "The value of tmnxCardCmplx1EgrFcsOccurTime indicates the
3276         last time tmnxCardCmplx1EgrFcsOccur incremented."
3277   ::= { tmnxCardEntry 22 }
3278
3279tmnxCardCmplx2IngrFcsOccur          OBJECT-TYPE
3280    SYNTAX      Counter32
3281    MAX-ACCESS  read-only
3282    STATUS      current
3283    DESCRIPTION
3284        "The value of tmnxCardCmplx2IngrFcsOccur indicates the
3285         number of times the second complex experienced an
3286         occurrence of a FCS error in the ingress direction since
3287         startup, last clear, or IOM reboot."
3288   ::= { tmnxCardEntry 23 }
3289
3290tmnxCardCmplx2IngrFcsOccurTime      OBJECT-TYPE
3291    SYNTAX      TimeStamp
3292    MAX-ACCESS  read-only
3293    STATUS      current
3294    DESCRIPTION
3295        "The value of tmnxCardCmplx2IngrFcsOccurTime indicates the
3296         last time tmnxCardCmplx2IngrFcsOccur incremented."
3297   ::= { tmnxCardEntry 24 }
3298
3299tmnxCardCmplx2EgrFcsOccur           OBJECT-TYPE
3300    SYNTAX      Counter32
3301    MAX-ACCESS  read-only
3302    STATUS      current
3303    DESCRIPTION
3304        "The value of tmnxCardCmplx2EgrFcsOccur indicates the
3305         number of times the second complex experienced an
3306         occurrence of a FCS error in the egress direction since
3307         startup, last clear, or IOM reboot."
3308   ::= { tmnxCardEntry 25 }
3309
3310tmnxCardCmplx2EgrFcsOccurTime       OBJECT-TYPE
3311    SYNTAX      TimeStamp
3312    MAX-ACCESS  read-only
3313    STATUS      current
3314    DESCRIPTION
3315        "The value of tmnxCardCmplx2EgrFcsOccurTime indicates the
3316         last time tmnxCardCmplx2EgrFcsOccur incremented."
3317   ::= { tmnxCardEntry 26 }
3318
3319tmnxCardCmplx1MemParityOccur     OBJECT-TYPE
3320    SYNTAX      Counter32
3321    MAX-ACCESS  read-only
3322    STATUS      current
3323    DESCRIPTION
3324        "The value of tmnxCardCmplx1MemParityOccur indicates the
3325         number of times the first complex experienced an
3326         occurrence of a memory parity error since startup,
3327         last clear, or IOM reboot."
3328   ::= { tmnxCardEntry 27 }
3329
3330tmnxCardCmplx1MemParityOccurTime OBJECT-TYPE
3331    SYNTAX      TimeStamp
3332    MAX-ACCESS  read-only
3333    STATUS      current
3334    DESCRIPTION
3335        "The value of tmnxCardCmplx1MemParityOccurTime indicates the
3336         last time tmnxCardCmplx1MemParityOccur incremented."
3337   ::= { tmnxCardEntry 28 }
3338
3339tmnxCardCmplx2MemParityOccur     OBJECT-TYPE
3340    SYNTAX      Counter32
3341    MAX-ACCESS  read-only
3342    STATUS      current
3343    DESCRIPTION
3344        "The value of tmnxCardCmplx2MemParityOccur indicates the
3345         number of times the second complex experienced an
3346         occurrence of a memory parity error since startup,
3347         last clear, or IOM reboot."
3348   ::= { tmnxCardEntry 29 }
3349
3350tmnxCardCmplx2MemParityOccurTime OBJECT-TYPE
3351    SYNTAX      TimeStamp
3352    MAX-ACCESS  read-only
3353    STATUS      current
3354    DESCRIPTION
3355        "The value of tmnxCardCmplx2MemParityOccurTime indicates the
3356         last time tmnxCardCmplx2MemParityOccur incremented."
3357   ::= { tmnxCardEntry 30 }
3358
3359tmnxCardCapability OBJECT-TYPE
3360    SYNTAX   BITS {
3361                 sr (0) -- numbering must start at zero.
3362             }
3363    MAX-ACCESS  read-write
3364    STATUS      current
3365    DESCRIPTION
3366        "The value of tmnxCardCapability indicates special capabilities
3367         that are set on this card.
3368
3369         tmnxCardCapability is a bitmap whith the following values:
3370            'sr': Enable SR capabilities on this card.
3371        "
3372   ::= { tmnxCardEntry 31 }
3373
3374tmnxCardCmplx1CAMErrorOccur      OBJECT-TYPE
3375    SYNTAX      Counter32
3376    MAX-ACCESS  read-only
3377    STATUS      current
3378    DESCRIPTION
3379        "The value of tmnxCardCmplx1CAMErrorOccur indicates the
3380         number of times the first complex experienced an
3381         occurrence of a CAM error since startup, last clear, or IOM reboot."
3382   ::= { tmnxCardEntry 32 }
3383
3384tmnxCardCmplx1CAMErrorOccurTime  OBJECT-TYPE
3385    SYNTAX      TimeStamp
3386    MAX-ACCESS  read-only
3387    STATUS      current
3388    DESCRIPTION
3389        "The value of tmnxCardCmplx1CAMErrorOccurTime indicates the
3390         last time tmnxCardCmplx1CAMErrorOccur incremented."
3391   ::= { tmnxCardEntry 33 }
3392
3393tmnxCardCmplx2CAMErrorOccur      OBJECT-TYPE
3394    SYNTAX      Counter32
3395    MAX-ACCESS  read-only
3396    STATUS      current
3397    DESCRIPTION
3398        "The value of tmnxCardCmplx2CAMErrorOccur indicates the
3399         number of times the second complex experienced an
3400         occurrence of a CAM error since startup, last clear, or IOM reboot."
3401   ::= { tmnxCardEntry 34 }
3402
3403tmnxCardCmplx2CAMErrorOccurTime  OBJECT-TYPE
3404    SYNTAX      TimeStamp
3405    MAX-ACCESS  read-only
3406    STATUS      current
3407    DESCRIPTION
3408        "The value of tmnxCardCmplx2CAMErrorOccurTime indicates the
3409         last time tmnxCardCmplx2CAMErrorOccur incremented."
3410   ::= { tmnxCardEntry 35 }
3411
3412tmnxCardFailOnError              OBJECT-TYPE
3413   SYNTAX       BITS {
3414                   memoryEventGroupA (0)
3415                }
3416   MAX-ACCESS   read-write
3417   STATUS       current
3418   DESCRIPTION
3419       "The value of tmnxCardFailOnError specifies the set of events that, if
3420        triggered, will cause the card to fail. The suppression or generation
3421        of the NOTIFICATION-TYPE event is independent of the card failing.
3422
3423        The following set of events are configurable:
3424             memoryEventGroupA (0) - tmnxEqCardPChipMemoryEvent,
3425                                     tmnxEqCardPChipCamEvent,
3426                                     tmnxEqCardPChipError.
3427
3428        tmnxEqCardPChipError will only cause a card failure if all MDAs(s)
3429        on the complex are Ethernet or ISAs."
3430   DEFVAL { {} }
3431   ::= { tmnxCardEntry 36 }
3432
3433tmnxCardCmplx1EgrFcsSrcSlots     OBJECT-TYPE
3434    SYNTAX      TmnxCardSlotBitMap
3435    MAX-ACCESS  read-only
3436    STATUS      current
3437    DESCRIPTION
3438        "The value of tmnxCardCmplx1EgrFcsSrcSlots indicates the source slots
3439        reported from the last time tmnxCardCmplx1EgrFcsOccur incremented."
3440    ::= { tmnxCardEntry 37 }
3441
3442tmnxCardCmplx2EgrFcsSrcSlots     OBJECT-TYPE
3443    SYNTAX      TmnxCardSlotBitMap
3444    MAX-ACCESS  read-only
3445    STATUS      current
3446    DESCRIPTION
3447        "The value of tmnxCardCmplx2EgrFcsSrcSlots indicates the source slots
3448        reported from the last time tmnxCardCmplx2EgrFcsOccur incremented."
3449    ::= { tmnxCardEntry 38 }
3450
3451tmnxCardHardResetUnsupMdas       OBJECT-TYPE
3452    SYNTAX      TruthValue
3453    MAX-ACCESS  read-write
3454    STATUS      current
3455    DESCRIPTION
3456        "The value of tmnxCardHardResetUnsupMdas specifies whether to do hard
3457        reset of the soft reset incapable MDAs as part setting 'doAction' to
3458        tmnxCardSoftReset object."
3459    DEFVAL { false }
3460    ::= { tmnxCardEntry 39 }
3461
3462--
3463--      CPM Card Table - The Chassis Process Manager card table contains
3464--      the information about CPM cards or modules in a chassis.
3465--
3466
3467tmnxCpmCardLastChange   OBJECT-TYPE
3468    SYNTAX      TimeStamp
3469    MAX-ACCESS  read-only
3470    STATUS      current
3471    DESCRIPTION
3472        "The value of sysUpTime when the tmnxCpmCardTable was last changed."
3473    ::= { tmnxCardObjs 3 }
3474
3475tmnxCpmCardTable    OBJECT-TYPE
3476    SYNTAX  SEQUENCE OF TmnxCpmCardEntry
3477    MAX-ACCESS  not-accessible
3478    STATUS      current
3479    DESCRIPTION
3480        "The tmnxCpmCardTable has an entry for each CPM card or module in
3481         each chassis in the TMNX system."
3482    ::= { tmnxCardObjs 4 }
3483
3484tmnxCpmCardEntry       OBJECT-TYPE
3485    SYNTAX      TmnxCpmCardEntry
3486    MAX-ACCESS  not-accessible
3487    STATUS      current
3488    DESCRIPTION
3489        "Each row entry represents a CPM card or module in a chassis in the
3490         system.  Entries cannot be created and deleted via SNMP SET
3491         operations.  When a tmnxChassisEntry is created, a tmnxCpmCardEntry
3492         is created for each CPM card or module in that chassis.  Before a
3493         tmnxChassisEntry can be deleted, each tmnxCpmCardEntry for that
3494         chassis must be in the proper state for removal."
3495    INDEX   { tmnxChassisIndex, tmnxCpmCardSlotNum, tmnxCpmCardNum }
3496    ::= { tmnxCpmCardTable 1 }
3497
3498TmnxCpmCardEntry ::=
3499    SEQUENCE {
3500        tmnxCpmCardSlotNum                        TmnxSlotNum,
3501        tmnxCpmCardNum                            Unsigned32,
3502        tmnxCpmCardSupportedTypes                 TmnxCardSuppType,
3503        tmnxCpmCardAllowedTypes                   TmnxCardType,
3504        tmnxCpmCardAssignedType                   TmnxCardType,
3505        tmnxCpmCardEquippedType                   TmnxCardType,
3506        tmnxCpmCardHwIndex                        TmnxHwIndex,
3507        tmnxCpmCardBootOptionVersion              TItemDescription,
3508        tmnxCpmCardBootOptionLastModified         DateAndTime,
3509        tmnxCpmCardConfigBootedVersion            TItemDescription,
3510        tmnxCpmCardIndexBootedVersion             TItemDescription,
3511        tmnxCpmCardConfigLastModified             DateAndTime,
3512        tmnxCpmCardConfigLastSaved                DateAndTime,
3513        tmnxCpmCardRedundant                      INTEGER,
3514        tmnxCpmCardClockSource                    TItemDescription,
3515        tmnxCpmCardNumCpus                        Unsigned32,
3516        tmnxCpmCardCpuType                        INTEGER,
3517        tmnxCpmCardMemorySize                     Unsigned32,
3518        tmnxCpmCardSwitchToRedundantCard          TmnxActionType,
3519        tmnxCpmCardReboot                         TmnxActionType,
3520        tmnxCpmCardRereadBootOptions              TmnxActionType,
3521        tmnxCpmCardConfigFileLastBooted           DisplayString,
3522        tmnxCpmCardConfigFileLastSaved            DisplayString,
3523        tmnxCpmCardConfigFileLastBootedHeader     OCTET STRING,
3524        tmnxCpmCardIndexFileLastBootedHeader      OCTET STRING,
3525        tmnxCpmCardBootOptionSource               DisplayString,
3526        tmnxCpmCardConfigSource                   INTEGER,
3527        tmnxCpmCardBootOptionLastSaved            DateAndTime,
3528        tmnxCpmCardMasterSlaveRefState            INTEGER,
3529        tmnxCpmCardConfigUserLastModified         SnmpAdminString,
3530        tmnxCpmCardCmplxCAMErrOccur               Counter32,
3531        tmnxCpmCardCmplxCAMErrOccurTime           TimeStamp,
3532        tmnxCpmCardOscillatorType                 INTEGER
3533    }
3534
3535tmnxCpmCardSlotNum     OBJECT-TYPE
3536    SYNTAX      TmnxSlotNum
3537    MAX-ACCESS  not-accessible
3538    STATUS      current
3539    DESCRIPTION
3540        "The unique value which identifies this slot within a chassis in
3541         the system.  Depending upon the value of tmnxChassisType, this may
3542         represent a fabric slot or a regular card slot.  If this CPM module
3543         resides on a fabric card, tmnxCpmCardSlotNum has the value the
3544         corresponding tmnxFabricSlotNum.  If this is a CPM module on a
3545         fabric card, tmnxCpmCardSlotNum is the fabric slot number in the
3546         chassis where this CPM module is located.  Else if this is a
3547         CPM card, tmnxCpmCardSlotNum is a regular card slot number."
3548    ::= { tmnxCpmCardEntry 1 }
3549
3550tmnxCpmCardNum      OBJECT-TYPE
3551    SYNTAX      Unsigned32
3552    MAX-ACCESS  not-accessible
3553    STATUS      current
3554    DESCRIPTION
3555        "The unique value which identifies this CPM module within a
3556         specific card slot within a chassis in the system."
3557    ::= { tmnxCpmCardEntry 2 }
3558
3559tmnxCpmCardSupportedTypes  OBJECT-TYPE
3560    SYNTAX      TmnxCardSuppType
3561    MAX-ACCESS  read-only
3562    STATUS      current
3563    DESCRIPTION
3564        "A bit-mask that specifies what CPM card types can be physically
3565         supported in this slot in this chassis."
3566    ::= { tmnxCpmCardEntry 3 }
3567
3568tmnxCpmCardAllowedTypes    OBJECT-TYPE
3569    SYNTAX      TmnxCardType
3570    MAX-ACCESS  read-write
3571    STATUS      obsolete
3572    DESCRIPTION
3573        "A bit-mask that specifies what CPM card types the administrator
3574         has designated be allowed to be inserted into this slot.  If the
3575         slot has not-been pre-provisioned and a card that does not match
3576         one of the allowed types is inserted into this slot, a mis-match
3577         alarm will be raised.  If a specific value has not yet been SET by
3578         the manager, tmnxCpmCardAllowedTypes will return the same value to
3579         a GET request as tmnxCpmCardSupportedTypes.
3580
3581         The object was made obsolete in the 3.0 release."
3582    ::= { tmnxCpmCardEntry 4 }
3583
3584tmnxCpmCardAssignedType        OBJECT-TYPE
3585    SYNTAX      TmnxCardType
3586    MAX-ACCESS  read-write
3587    STATUS      current
3588    DESCRIPTION
3589        "The tmnxCpmCardAssignedType specifies the administratively assigned
3590         (pre-provisioned) CPM card type defined in tmnxCardTypeTable that
3591         should occupy this slot in this chassis.  If tmnxCpmCardAssignedType
3592         has a value of 1 (unassigned), this slot has not yet been
3593         pre-provisioned."
3594    DEFVAL { 1 }
3595    ::= { tmnxCpmCardEntry 5 }
3596
3597tmnxCpmCardEquippedType        OBJECT-TYPE
3598    SYNTAX      TmnxCardType
3599    MAX-ACCESS  read-only
3600    STATUS      current
3601     DESCRIPTION
3602        "The tmnxCpmCardEquippedType indicates the CPM card type that is
3603         physically inserted into this slot in this chassis.  If the slot has
3604         been pre-provisioned, tmnxCpmCardAssignedType is not equal to 1
3605         (unassigned), and the value of tmnxCpmCardEquippedType is not the same
3606         as tmnxCpmCardAssignedType, a mis-match alarm will be raised."
3607    ::= { tmnxCpmCardEntry 6 }
3608
3609tmnxCpmCardHwIndex       OBJECT-TYPE
3610    SYNTAX      TmnxHwIndex
3611    MAX-ACCESS  read-only
3612    STATUS      current
3613    DESCRIPTION
3614        "The value of tmnxCpmCardHwIndex is the index into the tmnxHwTable
3615         for the row entry that represents the hardware component information
3616         for this CPM card or module."
3617    ::= { tmnxCpmCardEntry 7 }
3618
3619tmnxCpmCardBootOptionVersion     OBJECT-TYPE
3620    SYNTAX      TItemDescription
3621    MAX-ACCESS  read-only
3622    STATUS      current
3623    DESCRIPTION
3624        "The version number of boot option file (BOF) read by the CPM card in
3625         this slot."
3626    ::= { tmnxCpmCardEntry 8 }
3627
3628tmnxCpmCardBootOptionLastModified  OBJECT-TYPE
3629    SYNTAX      DateAndTime
3630    MAX-ACCESS  read-only
3631    STATUS      current
3632    DESCRIPTION
3633        "The date and time the boot options file (BOF) for this card was last
3634         modified.  If tmnxCpmCardBootOptionLastModified is more recent than
3635         tmnxHwSwLastBoot, the boot options file has been edited since
3636         the software was booted and different software images or configuration
3637         will likely be used when this card is next rebooted."
3638    ::= { tmnxCpmCardEntry 9 }
3639
3640tmnxCpmCardConfigBootedVersion OBJECT-TYPE
3641    SYNTAX      TItemDescription
3642    MAX-ACCESS  read-only
3643    STATUS      current
3644    DESCRIPTION
3645        "The version of the configuration file read when this CPM card was
3646         last rebooted."
3647    ::= { tmnxCpmCardEntry 10 }
3648
3649tmnxCpmCardIndexBootedVersion OBJECT-TYPE
3650    SYNTAX      TItemDescription
3651    MAX-ACCESS  read-only
3652    STATUS      current
3653    DESCRIPTION
3654        "The version of the index file read when this CPM card was
3655         last rebooted."
3656    ::= { tmnxCpmCardEntry 11 }
3657
3658tmnxCpmCardConfigLastModified  OBJECT-TYPE
3659    SYNTAX      DateAndTime
3660    MAX-ACCESS  read-only
3661    STATUS      current
3662    DESCRIPTION
3663        "The date and time the running configuration was last modified.
3664         If tmnxCpmCardConfigLastModified is more recent than
3665         tmnxHwSwLastBoot, the current configuration may be different
3666         than that in the configuration file read upon system initialization."
3667    ::= { tmnxCpmCardEntry 12 }
3668
3669tmnxCpmCardConfigLastSaved OBJECT-TYPE
3670    SYNTAX      DateAndTime
3671    MAX-ACCESS  read-only
3672    STATUS      current
3673    DESCRIPTION
3674        "The date and time the current configuration was last saved.
3675         If tmnxCpmCardConfigLastSaved is more recent the value of
3676         tmnxHwSwLastBoot, the initial configuration is likely to
3677         be different the next time the system is rebooted."
3678    ::= { tmnxCpmCardEntry 13 }
3679
3680tmnxCpmCardRedundant   OBJECT-TYPE
3681    SYNTAX      INTEGER {
3682                    singleton (1),
3683                    redundantActive (2),
3684                    redundantStandby (3),
3685                    redundantSplit (4),
3686                    redundantDisabled (5),
3687                    redundantSyncing (6)
3688                }
3689    MAX-ACCESS  read-only
3690    STATUS      current
3691    DESCRIPTION
3692        "This variable indicates if the CPM card is standalone or part
3693         of a pair of redundant cards.  If 'redundantDisabled',
3694         tmnxHwOperState indicates the specific reason why this
3695         redundant CPM card is not available.
3696
3697         Note that the 'redudantSplit' option is not implemented."
3698    ::= { tmnxCpmCardEntry 14 }
3699
3700tmnxCpmCardClockSource OBJECT-TYPE
3701    SYNTAX      TItemDescription
3702    MAX-ACCESS  read-only
3703    STATUS      current
3704    DESCRIPTION
3705        "The clock source used by the CPM card in this slot."
3706    ::= { tmnxCpmCardEntry 15 }
3707
3708tmnxCpmCardNumCpus      OBJECT-TYPE
3709    SYNTAX      Unsigned32
3710    MAX-ACCESS  read-only
3711    STATUS      current
3712    DESCRIPTION
3713        "The value of tmnxCpmCardNumCpus indicates the number of CPU chips
3714         populated on this CPM module."
3715    ::= { tmnxCpmCardEntry 16 }
3716
3717tmnxCpmCardCpuType      OBJECT-TYPE
3718    SYNTAX      INTEGER {
3719                    unknown (1),
3720                    mips (2),
3721                    pentium-pc (3)
3722                }
3723    MAX-ACCESS  read-only
3724    STATUS      current
3725    DESCRIPTION
3726        "The value of tmnxCpmCardCpuType indicates the type of CPU chips
3727         populated on this CPM module."
3728    ::= { tmnxCpmCardEntry 17 }
3729
3730tmnxCpmCardMemorySize   OBJECT-TYPE
3731    SYNTAX      Unsigned32
3732    UNITS       "Mega-bytes"
3733    MAX-ACCESS  read-only
3734        STATUS          current
3735    DESCRIPTION
3736        "The value of tmnxCpmCardMemorySize indicates the amount of
3737         memory, in mega-bytes, populated on this CPM module."
3738    ::= { tmnxCpmCardEntry 18 }
3739
3740tmnxCpmCardSwitchToRedundantCard   OBJECT-TYPE
3741    SYNTAX      TmnxActionType
3742    MAX-ACCESS  read-write
3743    STATUS      current
3744    DESCRIPTION
3745        "Setting this variable to doAction causes the switchover to the
3746         redundant CPM card."
3747    DEFVAL { notApplicable }
3748    ::= { tmnxCpmCardEntry 19 }
3749
3750tmnxCpmCardReboot      OBJECT-TYPE
3751    SYNTAX      TmnxActionType
3752    MAX-ACCESS  read-write
3753    STATUS      current
3754    DESCRIPTION
3755        "Setting this variable to 'doAction' causes the CPM card to execute
3756         a soft-reboot."
3757    DEFVAL { notApplicable }
3758    ::= { tmnxCpmCardEntry 20 }
3759
3760tmnxCpmCardRereadBootOptions    OBJECT-TYPE
3761    SYNTAX      TmnxActionType
3762    MAX-ACCESS  read-write
3763    STATUS      current
3764    DESCRIPTION
3765        "Setting this variable to 'doAction' causes the Boot Options File
3766         (BOF) to be reread and applied."
3767    DEFVAL { notApplicable }
3768    ::= { tmnxCpmCardEntry 21 }
3769
3770tmnxCpmCardConfigFileLastBooted      OBJECT-TYPE
3771    SYNTAX      DisplayString
3772    MAX-ACCESS  read-only
3773    STATUS      current
3774    DESCRIPTION
3775        "tmnxCpmCardConfigFileLastBooted indicates the location and name of
3776         the configuration file from which the system last rebooted."
3777    ::= { tmnxCpmCardEntry 22 }
3778
3779tmnxCpmCardConfigFileLastSaved      OBJECT-TYPE
3780    SYNTAX      DisplayString
3781    MAX-ACCESS  read-only
3782    STATUS      current
3783    DESCRIPTION
3784        "tmnxCpmCardConfigFileLastSaved indicates the location and name of the
3785         file to which the configuration was last saved."
3786    ::= { tmnxCpmCardEntry 23 }
3787
3788tmnxCpmCardConfigFileLastBootedHeader       OBJECT-TYPE
3789    SYNTAX      OCTET STRING (SIZE (0..512))
3790    MAX-ACCESS  read-only
3791    STATUS      current
3792    DESCRIPTION
3793        "tmnxCpmCardConfigFileLastBootedHeader contains the header
3794         of the configuration file from which the system last rebooted."
3795    ::= { tmnxCpmCardEntry 24 }
3796
3797tmnxCpmCardIndexFileLastBootedHeader       OBJECT-TYPE
3798    SYNTAX      OCTET STRING (SIZE (0..512))
3799    MAX-ACCESS  read-only
3800    STATUS      current
3801    DESCRIPTION
3802        "tmnxCpmCardIndexFileLastBootedHeader contains the header
3803         of the index file from which the system last rebooted."
3804    ::= { tmnxCpmCardEntry 25 }
3805
3806tmnxCpmCardBootOptionSource       OBJECT-TYPE
3807    SYNTAX      DisplayString
3808    MAX-ACCESS  read-only
3809    STATUS      current
3810    DESCRIPTION
3811        "tmnxCpmCardBootOptionSource indicates the compact flash slot where the
3812         Boot Options File (BOF) file was found when the system last rebooted.
3813         For example, if the BOF file was found on compact flash slot 1, the
3814         value of this variable will be 'cf1:'"
3815    ::= { tmnxCpmCardEntry 26 }
3816
3817tmnxCpmCardConfigSource       OBJECT-TYPE
3818    SYNTAX      INTEGER {
3819                    unknown (0),
3820                    primary (1),
3821                    secondary (2),
3822                    tertiary (3)
3823                }
3824    MAX-ACCESS  read-only
3825    STATUS      current
3826    DESCRIPTION
3827        "The value of tmnxCpmCardConfigSource indicates the location
3828         in the Boot Options File(BOF) where the configuration file was
3829         found when the system last rebooted."
3830    ::= { tmnxCpmCardEntry 27 }
3831
3832tmnxCpmCardBootOptionLastSaved OBJECT-TYPE
3833    SYNTAX      DateAndTime
3834    MAX-ACCESS  read-only
3835    STATUS      current
3836    DESCRIPTION
3837        "The date and time the boot options file (BOF) was last saved.
3838         If tmnxCpmCardBootOptionLastSaved is more recent than the value
3839         of tmnxHwSwLastBoot, the boot options file has been edited
3840         since the software was booted and different software images or
3841         configuration will likely be used when this card is next rebooted."
3842    ::= { tmnxCpmCardEntry 28 }
3843
3844tmnxCpmCardMasterSlaveRefState    OBJECT-TYPE
3845    SYNTAX      INTEGER {
3846                    primaryRef          (1),
3847                    secondaryRef        (2),
3848                    notInitialized      (3)
3849                }
3850    MAX-ACCESS  read-only
3851    STATUS      current
3852    DESCRIPTION
3853        "The current Master/Slave clocking reference designation.
3854
3855         primaryRef       Indicates this card is designated as the primary
3856                          clocking reference in a redundant system.
3857         secondaryRef     Indicates this card is designated as the secondary
3858                          clocking reference in a redundant system.
3859         notInitialized   Indicates the clock is not initialized.
3860         "
3861    ::= { tmnxCpmCardEntry 30 }
3862
3863tmnxCpmCardConfigUserLastModified    OBJECT-TYPE
3864    SYNTAX      SnmpAdminString (SIZE(0..64))
3865    MAX-ACCESS  read-only
3866    STATUS      current
3867    DESCRIPTION
3868        "The value of tmnxCpmCardConfigUserLastModified indicates the last
3869         user who modified the configuration.
3870
3871         If the configuration was last modified by an SNMPv1 or SNMPv2
3872         set operation, the value of this object will indicate the SNMP
3873         community string and view name separated by the '/' character.
3874
3875         If the configuration was last modified by an SNMPv3 set operation,
3876         the value of this object will be the SNMPv3 user and view name
3877         separated by the '/' character.
3878
3879         If the configuration has not been saved since the last boot, the
3880         object will have the value of an empty string."
3881    ::= { tmnxCpmCardEntry 31 }
3882
3883tmnxCpmCardCmplxCAMErrOccur      OBJECT-TYPE
3884    SYNTAX      Counter32
3885    MAX-ACCESS  read-only
3886    STATUS      current
3887    DESCRIPTION
3888        "The value of tmnxCpmCardCmplxCAMErrOccur indicates the number of times
3889         the complex experienced an occurrence of a CAM error since
3890         startup, or card reboot."
3891   ::= { tmnxCpmCardEntry 32 }
3892
3893tmnxCpmCardCmplxCAMErrOccurTime  OBJECT-TYPE
3894    SYNTAX      TimeStamp
3895    MAX-ACCESS  read-only
3896    STATUS      current
3897    DESCRIPTION
3898        "The value of tmnxCpmCardCmplxCAMErrOccurTime indicates the last time
3899         tmnxCpmCardCmplxCAMErrOccur incremented."
3900   ::= { tmnxCpmCardEntry 33 }
3901
3902tmnxCpmCardOscillatorType        OBJECT-TYPE
3903    SYNTAX      INTEGER {
3904                    none (1),
3905                    tcxo (2),
3906                    ocxo (3)
3907                }
3908    MAX-ACCESS  read-only
3909    STATUS      current
3910    DESCRIPTION
3911        "The value of tmnxCpmCardOscillatorType indicates the type of oscillator
3912         present on the card.
3913
3914         An Oven-Controlled Crystal Oscillator (OCXO) is required for the card
3915         to support IEEE 1588 clock recovery.  A Temperature-Compensated Crystal
3916         Oscillator (TCXO) is not sufficient.
3917
3918         The type of oscillator also affects the holdover performance of the
3919         system."
3920    ::= { tmnxCpmCardEntry 34 }
3921--
3922--      Fabric Card Table - The fabric card table contains information about
3923--      the fabric cards in a chassis.
3924--
3925
3926tmnxFabricLastChange   OBJECT-TYPE
3927    SYNTAX      TimeStamp
3928    MAX-ACCESS  read-only
3929    STATUS      current
3930    DESCRIPTION
3931        "The value of sysUpTime when the tmnxFabricTable was last changed."
3932    ::= { tmnxCardObjs 5 }
3933
3934tmnxFabricTable         OBJECT-TYPE
3935    SYNTAX      SEQUENCE OF TmnxFabricEntry
3936    MAX-ACCESS  not-accessible
3937    STATUS      current
3938    DESCRIPTION
3939        "The tmnxFabricTable has an entry for each fabric card slot in
3940         each chassis in the TMNX system."
3941    ::= { tmnxCardObjs 6 }
3942
3943tmnxFabricEntry         OBJECT-TYPE
3944    SYNTAX      TmnxFabricEntry
3945    MAX-ACCESS  not-accessible
3946    STATUS      current
3947    DESCRIPTION
3948        "Each row entry represents a fabric card slot in a chassis in
3949         the system.  Entries cannot be created and deleted via
3950         SNMP SET operations.  When a tmnxChassisEntry is created,
3951         a tmnxFabricEntry is created for each fabric card slot in that
3952         chassis.  Before a tmnxChassisEntry can be deleted, each
3953         tmnxFabricEntry for that chassis must be in the proper state
3954         for removal."
3955    INDEX   { tmnxChassisIndex, tmnxFabricSlotNum }
3956    ::= { tmnxFabricTable 1 }
3957
3958TmnxFabricEntry                  ::= SEQUENCE {
3959    tmnxFabricSlotNum                Unsigned32,
3960    tmnxFabricAssignedType           TmnxFabricType,
3961    tmnxFabricEquippedType           TmnxFabricType,
3962    tmnxFabricHwIndex                TmnxHwIndex,
3963    tmnxFabricSupportedTypes         TmnxFabricSuppType,
3964    tmnxFabricReboot                 TmnxActionType
3965}
3966
3967tmnxFabricSlotNum     OBJECT-TYPE
3968    SYNTAX      Unsigned32 (1..16)
3969    MAX-ACCESS  not-accessible
3970    STATUS      current
3971    DESCRIPTION
3972        "The unique value which identifies this fabric slot within a
3973         chassis in the system. The CPM cards and IOM cards cannot be
3974         physically inserted into the switch fabric card slots.  In
3975         some models, the CPM is not a separate card, but rather a
3976         module on a Fabric card."
3977    ::= { tmnxFabricEntry 1 }
3978
3979tmnxFabricAssignedType           OBJECT-TYPE
3980    SYNTAX      TmnxFabricType
3981    MAX-ACCESS  read-write
3982    STATUS      current
3983    DESCRIPTION
3984        "The administratively assigned switch fabric card type that
3985         should occupy this fabric slot in this chassis."
3986    DEFVAL { 2 }
3987    ::= { tmnxFabricEntry 2 }
3988
3989tmnxFabricEquippedType           OBJECT-TYPE
3990    SYNTAX      TmnxFabricType
3991    MAX-ACCESS  read-only
3992    STATUS      current
3993    DESCRIPTION
3994        "The switch fabric card type that is physically inserted into
3995         this slot in this chassis."
3996    ::= { tmnxFabricEntry 3 }
3997
3998tmnxFabricHwIndex                OBJECT-TYPE
3999    SYNTAX      TmnxHwIndex
4000    MAX-ACCESS  read-only
4001    STATUS      current
4002    DESCRIPTION
4003        "The value of tmnxHwIndex is the index into the tmnxHwTable to
4004         locate the row entry that represents the hardware component
4005         information for this fabric card."
4006    ::= { tmnxFabricEntry 4 }
4007
4008tmnxFabricSupportedTypes         OBJECT-TYPE
4009    SYNTAX      TmnxFabricSuppType
4010    MAX-ACCESS  read-only
4011    STATUS      current
4012    DESCRIPTION
4013        "A bit-mask that specifies what fabric card types can be configured
4014         in this slot in this chassis."
4015    ::= { tmnxFabricEntry 5 }
4016
4017tmnxFabricReboot                 OBJECT-TYPE
4018    SYNTAX      TmnxActionType
4019    MAX-ACCESS  read-write
4020    STATUS      current
4021    DESCRIPTION
4022        "Setting this variable to 'doAction' causes the fabric to execute
4023         a soft-reboot."
4024    DEFVAL { notApplicable }
4025    ::= { tmnxFabricEntry 6 }
4026
4027--
4028--  Flash Drive Table
4029--
4030
4031tmnxCpmFlashTable OBJECT-TYPE
4032    SYNTAX          SEQUENCE OF TmnxCpmFlashEntry
4033    MAX-ACCESS      not-accessible
4034    STATUS          current
4035    DESCRIPTION
4036        "This table contains information about Flash devices on a CPM card."
4037    ::= { tmnxCardObjs 7 }
4038
4039tmnxCpmFlashEntry OBJECT-TYPE
4040    SYNTAX          TmnxCpmFlashEntry
4041    MAX-ACCESS      not-accessible
4042    STATUS          current
4043    DESCRIPTION
4044        "Contains information regarding a CPM card's flash unit."
4045    INDEX   { tmnxChassisIndex, tmnxCardSlotNum, tmnxCpmFlashId }
4046    ::= { tmnxCpmFlashTable 1 }
4047
4048TmnxCpmFlashEntry ::=
4049    SEQUENCE {
4050        tmnxCpmFlashId                  Unsigned32,
4051        tmnxCpmFlashOperStatus          TmnxDeviceState,
4052        tmnxCpmFlashSerialNumber        TItemDescription,
4053        tmnxCpmFlashFirmwareRevision    TItemDescription,
4054        tmnxCpmFlashModelNumber         TItemDescription,
4055        tmnxCpmFlashCapacity            Unsigned32,
4056        tmnxCpmFlashUsed                Unsigned32,
4057        tmnxCpmFlashHwIndex             TmnxHwIndex
4058    }
4059
4060tmnxCpmFlashId OBJECT-TYPE
4061    SYNTAX          Unsigned32 (1..32)
4062    MAX-ACCESS      not-accessible
4063    STATUS          current
4064    DESCRIPTION
4065        "The unique identifier index for a flash device on a CPM card."
4066    ::= { tmnxCpmFlashEntry 1 }
4067
4068tmnxCpmFlashOperStatus OBJECT-TYPE
4069    SYNTAX         TmnxDeviceState
4070    MAX-ACCESS     read-only
4071    STATUS         current
4072    DESCRIPTION
4073        "Current status of this flash unit on this CPM card."
4074    ::= { tmnxCpmFlashEntry 2 }
4075
4076tmnxCpmFlashSerialNumber OBJECT-TYPE
4077    SYNTAX        TItemDescription
4078    MAX-ACCESS    read-only
4079    STATUS        current
4080    DESCRIPTION
4081        "The serial number for this flash unit on this CPM card."
4082        ::= { tmnxCpmFlashEntry 3 }
4083
4084tmnxCpmFlashFirmwareRevision OBJECT-TYPE
4085    SYNTAX        TItemDescription
4086    MAX-ACCESS    read-only
4087    STATUS        current
4088    DESCRIPTION
4089        "The firmware revision number for this flash unit on this CPM card."
4090    ::= { tmnxCpmFlashEntry 4 }
4091
4092tmnxCpmFlashModelNumber OBJECT-TYPE
4093    SYNTAX        TItemDescription
4094    MAX-ACCESS    read-only
4095    STATUS        current
4096    DESCRIPTION
4097        "The model number for this flash unit on this CPM card."
4098    ::= { tmnxCpmFlashEntry 5 }
4099
4100tmnxCpmFlashCapacity    OBJECT-TYPE
4101    SYNTAX      Unsigned32
4102    UNITS       "sectors"
4103    MAX-ACCESS  read-only
4104    STATUS      current
4105    DESCRIPTION
4106        "The value of tmnxCpmFlashCapacity indicates the maximum size
4107         of this flash unit in 512-byte sectors."
4108    ::= { tmnxCpmFlashEntry 6 }
4109
4110tmnxCpmFlashUsed    OBJECT-TYPE
4111    SYNTAX      Unsigned32
4112    UNITS       "sectors"
4113    MAX-ACCESS  read-only
4114    STATUS      current
4115    DESCRIPTION
4116        "The value of tmnxCpmFlashUsed indicates the amount used, in
4117         512-byte sectors, of this flash unit's total capacity."
4118    ::= { tmnxCpmFlashEntry 7 }
4119
4120tmnxCpmFlashHwIndex   OBJECT-TYPE
4121    SYNTAX      TmnxHwIndex
4122    MAX-ACCESS  read-only
4123    STATUS      current
4124    DESCRIPTION
4125        "The value of tmnxHwIndex is the index into the tmnxHwTable for
4126         the row entry that represents the hardware component information
4127         for this flash unit."
4128    ::= { tmnxCpmFlashEntry 8 }
4129
4130
4131--
4132--      MDA table
4133--
4134tmnxMDATable OBJECT-TYPE
4135    SYNTAX  SEQUENCE OF TmnxMDAEntry
4136    MAX-ACCESS  not-accessible
4137    STATUS      current
4138    DESCRIPTION
4139        "The tmnxMDATable has an entry for each MDA slot in each IOM
4140         card in this chassis in the TMNX system."
4141    ::= { tmnxCardObjs 8 }
4142
4143tmnxMDAEntry       OBJECT-TYPE
4144    SYNTAX      TmnxMDAEntry
4145    MAX-ACCESS  not-accessible
4146    STATUS      current
4147    DESCRIPTION
4148        "Each row entry represents a MDA slot in an IOM card in a
4149         chassis in the system.  Entries cannot be created and
4150         deleted via SNMP SET operations.  When a tmnxCardEntry
4151         has tmnxCardAssignedType or tmnxCardEquippedType equal to
4152         an IOM card type that supports MDA slots, a tmnxMDAEntry is
4153         created by the agent for each MDA slot on that IOM card.
4154         Before a tmnxCardEntry can be deleted, each tmnxMDAEntry for
4155         that card must be in the proper state for removal."
4156    INDEX   { tmnxChassisIndex, tmnxCardSlotNum, tmnxMDASlotNum }
4157    ::= { tmnxMDATable 1 }
4158
4159TmnxMDAEntry ::=
4160    SEQUENCE {
4161        tmnxMDASlotNum                   Unsigned32,
4162        tmnxMDASupportedTypes            TmnxMDASuppType,
4163        tmnxMDAAllowedTypes              TmnxMdaType,
4164        tmnxMDAAssignedType              TmnxMdaType,
4165        tmnxMDAEquippedType              TmnxMdaType,
4166        tmnxMDAHwIndex                   TmnxHwIndex,
4167        tmnxMDAMaxPorts                  INTEGER,
4168        tmnxMDAEquippedPorts             Unsigned32,
4169        tmnxMDATxTimingSelected          INTEGER,
4170        tmnxMDASyncIfTimingStatus        INTEGER,
4171        tmnxMDANetworkIngQueues          TNamedItem,
4172        tmnxMDACapabilities              BITS,
4173        tmnxMDAMinChannelization         TmnxMDAChanType,
4174        tmnxMDAMaxChannelization         TmnxMDAChanType,
4175        tmnxMDAMaxChannels               Unsigned32,
4176        tmnxMDAChannelsInUse             Unsigned32,
4177        tmnxMDACcagId                    TmnxCcagId,
4178        tmnxMDAReboot                    TmnxActionType,
4179        tmnxMDAHiBwMcastSource           TruthValue,
4180        tmnxMDAHiBwMcastAlarm            TruthValue,
4181        tmnxMDAHiBwMcastTapCount         Gauge32,
4182        tmnxMDAHiBwMcastGroup            Unsigned32,
4183        tmnxMDAClockMode                 INTEGER,
4184        tmnxMDADiffTimestampFreq         Unsigned32,
4185        tmnxMDAIngHsmdaSchedPolicy       TNamedItemOrEmpty,
4186        tmnxMDAMcPathMgmtBwPlcyName      TNamedItem,
4187        tmnxMDAMcPathMgmtPriPathLimit    Unsigned32,
4188        tmnxMDAMcPathMgmtSecPathLimit    Unsigned32,
4189        tmnxMDAMcPathMgmtAncPathLimit    Unsigned32,
4190        tmnxMDAMcPathMgmtAdminState      TmnxAdminState,
4191        tmnxMDAIngNamedPoolPolicy        TNamedItemOrEmpty,
4192        tmnxMDAEgrNamedPoolPolicy        TNamedItemOrEmpty,
4193        tmnxMDAIngHsmdaPoolPolicy        TNamedItemOrEmpty,
4194        tmnxMDAEgrHsmdaPoolPolicy        TNamedItemOrEmpty,
4195        tmnxMDAMcPathMgmtPriInUseBw      Gauge32,
4196        tmnxMDAMcPathMgmtSecInUseBw      Gauge32,
4197        tmnxMDAMcPathMgmtAncInUseBw      Gauge32,
4198        tmnxMDAMcPathMgmtBlkHoleInUseBw  Gauge32,
4199        tmnxMDASynchronousEthernet       INTEGER,
4200        tmnxMDAXplErrorTime              TimeStamp,
4201        tmnxMDAXplFailedCount            Gauge32,
4202        tmnxMDAAtmMode                   TmnxMdaAtmMode,
4203        tmnxMDAEgrHsmdaThrshLoBrstMult   Integer32,
4204        tmnxMDAEgrHsmdaThrshHiBrstInc    Integer32,
4205        tmnxMDAIsaTunnelGroup            TmnxTunnelGroupIdOrZero,
4206        tmnxMDAIsaTunnelGroupInUse       TruthValue
4207    }
4208
4209tmnxMDASlotNum     OBJECT-TYPE
4210    SYNTAX      Unsigned32 (0..16)
4211    MAX-ACCESS  not-accessible
4212    STATUS      current
4213    DESCRIPTION
4214        "The unique value which identifies this MDA slot within a
4215         specific IOM card in the system.  Rows with a tmnxMDASlotNum
4216         value of zero (0) represent the special case of an IOM card
4217         without MDA slots but that instead has its ports directly
4218         on the IOM card itself.  In that case, there should be only
4219         that one row entry in the tmnxMDATable for that IOM card."
4220    ::= { tmnxMDAEntry 1 }
4221
4222tmnxMDASupportedTypes   OBJECT-TYPE
4223    SYNTAX      TmnxMDASuppType
4224    MAX-ACCESS  read-only
4225    STATUS      current
4226    DESCRIPTION
4227        "A bit-mask that specifies what MDA card types can be configured
4228         in this slot in this chassis."
4229    ::= { tmnxMDAEntry 2 }
4230
4231tmnxMDAAllowedTypes OBJECT-TYPE
4232    SYNTAX      TmnxMdaType
4233    MAX-ACCESS  read-write
4234    STATUS      obsolete
4235    DESCRIPTION
4236        "An integer that specified what MDA card types the administrator
4237         has designated be allowed to be inserted into this slot.
4238         If the slot has not-been pre-provisioned and a MDA card that
4239         does not match one of the allowed types is inserted into
4240         this slot, a mis-match alarm will be raised.
4241
4242         The object was made obsolete in the 3.0 release."
4243    ::= { tmnxMDAEntry 3 }
4244
4245tmnxMDAAssignedType        OBJECT-TYPE
4246    SYNTAX      TmnxMdaType
4247    MAX-ACCESS  read-write
4248    STATUS      current
4249    DESCRIPTION
4250        "An integer that indicates the administratively assigned
4251         (pre-provisioned) MDA card type that should occupy this slot in
4252         this chassis.  If tmnxMDAAssignedType has a value of
4253         'unassigned', this slot has not yet been pre-provisioned."
4254    DEFVAL { 1 }
4255    ::= { tmnxMDAEntry 4 }
4256
4257tmnxMDAEquippedType        OBJECT-TYPE
4258    SYNTAX      TmnxMdaType
4259    MAX-ACCESS  read-only
4260    STATUS      current
4261    DESCRIPTION
4262        "An integer that indicates the MDA card type that is physically
4263         inserted into this slot in this chassis.  If the slot has been
4264         pre-provisioned, tmnxMDAAssignedType is not equal 'unassigned',
4265         and the value of tmnxMDAEquippedType is not the same as
4266         tmnxMDAAssignedType, a mis-match alarm will be raised.
4267         A value of 0 indicates the equipped MDA is not supported by
4268         this software release."
4269    ::= { tmnxMDAEntry 5 }
4270
4271tmnxMDAHwIndex       OBJECT-TYPE
4272    SYNTAX      TmnxHwIndex
4273    MAX-ACCESS  read-only
4274    STATUS      current
4275    DESCRIPTION
4276        "The value of tmnxHwIndex is the index into the tmnxHwTable for
4277         the row entry that represents the hardware component information
4278         for this MDA card."
4279    ::= { tmnxMDAEntry 6 }
4280
4281tmnxMDAMaxPorts    OBJECT-TYPE
4282    SYNTAX      INTEGER (0..127)
4283    MAX-ACCESS  read-only
4284    STATUS      current
4285    DESCRIPTION
4286        "The maximum number of ports that can be equipped on this MDA card."
4287    ::= { tmnxMDAEntry 7 }
4288
4289tmnxMDAEquippedPorts       OBJECT-TYPE
4290    SYNTAX      Unsigned32
4291    MAX-ACCESS  read-only
4292    STATUS      current
4293    DESCRIPTION
4294        "The value of tmnxMDAEquippedPorts indicates the number of ports
4295         equipped on this MDA card."
4296    ::= { tmnxMDAEntry 8 }
4297
4298tmnxMDATxTimingSelected       OBJECT-TYPE
4299    SYNTAX      INTEGER
4300                {
4301                    cpm-card-A(1),
4302                    cpm-card-B(2),
4303                    local(3),
4304                    holdover(4),
4305                    not-applicable(5)
4306                }
4307    MAX-ACCESS  read-only
4308    STATUS      current
4309    DESCRIPTION
4310        "The transmit timing method which is presently selected and being
4311         used by this MDA.
4312         tmnxMDATxTimingSelected will be set to 'not-applicable' if this MDA
4313         does not use the transmit timing subsystem."
4314    ::= { tmnxMDAEntry 10 }
4315
4316tmnxMDASyncIfTimingStatus       OBJECT-TYPE
4317    SYNTAX      INTEGER
4318                {
4319                    qualified(1),
4320                    not-qualified(2),
4321                    not-applicable(3)
4322                }
4323    MAX-ACCESS  read-only
4324    STATUS      current
4325    DESCRIPTION
4326        "Indicates the status of the synchronous equipment timing subsystem.
4327         If the tmnxSyncIfTimingRef1Qualified and tmnxSyncIfTimingRef2Qualified
4328         are both set to 'not-qualified, then tmnxMDASyncIfTimingStatus is set
4329         to 'not-qualified'. If any of the timing references is in use, then
4330         tmnxMDASyncIfTimingStatus is set to 'qualified'.
4331         tmnxMDASyncIfTimingStatus will be set to 'not-applicable' if this MDA
4332         does not use the transmit timing subsystem."
4333    ::= { tmnxMDAEntry 11 }
4334
4335tmnxMDANetworkIngQueues      OBJECT-TYPE
4336    SYNTAX      TNamedItem
4337    MAX-ACCESS  read-write
4338    STATUS      current
4339    DESCRIPTION
4340        "Specifies the network queue policy being used for this object to
4341        define the queueing structure for this object."
4342    DEFVAL { "default" }
4343    ::= { tmnxMDAEntry 12 }
4344
4345tmnxMDACapabilities      OBJECT-TYPE
4346    SYNTAX      BITS {
4347                    isEthernet(0),
4348                    isSonet(1),
4349                    isTDM(2),
4350                    supportsPPP(3),
4351                    supportsFR(4),
4352                    supportsATM(5),
4353                    supportscHDLC(6),
4354                    isCMA(7),
4355                    supportsCEM(8)
4356                }
4357    MAX-ACCESS  read-only
4358    STATUS      current
4359    DESCRIPTION
4360        "tmnxMDACapabilities indicates the capabilities of this MDA.
4361         It identifies the type of MDA and the protocols that can run on it."
4362    ::= { tmnxMDAEntry 13 }
4363
4364tmnxMDAMinChannelization      OBJECT-TYPE
4365    SYNTAX      TmnxMDAChanType
4366    MAX-ACCESS  read-only
4367    STATUS      current
4368    DESCRIPTION
4369        "tmnxMDAMinChannelization indicates the minimum size of the channel that
4370         can exist on this MDA."
4371    ::= { tmnxMDAEntry 14 }
4372
4373tmnxMDAMaxChannelization      OBJECT-TYPE
4374    SYNTAX      TmnxMDAChanType
4375    MAX-ACCESS  read-only
4376    STATUS      current
4377    DESCRIPTION
4378        "tmnxMDAMaxChannelization indicates the maximum size of the channel that
4379         can exist on this MDA."
4380    ::= { tmnxMDAEntry 15 }
4381
4382tmnxMDAMaxChannels      OBJECT-TYPE
4383    SYNTAX      Unsigned32
4384    MAX-ACCESS  read-only
4385    STATUS      current
4386    DESCRIPTION
4387        "tmnxMDAMaxChannels is applicable for SONET and TDM MDAs only. It
4388         indicates the total number of leaf SONET paths, TDM channels
4389         and bundles on the MDA that may be configured to pass traffic."
4390    ::= { tmnxMDAEntry 16 }
4391
4392tmnxMDAChannelsInUse      OBJECT-TYPE
4393    SYNTAX      Unsigned32
4394    MAX-ACCESS  read-only
4395    STATUS      current
4396    DESCRIPTION
4397        "tmnxMDAChannelsInUse is applicable for SONET and TDM MDAs only.  It
4398         indicates the total number of leaf SONET paths, TDM channels and
4399         bundles on the MDA which are in use.  A leaf SONET path or TDM
4400         channel which is currently capable of passing traffic is considered
4401         to be in use.  Also, a SONET path or TDM channel which is
4402         channelized and has no subchannels capable of passing traffic
4403         is considered to be in use.  A SONET path or TDM channel which is
4404         channelized and has one or more subchannels capable of passing
4405         traffic is not considered to be in use, although the subchannels
4406         themselves are considered to be in use.  A bundle is considered to
4407         be a channel in use as are each of its members since they are TDM
4408         channels capable of passing traffic."
4409    ::= { tmnxMDAEntry 17 }
4410
4411tmnxMDACcagId        OBJECT-TYPE
4412    SYNTAX      TmnxCcagId
4413    MAX-ACCESS  read-write
4414    STATUS      current
4415    DESCRIPTION
4416        "When tmnxMDAAssignedType has a value of 'cca' , the value of
4417         tmnxMDACcagId specifies the Cross Connect Aggregation Group (CCAG)
4418         entry this MDA is provisioned on.  If this entry does not represent
4419         a 'cca' MDA or is not associated with a CCAG, tmnxMDACcagId
4420         has a value of zero. "
4421    DEFVAL { 0 }
4422    ::= { tmnxMDAEntry 18 }
4423
4424tmnxMDAReboot       OBJECT-TYPE
4425    SYNTAX      TmnxActionType
4426    MAX-ACCESS  read-write
4427    STATUS      current
4428    DESCRIPTION
4429        "Setting this variable to 'doAction' causes the MDA to execute
4430         a soft-reboot."
4431    DEFVAL { notApplicable }
4432    ::= { tmnxMDAEntry 19 }
4433
4434tmnxMDAHiBwMcastSource   OBJECT-TYPE
4435    SYNTAX      TruthValue
4436    MAX-ACCESS  read-write
4437    STATUS      current
4438    DESCRIPTION
4439        "The value of tmnxMDAHiBwMcastSource specifies if this MDA should
4440         attempt to allocate separate fabric planes to allocate high bandwidth
4441         multicast traffic taps.
4442
4443         tmnxMDAHiBwMcastGroup must be set in the same SNMP request PDU with
4444         tmnxMDAHiBwMcastSource or an 'inconsistentValue' error will be
4445         returned."
4446    DEFVAL { false }
4447    ::= { tmnxMDAEntry 20 }
4448
4449tmnxMDAHiBwMcastAlarm     OBJECT-TYPE
4450    SYNTAX      TruthValue
4451    MAX-ACCESS  read-write
4452    STATUS      current
4453    DESCRIPTION
4454        "The value of tmnxMDAHiBwMcastAlarm specifies if a
4455         tmnxChassisHiBwMcastAlarm alarm is raised if there are more than
4456         one high bandwidth multicast traffic taps sharing a plane."
4457    DEFVAL { true }
4458    ::= { tmnxMDAEntry 21 }
4459
4460tmnxMDAHiBwMcastTapCount     OBJECT-TYPE
4461    SYNTAX      Gauge32
4462    MAX-ACCESS  read-only
4463    STATUS      current
4464    DESCRIPTION
4465        "The value of tmnxMDAHiBwMcastTapCount indicates the number of high
4466         bandwidth multicast traffic taps on this MDA."
4467    ::= { tmnxMDAEntry 22 }
4468
4469tmnxMDAHiBwMcastGroup  OBJECT-TYPE
4470    SYNTAX      Unsigned32 (0..32)
4471    MAX-ACCESS  read-write
4472    STATUS      current
4473    DESCRIPTION
4474        "The value of tmnxMDAHiBwMcastGroup specifies the group of high
4475         bandwidth multicast traffic taps to which this tap belongs.
4476
4477         A value of '0' specifies that this tap is not a member of any High
4478         Bandwidth Multicast group.
4479
4480         On an IOM of type 'iom-10g', the value of tmnxMDAHiBwMcastGroup
4481         should be the same as the value of tmnxMDAHiBwMcastGroup set on the
4482         other MDA residing on the IOM if the tmnxMDAHiBwMcastSource is set
4483         to 'true'. Attempt to set to different values will result in an
4484         'inconsistentValue' error.
4485
4486         tmnxMDAHiBwMcastGroup must be set in the same SNMP request PDU with
4487         tmnxMDAHiBwMcastSource or an 'inconsistentValue' error will be
4488         returned."
4489    DEFVAL { 0 }
4490    ::= { tmnxMDAEntry 23 }
4491
4492tmnxMDAClockMode  OBJECT-TYPE
4493    SYNTAX      INTEGER {
4494                    notApplicable (0),
4495                    adaptive (1),
4496                    differential (2)
4497                }
4498    MAX-ACCESS  read-write
4499    STATUS      current
4500    DESCRIPTION
4501        "The value of tmnxMDAClockMode specifies the clock mode
4502         of the MDA.
4503
4504         notApplicable - The MDA does not support any clock modes or domains.
4505         adaptive      - The MDA is in 'adaptive' clock mode.  This allows
4506                         adaptive clock domains to be created.
4507         differential  - The MDA is in 'differential clock mode.  This allows
4508                         differential clock domains to be created.
4509
4510         The value of tmnxMDAClockMode can be changed when there are no ports
4511         created on the MDA.  If there are ports created, a shutdown of the
4512         MDA is required in order to change the value."
4513    DEFVAL { notApplicable }
4514    ::= { tmnxMDAEntry 24 }
4515
4516tmnxMDADiffTimestampFreq  OBJECT-TYPE
4517    SYNTAX      Unsigned32 (0|19440|77760|103680)
4518    UNITS       "kilohertz"
4519    MAX-ACCESS  read-write
4520    STATUS      current
4521    DESCRIPTION
4522        "The value of tmnxMDADiffTimestampFreq specifies the differential
4523         timestamp frequency of the differential clock on the MDA.
4524
4525         The value must be a multiple of 8 KHz.
4526
4527         This value can only be changed if the value of tmnxMDAClockMode is
4528         'differential (2)' and there are no ports created on the MDA.  If
4529         there are ports created, a shutdown of the MDA is required in order
4530         to change the value.
4531
4532         If the value of tmnxMDAClockMode is 'differential (2) then the default
4533         is 103,680 KHz.
4534         If the value of tmnxMDAClockMode is not 'differential (2)' then
4535         this value is 0 KHz and cannot be changed."
4536    DEFVAL { 0 }
4537    ::= { tmnxMDAEntry 25 }
4538
4539tmnxMDAIngHsmdaSchedPolicy      OBJECT-TYPE
4540    SYNTAX      TNamedItemOrEmpty
4541    MAX-ACCESS  read-write
4542    STATUS      obsolete
4543    DESCRIPTION
4544        "The value of tmnxMDAIngHsmdaSchedPolicy specifies the name of
4545         High Scale MDA (HSMDA) scheduler policy to use on the ingress
4546         of the MDA.
4547
4548         An 'inconsistentValue' error is returned if this object is set
4549         to a value which does not have a corresponding entry in
4550         TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyTable.
4551
4552         When the value of tmnxMDAAssignedType specifies a
4553         non-HSMDA MDA Type, an 'inconsistentValue' error
4554         is returned if this object is set to any non-empty string.
4555
4556         This object is obsoleted in 10.0 Release."
4557    DEFVAL { "" }
4558    ::= { tmnxMDAEntry 26 }
4559
4560tmnxMDAMcPathMgmtBwPlcyName     OBJECT-TYPE
4561    SYNTAX      TNamedItem
4562    MAX-ACCESS  read-write
4563    STATUS      current
4564    DESCRIPTION
4565        "The value of tmnxMDAMcPathMgmtBwPlcyName specifies the multicast policy
4566         name configured on the MDA."
4567    DEFVAL { "default" }
4568    ::= { tmnxMDAEntry 27 }
4569
4570tmnxMDAMcPathMgmtPriPathLimit   OBJECT-TYPE
4571    SYNTAX      Unsigned32 (0|1..2000)
4572    UNITS       "mega-bits-per-second"
4573    MAX-ACCESS  read-write
4574    STATUS      current
4575    DESCRIPTION
4576        "The value of tmnxMDAMcPathMgmtPriPathLimit specifies the primary path
4577         limit for the MDA."
4578    DEFVAL { 0 }
4579    ::= { tmnxMDAEntry 28 }
4580
4581tmnxMDAMcPathMgmtSecPathLimit OBJECT-TYPE
4582    SYNTAX      Unsigned32 (0|1..2000)
4583    UNITS       "mega-bits-per-second"
4584    MAX-ACCESS  read-write
4585    STATUS      current
4586    DESCRIPTION
4587        "The value of tmnxMDAMcPathMgmtSecPathLimit specifies the secondary path
4588         limit for the MDA."
4589    DEFVAL { 0 }
4590    ::= { tmnxMDAEntry 29 }
4591
4592tmnxMDAMcPathMgmtAncPathLimit        OBJECT-TYPE
4593    SYNTAX      Unsigned32 (0|1..5000)
4594    UNITS       "mega-bits-per-second"
4595    MAX-ACCESS  read-write
4596    STATUS      current
4597    DESCRIPTION
4598        "The value of tmnxMDAMcPathMgmtAncPathLimit specifies the ancillary path
4599         limit for the MDA."
4600    DEFVAL { 0 }
4601    ::= { tmnxMDAEntry 30 }
4602
4603tmnxMDAMcPathMgmtAdminState        OBJECT-TYPE
4604    SYNTAX      TmnxAdminState
4605    MAX-ACCESS  read-write
4606    STATUS      current
4607    DESCRIPTION
4608        "The value of tmnxMDAMcPathMgmtAdminState specifies administrative state
4609         of this multicast path on the MDA."
4610    DEFVAL { outOfService }
4611    ::= { tmnxMDAEntry 31 }
4612
4613tmnxMDAIngNamedPoolPolicy OBJECT-TYPE
4614    SYNTAX      TNamedItemOrEmpty
4615    MAX-ACCESS  read-write
4616    STATUS      current
4617    DESCRIPTION
4618        "The value of tmnxMDAIngNamedPoolPolicy specifies a named pool
4619         policy associated with an MDA ingress context. The policy
4620         governs the way named pools are created at the MDA level."
4621    DEFVAL { ''H }
4622    ::= { tmnxMDAEntry 32 }
4623
4624tmnxMDAEgrNamedPoolPolicy OBJECT-TYPE
4625    SYNTAX      TNamedItemOrEmpty
4626    MAX-ACCESS  read-write
4627    STATUS      current
4628    DESCRIPTION
4629        "The value of tmnxMDAEgrNamedPoolPolicy specifies a named pool
4630         policy associated with an MDA egress context. The policy
4631         governs the way named pools are created at the MDA level."
4632    DEFVAL { ''H }
4633    ::= { tmnxMDAEntry 33 }
4634
4635tmnxMDAIngHsmdaPoolPolicy      OBJECT-TYPE
4636    SYNTAX      TNamedItemOrEmpty
4637    MAX-ACCESS  read-write
4638    STATUS      obsolete
4639    DESCRIPTION
4640        "The value of tmnxMDAIngHsmdaPoolPolicy specifies  the name of
4641         High Scale MDA (HSMDA) pool policy to use on the ingress
4642         of the MDA.
4643
4644         An 'inconsistentValue' error is returned if this object is set
4645         to a value which does not have a corresponding entry in
4646         TIMETRA-QOS-MIB::tHsmdaPoolPolicyTable.
4647
4648         When the value of tmnxMDAAssignedType specifies a
4649         non-HSMDA MDA Type, an 'inconsistentValue' error
4650         is returned if this object is set to any non-empty string.
4651
4652         This object is obsoleted in 10.0 Release."
4653    DEFVAL { "" }
4654    ::= { tmnxMDAEntry 34 }
4655
4656tmnxMDAEgrHsmdaPoolPolicy      OBJECT-TYPE
4657    SYNTAX      TNamedItemOrEmpty
4658    MAX-ACCESS  read-write
4659    STATUS      current
4660    DESCRIPTION
4661        "The value of tmnxMDAEgrHsmdaPoolPolicy specifies  the name of
4662         High Scale MDA (HSMDA) pool policy to use on the egress
4663         of the MDA.
4664
4665         An 'inconsistentValue' error is returned if this object is set
4666         to a value which does not have a corresponding entry in
4667         TIMETRA-QOS-MIB::tHsmdaPoolPolicyTable.
4668
4669         When the value of tmnxMDAAssignedType specifies a
4670         non-HSMDA MDA Type, an 'inconsistentValue' error
4671         is returned if this object is set to any non-empty string."
4672    DEFVAL { "" }
4673    ::= { tmnxMDAEntry 35 }
4674
4675tmnxMDAMcPathMgmtPriInUseBw      OBJECT-TYPE
4676    SYNTAX      Gauge32
4677    UNITS       "Kbps"
4678    MAX-ACCESS  read-only
4679    STATUS      current
4680    DESCRIPTION
4681        "The value of tmnxMDAMcPathMgmtPriInUseBw indicates the in use
4682         ingress multicast bandwidth for the primary forwarding path."
4683    ::= { tmnxMDAEntry 36 }
4684
4685tmnxMDAMcPathMgmtSecInUseBw      OBJECT-TYPE
4686    SYNTAX      Gauge32
4687    UNITS       "Kbps"
4688    MAX-ACCESS  read-only
4689    STATUS      current
4690    DESCRIPTION
4691        "The value of tmnxMDAMcPathMgmtSecInUseBw indicates the in use
4692         ingress multicast bandwidth for the secondary forwarding path."
4693    ::= { tmnxMDAEntry 37 }
4694
4695tmnxMDAMcPathMgmtAncInUseBw      OBJECT-TYPE
4696    SYNTAX      Gauge32
4697    UNITS       "Kbps"
4698    MAX-ACCESS  read-only
4699    STATUS      current
4700    DESCRIPTION
4701        "The value of tmnxMDAMcPathMgmtAncInUseBw indicates the in use
4702         ingress multicast bandwidth for the ancillary forwarding path."
4703    ::= { tmnxMDAEntry 38 }
4704
4705tmnxMDAMcPathMgmtBlkHoleInUseBw  OBJECT-TYPE
4706    SYNTAX      Gauge32
4707    UNITS       "Kbps"
4708    MAX-ACCESS  read-only
4709    STATUS      current
4710    DESCRIPTION
4711        "The value of tmnxMDAMcPathMgmtBlkHoleInUseBw indicates the bandwidth of
4712         the ingress multicast traffic that is being black holed on the MDA."
4713    ::= { tmnxMDAEntry 39 }
4714
4715tmnxMDASynchronousEthernet       OBJECT-TYPE
4716    SYNTAX      INTEGER {
4717                    not-applicable (0),
4718                    enabled        (1),
4719                    disabled       (2)
4720                }
4721    MAX-ACCESS  read-write
4722    STATUS      current
4723    DESCRIPTION
4724        "The value of tmnxMDASynchronousEthernet specifies whether or not
4725         the MDA maintains synchronous Ethernet (syncE) communication on all
4726         of its ports.
4727
4728         not-applicable - The MDA does not support synchronous Ethernet.
4729         enabled        - The MDA is in synchronous mode.
4730         disabled       - The MDA is in asynchronous mode (default).
4731
4732         On MDAs that do not support synchronous ethernet the only supported
4733         value is 'not-applicable (0)'.
4734
4735         If tmnxMDASynchronousEthernet is 'enabled (1)' then any port on the
4736         MDA can be used as a source port in the tmnxSyncIfTimingTable."
4737    DEFVAL { disabled }
4738    ::= { tmnxMDAEntry 40 }
4739
4740tmnxMDAXplErrorTime                  OBJECT-TYPE
4741    SYNTAX       TimeStamp
4742    MAX-ACCESS   read-only
4743    STATUS       current
4744    DESCRIPTION
4745        "The value of tmnxMDAXplErrorTime indicates the last time when
4746         the tmnxEqMdaXplError notification occurred."
4747    ::= { tmnxMDAEntry 41 }
4748
4749tmnxMDAXplFailedCount                OBJECT-TYPE
4750    SYNTAX       Gauge32
4751    MAX-ACCESS   read-only
4752    STATUS       current
4753    DESCRIPTION
4754        "The value of tmnxMDAXplFailedCount indicates the number of XPL failures
4755         on the MDA since startup."
4756    ::= { tmnxMDAEntry 42 }
4757
4758tmnxMDAAtmMode                       OBJECT-TYPE
4759    SYNTAX      TmnxMdaAtmMode
4760    MAX-ACCESS  read-write
4761    STATUS      current
4762    DESCRIPTION
4763        "The value of tmnxMDAAtmMode specifies
4764         the maximum number of Virtual Circuits for the MDA.
4765
4766         On MDA's that do not support ATM, 'notApplicable' is the only allowed
4767         value and this is also the default value.
4768
4769         On MDA's that support ATM, the default value is 'max8kVc'."
4770    ::= { tmnxMDAEntry 43 }
4771
4772tmnxMDAEgrHsmdaThrshLoBrstMult      OBJECT-TYPE
4773    SYNTAX      Integer32 (-1|1..65536)
4774    UNITS       "bytes per megabit of rate"
4775    MAX-ACCESS  read-write
4776    STATUS      current
4777    DESCRIPTION
4778        "The value of tmnxMDAEgrHsmdaThrshLoBrstMult specifies the
4779         bytes per megabit/second of rate multiplier for the aggregate rate of
4780         the queues pertaining to the low burst threshold in the queue group.
4781
4782         When set to the default value '-1', the system will adopt the lowest
4783         usable threshold as a default setting per rate."
4784    DEFVAL { -1 }
4785    ::= { tmnxMDAEntry 44 }
4786
4787tmnxMDAEgrHsmdaThrshHiBrstInc      OBJECT-TYPE
4788    SYNTAX      Integer32 (-1|0..65536)
4789    UNITS       "bytes"
4790    MAX-ACCESS  read-write
4791    STATUS      current
4792    DESCRIPTION
4793        "The value of tmnxMDAEgrHsmdaThrshHiBrstInc specifies the incremental
4794         number of bytes above the low burst limit to be used as the high burst
4795         threshold for the aggregate rate of the queues pertaining to the high
4796         burst threshold in the queue group.
4797
4798         When set to the default value '-1', the system will default to a value
4799         of '4000' bytes."
4800    DEFVAL { -1 }
4801    ::= { tmnxMDAEntry 45 }
4802
4803tmnxMDAIsaTunnelGroup        OBJECT-TYPE
4804    SYNTAX      TmnxTunnelGroupIdOrZero
4805    MAX-ACCESS  read-write
4806    STATUS      current
4807    DESCRIPTION
4808        "The value of tmnxMDAIsaTunnelGroup specifies the tunnel-group
4809         identifiter associated with this MDA."
4810    DEFVAL { 0 }
4811    ::= { tmnxMDAEntry 46 }
4812
4813tmnxMDAIsaTunnelGroupInUse        OBJECT-TYPE
4814    SYNTAX      TruthValue
4815    MAX-ACCESS  read-only
4816    STATUS      current
4817    DESCRIPTION
4818        "The value of tmnxMDAIsaTunnelGroupInUse indicates if this MDA is active
4819         in the Integrated Service Adaptor tunnel group indicated by
4820         tmnxMDAIsaTunnelGroup."
4821    ::= { tmnxMDAEntry 47 }
4822--
4823--  Card Type Definition Table
4824--
4825tmnxCardTypeTable OBJECT-TYPE
4826    SYNTAX      SEQUENCE OF TmnxCardTypeEntry
4827    MAX-ACCESS  not-accessible
4828    STATUS      current
4829    DESCRIPTION
4830        "The card type table has an entry for each Alcatel-Lucent SROS series
4831         card model."
4832    ::= { tmnxCardObjs 9 }
4833
4834tmnxCardTypeEntry    OBJECT-TYPE
4835    SYNTAX      TmnxCardTypeEntry
4836    MAX-ACCESS  not-accessible
4837    STATUS      current
4838    DESCRIPTION
4839        "Each row entry represents an Alcatel-Lucent SROS series Card model.
4840         Rows in this table are created by the agent at initialization and
4841         cannot be created or destroyed by SNMP Get or Set requests."
4842    INDEX   { tmnxCardTypeIndex }
4843    ::= { tmnxCardTypeTable 1 }
4844
4845TmnxCardTypeEntry ::=
4846    SEQUENCE {
4847        tmnxCardTypeIndex        TmnxCardType,
4848        tmnxCardTypeName         TNamedItemOrEmpty,
4849        tmnxCardTypeDescription  TItemDescription,
4850        tmnxCardTypeStatus       TruthValue
4851    }
4852
4853tmnxCardTypeIndex    OBJECT-TYPE
4854    SYNTAX      TmnxCardType
4855    MAX-ACCESS  not-accessible
4856    STATUS      current
4857    DESCRIPTION
4858        "The unique index value which identifies this type of Alcatel-Lucent
4859         SROS series card model."
4860    ::= { tmnxCardTypeEntry 1 }
4861
4862tmnxCardTypeName     OBJECT-TYPE
4863    SYNTAX      TNamedItemOrEmpty
4864    MAX-ACCESS  read-only
4865    STATUS      current
4866    DESCRIPTION
4867        "The administrative name that identifies this type of Alcatel-Lucent
4868         SROS series card model.  This name string may be used in
4869         CLI commands to specify a particular card model type."
4870    ::= { tmnxCardTypeEntry 2 }
4871
4872tmnxCardTypeDescription  OBJECT-TYPE
4873    SYNTAX      TItemDescription
4874    MAX-ACCESS  read-only
4875    STATUS      current
4876    DESCRIPTION
4877        "A detailed description of this Alcatel-Lucent SROS series card
4878         model."
4879    ::= { tmnxCardTypeEntry 3 }
4880
4881tmnxCardTypeStatus       OBJECT-TYPE
4882    SYNTAX      TruthValue
4883    MAX-ACCESS  read-only
4884    STATUS      current
4885    DESCRIPTION
4886        "When tmnxCardTypeStatus has a value of 'true' it indicates that
4887         this card model is supported in this revision of the management
4888         software.  When it has a value of 'false' there is no support."
4889    ::= { tmnxCardTypeEntry 4 }
4890
4891
4892--
4893--  MDA Type Defintion Table
4894--
4895tmnxMdaTypeTable OBJECT-TYPE
4896    SYNTAX      SEQUENCE OF TmnxMdaTypeEntry
4897    MAX-ACCESS  not-accessible
4898    STATUS      current
4899    DESCRIPTION
4900        "The MDA type table has an entry for each Alcatel-Lucent SROS series
4901         MDA card model."
4902    ::= { tmnxCardObjs 10 }
4903
4904tmnxMdaTypeEntry    OBJECT-TYPE
4905    SYNTAX      TmnxMdaTypeEntry
4906    MAX-ACCESS  not-accessible
4907    STATUS      current
4908    DESCRIPTION
4909        "Each row entry represents an Alcatel-Lucent SROS series MDA card
4910         model.  Rows in this table are created by the agent at initialization
4911         and cannot be created or destroyed by SNMP Get or Set requests."
4912    INDEX   { tmnxMdaTypeIndex }
4913    ::= { tmnxMdaTypeTable 1 }
4914
4915TmnxMdaTypeEntry ::=
4916    SEQUENCE {
4917        tmnxMdaTypeIndex        TmnxMdaType,
4918        tmnxMdaTypeName         TNamedItemOrEmpty,
4919        tmnxMdaTypeDescription  TItemDescription,
4920        tmnxMdaTypeStatus       TruthValue
4921    }
4922
4923tmnxMdaTypeIndex    OBJECT-TYPE
4924    SYNTAX      TmnxMdaType
4925    MAX-ACCESS  not-accessible
4926    STATUS      current
4927    DESCRIPTION
4928        "The unique index value which identifies this type of Alcatel-Lucent
4929         SROS series MDA card model."
4930    ::= { tmnxMdaTypeEntry 1 }
4931
4932tmnxMdaTypeName     OBJECT-TYPE
4933    SYNTAX      TNamedItemOrEmpty
4934    MAX-ACCESS  read-only
4935    STATUS      current
4936    DESCRIPTION
4937        "The administrative name that identifies this type of Alcatel-Lucent
4938         SROS series MDA card model.  This name string may be used
4939         in CLI commands to specify a particular MDA card model type."
4940    ::= { tmnxMdaTypeEntry 2 }
4941
4942tmnxMdaTypeDescription  OBJECT-TYPE
4943    SYNTAX      TItemDescription
4944    MAX-ACCESS  read-only
4945    STATUS      current
4946    DESCRIPTION
4947        "A detailed description of this Alcatel-Lucent SROS series MDA card
4948         model."
4949    ::= { tmnxMdaTypeEntry 3 }
4950
4951tmnxMdaTypeStatus       OBJECT-TYPE
4952    SYNTAX      TruthValue
4953    MAX-ACCESS  read-only
4954    STATUS      current
4955    DESCRIPTION
4956        "When tmnxMdaTypeStatus has a value of 'true' it indicates that
4957         this MDA card model is supported in this revision of the management
4958         software.  When it has a value of 'false' there is no support."
4959    ::= { tmnxMdaTypeEntry 4 }
4960
4961--
4962-- Synchronous interface timing information for the CPM card
4963--
4964
4965tmnxSyncIfTimingTable OBJECT-TYPE
4966    SYNTAX  SEQUENCE OF TmnxSyncIfTimingEntry
4967    MAX-ACCESS  not-accessible
4968    STATUS      current
4969    DESCRIPTION
4970        "The synchronous interface timing table has an entry for each cpm
4971         card in the system."
4972    ::= { tmnxCardObjs 11 }
4973
4974tmnxSyncIfTimingEntry    OBJECT-TYPE
4975    SYNTAX      TmnxSyncIfTimingEntry
4976    MAX-ACCESS  not-accessible
4977    STATUS      current
4978    DESCRIPTION
4979       "A row represents the configuration of synchronous equipment timing
4980        subsystem (SETS) of the system. Entries cannot be created and deleted
4981        via SNMP SET operations.  When a tmnxCpmCardEntry is created, a
4982        tmnxSyncIfTimingEntry is created.  SNMP set operations with
4983        tmnxCpmCardSlotNum of the secondary CPM will be denied.
4984
4985        If the value of the reference source port is a valid Port ID then the
4986        reference is a port.  If the value of the source hardware is a valid
4987        non-zero HWIndex then the source is the hardware specified by the
4988        HWIndex."
4989    AUGMENTS    { tmnxCpmCardEntry }
4990    ::= { tmnxSyncIfTimingTable 1 }
4991
4992TmnxSyncIfTimingEntry            ::= SEQUENCE {
4993    tmnxSyncIfTimingRevert           TruthValue,
4994    tmnxSyncIfTimingRefOrder1        TmnxSETSRefSource,
4995    tmnxSyncIfTimingRefOrder2        TmnxSETSRefSource,
4996    tmnxSyncIfTimingRef1SrcPort      TmnxPortID,
4997    tmnxSyncIfTimingRef1AdminStatus  TmnxPortAdminStatus,
4998    tmnxSyncIfTimingRef1InUse        TruthValue,
4999    tmnxSyncIfTimingRef1Qualified    TmnxSETSRefQualified,
5000    tmnxSyncIfTimingRef1Alarm        TmnxSETSRefAlarm,
5001    tmnxSyncIfTimingRef2SrcPort      TmnxPortID,
5002    tmnxSyncIfTimingRef2AdminStatus  TmnxPortAdminStatus,
5003    tmnxSyncIfTimingRef2InUse        TruthValue,
5004    tmnxSyncIfTimingRef2Qualified    TmnxSETSRefQualified,
5005    tmnxSyncIfTimingRef2Alarm        TmnxSETSRefAlarm,
5006    tmnxSyncIfTimingFreqOffset       Integer32,
5007    tmnxSyncIfTimingStatus           INTEGER,
5008    tmnxSyncIfTimingRefOrder3        TmnxSETSRefSource,
5009    tmnxSyncIfTimingBITSIfType       TmnxBITSIfType,
5010    tmnxSyncIfTimingBITSAdminStatus  TmnxPortAdminStatus,
5011    tmnxSyncIfTimingBITSInUse        TruthValue,
5012    tmnxSyncIfTimingBITSQualified    TmnxSETSRefQualified,
5013    tmnxSyncIfTimingBITSAlarm        TmnxSETSRefAlarm,
5014    tmnxSyncIfTimingRef1SrcHw        TmnxHwIndexOrZero,
5015    tmnxSyncIfTimingRef1BITSIfType   TmnxBITSIfType,
5016    tmnxSyncIfTimingRef2SrcHw        TmnxHwIndexOrZero,
5017    tmnxSyncIfTimingRef2BITSIfType   TmnxBITSIfType,
5018    tmnxSyncIfTimingBITSOutAdmStatus TmnxPortAdminStatus,
5019    tmnxSyncIfTimingBITSOutLineLen   INTEGER,
5020    tmnxSyncIfTimingRef1CfgQltyLevel TmnxSSMQualityLevel,
5021    tmnxSyncIfTimingRef1RxQltyLevel  TmnxSSMQualityLevel,
5022    tmnxSyncIfTimingRef2CfgQltyLevel TmnxSSMQualityLevel,
5023    tmnxSyncIfTimingRef2RxQltyLevel  TmnxSSMQualityLevel,
5024    tmnxSyncIfTimingBITSCfgQltyLevel TmnxSSMQualityLevel,
5025    tmnxSyncIfTimingBITSRxQltyLevel  TmnxSSMQualityLevel,
5026    tmnxSyncIfTimingBITS2InUse       TruthValue,
5027    tmnxSyncIfTimingBITS2Qualified   TmnxSETSRefQualified,
5028    tmnxSyncIfTimingBITS2Alarm       TmnxSETSRefAlarm,
5029    tmnxSyncIfTimingBITS2RxQltyLevel TmnxSSMQualityLevel,
5030    tmnxSyncIfTimingRef1State        TmnxRefInState,
5031    tmnxSyncIfTimingRef2State        TmnxRefInState,
5032    tmnxSyncIfTimingBITSState        TmnxRefInState,
5033    tmnxSyncIfTimingBITS2State       TmnxRefInState,
5034    tmnxSyncIfTimingRef1NationalUse  Unsigned32,
5035    tmnxSyncIfTimingRef2NationalUse  Unsigned32,
5036    tmnxSyncIfTimingBITSNationalUse  Unsigned32,
5037    tmnxSyncIfTimingQLSelection      TmnxEnabledDisabled,
5038    tmnxSyncIfTimingOtherCPMInUse    TruthValue,
5039    tmnxSyncIfTimingOtherCPMQual     TmnxSETSRefQualified,
5040    tmnxSyncIfTimingOtherCPMAlarm    TmnxSETSRefAlarm,
5041    tmnxSyncIfTimingOtherCPMState    TmnxRefInState,
5042    tmnxSyncIfTimingBITSOutRefSel    TmnxSETSRefSource,
5043    tmnxSyncIfTimingBITSTxQltyLevel  TmnxSSMQualityLevel,
5044    tmnxSyncIfTimingBITS2AdminStatus TmnxPortAdminStatus,
5045    tmnxSyncIfTimingSystemQltyLevel  TmnxSSMQualityLevel,
5046    tmnxSyncIfTimingRefOrder4        TmnxSETSRefSource,
5047    tmnxSyncIfTimingPTPAdminStatus   TmnxPortAdminStatus,
5048    tmnxSyncIfTimingPTPInUse         TruthValue,
5049    tmnxSyncIfTimingPTPQualified     TmnxSETSRefQualified,
5050    tmnxSyncIfTimingPTPAlarm         TmnxSETSRefAlarm,
5051    tmnxSyncIfTimingPTPCfgQltyLevel  TmnxSSMQualityLevel,
5052    tmnxSyncIfTimingPTPRxQltyLevel   TmnxSSMQualityLevel,
5053    tmnxSyncIfTimingPTPState         TmnxRefInState,
5054    tmnxSyncIfTimingBITSOutSource    TmnxBITSOutSource,
5055    tmnxSyncIfTimingRefOrder5        TmnxSETSRefSource,
5056    tmnxSyncIfTimingBITS2InAdminStatus   TmnxPortAdminStatus,
5057    tmnxSyncIfTimingBITS2OutAdminStatus  TmnxPortAdminStatus,
5058    tmnxSyncIfTimingBITS2TxQltyLevel     TmnxSSMQualityLevel
5059}
5060
5061tmnxSyncIfTimingRevert      OBJECT-TYPE
5062    SYNTAX      TruthValue
5063    MAX-ACCESS  read-only
5064    STATUS      current
5065    DESCRIPTION
5066        "The value of tmnxSyncIfTimingRevert indicates whether the reference
5067         source will revert to a higher priority source that has been
5068         re-validated or newly validated.
5069
5070         The synchronous interface timing subsystem is by default non-revertive
5071         ('false')."
5072    ::= { tmnxSyncIfTimingEntry 1 }
5073
5074tmnxSyncIfTimingRefOrder1      OBJECT-TYPE
5075    SYNTAX      TmnxSETSRefSource
5076    MAX-ACCESS  read-only
5077    STATUS      current
5078    DESCRIPTION
5079        "The value of tmnxSyncIfTimingRefOrder1 indicates the most preferred
5080         timing reference source.
5081
5082         Four different timing input references may be specified in the
5083         reference order ('bits', 'reference1', 'reference2', and 'ptp').
5084
5085         The synchronous equipment timing subsystem chooses a reference based
5086         on priority."
5087    ::= { tmnxSyncIfTimingEntry 2 }
5088
5089tmnxSyncIfTimingRefOrder2      OBJECT-TYPE
5090    SYNTAX      TmnxSETSRefSource
5091    MAX-ACCESS  read-only
5092    STATUS      current
5093    DESCRIPTION
5094        "The value of tmnxSyncIfTimingRefOrder2 indicates the second most
5095          preferred timing reference for the synchronous equipment timing
5096          subsystem."
5097    ::= { tmnxSyncIfTimingEntry 3 }
5098
5099tmnxSyncIfTimingRef1SrcPort      OBJECT-TYPE
5100    SYNTAX      TmnxPortID
5101    MAX-ACCESS  read-only
5102    STATUS      current
5103    DESCRIPTION
5104        "The value of tmnxSyncIfTimingRef1SrcPort indicates the source port of
5105         the first timing reference.
5106
5107         A value of '1e000000'H indicates that there is no source port for this
5108         reference."
5109    ::= { tmnxSyncIfTimingEntry 4 }
5110
5111tmnxSyncIfTimingRef1AdminStatus      OBJECT-TYPE
5112    SYNTAX      TmnxPortAdminStatus
5113    MAX-ACCESS  read-only
5114    STATUS      current
5115    DESCRIPTION
5116        "The value of tmnxSyncIfTimingRef1AdminStatus indicates the
5117         administrative status of the first timing reference."
5118    ::= { tmnxSyncIfTimingEntry 5 }
5119
5120tmnxSyncIfTimingRef1InUse      OBJECT-TYPE
5121    SYNTAX      TruthValue
5122    MAX-ACCESS  read-only
5123    STATUS      current
5124    DESCRIPTION
5125        "The value of tmnxSyncIfTimingRef1InUse indicates whether the first
5126         timing reference is presently being used by the synchronous timing
5127         subsystem.  If it is in use, tmnxSyncIfTimingFreqOffset indicates
5128         the frequency offset for this reference."
5129    ::= { tmnxSyncIfTimingEntry 6 }
5130
5131tmnxSyncIfTimingRef1Qualified      OBJECT-TYPE
5132    SYNTAX      TmnxSETSRefQualified
5133    MAX-ACCESS  read-only
5134    STATUS      current
5135    DESCRIPTION
5136        "The value of tmnxSyncIfTimingRef1Qualified indicates whether the first
5137         timing reference is qualified for use by the synchronous timing
5138         subsystem.  If tmnxSyncIfTimingRef1Qualified is set to 'not-qualified',
5139         then the object tmnxSyncIfTimingRef1Alarm gives the reason for
5140         disqualification."
5141    ::= { tmnxSyncIfTimingEntry 7 }
5142
5143tmnxSyncIfTimingRef1Alarm      OBJECT-TYPE
5144    SYNTAX      TmnxSETSRefAlarm
5145    MAX-ACCESS  read-only
5146    STATUS      current
5147    DESCRIPTION
5148        "The value of tmnxSyncIfTimingRef1Alarm indicates the alarms on the
5149         first reference.  If any of the bits is set to '1', then the first
5150         reference is disqualified by the timing subsystem and the value of
5151         tmnxSyncIfTimingRef1Qualified is set to 'not-qualified'.
5152         los    - loss of signal
5153         oof    - out of frequency range
5154         oopir  - out of pull in range
5155        "
5156    ::= { tmnxSyncIfTimingEntry 8 }
5157
5158tmnxSyncIfTimingRef2SrcPort      OBJECT-TYPE
5159    SYNTAX      TmnxPortID
5160    MAX-ACCESS  read-only
5161    STATUS      current
5162    DESCRIPTION
5163        "The value of tmnxSyncIfTimingRef2SrcPort indicates the source port of
5164         the second timing reference.
5165
5166         A value of '1e000000'H indicates that there is no source port for this
5167         reference."
5168    ::= { tmnxSyncIfTimingEntry 9 }
5169
5170tmnxSyncIfTimingRef2AdminStatus      OBJECT-TYPE
5171    SYNTAX      TmnxPortAdminStatus
5172    MAX-ACCESS  read-only
5173    STATUS      current
5174    DESCRIPTION
5175        "The value of tmnxSyncIfTimingRef2AdminStatus indicates the
5176         administrative status of the second timing reference."
5177    ::= { tmnxSyncIfTimingEntry 10 }
5178
5179tmnxSyncIfTimingRef2InUse      OBJECT-TYPE
5180    SYNTAX      TruthValue
5181    MAX-ACCESS  read-only
5182    STATUS      current
5183    DESCRIPTION
5184        "The value of tmnxSyncIfTimingRef2InUse indicates whether the second
5185         timing reference is presently being used by the synchronous timing
5186         subsystem."
5187    ::= { tmnxSyncIfTimingEntry 11 }
5188
5189tmnxSyncIfTimingRef2Qualified      OBJECT-TYPE
5190    SYNTAX      TmnxSETSRefQualified
5191    MAX-ACCESS  read-only
5192    STATUS      current
5193    DESCRIPTION
5194        "The value of tmnxSyncIfTimingRef2Qualified indicates whether the
5195         second timing reference is qualified for use by the synchronous
5196         timing subsystem.  If tmnxSyncIfTimingRef2Qualified is 'not-qualified'
5197         then the object tmnxSyncIfTimingRef2Alarm gives the reason for
5198         disqualification."
5199    ::= { tmnxSyncIfTimingEntry 12 }
5200
5201tmnxSyncIfTimingRef2Alarm      OBJECT-TYPE
5202    SYNTAX      TmnxSETSRefAlarm
5203    MAX-ACCESS  read-only
5204    STATUS      current
5205    DESCRIPTION
5206        "The value of tmnxSyncIfTimingRef2Alarm indicates the alarms on the
5207         second reference.  If any of the bits is set to '1', then the second
5208         reference is disqualified by the timing subsystem and the value of
5209         tmnxSyncIfTimingRef2Qualified is set to 'not-qualified'.
5210         los    - loss of signal
5211         oof    - out of frequency range
5212         oopir  - out of pull in range
5213        "
5214    ::= { tmnxSyncIfTimingEntry 13 }
5215
5216tmnxSyncIfTimingFreqOffset      OBJECT-TYPE
5217    SYNTAX      Integer32
5218    UNITS       "parts-per-million"
5219    MAX-ACCESS  read-only
5220    STATUS      current
5221    DESCRIPTION
5222        "The value of tmnxSyncIfTimingFreqOffset indicates the frequency offset
5223         of the current selected timing reference in parts per million (ppm)."
5224    ::= { tmnxSyncIfTimingEntry 14 }
5225
5226tmnxSyncIfTimingStatus      OBJECT-TYPE
5227    SYNTAX      INTEGER
5228                {
5229                    not-present (1),
5230                    master-freerun (2),
5231                    master-holdover (3),
5232                    master-locked (4),
5233                    slave (5),
5234                    acquiring (6)
5235                }
5236    MAX-ACCESS  read-only
5237    STATUS      current
5238    DESCRIPTION
5239        "The value of tmnxSyncIfTimingStatus indicates the present status of
5240         the synchronous timing equipment subsystem (SETS)."
5241    ::= { tmnxSyncIfTimingEntry 15 }
5242
5243tmnxSyncIfTimingRefOrder3      OBJECT-TYPE
5244    SYNTAX      TmnxSETSRefSource
5245    MAX-ACCESS  read-only
5246    STATUS      current
5247    DESCRIPTION
5248        "The value of tmnxSyncIfTimingRefOrder3 is the third most preferred
5249         timing reference for the synchronous equipment timing subsystem."
5250    ::= { tmnxSyncIfTimingEntry 16 }
5251
5252tmnxSyncIfTimingBITSIfType      OBJECT-TYPE
5253    SYNTAX      TmnxBITSIfType
5254    MAX-ACCESS  read-only
5255    STATUS      current
5256    DESCRIPTION
5257        "The value of tmnxSyncIfTimingBITSIfType indicates the interface type
5258         of the BITS (Building Integrated Timing Supply) timing reference. It
5259         also indicates the framing type of the interface."
5260    ::= { tmnxSyncIfTimingEntry 17 }
5261
5262tmnxSyncIfTimingBITSAdminStatus      OBJECT-TYPE
5263    SYNTAX      TmnxPortAdminStatus
5264    MAX-ACCESS  read-only
5265    STATUS      current
5266    DESCRIPTION
5267        "The value of tmnxSyncIfTimingBITSAdminStatus indicates administrative
5268         status of the BITS (Building Integrated Timing Supply) input timing
5269         reference."
5270    ::= { tmnxSyncIfTimingEntry 18 }
5271
5272tmnxSyncIfTimingBITSInUse      OBJECT-TYPE
5273    SYNTAX      TruthValue
5274    MAX-ACCESS  read-only
5275    STATUS      current
5276    DESCRIPTION
5277        "The value of tmnxSyncIfTimingBITSInUse indicates whether the BITS
5278         timing reference is presently being used by the synchronous timing
5279         subsystem.  If it is in use, tmnxSyncIfTimingFreqOffset indicates
5280         the frequency offset for this reference."
5281    ::= { tmnxSyncIfTimingEntry 19 }
5282
5283tmnxSyncIfTimingBITSQualified      OBJECT-TYPE
5284    SYNTAX      TmnxSETSRefQualified
5285    MAX-ACCESS  read-only
5286    STATUS      current
5287    DESCRIPTION
5288        "The value of tmnxSyncIfTimingBITSQualified indicates whether the BITS
5289         timing reference is qualified for use by the synchronous timing
5290         subsystem.  If tmnxSyncIfTimingBITSQualified is 'not-qualified', then
5291         the object tmnxSyncIfTimingBITSAlarm gives the reason for
5292         disqualification."
5293    ::= { tmnxSyncIfTimingEntry 20 }
5294
5295tmnxSyncIfTimingBITSAlarm      OBJECT-TYPE
5296    SYNTAX      TmnxSETSRefAlarm
5297    MAX-ACCESS  read-only
5298    STATUS      current
5299    DESCRIPTION
5300        "The value of tmnxSyncIfTimingBITSAlarm indicates the alarms on the
5301         BITS reference.  If any of the bits is set to '1', then the BITS
5302         reference is disqualified by the timing subsystem and the value of
5303         tmnxSyncIfTimingBITSQualified is set to 'not-qualified'."
5304    ::= { tmnxSyncIfTimingEntry 21 }
5305
5306tmnxSyncIfTimingRef1SrcHw      OBJECT-TYPE
5307    SYNTAX      TmnxHwIndexOrZero
5308    MAX-ACCESS  read-only
5309    STATUS      current
5310    DESCRIPTION
5311        "The value of tmnxSyncIfTimingRef1SrcHw indicates the source HW
5312         index of the first timing reference if source is not a port."
5313    ::= { tmnxSyncIfTimingEntry 22 }
5314
5315tmnxSyncIfTimingRef1BITSIfType      OBJECT-TYPE
5316    SYNTAX      TmnxBITSIfType
5317    MAX-ACCESS  read-only
5318    STATUS      current
5319    DESCRIPTION
5320        "The value of tmnxSyncIfTimingRef1BITSIfType indicates the interface
5321         type of the first timing reference if the source is BITS.  It also
5322         indicates the framing type of the interface."
5323    ::= { tmnxSyncIfTimingEntry 23 }
5324
5325tmnxSyncIfTimingRef2SrcHw      OBJECT-TYPE
5326    SYNTAX      TmnxHwIndexOrZero
5327    MAX-ACCESS  read-only
5328    STATUS      current
5329    DESCRIPTION
5330        "The value of tmnxSyncIfTimingRef2SrcHw indicates the source HW
5331         index of the second timing reference if source is not a port."
5332    ::= { tmnxSyncIfTimingEntry 24 }
5333
5334tmnxSyncIfTimingRef2BITSIfType      OBJECT-TYPE
5335    SYNTAX      TmnxBITSIfType
5336    MAX-ACCESS  read-only
5337    STATUS      current
5338    DESCRIPTION
5339        "The value of tmnxSyncIfTimingRef2BITSIfType indicates the interface
5340         type of the second timing reference if the source is BITS. It also
5341         indicates the framing type of the interface."
5342    ::= { tmnxSyncIfTimingEntry 25 }
5343
5344tmnxSyncIfTimingBITSOutAdmStatus OBJECT-TYPE
5345    SYNTAX      TmnxPortAdminStatus
5346    MAX-ACCESS  read-only
5347    STATUS      current
5348    DESCRIPTION
5349        "The value of tmnxSyncIfTimingBITSOutAdmStatus indicates administrative
5350         status of the BITS (Building Integrated Timing Supply) output timing
5351         reference."
5352    ::= { tmnxSyncIfTimingEntry 26 }
5353
5354tmnxSyncIfTimingBITSOutLineLen   OBJECT-TYPE
5355    SYNTAX      INTEGER {
5356                    lengthNotApplicable (0),
5357                    length0To110        (1),
5358                    length110To220      (2),
5359                    length220To330      (3),
5360                    length330To440      (4),
5361                    length440To550      (5),
5362                    length550To660      (6)
5363                }
5364    MAX-ACCESS  read-only
5365    STATUS      current
5366    DESCRIPTION
5367        "tmnxSyncIfTimingBITSOutLineLen indicates the length of the line
5368         (in feet) for the BITS (Building Integrated Timing Supply) output.
5369         The following values are valid:
5370             lengthNotApplicable (0) - When BITS output is not supported
5371             length0To110        (1) - For line length from 0 to 110 feet
5372             length110To220      (2) - For line length from 110 to 220 feet
5373             length220To330      (3) - For line length from 230 to 330 feet
5374             length330To440      (4) - For line length from 330 to 440 feet
5375             length440To550      (5) - For line length from 440 to 550 feet
5376             length550To660      (6) - For line length from 550 to 660 feet
5377         The default is 'lengthNotApplicable' on CPM cards which do not
5378         support line length.  Otherwise, the default is 'length0To110'."
5379    ::= { tmnxSyncIfTimingEntry 27 }
5380
5381tmnxSyncIfTimingRef1CfgQltyLevel OBJECT-TYPE
5382    SYNTAX      TmnxSSMQualityLevel
5383    MAX-ACCESS  read-only
5384    STATUS      current
5385    DESCRIPTION
5386        "The value of tmnxSyncIfTimingRef1CfgQltyLevel indicates the configured
5387         Quality Level of Reference 1. A value of 'unknown (0)' indicates
5388         Reference 1 is not forced to a specific quality level."
5389    ::= { tmnxSyncIfTimingEntry 28 }
5390
5391tmnxSyncIfTimingRef1RxQltyLevel  OBJECT-TYPE
5392    SYNTAX      TmnxSSMQualityLevel
5393    MAX-ACCESS  read-only
5394    STATUS      current
5395    DESCRIPTION
5396        "The value of tmnxSyncIfTimingRef1RxQltyLevel indicates the received
5397         SSM Quality Level of Reference 1."
5398    ::= { tmnxSyncIfTimingEntry 29 }
5399
5400tmnxSyncIfTimingRef2CfgQltyLevel OBJECT-TYPE
5401    SYNTAX      TmnxSSMQualityLevel
5402    MAX-ACCESS  read-only
5403    STATUS      current
5404    DESCRIPTION
5405        "The value of tmnxSyncIfTimingRef2CfgQltyLevel indicates the configured
5406         Quality Level of Reference 2. A value of 'unknown (0)' indicates
5407         Reference 2 is not forced to a specific quality level."
5408    ::= { tmnxSyncIfTimingEntry 30 }
5409
5410tmnxSyncIfTimingRef2RxQltyLevel  OBJECT-TYPE
5411    SYNTAX      TmnxSSMQualityLevel
5412    MAX-ACCESS  read-only
5413    STATUS      current
5414    DESCRIPTION
5415        "The value of tmnxSyncIfTimingRef2RxQltyLevel indicates the received
5416         SSM Quality Level of Reference 2."
5417    ::= { tmnxSyncIfTimingEntry 31 }
5418
5419tmnxSyncIfTimingBITSCfgQltyLevel OBJECT-TYPE
5420    SYNTAX      TmnxSSMQualityLevel
5421    MAX-ACCESS  read-only
5422    STATUS      current
5423    DESCRIPTION
5424        "The value of tmnxSyncIfTimingBITSCfgQltyLevel indicates the configured
5425         Quality Level of the BITS interface. A value of 'unknown (0)'
5426         indicates the BITS interface is not forced to a specific quality
5427         level."
5428    ::= { tmnxSyncIfTimingEntry 32 }
5429
5430tmnxSyncIfTimingBITSRxQltyLevel  OBJECT-TYPE
5431    SYNTAX      TmnxSSMQualityLevel
5432    MAX-ACCESS  read-only
5433    STATUS      current
5434    DESCRIPTION
5435        "The value of tmnxSyncIfTimingBITSRxQltyLevel indicates the received
5436         SSM Quality Level of the BITS interface."
5437    ::= { tmnxSyncIfTimingEntry 33 }
5438
5439tmnxSyncIfTimingBITS2InUse       OBJECT-TYPE
5440    SYNTAX      TruthValue
5441    MAX-ACCESS  read-only
5442    STATUS      current
5443    DESCRIPTION
5444        "The value of tmnxSyncIfTimingBITS2InUse indicates whether the BITS2
5445         timing reference is presently being used by the synchronous timing
5446         subsystem.  If it is in use, tmnxSyncIfTimingFreqOffset indicates
5447         the frequency offset for this reference."
5448    ::= { tmnxSyncIfTimingEntry 34 }
5449
5450tmnxSyncIfTimingBITS2Qualified   OBJECT-TYPE
5451    SYNTAX      TmnxSETSRefQualified
5452    MAX-ACCESS  read-only
5453    STATUS      current
5454    DESCRIPTION
5455        "The value of tmnxSyncIfTimingBITS2Qualified indicates whether the BITS2
5456         timing reference is qualified for use by the synchronous timing
5457         subsystem.  If tmnxSyncIfTimingBITS2Qualified is 'not-qualified', then
5458         the object tmnxSyncIfTimingBITS2Alarm gives the reason for
5459         disqualification."
5460    ::= { tmnxSyncIfTimingEntry 35 }
5461
5462tmnxSyncIfTimingBITS2Alarm       OBJECT-TYPE
5463    SYNTAX      TmnxSETSRefAlarm
5464    MAX-ACCESS  read-only
5465    STATUS      current
5466    DESCRIPTION
5467        "The value of tmnxSyncIfTimingBITS2Alarm indicates the alarms on the
5468         BITS2 reference.  If any of the bits is set to '1', then the BITS2
5469         reference is disqualified by the timing subsystem and the value of
5470         tmnxSyncIfTimingBITSQualified is set to 'not-qualified'."
5471    ::= { tmnxSyncIfTimingEntry 36 }
5472
5473tmnxSyncIfTimingBITS2RxQltyLevel OBJECT-TYPE
5474    SYNTAX      TmnxSSMQualityLevel
5475    MAX-ACCESS  read-only
5476    STATUS      current
5477    DESCRIPTION
5478        "The value of tmnxSyncIfTimingBITS2RxQltyLevel indicates the received
5479         SSM Rx Quality Level of the BITS2 interface."
5480    ::= { tmnxSyncIfTimingEntry 37 }
5481
5482tmnxSyncIfTimingRef1State        OBJECT-TYPE
5483    SYNTAX      TmnxRefInState
5484    MAX-ACCESS  read-only
5485    STATUS      current
5486    DESCRIPTION
5487        "The value of tmnxSyncIfTimingRef1State indicates the operational state
5488         of the Reference 1 Timing."
5489    ::= { tmnxSyncIfTimingEntry 38 }
5490
5491tmnxSyncIfTimingRef2State        OBJECT-TYPE
5492    SYNTAX      TmnxRefInState
5493    MAX-ACCESS  read-only
5494    STATUS      current
5495    DESCRIPTION
5496        "The value of tmnxSyncIfTimingRef2State indicates the operational state
5497         of the Reference 2 Timing."
5498    ::= { tmnxSyncIfTimingEntry 39 }
5499
5500tmnxSyncIfTimingBITSState        OBJECT-TYPE
5501    SYNTAX      TmnxRefInState
5502    MAX-ACCESS  read-only
5503    STATUS      current
5504    DESCRIPTION
5505        "The value of tmnxSyncIfTimingBITSState indicates the operational state
5506         of the BITS Timing Interface."
5507    ::= { tmnxSyncIfTimingEntry 40 }
5508
5509tmnxSyncIfTimingBITS2State       OBJECT-TYPE
5510    SYNTAX      TmnxRefInState
5511    MAX-ACCESS  read-only
5512    STATUS      current
5513    DESCRIPTION
5514        "The value of tmnxSyncIfTimingBITS2State indicates the operational state
5515         of the BITS2 Timing Interface."
5516    ::= { tmnxSyncIfTimingEntry 41 }
5517
5518tmnxSyncIfTimingRef1NationalUse  OBJECT-TYPE
5519    SYNTAX      Unsigned32 (4..8)
5520    MAX-ACCESS  read-only
5521    STATUS      current
5522    DESCRIPTION
5523        "The value of tmnxSyncIfTimingRef1NationalUse indicates the national use
5524         bit to carry SSM Messages. This applies only to E1 BITS interfaces."
5525    DEFVAL { 8 }
5526    ::= { tmnxSyncIfTimingEntry 42 }
5527
5528tmnxSyncIfTimingRef2NationalUse  OBJECT-TYPE
5529    SYNTAX      Unsigned32 (4..8)
5530    MAX-ACCESS  read-only
5531    STATUS      current
5532    DESCRIPTION
5533        "The value of tmnxSyncIfTimingRef2NationalUse indicates the national use
5534         bit to carry SSM Messages. This applies only to E1 BITS interfaces."
5535    DEFVAL { 8 }
5536    ::= { tmnxSyncIfTimingEntry 43 }
5537
5538tmnxSyncIfTimingBITSNationalUse  OBJECT-TYPE
5539    SYNTAX      Unsigned32 (4..8)
5540    MAX-ACCESS  read-only
5541    STATUS      current
5542    DESCRIPTION
5543        "The value of tmnxSyncIfTimingBITSNationalUse indicates the national use
5544         bit to carry SSM Messages. This applies only to E1 BITS interfaces."
5545    DEFVAL { 8 }
5546    ::= { tmnxSyncIfTimingEntry 44 }
5547
5548tmnxSyncIfTimingQLSelection      OBJECT-TYPE
5549    SYNTAX      TmnxEnabledDisabled
5550    MAX-ACCESS  read-only
5551    STATUS      current
5552    DESCRIPTION
5553        "The value of tmnxSyncIfTimingQLSelection indicates whether or not the
5554         timing reference selection process uses the quality level of each
5555         timing reference when making the decision on which reference should
5556         provide system timing."
5557    REFERENCE "ITU-T Recommendation G.781, June 1999, Section 5.12"
5558    ::= { tmnxSyncIfTimingEntry 45 }
5559
5560tmnxSyncIfTimingOtherCPMInUse    OBJECT-TYPE
5561    SYNTAX      TruthValue
5562    MAX-ACCESS  read-only
5563    STATUS      current
5564    DESCRIPTION
5565        "The value of tmnxSyncIfTimingOtherCPMInUse indicates whether the
5566         timing reference from the other CPM is presently being used by the
5567         synchronous timing subsystem on the this CPM."
5568    DEFVAL { false }
5569    ::= { tmnxSyncIfTimingEntry 46 }
5570
5571tmnxSyncIfTimingOtherCPMQual     OBJECT-TYPE
5572    SYNTAX      TmnxSETSRefQualified
5573    MAX-ACCESS  read-only
5574    STATUS      current
5575    DESCRIPTION
5576        "The value of tmnxSyncIfTimingOtherCPMQual indicates whether the
5577         timing reference from the other CPM is qualified for use by the
5578         synchronous timing subsystem on the local CPM.  If
5579         tmnxSyncIfTimingOtherCPMQual is 'not-qualified', then the object
5580         tmnxSyncIfTimingOtherCPMAlarm gives the reason for disqualification."
5581    DEFVAL { not-qualified }
5582    ::= { tmnxSyncIfTimingEntry 47 }
5583
5584tmnxSyncIfTimingOtherCPMAlarm    OBJECT-TYPE
5585    SYNTAX      TmnxSETSRefAlarm
5586    MAX-ACCESS  read-only
5587    STATUS      current
5588    DESCRIPTION
5589        "The value of tmnxSyncIfTimingOtherCPMAlarm indicates the alarms on the
5590         timing reference from the other CPM.  If any of the bits is set to
5591         '1', then the reference is disqualified by the timing subsystem and the
5592         value of tmnxSyncIfTimingOtherCPMQual is set to 'not-qualified'."
5593    DEFVAL { { } }
5594    ::= { tmnxSyncIfTimingEntry 48 }
5595
5596tmnxSyncIfTimingOtherCPMState    OBJECT-TYPE
5597    SYNTAX      TmnxRefInState
5598    MAX-ACCESS  read-only
5599    STATUS      current
5600    DESCRIPTION
5601        "The value of tmnxSyncIfTimingOtherCPMState indicates the operational
5602         state of the timing reference from the other CPM on the local CPM."
5603    DEFVAL { disabled }
5604    ::= { tmnxSyncIfTimingEntry 49 }
5605
5606tmnxSyncIfTimingBITSOutRefSel    OBJECT-TYPE
5607    SYNTAX      TmnxSETSRefSource
5608    MAX-ACCESS  read-only
5609    STATUS      current
5610    DESCRIPTION
5611        "The value of tmnxSyncIfTimingBITSOutRefSel indicates the reference
5612         source for BITS output."
5613    DEFVAL { noReference }
5614    ::= { tmnxSyncIfTimingEntry 50 }
5615
5616tmnxSyncIfTimingBITSTxQltyLevel  OBJECT-TYPE
5617    SYNTAX      TmnxSSMQualityLevel
5618    MAX-ACCESS  read-only
5619    STATUS      current
5620    DESCRIPTION
5621        "The value of tmnxSyncIfTimingBITSTxQltyLevel indicates the transmitted
5622         SSM Tx Quality Level of the BITS interface."
5623    ::= { tmnxSyncIfTimingEntry 51 }
5624
5625tmnxSyncIfTimingBITS2AdminStatus OBJECT-TYPE
5626    SYNTAX      TmnxPortAdminStatus
5627    MAX-ACCESS  read-only
5628    STATUS      current
5629    DESCRIPTION
5630        "The value of tmnxSyncIfTimingBITS2AdminStatus indicates administrative
5631         status of the BITS2 (Building Integrated Timing Supply) input timing
5632         reference."
5633    ::= { tmnxSyncIfTimingEntry 52 }
5634
5635tmnxSyncIfTimingSystemQltyLevel  OBJECT-TYPE
5636    SYNTAX      TmnxSSMQualityLevel
5637    MAX-ACCESS  read-only
5638    STATUS      current
5639    DESCRIPTION
5640        "The value of tmnxSyncIfTimingSystemQltyLevel indicates the quality
5641         level of the system timing reference.  This is normally the quality
5642         level of the selected timing reference.  If no timing reference has
5643         been selected, it indicates the freerun/holdover quality of the
5644         system."
5645    ::= { tmnxSyncIfTimingEntry 53 }
5646
5647tmnxSyncIfTimingRefOrder4      OBJECT-TYPE
5648    SYNTAX      TmnxSETSRefSource
5649    MAX-ACCESS  read-only
5650    STATUS      current
5651    DESCRIPTION
5652        "The value of tmnxSyncIfTimingRefOrder4 is the fourth most preferred
5653         timing reference for the synchronous equipment timing subsystem."
5654    ::= { tmnxSyncIfTimingEntry 54 }
5655
5656tmnxSyncIfTimingPTPAdminStatus   OBJECT-TYPE
5657    SYNTAX      TmnxPortAdminStatus
5658    MAX-ACCESS  read-only
5659    STATUS      current
5660    DESCRIPTION
5661        "The value of tmnxSyncIfTimingPTPAdminStatus indicates the
5662         administrative status of the Precision Timing Protocol (PTP) timing
5663         reference."
5664    ::= { tmnxSyncIfTimingEntry 55 }
5665
5666tmnxSyncIfTimingPTPInUse         OBJECT-TYPE
5667    SYNTAX      TruthValue
5668    MAX-ACCESS  read-only
5669    STATUS      current
5670    DESCRIPTION
5671        "The value of tmnxSyncIfTimingPTPInUse indicates whether the Precision
5672         Timing Protocol (PTP) timing reference is presently being used by the
5673         synchronous timing subsystem.  If it is in use,
5674         tmnxSyncIfTimingFreqOffset indicates the frequency offset for this
5675         reference."
5676    ::= { tmnxSyncIfTimingEntry 56 }
5677
5678tmnxSyncIfTimingPTPQualified     OBJECT-TYPE
5679    SYNTAX      TmnxSETSRefQualified
5680    MAX-ACCESS  read-only
5681    STATUS      current
5682    DESCRIPTION
5683        "The value of tmnxSyncIfTimingPTPQualified indicates whether the
5684         Precision Timing Protocol (PTP) timing reference is qualified for use
5685         by the synchronous timing subsystem.  If tmnxSyncIfTimingPTPQualified
5686         is set to 'not-qualified', then the object tmnxSyncIfTimingPTPAlarm
5687         gives the reason for the disqualification."
5688    ::= { tmnxSyncIfTimingEntry 57 }
5689
5690tmnxSyncIfTimingPTPAlarm         OBJECT-TYPE
5691    SYNTAX      TmnxSETSRefAlarm
5692    MAX-ACCESS  read-only
5693    STATUS      current
5694    DESCRIPTION
5695        "The value of tmnxSyncIfTimingPTPAlarm indicates the alarms on the
5696         Precision Timing Protocol (PTP) reference.  If any of the bits is set
5697         to '1', then the PTP reference is disqualified by the timing subsystem
5698         and the value of tmnxSyncIfTimingPTPQualified is set to
5699         'not-qualified'.
5700         los     - loss of signal
5701         oof     - out of frequency range
5702         oopir   - out of pull in range
5703        "
5704    ::= { tmnxSyncIfTimingEntry 58 }
5705
5706tmnxSyncIfTimingPTPCfgQltyLevel  OBJECT-TYPE
5707    SYNTAX      TmnxSSMQualityLevel
5708    MAX-ACCESS  read-only
5709    STATUS      current
5710    DESCRIPTION
5711        "The value of tmnxSyncIfTimingPTPCfgQltyLevel indicates the configured
5712         Quality Level of Precision Timing Protocol (PTP).  A value of
5713         'unknown (0)' indicates PTP is not forced to a specific quality level."
5714    ::= { tmnxSyncIfTimingEntry 59 }
5715
5716tmnxSyncIfTimingPTPRxQltyLevel   OBJECT-TYPE
5717    SYNTAX      TmnxSSMQualityLevel
5718    MAX-ACCESS  read-only
5719    STATUS      current
5720    DESCRIPTION
5721        "The value of tmnxSyncIfTimingPTPRxQltyLevel indicates the received SSM
5722         RX Quality Level of the Precision Timing Protocol (PTP)."
5723    ::= { tmnxSyncIfTimingEntry 60 }
5724
5725tmnxSyncIfTimingPTPState         OBJECT-TYPE
5726    SYNTAX      TmnxRefInState
5727    MAX-ACCESS  read-only
5728    STATUS      current
5729    DESCRIPTION
5730        "The value of tmnxSyncIfTimingPTPState indicates the operational state
5731         of the Precision Timing Protocol (PTP) Timing."
5732    ::= { tmnxSyncIfTimingEntry 61 }
5733
5734tmnxSyncIfTimingBITSOutSource    OBJECT-TYPE
5735    SYNTAX      TmnxBITSOutSource
5736    MAX-ACCESS  read-only
5737    STATUS      current
5738    DESCRIPTION
5739        "The value of tmnxSyncIfTimingBITSOutSource indicates the source of the
5740         BITS (Building Integrated Timing Supply) output."
5741    ::= { tmnxSyncIfTimingEntry 62 }
5742
5743tmnxSyncIfTimingRefOrder5      OBJECT-TYPE
5744    SYNTAX      TmnxSETSRefSource
5745    MAX-ACCESS  read-only
5746    STATUS      current
5747    DESCRIPTION
5748        "The value of tmnxSyncIfTimingRefOrder5 is the fifth most preferred
5749         timing reference for the synchronous equipment timing subsystem."
5750    ::= { tmnxSyncIfTimingEntry 70 }
5751
5752tmnxSyncIfTimingBITS2InAdminStatus      OBJECT-TYPE
5753    SYNTAX      TmnxPortAdminStatus
5754    MAX-ACCESS  read-only
5755    STATUS      current
5756    DESCRIPTION
5757        "The value of tmnxSyncIfTimingBITS2InAdminStatus indicates administrative
5758         status of the BITS (Building Integrated Timing Supply) input timing
5759         reference."
5760    ::= { tmnxSyncIfTimingEntry 71 }
5761
5762tmnxSyncIfTimingBITS2OutAdminStatus      OBJECT-TYPE
5763    SYNTAX      TmnxPortAdminStatus
5764    MAX-ACCESS  read-only
5765    STATUS      current
5766    DESCRIPTION
5767        "The value of tmnxSyncIfTimingBITS2OutAdminStatus indicates administrative
5768         status of the BITS (Building Integrated Timing Supply) input timing
5769         reference."
5770    ::= { tmnxSyncIfTimingEntry 72 }
5771
5772tmnxSyncIfTimingBITS2TxQltyLevel OBJECT-TYPE
5773    SYNTAX      TmnxSSMQualityLevel
5774    MAX-ACCESS  read-only
5775    STATUS      current
5776    DESCRIPTION
5777        "The value of tmnxSyncIfTimingBITS2TxQltyLevel indicates the received
5778         SSM Rx Quality Level of the BITS2 interface."
5779    ::= { tmnxSyncIfTimingEntry 73 }
5780
5781--
5782-- Administrative value objects
5783--
5784tmnxChassisAdminCtrlObjs  OBJECT IDENTIFIER ::= { tmnxChassisAdminObjects 1 }
5785tmnxChassisAdminValueObjs OBJECT IDENTIFIER ::= { tmnxChassisAdminObjects 2 }
5786
5787--
5788-- Admin Synchoronous Interface Timing table
5789--
5790
5791tSyncIfTimingAdmTable OBJECT-TYPE
5792    SYNTAX  SEQUENCE OF TSyncIfTimingAdmEntry
5793    MAX-ACCESS  not-accessible
5794    STATUS      current
5795    DESCRIPTION
5796        "Values for the synchronous interface timing for the chassis."
5797    ::= { tmnxChassisAdminValueObjs 1 }
5798
5799tSyncIfTimingAdmEntry    OBJECT-TYPE
5800    SYNTAX      TSyncIfTimingAdmEntry
5801    MAX-ACCESS  not-accessible
5802    STATUS      current
5803    DESCRIPTION
5804       "Information about the synchronous interface timing.
5805        Entries are created by user.
5806        Entries are deleted by user.
5807        Note that the first Alcatel-Lucent SROS series product release does
5808        not support configuration of synchronous timing equipment on the
5809        secondary CPM. All SNMP operations with tmnxCpmCardSlotNum of the
5810        secondary CPM will be denied.
5811
5812        The 7x50 systems supports 3 timing references (reference1, reference2
5813        and bits).
5814
5815        The 7710 system only supports 2 timing references (reference1 and
5816        reference2).  On 7710 system, references can be a source port
5817        or a BITS input on a CES CMA.  If the value of the reference source
5818        port is a valid Port ID then the reference is a source port.  If the
5819        value of the source hardware is a valid HWIndex of a CES CMA then the
5820        source is a BITS on the CES CMA."
5821    INDEX       { tmnxChassisIndex, tmnxCpmCardSlotNum, tmnxCpmCardNum }
5822    ::= { tSyncIfTimingAdmTable 1 }
5823
5824TSyncIfTimingAdmEntry            ::= SEQUENCE {
5825    tSyncIfTimingAdmRevert           TruthValue,
5826    tSyncIfTimingAdmRefOrder1        TmnxSETSRefSource,
5827    tSyncIfTimingAdmRefOrder2        TmnxSETSRefSource,
5828    tSyncIfTimingAdmRef1SrcPort      TmnxPortID,
5829    tSyncIfTimingAdmRef1AdminStatus  TmnxPortAdminStatus,
5830    tSyncIfTimingAdmRef2SrcPort      TmnxPortID,
5831    tSyncIfTimingAdmRef2AdminStatus  TmnxPortAdminStatus,
5832    tSyncIfTimingAdmChanged          Unsigned32,
5833    tSyncIfTimingAdmRefOrder3        TmnxSETSRefSource,
5834    tSyncIfTimingAdmBITSIfType       TmnxBITSIfType,
5835    tSyncIfTimingAdmBITSAdminStatus  TmnxPortAdminStatus,
5836    tSyncIfTimingAdmRef1SrcHw        TmnxHwIndexOrZero,
5837    tSyncIfTimingAdmRef1BITSIfType   TmnxBITSIfType,
5838    tSyncIfTimingAdmRef2SrcHw        TmnxHwIndexOrZero,
5839    tSyncIfTimingAdmRef2BITSIfType   TmnxBITSIfType,
5840    tSyncIfTimingAdmBITSOutAdmStatus TmnxPortAdminStatus,
5841    tSyncIfTimingAdmBITSOutLineLen   INTEGER,
5842    tSyncIfTimingAdmRef1CfgQltyLevel TmnxSSMQualityLevel,
5843    tSyncIfTimingAdmRef2CfgQltyLevel TmnxSSMQualityLevel,
5844    tSyncIfTimingAdmBITSCfgQltyLevel TmnxSSMQualityLevel,
5845    tSyncIfTimingAdmRef1NationalUse  Unsigned32,
5846    tSyncIfTimingAdmRef2NationalUse  Unsigned32,
5847    tSyncIfTimingAdmBITSNationalUse  Unsigned32,
5848    tSyncIfTimingAdmQLSelection      TmnxEnabledDisabled,
5849    tSyncIfTimingAdmRefOrder4        TmnxSETSRefSource,
5850    tSyncIfTimingAdmPTPAdminStatus   TmnxPortAdminStatus,
5851    tSyncIfTimingAdmPTPCfgQltyLevel  TmnxSSMQualityLevel,
5852    tSyncIfTimingAdmBITSOutSource    TmnxBITSOutSource,
5853    tSyncIfTimingAdmRefOrder5        TmnxSETSRefSource,
5854    tSyncIfTimingAdmBITS2InAdminStatus   TmnxPortAdminStatus,
5855    tSyncIfTimingAdmBITS2OutAdminStatus  TmnxPortAdminStatus
5856}
5857
5858tSyncIfTimingAdmRevert      OBJECT-TYPE
5859    SYNTAX      TruthValue
5860    MAX-ACCESS  read-create
5861    STATUS      current
5862    DESCRIPTION
5863        "The value of tSyncIfTimingAdmRevert specifies whether the reference
5864         source will revert to a higher priority source that has been
5865         re-validated or newly validated.
5866
5867         The synchronous interface timing subsystem is by default non-revertive
5868         ('false')."
5869    DEFVAL { false }
5870    ::= { tSyncIfTimingAdmEntry 1 }
5871
5872tSyncIfTimingAdmRefOrder1      OBJECT-TYPE
5873    SYNTAX      TmnxSETSRefSource
5874    MAX-ACCESS  read-create
5875    STATUS      current
5876    DESCRIPTION
5877        "The value of tSyncIfTimingAdmRefOrder1 specifies the most preferred
5878         timing reference source.
5879
5880         The synchronous equipment timing subsystem chooses a timing reference
5881         based on priority.
5882
5883         The user can configure the priority order of the following timing
5884         reference inputs ('bits', 'reference1', 'reference2', and 'ptp').
5885
5886         If the platform does not support that timing reference input, it
5887         cannot be configured in the reference priority order.  For example,
5888         the 'bits' timing reference cannot be configured on a 7750 SR-c12
5889         system.
5890
5891         Other values of TmnxSETSRefSource (e.g. 'bits2') cannot be configured
5892         in the reference order."
5893    DEFVAL { bits1 }
5894    ::= { tSyncIfTimingAdmEntry 2 }
5895
5896tSyncIfTimingAdmRefOrder2      OBJECT-TYPE
5897    SYNTAX      TmnxSETSRefSource
5898    MAX-ACCESS  read-create
5899    STATUS      current
5900    DESCRIPTION
5901        "The value of tSyncIfTimingAdmRefOrder2 specifies the second most
5902         preferred timing reference for the synchronous equipment timing
5903         subsystem."
5904    DEFVAL { reference1 }
5905    ::= { tSyncIfTimingAdmEntry 3 }
5906
5907tSyncIfTimingAdmRef1SrcPort      OBJECT-TYPE
5908    SYNTAX      TmnxPortID
5909    MAX-ACCESS  read-create
5910    STATUS      current
5911    DESCRIPTION
5912        "The value of tSyncIfTimingAdmRef1SrcPort specifies the source port
5913         of the first timing reference.
5914
5915         This can only be set to a valid TmnxPortID if the value of
5916         tSyncIfTimingAdmRef1SrcHw is 0."
5917    DEFVAL { '1e000000'H }
5918    ::= { tSyncIfTimingAdmEntry 4 }
5919
5920tSyncIfTimingAdmRef1AdminStatus      OBJECT-TYPE
5921    SYNTAX      TmnxPortAdminStatus
5922    MAX-ACCESS  read-create
5923    STATUS      current
5924    DESCRIPTION
5925        "The value of tSyncIfTimingAdmRef1AdminStatus specifies the desired
5926         administrative status of the first timing reference."
5927    DEFVAL { outOfService }
5928    ::= { tSyncIfTimingAdmEntry 5 }
5929
5930tSyncIfTimingAdmRef2SrcPort      OBJECT-TYPE
5931    SYNTAX      TmnxPortID
5932    MAX-ACCESS  read-create
5933    STATUS      current
5934    DESCRIPTION
5935        "The value of tSyncIfTimingAdmRef2SrcPort specifies the source port
5936         of the second timing reference.
5937
5938         This can only be set to a valid TmnxPortID if the value of
5939         tSyncIfTimingAdmRef2SrcHw is 0."
5940    DEFVAL { '1e000000'H }
5941    ::= { tSyncIfTimingAdmEntry 6 }
5942
5943tSyncIfTimingAdmRef2AdminStatus      OBJECT-TYPE
5944    SYNTAX      TmnxPortAdminStatus
5945    MAX-ACCESS  read-create
5946    STATUS      current
5947    DESCRIPTION
5948        "The value of tSyncIfTimingAdmRef2AdminStatus specifies the desired
5949         administrative status of the second timing reference."
5950    DEFVAL { outOfService }
5951    ::= { tSyncIfTimingAdmEntry 7 }
5952
5953tSyncIfTimingAdmChanged      OBJECT-TYPE
5954    SYNTAX      Unsigned32
5955    MAX-ACCESS  read-create
5956    STATUS      current
5957    DESCRIPTION
5958        "The value of tSyncIfTimingAdmChanged is a bitmask that indicates which
5959         objects have been set, but not committed.  bit values used here are:
5960
5961         0x0001:    tSyncIfTimingAdmRevert
5962         0x0002:    tSyncIfTimingAdmRefOrder1
5963         0x0004:    tSyncIfTimingAdmRefOrder2
5964         0x0008:    tSyncIfTimingAdmRef1SrcPort
5965         0x0010:    tSyncIfTimingAdmRef1AdminStatus
5966         0x0020:    tSyncIfTimingAdmRef2SrcPort
5967         0x0040:    tSyncIfTimingAdmRef2AdminStatus
5968         0x0080:    tSyncIfTimingAdmRefOrder3
5969         0x0100:    tSyncIfTimingAdmBITSIfType
5970         0x0200:    tSyncIfTimingAdmBITSAdminStatus
5971         0x0400:    tSyncIfTimingAdmRef1SrcHw
5972         0x0800:    tSyncIfTimingAdmRef1BITSIfType
5973         0x1000:    tSyncIfTimingAdmRef2SrcHw
5974         0x2000:    tSyncIfTimingAdmRef2BITSIfType
5975
5976         The agent sets these bits when an object in the row
5977         is set.  This object is cleared to zero by setting
5978         tmnxChassisAdminControlApply to initialize(2) or commit(3).
5979        "
5980     ::= { tSyncIfTimingAdmEntry 8 }
5981
5982tSyncIfTimingAdmRefOrder3      OBJECT-TYPE
5983    SYNTAX      TmnxSETSRefSource
5984    MAX-ACCESS  read-create
5985    STATUS      current
5986    DESCRIPTION
5987        "The value of tSyncIfTimingAdmRefOrder3 indicates the third most
5988         preferred timing reference for the synchronous equipment timing
5989         subsystem."
5990    DEFVAL { reference2 }
5991    ::= { tSyncIfTimingAdmEntry 9 }
5992
5993tSyncIfTimingAdmBITSIfType      OBJECT-TYPE
5994    SYNTAX      TmnxBITSIfType
5995    MAX-ACCESS  read-create
5996    STATUS      current
5997    DESCRIPTION
5998        "The value of tSyncIfTimingAdmBITSIfType specifies the interface type
5999         of the BITS (Building Integrated Timing Supply) timing reference."
6000    DEFVAL { t1-esf }
6001    ::= { tSyncIfTimingAdmEntry 10 }
6002
6003tSyncIfTimingAdmBITSAdminStatus      OBJECT-TYPE
6004    SYNTAX      TmnxPortAdminStatus
6005    MAX-ACCESS  read-create
6006    STATUS      current
6007    DESCRIPTION
6008        "The value of tSyncIfTimingAdmBITSAdminStatus specifies the desired
6009         administrative status of the BITS (Building Integrated Timing Supply)
6010         input timing reference."
6011    DEFVAL { outOfService }
6012    ::= { tSyncIfTimingAdmEntry 11 }
6013
6014tSyncIfTimingAdmRef1SrcHw      OBJECT-TYPE
6015    SYNTAX      TmnxHwIndexOrZero
6016    MAX-ACCESS  read-create
6017    STATUS      current
6018    DESCRIPTION
6019        "The value of tSyncIfTimingAdmRef1SrcHw specifies the source HW
6020         Index of the first timing reference if the source is not a port.
6021
6022         This can only be set to a valid HW Index if the value of
6023         tSyncIfTimingAdmRef1SrcPort is '1e000000'H.
6024
6025         Setting the value of tSyncIfTimingAdmRef1SrcHw from non-zero to zero
6026         will cause the value of tSyncIfTimingAdmRef1BITSIfType to be reset to
6027         its default value of 't1-esf'."
6028    DEFVAL { 0 }
6029    ::= { tSyncIfTimingAdmEntry 12 }
6030
6031tSyncIfTimingAdmRef1BITSIfType      OBJECT-TYPE
6032    SYNTAX      TmnxBITSIfType
6033    MAX-ACCESS  read-create
6034    STATUS      current
6035    DESCRIPTION
6036        "The value of tSyncIfTimingAdmRef1BITSIfType specifies the interface
6037         type of the first timing reference if the source is BITS.
6038
6039         This can only be changed if the value of tSyncIfTimingAdmRef1SrcHw
6040         is not 0."
6041    DEFVAL { t1-esf }
6042    ::= { tSyncIfTimingAdmEntry 13 }
6043
6044tSyncIfTimingAdmRef2SrcHw      OBJECT-TYPE
6045    SYNTAX      TmnxHwIndexOrZero
6046    MAX-ACCESS  read-create
6047    STATUS      current
6048    DESCRIPTION
6049        "The value of tSyncIfTimingAdmRef2SrcHw specifies the source HW
6050         Index of the second timing reference if the source is not a port.
6051
6052         This can only be set to a valid HW Index if the value of
6053         tSyncIfTimingAdmRef2SrcPort is '1e000000'H.
6054
6055         Setting the value of tSyncIfTimingAdmRef2SrcHw from non-zero to zero
6056         will cause the value of tSyncIfTimingAdmRef2BITSIfType to be reset to
6057         its default value of 't1-esf'."
6058    DEFVAL { 0 }
6059    ::= { tSyncIfTimingAdmEntry 14 }
6060
6061tSyncIfTimingAdmRef2BITSIfType      OBJECT-TYPE
6062    SYNTAX      TmnxBITSIfType
6063    MAX-ACCESS  read-create
6064    STATUS      current
6065    DESCRIPTION
6066        "The value of tSyncIfTimingAdmRef2BITSIfType specifies the interface
6067         type of the second timing reference if the source is BITS.
6068
6069         This can only be changed if the value of tSyncIfTimingAdmRef2SrcHw
6070         is not 0."
6071    DEFVAL { t1-esf }
6072    ::= { tSyncIfTimingAdmEntry 15 }
6073
6074tSyncIfTimingAdmBITSOutAdmStatus  OBJECT-TYPE
6075    SYNTAX      TmnxPortAdminStatus
6076    MAX-ACCESS  read-create
6077    STATUS      current
6078    DESCRIPTION
6079        "The value of tSyncIfTimingAdmBITSOutAdmStatus specifies administrative
6080         status of the BITS (Building Integrated Timing Supply) output timing
6081         reference."
6082    DEFVAL { outOfService }
6083    ::= { tSyncIfTimingAdmEntry 16 }
6084
6085tSyncIfTimingAdmBITSOutLineLen   OBJECT-TYPE
6086    SYNTAX      INTEGER {
6087                    lengthNotApplicable (0),
6088                    length0To110        (1),
6089                    length110To220      (2),
6090                    length220To330      (3),
6091                    length330To440      (4),
6092                    length440To550      (5),
6093                    length550To660      (6)
6094                }
6095    MAX-ACCESS  read-create
6096    STATUS      current
6097    DESCRIPTION
6098        "tSyncIfTimingAdmBITSOutLineLen specifies the length of the line
6099         (in feet) for the BITS (Building Integrated Timing Supply) output.
6100         The following values are valid:
6101             lengthNotApplicable (0) - When BITS output is not supported
6102             length0To110        (1) - For line length from 0 to 110 feet
6103             length110To220      (2) - For line length from 110 to 220 feet
6104             length220To330      (3) - For line length from 230 to 330 feet
6105             length330To440      (4) - For line length from 330 to 440 feet
6106             length440To550      (5) - For line length from 440 to 550 feet
6107             length550To660      (6) - For line length from 550 to 660 feet
6108         The default is 'lengthNotApplicable' on CPM cards which do not
6109         support line length.  Otherwise, the default is 'length0To110'."
6110    DEFVAL { lengthNotApplicable }
6111    ::= { tSyncIfTimingAdmEntry 17 }
6112
6113tSyncIfTimingAdmRef1CfgQltyLevel OBJECT-TYPE
6114    SYNTAX      TmnxSSMQualityLevel
6115    MAX-ACCESS  read-create
6116    STATUS      current
6117    DESCRIPTION
6118        "The value of tSyncIfTimingAdmRef1CfgQltyLevel specifies the configured
6119         Quality Level of Reference 1. A value of 'unknown (0)' indicates
6120         Reference 1 is not forced to a specific quality level."
6121    DEFVAL { unknown }
6122    ::= { tSyncIfTimingAdmEntry 18 }
6123
6124tSyncIfTimingAdmRef2CfgQltyLevel OBJECT-TYPE
6125    SYNTAX      TmnxSSMQualityLevel
6126    MAX-ACCESS  read-create
6127    STATUS      current
6128    DESCRIPTION
6129        "The value of tSyncIfTimingAdmRef2CfgQltyLevel specifies the configured
6130         Quality Level of Reference 2. A value of 'unknown (0)' indicates
6131         Reference 2 is not forced to a specific quality level."
6132    DEFVAL { unknown }
6133    ::= { tSyncIfTimingAdmEntry 19 }
6134
6135tSyncIfTimingAdmBITSCfgQltyLevel OBJECT-TYPE
6136    SYNTAX      TmnxSSMQualityLevel
6137    MAX-ACCESS  read-create
6138    STATUS      current
6139    DESCRIPTION
6140        "The value of tSyncIfTimingAdmBITSCfgQltyLevel specifies the configured
6141         Quality Level of the BITS interface. A value of 'unknown (0)' indicates
6142         the BITS interface is not forced to a specific quality level."
6143    DEFVAL { unknown }
6144    ::= { tSyncIfTimingAdmEntry 20 }
6145
6146tSyncIfTimingAdmRef1NationalUse  OBJECT-TYPE
6147    SYNTAX      Unsigned32 (4..8)
6148    MAX-ACCESS  read-create
6149    STATUS      current
6150    DESCRIPTION
6151        "The value of tSyncIfTimingAdmRef1NationalUse specifies the national use
6152         bit to carry SSM Messages. This applies only to E1 BITS interfaces."
6153    DEFVAL { 8 }
6154    ::= { tSyncIfTimingAdmEntry 21 }
6155
6156tSyncIfTimingAdmRef2NationalUse  OBJECT-TYPE
6157    SYNTAX      Unsigned32 (4..8)
6158    MAX-ACCESS  read-create
6159    STATUS      current
6160    DESCRIPTION
6161        "The value of tSyncIfTimingAdmRef2NationalUse specifies the national use
6162         bit to carry SSM Messages. This applies only to E1 BITS interfaces."
6163    DEFVAL { 8 }
6164    ::= { tSyncIfTimingAdmEntry 22 }
6165
6166tSyncIfTimingAdmBITSNationalUse  OBJECT-TYPE
6167    SYNTAX      Unsigned32 (4..8)
6168    MAX-ACCESS  read-create
6169    STATUS      current
6170    DESCRIPTION
6171        "The value of tSyncIfTimingAdmBITSNationalUse specifies the national use
6172         bit to carry SSM Messages. This applies only to E1 BITS interfaces."
6173    DEFVAL { 8 }
6174    ::= { tSyncIfTimingAdmEntry 23 }
6175
6176tSyncIfTimingAdmQLSelection      OBJECT-TYPE
6177    SYNTAX      TmnxEnabledDisabled
6178    MAX-ACCESS  read-create
6179    STATUS      current
6180    DESCRIPTION
6181        "The value of tSyncIfTimingAdmQLSelection specifies whether or not the
6182         timing reference selection process uses the quality level of each
6183         timing reference when making the decision on which reference should
6184         provide system timing."
6185    REFERENCE "ITU-T Recommendation G.781, June 1999, Section 5.12"
6186    DEFVAL { disabled }
6187    ::= { tSyncIfTimingAdmEntry 24 }
6188
6189tSyncIfTimingAdmRefOrder4      OBJECT-TYPE
6190    SYNTAX      TmnxSETSRefSource
6191    MAX-ACCESS  read-create
6192    STATUS      current
6193    DESCRIPTION
6194        "The value of tSyncIfTimingAdmRefOrder4 specifies the fourth most
6195         preferred timing reference for the synchronous equipment timing
6196         subsystem."
6197    DEFVAL { ptp }
6198    ::= { tSyncIfTimingAdmEntry 25 }
6199
6200tSyncIfTimingAdmPTPAdminStatus   OBJECT-TYPE
6201    SYNTAX      TmnxPortAdminStatus
6202    MAX-ACCESS  read-create
6203    STATUS      current
6204    DESCRIPTION
6205        "The value of tSyncIfTimingAdmPTPAdminStatus specifies the desired
6206         administrative status of the Precision Timing Protocol (PTP) timing
6207         reference."
6208    DEFVAL { outOfService }
6209    ::= { tSyncIfTimingAdmEntry 26 }
6210
6211tSyncIfTimingAdmPTPCfgQltyLevel  OBJECT-TYPE
6212    SYNTAX      TmnxSSMQualityLevel
6213    MAX-ACCESS  read-create
6214    STATUS      current
6215    DESCRIPTION
6216        "The value of tSyncIfTimingAdmPTPCfgQltyLevel specifies the configured
6217         Quality Level of the Precision Timing Protocol (PTP). A value of
6218         'unknown (0)' specifies PTP is not forced to a specific quality level."
6219    DEFVAL { unknown }
6220    ::= { tSyncIfTimingAdmEntry 27 }
6221
6222tSyncIfTimingAdmBITSOutSource    OBJECT-TYPE
6223    SYNTAX      TmnxBITSOutSource
6224    MAX-ACCESS  read-create
6225    STATUS      current
6226    DESCRIPTION
6227        "The value of tSyncIfTimingAdmBITSOutSource specifies the source of the
6228         BITS (Building Integrated Timing Supply) output."
6229    DEFVAL { internalClock }
6230    ::= { tSyncIfTimingAdmEntry 28 }
6231
6232tSyncIfTimingAdmRefOrder5      OBJECT-TYPE
6233    SYNTAX      TmnxSETSRefSource
6234    MAX-ACCESS  read-create
6235    STATUS      current
6236    DESCRIPTION
6237        "The value of tSyncIfTimingAdmRefOrder5 specifies the fifth most
6238         preferred timing reference for the synchronous equipment timing
6239         subsystem."
6240    DEFVAL { bits2 }
6241    ::= { tSyncIfTimingAdmEntry 50 }
6242
6243tSyncIfTimingAdmBITS2InAdminStatus  OBJECT-TYPE
6244    SYNTAX      TmnxPortAdminStatus
6245    MAX-ACCESS  read-create
6246    STATUS      current
6247    DESCRIPTION
6248        "The value of tSyncIfTimingAdmBITS2InAdminStatus specifies administrative
6249         status of the BITS2 (Building Integrated Timing Supply) output timing
6250         reference."
6251    DEFVAL { outOfService }
6252    ::= { tSyncIfTimingAdmEntry 51 }
6253
6254tSyncIfTimingAdmBITS2OutAdminStatus  OBJECT-TYPE
6255    SYNTAX      TmnxPortAdminStatus
6256    MAX-ACCESS  read-create
6257    STATUS      current
6258    DESCRIPTION
6259        "The value of tSyncIfTimingAdmBITS2OutAdminStatus specifies administrative
6260         status of the BITS2 (Building Integrated Timing Supply) output timing
6261         reference."
6262    DEFVAL { outOfService }
6263    ::= { tSyncIfTimingAdmEntry 52 }
6264
6265--
6266-- Administrative value control objects
6267--
6268
6269tmnxChassisAdminOwner  OBJECT-TYPE
6270    SYNTAX       SnmpAdminString
6271    MAX-ACCESS   read-write
6272    STATUS       current
6273    DESCRIPTION
6274        "Who has last initialized the chassis administrative table,
6275        who is making all the changes, and who is expected to
6276        either commit or re-initialize (ABORT-TRANSACTION).
6277
6278        tmnxChassisAdminOwner is advisory only. Before beginning a transaction,
6279        read tmnxChassisAdminOwner.  if it is empty then proceed with the
6280        configuration.
6281
6282        Set tmnxChassisAdminOwner after setting tmnxChassisAdminControlApply so
6283        that other users will be advised to not make changes to the Admin
6284        tables.
6285
6286        Agent sets tmnxChassisAdminOwner to empty string after
6287        tmnxChassisAdminControlApply is set - either by user initializing or
6288        committing, or by agent timing out the uncommitted transactions
6289        (tmnxChassisAdminLastSetTimer).
6290        "
6291    ::= { tmnxChassisAdminCtrlObjs 1 }
6292
6293tmnxChassisAdminControlApply  OBJECT-TYPE
6294    SYNTAX       INTEGER
6295                 {
6296                     none(1),
6297                     initialize(2),
6298                     commit(3)
6299                 }
6300    MAX-ACCESS   read-write
6301    STATUS       current
6302    DESCRIPTION
6303        "This object controls the use of tmnxChassisAdminTable.
6304
6305        when set to initialize(2), the objects in tmnxChassisAdminTable
6306        are set to the current Operational values, from the tmnxChassisTable.
6307        Any uncommitted changes are lost, so setting this value corresponds
6308        to both BEGIN-TRANSACTION and ABORT-TRANSACTION.
6309
6310        when set to commit(3) (END-TRANSACTION), all of the objects from
6311        tmnxChassisAdminTable are copied to the corresponding tmnxChassisTable
6312        table objects.
6313        "
6314    ::= { tmnxChassisAdminCtrlObjs 2 }
6315
6316tmnxChassisAdminLastSetTimer  OBJECT-TYPE
6317    SYNTAX       TimeInterval
6318    UNITS        "centiseconds"
6319    MAX-ACCESS   read-only
6320    STATUS       current
6321    DESCRIPTION
6322        "The time remaining until the agent re-initializes the
6323        administrative tables.
6324
6325        If tmnxChassisAdminControlApply is not set to commit(3) within
6326        tmnxChassisAdminLastSetTimeout centiseconds, the agent will set it
6327        to initialize(2) and all uncommitted changes will be lost.
6328
6329        This way, uncommitted changes from failed (uncompleted) change sets
6330        will eventually be removed, and another transaction can safely begin.
6331
6332        this object is reset to tmnxChassisAdminLastSetTimeout after SNMP SET
6333        operation to any of the tmnxChassisAdminValue tables.
6334        "
6335    ::= { tmnxChassisAdminCtrlObjs 3 }
6336
6337tmnxChassisAdminLastSetTimeout  OBJECT-TYPE
6338    SYNTAX       TimeInterval
6339    UNITS        "centiseconds"
6340    MAX-ACCESS   read-write
6341    STATUS       current
6342    DESCRIPTION
6343        "Timeout for tmnxChassisAdminLastSetTimer.
6344         The value zero is not allowed.
6345        "
6346    DEFVAL { 180000 }
6347    ::= { tmnxChassisAdminCtrlObjs 4 }
6348
6349
6350--
6351--      Cross Connect Aggregation Group Table
6352--
6353
6354tmnxCcagTable OBJECT-TYPE
6355    SYNTAX      SEQUENCE OF TmnxCcagEntry
6356    MAX-ACCESS  not-accessible
6357    STATUS      current
6358    DESCRIPTION
6359        "The tmnxCcagTable has an entry for each Cross Connect Aggregation
6360         Group,CCAG, configured on this system."
6361    ::= { tmnxCardObjs 12 }
6362
6363tmnxCcagEntry    OBJECT-TYPE
6364    SYNTAX      TmnxCcagEntry
6365    MAX-ACCESS  not-accessible
6366    STATUS      current
6367    DESCRIPTION
6368        "Each row entry represents a particular CCAG.
6369         Entries are created/deleted by the user.
6370         There is no StorageType object, entries have a presumed
6371         StorageType of nonVolatile."
6372    INDEX { tmnxCcagId }
6373    ::= { tmnxCcagTable 1}
6374
6375TmnxCcagEntry ::= SEQUENCE
6376{
6377    tmnxCcagId                  TmnxCcagId,
6378    tmnxCcagRowStatus           RowStatus,
6379    tmnxCcagLastChanged         TimeStamp,
6380    tmnxCcagDescription         DisplayString,
6381    tmnxCcagAdminStatus         TmnxAdminState,
6382    tmnxCcagOperStatus          TmnxOperState,
6383    tmnxCcagCcaRate             TmnxCcagRate,
6384    tmnxCcagAccessAdaptQos      INTEGER
6385}
6386
6387tmnxCcagId         OBJECT-TYPE
6388    SYNTAX      TmnxCcagId
6389    MAX-ACCESS  not-accessible
6390    STATUS      current
6391    DESCRIPTION
6392        "The value of tmnxCcagId is used to index into the
6393         tmnxCcagTable. It uniquely identifies a CCAG entry
6394         as configured on this system."
6395    ::= { tmnxCcagEntry 1 }
6396
6397tmnxCcagRowStatus        OBJECT-TYPE
6398    SYNTAX      RowStatus
6399    MAX-ACCESS  read-create
6400    STATUS      current
6401    DESCRIPTION
6402        "The value of tmnxCcagRowStatus specifies the row status. It
6403         allows entries to be created and deleted in the tmnxCcagTable.
6404         tmnxCcagRowStatus does not support createAndWait. The status
6405         can only be active or notInService."
6406    ::= { tmnxCcagEntry 2 }
6407
6408tmnxCcagLastChanged     OBJECT-TYPE
6409    SYNTAX      TimeStamp
6410    MAX-ACCESS  read-only
6411    STATUS      current
6412    DESCRIPTION
6413        "The value of tmnxCcagLastChanged indicates the time this row
6414         was last changed."
6415    ::= { tmnxCcagEntry 3 }
6416
6417tmnxCcagDescription        OBJECT-TYPE
6418    SYNTAX      DisplayString
6419    MAX-ACCESS  read-create
6420    STATUS      current
6421    DESCRIPTION
6422        "The value of tmnxCcagDescription specifies a user provided
6423         description string of this CCAG entry."
6424    DEFVAL      { ''H }
6425    ::= { tmnxCcagEntry 4 }
6426
6427tmnxCcagAdminStatus     OBJECT-TYPE
6428    SYNTAX      TmnxAdminState
6429    MAX-ACCESS  read-create
6430    STATUS      current
6431    DESCRIPTION
6432        "The value of tmnxCcagAdminStatus specifies the desired state of this
6433         CCAG."
6434    DEFVAL      { inService }
6435    ::= { tmnxCcagEntry 5 }
6436
6437tmnxCcagOperStatus      OBJECT-TYPE
6438    SYNTAX      TmnxOperState
6439    MAX-ACCESS  read-only
6440    STATUS      current
6441    DESCRIPTION
6442        "The value of tmnxCcagOperStatus indicates the operational state of this
6443         CCAG."
6444    ::= { tmnxCcagEntry 6 }
6445
6446tmnxCcagCcaRate        OBJECT-TYPE
6447    SYNTAX      TmnxCcagRate
6448    UNITS       "kilobits per second"
6449    MAX-ACCESS  read-create
6450    STATUS      current
6451    DESCRIPTION
6452        "The value of tmnxCcagCcaRate specifies the maximum forwarding rate
6453         for each CCA member within the CCAG."
6454    DEFVAL { -1 }
6455    ::= { tmnxCcagEntry 7 }
6456
6457tmnxCcagAccessAdaptQos  OBJECT-TYPE
6458    SYNTAX      INTEGER
6459                {
6460                   link (1),
6461                   distribute (2)
6462                }
6463    MAX-ACCESS  read-create
6464    STATUS      current
6465    DESCRIPTION
6466        "The value of tmnxCcagAccessAdaptQos specifies how the CCAG SAP queue
6467         and virtual scheduler buffering and rate parameters are adapted over
6468         multiple active CCAs.
6469         link           (1) - The CCAG will create the SAP queues and virtual
6470                              schedulers on each CCA with the actual parameters
6471                              specified in the tmnxCcagPathCcTable.
6472         distribute     (2) - Each CCA will receive a portion of the parameters
6473                              specified in the tmnxCcagPathCcTable."
6474    DEFVAL { distribute }
6475    ::= { tmnxCcagEntry 8 }
6476
6477--
6478--      Cross Connect Aggregation Group Path Table
6479--
6480
6481tmnxCcagPathTable OBJECT-TYPE
6482    SYNTAX      SEQUENCE OF TmnxCcagPathEntry
6483    MAX-ACCESS  not-accessible
6484    STATUS      current
6485    DESCRIPTION
6486        "The tmnxCcagPathTable has an entry for each Cross Connect
6487         Aggregation Group, CCAG, path configured on this system."
6488    ::= { tmnxCardObjs 13 }
6489
6490tmnxCcagPathEntry    OBJECT-TYPE
6491    SYNTAX      TmnxCcagPathEntry
6492    MAX-ACCESS  not-accessible
6493    STATUS      current
6494    DESCRIPTION
6495        "Each row entry represents a particular CCAG Path.
6496         Entries are created/deleted by the user.
6497         There is no StorageType object, entries have a presumed
6498         StorageType of nonVolatile."
6499    INDEX { tmnxCcagId, tmnxCcagPathId }
6500    ::= { tmnxCcagPathTable 1}
6501
6502TmnxCcagPathEntry ::= SEQUENCE
6503{
6504    tmnxCcagPathId              INTEGER,
6505    tmnxCcagPathLastChanged     TimeStamp,
6506    tmnxCcagPathRate            TmnxCcagRate,
6507    tmnxCcagPathRateOption      TmnxCcagRateOption,
6508    tmnxCcagPathWeight          Unsigned32
6509}
6510
6511tmnxCcagPathId        OBJECT-TYPE
6512    SYNTAX      INTEGER {
6513                    alpha (1),
6514                    beta  (2)
6515                }
6516    MAX-ACCESS  not-accessible
6517    STATUS      current
6518    DESCRIPTION
6519        "The value of tmnxCcagPathId is used as the secondary index into
6520         the tmnxCcagPathTable. Along with tmnxCcagId, it uniquely identifies
6521         a specific path, alpha or beta, on a CCAG."
6522    ::= { tmnxCcagPathEntry 1 }
6523
6524tmnxCcagPathLastChanged       OBJECT-TYPE
6525    SYNTAX      TimeStamp
6526    MAX-ACCESS  read-only
6527    STATUS      current
6528    DESCRIPTION
6529        "The value of tmnxCcagPathLastChanged indicates the time this row
6530         was last changed."
6531    ::= { tmnxCcagPathEntry 2 }
6532
6533tmnxCcagPathRate        OBJECT-TYPE
6534    SYNTAX      TmnxCcagRate
6535    UNITS       "kilobits per second"
6536    MAX-ACCESS  read-create
6537    STATUS      current
6538    DESCRIPTION
6539        "The value of tmnxCcagPathRate specifies the bandwidth rate
6540         limitation for this path on each member cross connect
6541         adaptor, CCA, in the CCAG."
6542    DEFVAL { -1 }
6543    ::= { tmnxCcagPathEntry 3 }
6544
6545tmnxCcagPathRateOption        OBJECT-TYPE
6546    SYNTAX      TmnxCcagRateOption
6547    MAX-ACCESS  read-create
6548    STATUS      current
6549    DESCRIPTION
6550        "The value of tmnxCcagPathRateOption specifies whether the
6551         rate in tmnxCcagPathRate is defined as an aggregate path
6552         rate for all CCAs in the CCAG or as a per CCA path
6553         rate."
6554    DEFVAL { aggregate }
6555    ::= { tmnxCcagPathEntry 4 }
6556
6557tmnxCcagPathWeight        OBJECT-TYPE
6558    SYNTAX      Unsigned32 (1..100)
6559    MAX-ACCESS  read-create
6560    STATUS      current
6561    DESCRIPTION
6562        "The value of tmnxCcagPathWeight specifies the scheduling
6563         percentage for this path. It is applied to all CCAs in
6564         the CCAG membership list for this path."
6565    DEFVAL { 50 }
6566    ::= { tmnxCcagPathEntry 5 }
6567
6568--
6569--      CCAG Path Cross-Connect Table
6570--
6571
6572tmnxCcagPathCcTable OBJECT-TYPE
6573    SYNTAX      SEQUENCE OF TmnxCcagPathCcEntry
6574    MAX-ACCESS  not-accessible
6575    STATUS      current
6576    DESCRIPTION
6577        "The tmnxCcagPathCcTable has an entry for each type of Cross
6578         Connection on a Cross Connect Aggregation Group Path
6579         configured on this system."
6580    ::= { tmnxCardObjs 14 }
6581
6582tmnxCcagPathCcEntry    OBJECT-TYPE
6583    SYNTAX      TmnxCcagPathCcEntry
6584    MAX-ACCESS  not-accessible
6585    STATUS      current
6586    DESCRIPTION
6587        "Each row entry represents a particular CCAG Path Cross Connect.
6588         Entries are created/deleted by the user.
6589         There is no StorageType object, entries have a presumed
6590         StorageType of nonVolatile."
6591    INDEX { tmnxCcagId, tmnxCcagPathId, tmnxCcagPathCcType }
6592    ::= { tmnxCcagPathCcTable 1}
6593
6594TmnxCcagPathCcEntry ::= SEQUENCE
6595{
6596    tmnxCcagPathCcType                  INTEGER,
6597    tmnxCcagPathCcLastChanged           TimeStamp,
6598    tmnxCcagPathCcEgrPoolResvCbs        INTEGER,
6599    tmnxCcagPathCcEgrPoolSlpPlcy        TNamedItem,
6600    tmnxCcagPathCcIngPoolResvCbs        INTEGER,
6601    tmnxCcagPathCcIngPoolSlpPlcy        TNamedItem,
6602    tmnxCcagPathCcAcctPolicyId          Unsigned32,
6603    tmnxCcagPathCcCollectStats          TruthValue,
6604    tmnxCcagPathCcQueuePlcy             TNamedItem,
6605    tmnxCcagPathCcMac                   MacAddress,
6606    tmnxCcagPathCcMtu                   Unsigned32,
6607    tmnxCcagPathCcUserAssignedMac       TruthValue,
6608    tmnxCcagPathCcHwMac                 MacAddress
6609}
6610
6611tmnxCcagPathCcType        OBJECT-TYPE
6612    SYNTAX      INTEGER {
6613                    sapsap (1),
6614                    sapnet (2),
6615                    netsap (3)
6616                }
6617    MAX-ACCESS  not-accessible
6618    STATUS      current
6619    DESCRIPTION
6620        "The value of tmnxCcagPathCcType is used as a third index into
6621         the tmnxCcagPathCcTable. Along with tmnxCcagId and tmnxCcagPathId,
6622         it uniquely identifies a cross connection type on a specific path
6623         in a particular CCAG. The types are:
6624         sapsap (1): the cross connection is between two saps, where both
6625                     services are access.
6626         sapnet (2): the cross connection is between a sap and a network
6627                     service.
6628         netsap (3): the cross connection is between a network and a sap
6629                     service."
6630    ::= { tmnxCcagPathCcEntry 1 }
6631
6632tmnxCcagPathCcLastChanged       OBJECT-TYPE
6633    SYNTAX      TimeStamp
6634    MAX-ACCESS  read-only
6635    STATUS      current
6636    DESCRIPTION
6637        "The value of tmnxCcagPathCcLastChanged indicates the time this row
6638         was last changed."
6639    ::= { tmnxCcagPathCcEntry 2 }
6640
6641tmnxCcagPathCcEgrPoolResvCbs        OBJECT-TYPE
6642    SYNTAX      INTEGER (-1|0..100)
6643    MAX-ACCESS  read-create
6644    STATUS      current
6645    DESCRIPTION
6646        "The value of tmnxCcagPathCcEgrPoolResvCbs specifies the percentage
6647         of pool size reserved for the committed burst size, CBS. The value '-1'
6648         implies that the reserved CBS should be computed as the sum of
6649         the CBS requested by the entities using this pool if the application
6650         point is 'network'. For 'access' application points the value '-1'
6651         means a default of 30%."
6652    DEFVAL { -1 }
6653    ::= { tmnxCcagPathCcEntry 3 }
6654
6655tmnxCcagPathCcEgrPoolSlpPlcy        OBJECT-TYPE
6656    SYNTAX      TNamedItem
6657    MAX-ACCESS  read-create
6658    STATUS      current
6659    DESCRIPTION
6660        "The value of tmnxCcagPathCcEgrPoolSlpPlcy specifies the slope
6661         policy being used for the egress pool. The Slope policies define the
6662         nature of the RED Slopes for the high and the low priority traffic."
6663    DEFVAL { "default" }
6664    ::= { tmnxCcagPathCcEntry 4 }
6665
6666tmnxCcagPathCcIngPoolResvCbs        OBJECT-TYPE
6667    SYNTAX      INTEGER (-1|0..100)
6668    MAX-ACCESS  read-create
6669    STATUS      current
6670    DESCRIPTION
6671        "The value of tmnxCcagPathCcIngPoolResvCbs specifies the percentage
6672         of pool size reserved for the committed burst size, CBS. The value '-1'
6673         implies that the reserved CBS should be computed as the sum of
6674         the CBS requested by the entities using this pool if the application
6675         point is 'network'. For 'access' application points the value '-1'
6676         means a default of 30%. tmnxCcagPathCcIngPoolResvCbs does not apply
6677         to tmnxCcagPathCcType 'netsap'."
6678    DEFVAL { -1 }
6679    ::= { tmnxCcagPathCcEntry 5 }
6680
6681tmnxCcagPathCcIngPoolSlpPlcy        OBJECT-TYPE
6682    SYNTAX      TNamedItem
6683    MAX-ACCESS  read-create
6684    STATUS      current
6685    DESCRIPTION
6686        "The value of tmnxCcagPathCcIngPoolSlpPlcy specifies the slope policy
6687         being used for the ingress pool. The Slope policies define the nature
6688         of the RED Slopes for the high and the low priority traffic.
6689         tmnxCcagPathCcIngPoolSlpPlcy does not apply to tmnxCcagPathCcType
6690         'netsap'."
6691    DEFVAL { "default" }
6692    ::= { tmnxCcagPathCcEntry 6 }
6693
6694tmnxCcagPathCcAcctPolicyId        OBJECT-TYPE
6695    SYNTAX      Unsigned32 (0..99)
6696    MAX-ACCESS  read-create
6697    STATUS      current
6698    DESCRIPTION
6699        "The value of tmnxCcagPathCcAcctPolicyId specifies the accounting
6700         policy which must be defined prior to associating it with the port.
6701         A non-zero value indicates the tmnxLogApPolicyId index identifying the
6702         policy entry in the tmnxLogApTable from the TIMETRA-LOG-MIB which is
6703         associated with this port.  A zero value indicates that there is no
6704         accounting policy associated with this port. It is only meaningful
6705         when the tmnxCcagPathCcType is 'netsap'."
6706    DEFVAL { 0 }
6707    ::= { tmnxCcagPathCcEntry 7 }
6708
6709tmnxCcagPathCcCollectStats        OBJECT-TYPE
6710    SYNTAX      TruthValue
6711    MAX-ACCESS  read-create
6712    STATUS      current
6713    DESCRIPTION
6714        "The value of tmnxCcagPathCcCollectStats specifies whether the collection
6715         of accounting and statistical data for the network port is
6716         enabled/disabled, 'true'/'false'. When applying accounting policies the
6717         data by default will be collected in the appropriate records and
6718         written to the designated billing file.
6719         When the value is set to false, the statistics are still accumulated
6720         by the IOM cards, however, the CPU will not obtain the results and
6721         write them to the billing file. If the value of tmnxCcagPathCcType is
6722         not 'netsap', the value of this object is meaningless and an attempt
6723         to set it will result in an inconsistentValue error."
6724    DEFVAL { false }
6725    ::= { tmnxCcagPathCcEntry 8 }
6726
6727tmnxCcagPathCcQueuePlcy        OBJECT-TYPE
6728    SYNTAX      TNamedItem
6729    MAX-ACCESS  read-create
6730    STATUS      current
6731    DESCRIPTION
6732        "The value of tmnxCcagPathCcQueuePlcy specifies the network egress
6733         queue policy. If the value of tmnxCcagPathCcType is
6734         not 'netsap', the value of this object is meaningless and an attempt
6735         to set it will result in an inconsistentValue error."
6736    DEFVAL { "default" }
6737    ::= { tmnxCcagPathCcEntry 9 }
6738
6739tmnxCcagPathCcMac       OBJECT-TYPE
6740    SYNTAX      MacAddress
6741    MAX-ACCESS  read-create
6742    STATUS      current
6743    DESCRIPTION
6744        "The value of tmnxCcagPathCcMac specifies the MAC address of
6745         the virtual LAG that maps to tmnxCcagPathId and tmnxCcagPathCcType.
6746         The default value of this object is derived from the chassis MAC
6747         address pool."
6748    DEFVAL {'000000000000'h }
6749    ::= { tmnxCcagPathCcEntry 10 }
6750
6751tmnxCcagPathCcMtu       OBJECT-TYPE
6752    SYNTAX      Unsigned32
6753    MAX-ACCESS  read-create
6754    STATUS      current
6755    DESCRIPTION
6756        "The value of tmnxCcagPathCcMtu specifies the MTU of the path
6757         indexed by tmnxCcagId, tmnxCcagPathId, and tmnxCcagPathCcType.
6758         When the value is '0', the real MTU is calculated internally."
6759    DEFVAL { 0 }
6760    ::= { tmnxCcagPathCcEntry 11 }
6761
6762tmnxCcagPathCcUserAssignedMac OBJECT-TYPE
6763    SYNTAX      TruthValue
6764    MAX-ACCESS  read-only
6765    STATUS      current
6766    DESCRIPTION
6767        "The value of tmnxCcagPathCcUserAssignedMac indicates whether
6768         the value of tmnxCcagPathCcMac has been explicitly assigned
6769         or inherited from tmnxCcagPathCcHwMac, 'true' and 'false',
6770         respectively."
6771    DEFVAL { false }
6772    ::= { tmnxCcagPathCcEntry 12 }
6773
6774tmnxCcagPathCcHwMac     OBJECT-TYPE
6775    SYNTAX      MacAddress
6776    MAX-ACCESS  read-only
6777    STATUS      current
6778    DESCRIPTION
6779        "The value of tmnxCcagPathCcHwMac is the system assigned MAC
6780         address of the virtual LAG that maps to tmnxCcagPathId and
6781         tmnxCcagPathCcType. When tmnxCcagPathCcUserAssignedMac is
6782         'false', tmnxCcagPathCcMac inherits its value from this object."
6783    ::= { tmnxCcagPathCcEntry 13 }
6784
6785
6786--
6787--  Alcatel-Lucent 7710 SR series Mda Carrier Module (MCM) Table
6788--
6789
6790tmnxMcmTable    OBJECT-TYPE
6791    SYNTAX  SEQUENCE OF TmnxMcmEntry
6792    MAX-ACCESS  not-accessible
6793    STATUS      current
6794    DESCRIPTION
6795        "The tmnxMcmTable has an entry for each Mda Carrier module
6796         (MCM) on the 7710 system."
6797    ::= { tmnxCardObjs 15 }
6798
6799tmnxMcmEntry       OBJECT-TYPE
6800    SYNTAX      TmnxMcmEntry
6801    MAX-ACCESS  not-accessible
6802    STATUS      current
6803    DESCRIPTION
6804        "Each row entry represents a MCM in a chassis in the 7710 system.
6805         Entries in the table cannot be created and deleted via SNMP SET
6806         operations.  When a tmnxChassisEntry is created, a
6807         tmnxMcmEntry is created in the chassis.  Before a
6808         tmnxChassisEntry can be deleted, each tmnxMcmEntry
6809         for the chassis must be in the proper state for removal."
6810    INDEX   { tmnxChassisIndex, tmnxCardSlotNum, tmnxMcmSlotNum }
6811    ::= { tmnxMcmTable 1 }
6812
6813TmnxMcmEntry ::=
6814    SEQUENCE {
6815        tmnxMcmSlotNum              Unsigned32,
6816        tmnxMcmSupportedTypes       TmnxMcmType,
6817        tmnxMcmAssignedType         TmnxMcmType,
6818        tmnxMcmEquippedType         TmnxMcmType,
6819        tmnxMcmHwIndex              TmnxHwIndex
6820    }
6821
6822tmnxMcmSlotNum     OBJECT-TYPE
6823    SYNTAX      Unsigned32 (0..16)
6824    MAX-ACCESS  not-accessible
6825    STATUS      current
6826    DESCRIPTION
6827        "The unique value which identifies this MDA slot within a specific
6828         IOM card in the system.  Since the MCM occupies two MDA slots in
6829         the chassis this value can only be an odd number."
6830    ::= { tmnxMcmEntry 1 }
6831
6832tmnxMcmSupportedTypes  OBJECT-TYPE
6833    SYNTAX      TmnxMcmType
6834    MAX-ACCESS  read-only
6835    STATUS      current
6836    DESCRIPTION
6837        "A bit-mask that specifies what MCM types can be physically supported
6838         in this chassis."
6839    ::= { tmnxMcmEntry 2 }
6840
6841tmnxMcmAssignedType        OBJECT-TYPE
6842    SYNTAX      TmnxMcmType
6843    MAX-ACCESS  read-write
6844    STATUS      current
6845    DESCRIPTION
6846        "A bit-mask that identifies the administratively assigned
6847         (pre-provisioned) MCM type that should occupy this chassis.
6848         If tmnxMcmAssignedType has a value of 'unassigned',
6849         this slot has not yet been pre-provisioned.  There must not be more
6850         than one bit set at a time in tmnxMcmAssignedType."
6851    DEFVAL { 1 }
6852    ::= { tmnxMcmEntry 3 }
6853
6854tmnxMcmEquippedType        OBJECT-TYPE
6855    SYNTAX      TmnxMcmType
6856    MAX-ACCESS  read-only
6857    STATUS      current
6858    DESCRIPTION
6859        "A bit-mask that identifies the MCM type that is physically
6860         inserted into this chassis.  If the chassis has been pre-provisioned,
6861         tmnxMcmAssignedType is not equal 'unassigned', and the
6862         value of tmnxMcmEquippedType is not the same as
6863         tmnxMcmAssignedType, a mis-match alarm will be raised.
6864         If the chassis has not been pre-provisioned, and the value of
6865         tmnxMcmEquippedType is not one of the supported types as
6866         specified by tmnxMcmSupportedTypes, a mis-match alarm will
6867         be raised.  There will not be more than one bit set at a time in
6868         tmnxMcmEquippedType."
6869    ::= { tmnxMcmEntry 4 }
6870
6871tmnxMcmHwIndex      OBJECT-TYPE
6872    SYNTAX      TmnxHwIndex
6873    MAX-ACCESS  read-only
6874    STATUS      current
6875    DESCRIPTION
6876        "The value of tmnxMcmHwIndex is the index into the
6877         tmnxHwTable for the row entry that represents the hardware component
6878         information for this MCM."
6879    ::= { tmnxMcmEntry 5 }
6880
6881--
6882--  Mda Carrier Module Type (MCM) Definition Table
6883--
6884tmnxMcmTypeTable OBJECT-TYPE
6885    SYNTAX      SEQUENCE OF TmnxMcmTypeEntry
6886    MAX-ACCESS  not-accessible
6887    STATUS      current
6888    DESCRIPTION
6889        "The card type table has an entry for each Alcatel-Lucent 7710 series
6890         Mda Carrier Module (MCM) model."
6891    ::= { tmnxCardObjs 16 }
6892
6893tmnxMcmTypeEntry    OBJECT-TYPE
6894    SYNTAX      TmnxMcmTypeEntry
6895    MAX-ACCESS  not-accessible
6896    STATUS      current
6897    DESCRIPTION
6898        "Each row entry represents an Alcatel-Lucent 7710 series MCM model.
6899         Rows in this table are created by the agent at initialization and
6900         cannot be created or destroyed by SNMP Get or Set requests."
6901    INDEX   { tmnxMcmTypeIndex }
6902    ::= { tmnxMcmTypeTable 1 }
6903
6904TmnxMcmTypeEntry ::=
6905    SEQUENCE {
6906        tmnxMcmTypeIndex        TmnxMcmType,
6907        tmnxMcmTypeName         TNamedItemOrEmpty,
6908        tmnxMcmTypeDescription  TItemDescription,
6909        tmnxMcmTypeStatus       TruthValue
6910    }
6911
6912tmnxMcmTypeIndex    OBJECT-TYPE
6913    SYNTAX      TmnxMcmType
6914    MAX-ACCESS  not-accessible
6915    STATUS      current
6916    DESCRIPTION
6917        "The unique index value which identifies this type of Alcatel-Lucent
6918         7710 series MCM model."
6919    ::= { tmnxMcmTypeEntry 1 }
6920
6921tmnxMcmTypeName     OBJECT-TYPE
6922    SYNTAX      TNamedItemOrEmpty
6923    MAX-ACCESS  read-only
6924    STATUS      current
6925    DESCRIPTION
6926        "The administrative name that identifies this type of Alcatel-Lucent
6927         7710 series MCM model.  This name string may be used in CLI
6928         commands to specify a particular card model type."
6929    ::= { tmnxMcmTypeEntry 2 }
6930
6931tmnxMcmTypeDescription  OBJECT-TYPE
6932    SYNTAX      TItemDescription
6933    MAX-ACCESS  read-only
6934    STATUS      current
6935    DESCRIPTION
6936        "A detailed description of this Alcatel-Lucent 7710 series MCM model."
6937    ::= { tmnxMcmTypeEntry 3 }
6938
6939tmnxMcmTypeStatus       OBJECT-TYPE
6940    SYNTAX      TruthValue
6941    MAX-ACCESS  read-only
6942    STATUS      current
6943    DESCRIPTION
6944        "When tmnxMcmTypeStatus has a value of 'true' it
6945        indicates that this MCM is supported in this revision of the
6946        management software.  When it has a value of 'false' there is no
6947        support."
6948    ::= { tmnxMcmTypeEntry 4 }
6949
6950
6951--
6952-- IPsec Integrated Service Adaptor Group table
6953--
6954tmnxIPsecIsaGrpTableLastChanged OBJECT-TYPE
6955    SYNTAX      TimeStamp
6956    MAX-ACCESS  read-only
6957    STATUS      current
6958    DESCRIPTION
6959        "The value of tmnxIPsecIsaGrpTableLastChanged indicates the
6960         sysUpTime at the time of the last modification to
6961         tmnxIPsecIsaGrpTable by adding, deleting an entry or change
6962         to a writable object in the table.
6963
6964         If no changes were made to the table since the last
6965         re-initialization of the local network management subsystem,
6966         then this object contains a zero value."
6967    ::= { tmnxCardObjs 17 }
6968
6969tmnxIPsecIsaGrpTable OBJECT-TYPE
6970    SYNTAX      SEQUENCE OF TmnxIPsecIsaGrpEntry
6971    MAX-ACCESS  not-accessible
6972    STATUS      current
6973    DESCRIPTION
6974        "Table to store entries for Groups of IPSec Integrated Service Adaptors.
6975         The table tmnxIPsecIsaGrpTable used to create and remove IPsec ISA
6976         groups. An IPsec ISA group is used to represent multiple hardware
6977         adaptors as a single entity. This allows for warm redundancy to be
6978         run between two IPsec ISAs."
6979    ::= { tmnxCardObjs 18 }
6980
6981tmnxIPsecIsaGrpEntry OBJECT-TYPE
6982    SYNTAX      TmnxIPsecIsaGrpEntry
6983    MAX-ACCESS  not-accessible
6984    STATUS      current
6985    DESCRIPTION
6986        "Information about a single IPsec group entry."
6987    INDEX { tmnxIPsecIsaGrpId }
6988    ::= { tmnxIPsecIsaGrpTable 1 }
6989
6990TmnxIPsecIsaGrpEntry ::= SEQUENCE {
6991    tmnxIPsecIsaGrpId                     TmnxTunnelGroupId,
6992    tmnxIPsecIsaGrpRowStatus              RowStatus,
6993    tmnxIPsecIsaGrpLastChanged            TimeStamp,
6994    tmnxIPsecIsaGrpDescription            TItemDescription,
6995    tmnxIPsecIsaGrpAdminState             TmnxAdminState,
6996    tmnxIPsecIsaGrpOperState              TmnxOperState,
6997    tmnxIPsecIsaGrpIsaChassis             TmnxChassisIndex,
6998    tmnxIPsecIsaGrpPrimaryIsa             TmnxHwIndexOrZero,
6999    tmnxIPsecIsaGrpBackupIsa              TmnxHwIndexOrZero,
7000    tmnxIPsecIsaGrpActiveIsa              TmnxHwIndexOrZero,
7001    tmnxIPsecIsaGrpTunnels                Unsigned32,
7002    tmnxIPsecIsaGrpMaxTunnels             Unsigned32,
7003    tmnxIPsecIsaGrpTunnelReassembly       Integer32,
7004    tmnxIPsecIsaGrpOperFlags              TmnxIpSecIsaOperFlags,
7005    tmnxIPsecIsaGrpMultiActive            TruthValue,
7006    tmnxIPsecIsaGrpActiveMda              Unsigned32,
7007    tmnxIPsecIsaGrpIpTunnels              Unsigned32,
7008    tmnxIPsecIsaGrpIpMaxTunnels           Unsigned32
7009}
7010
7011tmnxIPsecIsaGrpId OBJECT-TYPE
7012    SYNTAX      TmnxTunnelGroupId
7013    MAX-ACCESS  not-accessible
7014    STATUS      current
7015    DESCRIPTION
7016        "The value of tmnxIPsecIsaGrpId specifies the id of a
7017         TmnxIPsecIsaGrpEntry and is the primary index for the table."
7018    ::= { tmnxIPsecIsaGrpEntry 1 }
7019
7020tmnxIPsecIsaGrpRowStatus OBJECT-TYPE
7021    SYNTAX      RowStatus
7022    MAX-ACCESS  read-create
7023    STATUS      current
7024    DESCRIPTION
7025        "The tmnxIPsecIsaGrpRowStatus object is used to create and delete
7026         rows in the tmnxIPsecIsaGrpTable."
7027    ::= { tmnxIPsecIsaGrpEntry 2 }
7028
7029tmnxIPsecIsaGrpLastChanged  OBJECT-TYPE
7030    SYNTAX      TimeStamp
7031    MAX-ACCESS  read-only
7032    STATUS      current
7033    DESCRIPTION
7034        "The value of tmnxIPsecIsaGrpLastChanged indicates the sysUpTime
7035         at the time of the last modification of this entry.
7036
7037         If no changes were made to the entry since the last
7038         re-initialization of the local network management subsystem,
7039         then this object contains a zero value."
7040    ::= { tmnxIPsecIsaGrpEntry 3 }
7041
7042tmnxIPsecIsaGrpDescription  OBJECT-TYPE
7043    SYNTAX      TItemDescription
7044    MAX-ACCESS  read-create
7045    STATUS      current
7046    DESCRIPTION
7047        "The value of tmnxIPsecIsaGrpDescription specifies the user-provided
7048         description for each tmnxIPsecIsaGrpEntry in the table
7049         tmnxIPsecIsaGrpTable."
7050    DEFVAL { "" }
7051    ::= { tmnxIPsecIsaGrpEntry 4 }
7052
7053tmnxIPsecIsaGrpAdminState  OBJECT-TYPE
7054    SYNTAX      TmnxAdminState
7055    MAX-ACCESS  read-create
7056    STATUS      current
7057    DESCRIPTION
7058        "The value of tmnxIPsecIsaGrpAdminState specifies the administrative
7059         state of the tmnxIPsecIsaGrpEntry."
7060    DEFVAL { outOfService }
7061    ::= { tmnxIPsecIsaGrpEntry 5 }
7062
7063tmnxIPsecIsaGrpOperState  OBJECT-TYPE
7064    SYNTAX      TmnxOperState
7065    MAX-ACCESS  read-only
7066    STATUS      current
7067    DESCRIPTION
7068        "The value of tmnxIPsecIsaGrpOperState indicates the operational
7069         status of tmnxIPsecIsaGrpEntry."
7070    ::= { tmnxIPsecIsaGrpEntry 6 }
7071
7072tmnxIPsecIsaGrpIsaChassis  OBJECT-TYPE
7073    SYNTAX      TmnxChassisIndex
7074    MAX-ACCESS  read-create
7075    STATUS      current
7076    DESCRIPTION
7077        "The value of tmnxIPsecIsaGrpIsaChassis indicates the chassis on which
7078         the tmnxIPsecIsaGrpPrimaryIsa and tmnxIPsecIsaGrpBackupIsa are
7079         present."
7080    DEFVAL { 1 }
7081    ::= { tmnxIPsecIsaGrpEntry 7 }
7082
7083tmnxIPsecIsaGrpPrimaryIsa  OBJECT-TYPE
7084    SYNTAX      TmnxHwIndexOrZero
7085    MAX-ACCESS  read-create
7086    STATUS      current
7087    DESCRIPTION
7088        "The value of tmnxIPsecIsaGrpPrimaryIsa specifies the primary IPsec
7089         ISA to be used for this module group."
7090    DEFVAL { 0 }
7091    ::= { tmnxIPsecIsaGrpEntry 8 }
7092
7093tmnxIPsecIsaGrpBackupIsa  OBJECT-TYPE
7094    SYNTAX      TmnxHwIndexOrZero
7095    MAX-ACCESS  read-create
7096    STATUS      current
7097    DESCRIPTION
7098        "The value of tmnxIPsecIsaGrpBackupIsa specifies the backup IPsec
7099         ISA to be used for this module group."
7100    DEFVAL { 0 }
7101    ::= { tmnxIPsecIsaGrpEntry 9 }
7102
7103tmnxIPsecIsaGrpActiveIsa  OBJECT-TYPE
7104    SYNTAX      TmnxHwIndexOrZero
7105    MAX-ACCESS  read-only
7106    STATUS      current
7107    DESCRIPTION
7108        "The value of tmnxIPsecIsaGrpActiveIsa indicates the active ISA
7109         that is being used for this module group."
7110    ::= { tmnxIPsecIsaGrpEntry 10 }
7111
7112tmnxIPsecIsaGrpTunnels  OBJECT-TYPE
7113    SYNTAX      Unsigned32
7114    MAX-ACCESS  read-only
7115    STATUS      current
7116    DESCRIPTION
7117        "The value of tmnxIPsecIsaGrpTunnels indicates the number of IPSec
7118         tunnels being used for this module group."
7119    ::= { tmnxIPsecIsaGrpEntry 11 }
7120
7121tmnxIPsecIsaGrpMaxTunnels  OBJECT-TYPE
7122    SYNTAX      Unsigned32
7123    MAX-ACCESS  read-only
7124    STATUS      current
7125    DESCRIPTION
7126        "The value of tmnxIPsecIsaGrpMaxTunnels indicates the maximum number of
7127         IPSec tunnels available for this module group."
7128    ::= { tmnxIPsecIsaGrpEntry 12 }
7129
7130tmnxIPsecIsaGrpTunnelReassembly  OBJECT-TYPE
7131    SYNTAX      Integer32 (0..5000)
7132    UNITS       "milli-seconds"
7133    MAX-ACCESS  read-create
7134    STATUS      current
7135    DESCRIPTION
7136        "The value of tmnxIPsecIsaGrpTunnelReassembly specifies the maximum
7137         number of seconds to wait to receive all fragments of a particular
7138         IPSec or GRE packet for reassembly.
7139
7140         The tmnxGreTunnelReassembly value set to zero indicates that
7141         reassembly is disabled.
7142
7143         An 'inconsistentValue' error is retuned if the value is not a multiple
7144         of 100 milli-seconds."
7145    DEFVAL { 0 }
7146    ::= { tmnxIPsecIsaGrpEntry 13 }
7147
7148tmnxIPsecIsaGrpOperFlags      OBJECT-TYPE
7149    SYNTAX      TmnxIpSecIsaOperFlags
7150    MAX-ACCESS  read-only
7151    STATUS      current
7152    DESCRIPTION
7153        "The value of tmnxIPsecIsaGrpOperFlags indicates the operational flags
7154         to determine the status of tmnxIPsecIsaGrpEntry."
7155    ::= { tmnxIPsecIsaGrpEntry 14 }
7156
7157tmnxIPsecIsaGrpMultiActive      OBJECT-TYPE
7158    SYNTAX      TruthValue
7159    MAX-ACCESS  read-create
7160    STATUS      current
7161    DESCRIPTION
7162        "The value of tmnxIPsecIsaGrpMultiActive specifies whether this tunnel
7163         group will load-balance IPsec traffic on multiple MDAs."
7164    DEFVAL { false }
7165    ::= { tmnxIPsecIsaGrpEntry 15 }
7166
7167tmnxIPsecIsaGrpActiveMda      OBJECT-TYPE
7168    SYNTAX      Unsigned32 (1..16)
7169    MAX-ACCESS  read-create
7170    STATUS      current
7171    DESCRIPTION
7172        "The value of tmnxIPsecIsaGrpActiveMda specifies the number of active
7173         MDA to be used by this tunnel-group to load-balance IPsec traffic."
7174    DEFVAL { 1 }
7175    ::= { tmnxIPsecIsaGrpEntry 16 }
7176
7177tmnxIPsecIsaGrpIpTunnels  OBJECT-TYPE
7178    SYNTAX      Unsigned32
7179    MAX-ACCESS  read-only
7180    STATUS      current
7181    DESCRIPTION
7182        "The value of tmnxIPsecIsaGrpIpTunnels indicates the number of IP
7183         tunnels being used for this module group."
7184    ::= { tmnxIPsecIsaGrpEntry 17 }
7185
7186tmnxIPsecIsaGrpIpMaxTunnels  OBJECT-TYPE
7187    SYNTAX      Unsigned32
7188    MAX-ACCESS  read-only
7189    STATUS      current
7190    DESCRIPTION
7191        "The value of tmnxIPsecIsaGrpIpMaxTunnels indicates the maximum number
7192         of IP tunnels available for this module group."
7193    ::= { tmnxIPsecIsaGrpEntry 18 }
7194
7195--
7196--      HSMDA scheduler policy overrides
7197--
7198
7199tmnxHsmdaMdaSchOvrTblLastChangd OBJECT-TYPE
7200    SYNTAX      TimeStamp
7201    MAX-ACCESS  read-only
7202    STATUS      obsolete
7203    DESCRIPTION
7204        "The value of tmnxHsmdaMdaSchOvrTblLastChangd indicates the sysUpTime
7205         at the time of the last modification of tmnxHsmdaMdaSchOvrTable.
7206
7207         If no changes were made to the table since the last
7208         re-initialization of the local network management subsystem,
7209         then this object contains a zero value.
7210
7211         This object is obsoleted in 10.0 Release."
7212    ::= { tmnxCardObjs 19 }
7213
7214tmnxHsmdaMdaSchOvrTable OBJECT-TYPE
7215    SYNTAX      SEQUENCE OF TmnxHsmdaMdaSchedOverEntry
7216    MAX-ACCESS  not-accessible
7217    STATUS      obsolete
7218    DESCRIPTION
7219        "The tmnxHsmdaMdaSchOvrTable has an entry for each MDA-level HSMDA
7220         scheduler override configured on this system.
7221
7222         This table is obsoleted in 10.0 Release."
7223    ::= { tmnxCardObjs 20 }
7224
7225tmnxHsmdaMdaSchOvrEntry    OBJECT-TYPE
7226    SYNTAX      TmnxHsmdaMdaSchedOverEntry
7227    MAX-ACCESS  not-accessible
7228    STATUS      obsolete
7229    DESCRIPTION
7230        "Each row represents a particular MDA-level HSMDA scheduler override.
7231         Entries are created and deleted by the user."
7232    INDEX { tmnxChassisIndex, tmnxCardSlotNum, tmnxMDASlotNum }
7233    ::= { tmnxHsmdaMdaSchOvrTable 1}
7234
7235TmnxHsmdaMdaSchedOverEntry ::= SEQUENCE
7236    {
7237        tmnxHsmdaMdaSchOvrRowStatus          RowStatus,
7238        tmnxHsmdaMdaSchOvrLastChanged        TimeStamp,
7239        tmnxHsmdaMdaSchOvrMaxRate            THsmdaPIRMRateOverride,
7240        tmnxHsmdaMdaSchOvrGrp1Rate           THsmdaPIRMRateOverride,
7241        tmnxHsmdaMdaSchOvrGrp2Rate           THsmdaPIRMRateOverride,
7242        tmnxHsmdaMdaSchOvrClass1Rate         THsmdaPIRMRateOverride,
7243        tmnxHsmdaMdaSchOvrClass1WtInGrp     THsmdaWeightOverride,
7244        tmnxHsmdaMdaSchOvrClass2Rate         THsmdaPIRMRateOverride,
7245        tmnxHsmdaMdaSchOvrClass2WtInGrp     THsmdaWeightOverride,
7246        tmnxHsmdaMdaSchOvrClass3Rate         THsmdaPIRMRateOverride,
7247        tmnxHsmdaMdaSchOvrClass3WtInGrp     THsmdaWeightOverride,
7248        tmnxHsmdaMdaSchOvrClass4Rate         THsmdaPIRMRateOverride,
7249        tmnxHsmdaMdaSchOvrClass4WtInGrp     THsmdaWeightOverride,
7250        tmnxHsmdaMdaSchOvrClass5Rate         THsmdaPIRMRateOverride,
7251        tmnxHsmdaMdaSchOvrClass5WtInGrp     THsmdaWeightOverride,
7252        tmnxHsmdaMdaSchOvrClass6Rate         THsmdaPIRMRateOverride,
7253        tmnxHsmdaMdaSchOvrClass6WtInGrp     THsmdaWeightOverride,
7254        tmnxHsmdaMdaSchOvrClass7Rate         THsmdaPIRMRateOverride,
7255        tmnxHsmdaMdaSchOvrClass7WtInGrp     THsmdaWeightOverride,
7256        tmnxHsmdaMdaSchOvrClass8Rate         THsmdaPIRMRateOverride,
7257        tmnxHsmdaMdaSchOvrClass8WtInGrp     THsmdaWeightOverride
7258    }
7259
7260tmnxHsmdaMdaSchOvrRowStatus        OBJECT-TYPE
7261    SYNTAX      RowStatus
7262    MAX-ACCESS  read-create
7263    STATUS      obsolete
7264    DESCRIPTION
7265        "The value of tmnxHsmdaMdaSchOvrRowStatus is used for the
7266         creation and deletion of MDA-level HSMDA scheduler overrides.
7267
7268         When the tmnxMDAAssignedType of the tmnxMDAEntry indexed
7269         by the same indices of this table is a non-HSMDA MDA Type,
7270         creation will fail and return a 'noCreation' error."
7271    ::= { tmnxHsmdaMdaSchOvrEntry 1 }
7272
7273tmnxHsmdaMdaSchOvrLastChanged        OBJECT-TYPE
7274    SYNTAX      TimeStamp
7275    MAX-ACCESS  read-only
7276    STATUS      obsolete
7277    DESCRIPTION
7278        "The value of tmnxHsmdaMdaSchOvrLastChanged indicates the sysUpTime
7279         at the time of the last modification of this entry.
7280
7281         If no changes were made to the entry since the last
7282         re-initialization of the local network management subsystem,
7283         then this object contains a zero value."
7284    ::= { tmnxHsmdaMdaSchOvrEntry 2 }
7285
7286tmnxHsmdaMdaSchOvrMaxRate        OBJECT-TYPE
7287    SYNTAX      THsmdaPIRMRateOverride
7288    UNITS       "Mbps"
7289    MAX-ACCESS  read-create
7290    STATUS      obsolete
7291    DESCRIPTION
7292        "The value of tmnxHsmdaMdaSchOvrMaxRate specifies the explicit
7293         maximum frame based bandwidth limit, in megabits per second,
7294         for this HSMDA scheduler.
7295
7296         A value of -2 indicates no override.
7297
7298         This object overrides TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyMaxRate."
7299    DEFVAL      { -2 }
7300    ::= { tmnxHsmdaMdaSchOvrEntry 3 }
7301
7302tmnxHsmdaMdaSchOvrGrp1Rate          OBJECT-TYPE
7303    SYNTAX      THsmdaPIRMRateOverride
7304    UNITS       "Mbps"
7305    MAX-ACCESS  read-create
7306    STATUS      obsolete
7307    DESCRIPTION
7308        "The value of tmnxHsmdaMdaSchOvrGrp1Rate specifies the explicit
7309         maximum frame based bandwidth limit, in megabits per second, for
7310         group 1 for this HSMDA scheduler.
7311
7312         A value of -2 indicates no override.
7313
7314         This object overrides TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyGrp1Rate."
7315    DEFVAL { -2 }
7316    ::= { tmnxHsmdaMdaSchOvrEntry 4 }
7317
7318tmnxHsmdaMdaSchOvrGrp2Rate           OBJECT-TYPE
7319    SYNTAX      THsmdaPIRMRateOverride
7320    UNITS       "Mbps"
7321    MAX-ACCESS  read-create
7322    STATUS      obsolete
7323    DESCRIPTION
7324        "The value of tmnxHsmdaMdaSchOvrGrp2Rate specifies the explicit
7325         maximum frame based bandwidth limit, in megabits per second, for
7326         group 2 for this HSMDA scheduler.
7327
7328         A value of -2 indicates no override.
7329
7330         This object overrides TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyGrp2Rate."
7331    DEFVAL { -2 }
7332    ::= { tmnxHsmdaMdaSchOvrEntry 5 }
7333
7334tmnxHsmdaMdaSchOvrClass1Rate        OBJECT-TYPE
7335    SYNTAX      THsmdaPIRMRateOverride
7336    UNITS       "Mbps"
7337    MAX-ACCESS  read-create
7338    STATUS      obsolete
7339    DESCRIPTION
7340        "The value of tmnxHsmdaMdaSchOvrClass1Rate specifies the explicit
7341         maximum frame based bandwidth limit, in megabits per second, for
7342         this HSMDA scheduler policy level.
7343
7344         A value of -2 indicates no override.
7345
7346         This object overrides TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyLvl1Rate."
7347    DEFVAL { -2 }
7348    ::= { tmnxHsmdaMdaSchOvrEntry 6 }
7349
7350tmnxHsmdaMdaSchOvrClass1WtInGrp        OBJECT-TYPE
7351    SYNTAX      THsmdaWeightOverride
7352    MAX-ACCESS  read-create
7353    STATUS      obsolete
7354    DESCRIPTION
7355        "The value of tmnxHsmdaMdaSchOvrClass1WtInGrp specifies the weight
7356         the HSMDA scheduler policy should apply to this policy level
7357         within the group it belongs to.
7358
7359         The value of tmnxHsmdaMdaSchOvrClass1WtInGrp will only be
7360         used if this policy level has been assigned to a group
7361         by setting tHsmdaSchedulerPlcyLvl1GrpId to a non-zero value.
7362
7363         A value of -2 indicates no override.
7364
7365         This object overrides
7366         TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyLvl1WgtInGrp."
7367    DEFVAL { -2 }
7368    ::= { tmnxHsmdaMdaSchOvrEntry 7 }
7369
7370tmnxHsmdaMdaSchOvrClass2Rate        OBJECT-TYPE
7371    SYNTAX      THsmdaPIRMRateOverride
7372    UNITS       "Mbps"
7373    MAX-ACCESS  read-create
7374    STATUS      obsolete
7375    DESCRIPTION
7376        "The value of tmnxHsmdaMdaSchOvrClass2Rate specifies the explicit
7377         maximum frame based bandwidth limit, in megabits per second, for
7378         this HSMDA scheduler policy level.
7379
7380         A value of -2 indicates no override.
7381
7382         This object overrides TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyLvl2Rate."
7383    DEFVAL { -2 }
7384    ::= { tmnxHsmdaMdaSchOvrEntry 8 }
7385
7386tmnxHsmdaMdaSchOvrClass2WtInGrp        OBJECT-TYPE
7387    SYNTAX      THsmdaWeightOverride
7388    MAX-ACCESS  read-create
7389    STATUS      obsolete
7390    DESCRIPTION
7391        "The value of tmnxHsmdaMdaSchOvrClass2WtInGrp specifies the weight
7392         the HSMDA scheduler policy should apply to this policy level
7393         within the group it belongs to.
7394
7395         The value of tmnxHsmdaMdaSchOvrClass2WtInGrp will only be
7396         used if this policy level has been assigned to a group
7397         by setting tHsmdaSchedulerPlcyLvl2GrpId to a non-zero value.
7398
7399         A value of -2 indicates no override.
7400
7401         This object overrides
7402         TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyLvl2WgtInGrp."
7403    DEFVAL { -2 }
7404    ::= { tmnxHsmdaMdaSchOvrEntry 9 }
7405
7406tmnxHsmdaMdaSchOvrClass3Rate        OBJECT-TYPE
7407    SYNTAX      THsmdaPIRMRateOverride
7408    UNITS       "Mbps"
7409    MAX-ACCESS  read-create
7410    STATUS      obsolete
7411    DESCRIPTION
7412        "The value of tmnxHsmdaMdaSchOvrClass3Rate specifies the explicit
7413         maximum frame based bandwidth limit, in megabits per second, for
7414         this HSMDA scheduler policy level.
7415
7416         A value of -2 indicates no override.
7417
7418         This object overrides TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyLvl3Rate."
7419    DEFVAL { -2 }
7420    ::= { tmnxHsmdaMdaSchOvrEntry 10 }
7421
7422tmnxHsmdaMdaSchOvrClass3WtInGrp        OBJECT-TYPE
7423    SYNTAX      THsmdaWeightOverride
7424    MAX-ACCESS  read-create
7425    STATUS      obsolete
7426    DESCRIPTION
7427        "The value of tmnxHsmdaMdaSchOvrClass3WtInGrp specifies the weight
7428         the HSMDA scheduler policy should apply to this policy level
7429         within the group it belongs to.
7430
7431         The value of tmnxHsmdaMdaSchOvrClass3WtInGrp will only be
7432         used if this policy level has been assigned to a group
7433         by setting tHsmdaSchedulerPlcyLvl3GrpId to a non-zero value.
7434
7435         A value of -2 indicates no override.
7436
7437         This object overrides
7438         TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyLvl3WgtInGrp."
7439    DEFVAL { -2 }
7440    ::= { tmnxHsmdaMdaSchOvrEntry 11 }
7441
7442tmnxHsmdaMdaSchOvrClass4Rate        OBJECT-TYPE
7443    SYNTAX      THsmdaPIRMRateOverride
7444    UNITS       "Mbps"
7445    MAX-ACCESS  read-create
7446    STATUS      obsolete
7447    DESCRIPTION
7448        "The value of tmnxHsmdaMdaSchOvrClass4Rate specifies the explicit
7449         maximum frame based bandwidth limit, in megabits per second, for
7450         this HSMDA scheduler policy level.
7451
7452         A value of -2 indicates no override.
7453
7454         This object overrides TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyLvl4Rate."
7455    DEFVAL { -2 }
7456    ::= { tmnxHsmdaMdaSchOvrEntry 12 }
7457
7458tmnxHsmdaMdaSchOvrClass4WtInGrp        OBJECT-TYPE
7459    SYNTAX      THsmdaWeightOverride
7460    MAX-ACCESS  read-create
7461    STATUS      obsolete
7462    DESCRIPTION
7463        "The value of tmnxHsmdaMdaSchOvrClass4WtInGrp specifies the weight
7464         the HSMDA scheduler policy should apply to this policy level
7465         within the group it belongs to.
7466
7467         The value of tmnxHsmdaMdaSchOvrClass4WtInGrp will only be
7468         used if this policy level has been assigned to a group
7469         by setting tHsmdaSchedulerPlcyLvl4GrpId to a non-zero value.
7470
7471         A value of -2 indicates no override.
7472
7473         This object overrides
7474         TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyLvl4WgtInGrp."
7475    DEFVAL { -2 }
7476    ::= { tmnxHsmdaMdaSchOvrEntry 13 }
7477
7478tmnxHsmdaMdaSchOvrClass5Rate        OBJECT-TYPE
7479    SYNTAX      THsmdaPIRMRateOverride
7480    UNITS       "Mbps"
7481    MAX-ACCESS  read-create
7482    STATUS      obsolete
7483    DESCRIPTION
7484        "The value of tmnxHsmdaMdaSchOvrClass5Rate specifies the explicit
7485         maximum frame based bandwidth limit, in megabits per second, for
7486         this HSMDA scheduler policy level.
7487
7488         A value of -2 indicates no override.
7489
7490         This object overrides TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyLvl5Rate."
7491    DEFVAL { -2 }
7492    ::= { tmnxHsmdaMdaSchOvrEntry 14 }
7493
7494tmnxHsmdaMdaSchOvrClass5WtInGrp        OBJECT-TYPE
7495    SYNTAX      THsmdaWeightOverride
7496    MAX-ACCESS  read-create
7497    STATUS      obsolete
7498    DESCRIPTION
7499        "The value of tmnxHsmdaMdaSchOvrClass5WtInGrp specifies the weight
7500         the HSMDA scheduler policy should apply to this policy level
7501         within the group it belongs to.
7502
7503         The value of tmnxHsmdaMdaSchOvrClass5WtInGrp will only be
7504         used if this policy level has been assigned to a group
7505         by setting tHsmdaSchedulerPlcyLvl5GrpId to a non-zero value.
7506
7507         A value of -2 indicates no override.
7508
7509         This object overrides
7510         TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyLvl5WgtInGrp."
7511    DEFVAL { -2 }
7512    ::= { tmnxHsmdaMdaSchOvrEntry 15 }
7513
7514tmnxHsmdaMdaSchOvrClass6Rate        OBJECT-TYPE
7515    SYNTAX      THsmdaPIRMRateOverride
7516    UNITS       "Mbps"
7517    MAX-ACCESS  read-create
7518    STATUS      obsolete
7519    DESCRIPTION
7520        "The value of tmnxHsmdaMdaSchOvrClass6Rate specifies the explicit
7521         maximum frame based bandwidth limit, in megabits per second, for
7522         this HSMDA scheduler policy level.
7523
7524         A value of -2 indicates no override.
7525
7526         This object overrides TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyLvl6Rate."
7527    DEFVAL { -2 }
7528    ::= { tmnxHsmdaMdaSchOvrEntry 16 }
7529
7530tmnxHsmdaMdaSchOvrClass6WtInGrp        OBJECT-TYPE
7531    SYNTAX      THsmdaWeightOverride
7532    MAX-ACCESS  read-create
7533    STATUS      obsolete
7534    DESCRIPTION
7535        "The value of tmnxHsmdaMdaSchOvrClass6WtInGrp specifies the weight
7536         the HSMDA scheduler policy should apply to this policy level
7537         within the group it belongs to.
7538
7539         The value of tmnxHsmdaMdaSchOvrClass6WtInGrp will only be
7540         used if this policy level has been assigned to a group
7541         by setting tHsmdaSchedulerPlcyLvl6GrpId to a non-zero value.
7542
7543         A value of -2 indicates no override.
7544
7545         This object overrides
7546         TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyLvl6WgtInGrp."
7547    DEFVAL { -2 }
7548    ::= { tmnxHsmdaMdaSchOvrEntry 17 }
7549
7550tmnxHsmdaMdaSchOvrClass7Rate        OBJECT-TYPE
7551    SYNTAX      THsmdaPIRMRateOverride
7552    UNITS       "Mbps"
7553    MAX-ACCESS  read-create
7554    STATUS      obsolete
7555    DESCRIPTION
7556        "The value of tmnxHsmdaMdaSchOvrClass7Rate specifies the explicit
7557         maximum frame based bandwidth limit, in megabits per second, for
7558         this HSMDA scheduler policy level.
7559
7560         A value of -2 indicates no override.
7561
7562         This object overrides TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyLvl7Rate."
7563    DEFVAL { -2 }
7564    ::= { tmnxHsmdaMdaSchOvrEntry 18 }
7565
7566tmnxHsmdaMdaSchOvrClass7WtInGrp        OBJECT-TYPE
7567    SYNTAX      THsmdaWeightOverride
7568    MAX-ACCESS  read-create
7569    STATUS      obsolete
7570    DESCRIPTION
7571        "The value of tmnxHsmdaMdaSchOvrClass7WtInGrp specifies the weight
7572         the HSMDA scheduler policy should apply to this policy level
7573         within the group it belongs to.
7574
7575         The value of tmnxHsmdaMdaSchOvrClass7WtInGrp will only be
7576         used if this policy level has been assigned to a group
7577         by setting tHsmdaSchedulerPlcyLvl7GrpId to a non-zero value.
7578
7579         A value of -2 indicates no override.
7580
7581         This object overrides
7582         TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyLvl7WgtInGrp."
7583    DEFVAL { -2 }
7584    ::= { tmnxHsmdaMdaSchOvrEntry 19 }
7585
7586tmnxHsmdaMdaSchOvrClass8Rate        OBJECT-TYPE
7587    SYNTAX      THsmdaPIRMRateOverride
7588    UNITS       "Mbps"
7589    MAX-ACCESS  read-create
7590    STATUS      obsolete
7591    DESCRIPTION
7592        "The value of tmnxHsmdaMdaSchOvrClass8Rate specifies the explicit
7593         maximum frame based bandwidth limit, in megabits per second, for
7594         this HSMDA scheduler policy level.
7595
7596         A value of -2 indicates no override.
7597
7598         This object overrides TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyLvl8Rate."
7599    DEFVAL { -2 }
7600    ::= { tmnxHsmdaMdaSchOvrEntry 20 }
7601
7602tmnxHsmdaMdaSchOvrClass8WtInGrp        OBJECT-TYPE
7603    SYNTAX      THsmdaWeightOverride
7604    MAX-ACCESS  read-create
7605    STATUS      obsolete
7606    DESCRIPTION
7607        "The value of tmnxHsmdaMdaSchOvrClass8WtInGrp specifies the weight
7608         the HSMDA scheduler policy should apply to this policy level
7609         within the group it belongs to.
7610
7611         The value of tmnxHsmdaMdaSchOvrClass8WtInGrp will only be
7612         used if this policy level has been assigned to a group
7613         by setting tHsmdaSchedulerPlcyLvl8GrpId to a non-zero value.
7614
7615         A value of -2 indicates no override.
7616
7617         This object overrides
7618         TIMETRA-QOS-MIB::tHsmdaSchedulerPlcyLvl8WgtInGrp."
7619    DEFVAL { -2 }
7620    ::= { tmnxHsmdaMdaSchOvrEntry 21 }
7621
7622--
7623--      Forwarding Plane (FP) table
7624--
7625tmnxFPTable     OBJECT-TYPE
7626    SYNTAX      SEQUENCE OF TmnxFPEntry
7627    MAX-ACCESS  not-accessible
7628    STATUS      current
7629    DESCRIPTION
7630        "The tmnxFPTable has an entry for each Forwarding Plane configuration.
7631         An entry is created in this table whenever an entry for card is created
7632         in tmnxCardTable. This entry is relevant only for IOM3/IMM."
7633    ::= { tmnxCardObjs 21 }
7634
7635tmnxFPEntry     OBJECT-TYPE
7636    SYNTAX      TmnxFPEntry
7637    MAX-ACCESS  not-accessible
7638    STATUS      current
7639    DESCRIPTION
7640        "Each row entry represents a Forwarding Plane (FP) configuration."
7641    INDEX   { tmnxChassisIndex, tmnxCardSlotNum, tmnxFPNum }
7642    ::= { tmnxFPTable 1 }
7643
7644TmnxFPEntry ::=
7645    SEQUENCE {
7646        tmnxFPNum                       Unsigned32,
7647        tmnxFPMcPathMgmtBwPlcyName      TNamedItem,
7648        tmnxFPMcPathMgmtAdminState      TmnxAdminState,
7649        tmnxFPLastChanged               TimeStamp,
7650        tmnxFPHiBwMcastSource           TruthValue,
7651        tmnxFPHiBwMcastAlarm            TruthValue,
7652        tmnxFPHiBwMcastTapCount         Gauge32,
7653        tmnxFPHiBwMcastGroup            Unsigned32,
7654        tmnxFPWredBufAllocMin           Unsigned32,
7655        tmnxFPWredBufAllocMax           Unsigned32,
7656        tmnxFPWredResvCbsMin            Unsigned32,
7657        tmnxFPWredResvCbsMax            Unsigned32,
7658        tmnxFPWredSlopePolicy           TNamedItemOrEmpty,
7659        tmnxFPWredAdminState            TmnxAdminState,
7660        tmnxFPHiBwMcastDefaultPathsOnly TruthValue
7661    }
7662
7663tmnxFPNum       OBJECT-TYPE
7664    SYNTAX      Unsigned32
7665    MAX-ACCESS  not-accessible
7666    STATUS      current
7667    DESCRIPTION
7668        "The value of tmnxFPNum identifies the Forwarding Plane."
7669    ::= { tmnxFPEntry 1 }
7670
7671tmnxFPMcPathMgmtBwPlcyName     OBJECT-TYPE
7672    SYNTAX      TNamedItem
7673    MAX-ACCESS  read-write
7674    STATUS      current
7675    DESCRIPTION
7676        "The value of tmnxFPMcPathMgmtBwPlcyName specifies the multicast policy
7677         name configured for the FP. tmnxFPMcPathMgmtBwPlcyName can be set only
7678         if the policy exists in
7679         TIMETRA-MCAST-PATH-MGMT-MIB::tmnxMcPathBwPlcyTable."
7680    DEFVAL { "default" }
7681    ::= { tmnxFPEntry 2 }
7682
7683tmnxFPMcPathMgmtAdminState        OBJECT-TYPE
7684    SYNTAX      TmnxAdminState
7685    MAX-ACCESS  read-write
7686    STATUS      current
7687    DESCRIPTION
7688        "The value of tmnxFPMcPathMgmtAdminState specifies administrative state
7689         of the multicast path for the FP."
7690    DEFVAL { outOfService }
7691    ::= { tmnxFPEntry 3 }
7692
7693tmnxFPLastChanged  OBJECT-TYPE
7694    SYNTAX      TimeStamp
7695    MAX-ACCESS  read-only
7696    STATUS      current
7697    DESCRIPTION
7698        "The value of tmnxFPLastChanged indicates the timestamp of
7699         last change to this row in tmnxFPTable."
7700    ::= { tmnxFPEntry 4 }
7701
7702tmnxFPHiBwMcastSource   OBJECT-TYPE
7703    SYNTAX      TruthValue
7704    MAX-ACCESS  read-write
7705    STATUS      current
7706    DESCRIPTION
7707        "The value of tmnxFPHiBwMcastSource specifies if this FP should
7708         attempt to allocate separate fabric planes to allocate high bandwidth
7709         multicast traffic taps.
7710
7711         tmnxFPHiBwMcastGroup must be set in the same SNMP request PDU with
7712         tmnxFPHiBwMcastSource or an 'inconsistentValue' error will be
7713         returned."
7714    DEFVAL { false }
7715    ::= { tmnxFPEntry 5 }
7716
7717tmnxFPHiBwMcastAlarm     OBJECT-TYPE
7718    SYNTAX      TruthValue
7719    MAX-ACCESS  read-write
7720    STATUS      current
7721    DESCRIPTION
7722        "The value of tmnxFPHiBwMcastAlarm specifies if a
7723         tmnxChassisHiBwMcastAlarm alarm is raised if there are more than
7724         one high bandwidth multicast traffic taps sharing a plane."
7725    DEFVAL { true }
7726    ::= { tmnxFPEntry 6 }
7727
7728tmnxFPHiBwMcastTapCount     OBJECT-TYPE
7729    SYNTAX      Gauge32
7730    MAX-ACCESS  read-only
7731    STATUS      current
7732    DESCRIPTION
7733        "The value of tmnxFPHiBwMcastTapCount indicates the number of high
7734         bandwidth multicast traffic taps on this FP."
7735    ::= { tmnxFPEntry 7 }
7736
7737tmnxFPHiBwMcastGroup  OBJECT-TYPE
7738    SYNTAX      Unsigned32 (0..32)
7739    MAX-ACCESS  read-write
7740    STATUS      current
7741    DESCRIPTION
7742        "The value of tmnxFPHiBwMcastGroup specifies the group of high
7743         bandwidth multicast traffic taps to which this tap belongs.
7744
7745         A value of '0' specifies that this tap is not a member of any High
7746         Bandwidth Multicast group.
7747
7748         tmnxMDAHiBwMcastGroup must be set in the same SNMP request PDU with
7749         tmnxMDAHiBwMcastSource or an 'inconsistentValue' error will be
7750         returned."
7751    DEFVAL { 0 }
7752    ::= { tmnxFPEntry 8 }
7753
7754tmnxFPWredBufAllocMin  OBJECT-TYPE
7755    SYNTAX      Unsigned32 (0..9999)
7756    UNITS       "Hundredths of a percent"
7757    MAX-ACCESS  read-write
7758    STATUS      current
7759    DESCRIPTION
7760        "The value of tmnxFPWredBufAllocMin specifies the minimum WRED
7761         (Weighted Random Early Detection) queue aggregate buffer allocation
7762         which will be set aside for WRED queue buffer pools."
7763    DEFVAL { 2500 }
7764    ::= { tmnxFPEntry 9 }
7765
7766tmnxFPWredBufAllocMax  OBJECT-TYPE
7767    SYNTAX      Unsigned32 (1..9999)
7768    UNITS       "Hundredths of a percent"
7769    MAX-ACCESS  read-write
7770    STATUS      current
7771    DESCRIPTION
7772        "The value of tmnxFPWredBufAllocMax specifies the maximum WRED queue
7773         aggregate buffer allocation which will be set aside for WRED queue
7774         buffer pools."
7775    DEFVAL { 2500 }
7776    ::= { tmnxFPEntry 10 }
7777
7778tmnxFPWredResvCbsMin  OBJECT-TYPE
7779    SYNTAX      Unsigned32 (0..9999)
7780    UNITS       "Hundredths of a percent"
7781    MAX-ACCESS  read-write
7782    STATUS      current
7783    DESCRIPTION
7784        "The value of tmnxFPWredResvCbsMin specifies the minimum buffers within
7785         the WRED pool that will be set aside for WRED queues operating within
7786         their configured CBS (Committed Buffer Size) thresholds."
7787    DEFVAL { 2500 }
7788    ::= { tmnxFPEntry 11 }
7789
7790tmnxFPWredResvCbsMax  OBJECT-TYPE
7791    SYNTAX      Unsigned32 (1..9999)
7792    UNITS       "Hundredths of a percent"
7793    MAX-ACCESS  read-write
7794    STATUS      current
7795    DESCRIPTION
7796        "The value of tmnxFPWredResvCbsMax specifies the maximum buffers within
7797         the WRED pool that will be set aside for WRED queues operating within
7798         their configured CBS (Committed Buffer Size) thresholds."
7799    DEFVAL { 2500 }
7800    ::= { tmnxFPEntry 12 }
7801
7802tmnxFPWredSlopePolicy  OBJECT-TYPE
7803    SYNTAX      TNamedItemOrEmpty
7804    MAX-ACCESS  read-write
7805    STATUS      current
7806    DESCRIPTION
7807        "The value of tmnxFPWredSlopePolicy specifies the name of slope policy
7808        being used within WRED pool."
7809    DEFVAL { "default" }
7810    ::= { tmnxFPEntry 13 }
7811
7812tmnxFPWredAdminState   OBJECT-TYPE
7813    SYNTAX      TmnxAdminState
7814    MAX-ACCESS  read-write
7815    STATUS      current
7816    DESCRIPTION
7817        "The value of tmnxFPWredAdminState specifies administrative state
7818         of the egress WRED queue support on the card."
7819    DEFVAL { outOfService }
7820    ::= { tmnxFPEntry 14 }
7821
7822tmnxFPHiBwMcastDefaultPathsOnly  OBJECT-TYPE
7823    SYNTAX      TruthValue
7824    MAX-ACCESS  read-write
7825    STATUS      current
7826    DESCRIPTION
7827        "The value of tmnxFPHiBwMcastDefaultPathsOnly specifies whether only the
7828         default paths are to be High Bandwidth Multicast (HBM) (typically paths
7829         0 and 15) and the remaining paths are non-HBM 'true (1)', or all paths
7830         are configured HBM on the forwarding path 'false (2)'.
7831
7832         This object is only meaningful if tmnxFPHiBwMcastSource is set to the
7833         value 'true (1)'."
7834    DEFVAL      { false }
7835    ::= { tmnxFPEntry 15 }
7836
7837--
7838-- access ingress queue group table
7839--
7840
7841tmnxFPAccIngQGrpTableLastChgd OBJECT-TYPE
7842    SYNTAX       TimeStamp
7843    MAX-ACCESS   read-only
7844    STATUS       current
7845    DESCRIPTION
7846        "The value of tmnxFPAccIngQGrpTableLastChgd indicates the
7847        timestamp of last change to the tmnxFPAccIngQGrpTable."
7848    ::= { tmnxCardObjs 22 }
7849
7850tmnxFPAccIngQGrpTable OBJECT-TYPE
7851    SYNTAX       SEQUENCE OF TmnxFPAccIngQGrpEntry
7852    MAX-ACCESS   not-accessible
7853    STATUS       current
7854    DESCRIPTION
7855        "The value of tmnxFPAccIngQGrpTable defines access Ingress Queue Group
7856        Table for providing, via SNMP, the capability of defining the
7857        forwarding-plane specific queue groups from the queue-groups existing
7858        in the TIMETRA-QOS-MIB::tQosIngQGroupTable."
7859    ::= { tmnxCardObjs 23 }
7860
7861tmnxFPAccIngQGrpEntry OBJECT-TYPE
7862    SYNTAX       TmnxFPAccIngQGrpEntry
7863    MAX-ACCESS   not-accessible
7864    STATUS       current
7865    DESCRIPTION
7866        "The value of tmnxFPAccIngQGrpEntry defines an entry in the
7867        tmnxFPAccIngQGrpTable.
7868
7869        Entries are created/deleted in this table by SNMP sets to
7870        tmnxFPAccIngQGrpRowStatus."
7871    INDEX   { tmnxChassisIndex, tmnxCardSlotNum, tmnxFPNum,
7872              tmnxFPAccIngQGrpName, tmnxFPAccIngQGrpInstanceId }
7873    ::= { tmnxFPAccIngQGrpTable 1 }
7874
7875TmnxFPAccIngQGrpEntry ::= SEQUENCE
7876    {
7877        tmnxFPAccIngQGrpName             TNamedItem,
7878        tmnxFPAccIngQGrpInstanceId       Unsigned32,
7879        tmnxFPAccIngQGrpRowStatus        RowStatus,
7880        tmnxFPAccIngQGrpLastChgd         TimeStamp,
7881        tmnxFPAccIngQGrpAcctgPolId       Unsigned32,
7882        tmnxFPAccIngQGrpCollectStats     TruthValue,
7883        tmnxFPAccIngQGrpDescr            TItemDescription,
7884        tmnxFPAccIngQGrpPolicerPol       TNamedItemOrEmpty
7885    }
7886
7887tmnxFPAccIngQGrpName OBJECT-TYPE
7888    SYNTAX       TNamedItem
7889    MAX-ACCESS   not-accessible
7890    STATUS       current
7891    DESCRIPTION
7892        "The value of tmnxFPAccIngQGrpName defines the forwarding-plane Ingress
7893        Queue Group name.  It, along with tmnxFPAccIngQGrpInstanceId uniquely
7894        identifies a forwarding-plane ingress queue group in the managed
7895        system."
7896    ::= { tmnxFPAccIngQGrpEntry 1 }
7897
7898tmnxFPAccIngQGrpInstanceId OBJECT-TYPE
7899    SYNTAX       Unsigned32 (1..65535)
7900    MAX-ACCESS   not-accessible
7901    STATUS       current
7902    DESCRIPTION
7903        "The value of tmnxFPAccIngQGrpInstanceId defines the unique instance of
7904        the forwarding-plane ingress Queue Group. It, along with
7905        tmnxFPAccIngQGrpName, uniquely identifies a forwarding-plane ingress
7906        queue group in the managed system."
7907    ::= { tmnxFPAccIngQGrpEntry 2 }
7908
7909tmnxFPAccIngQGrpRowStatus OBJECT-TYPE
7910    SYNTAX       RowStatus
7911    MAX-ACCESS   read-create
7912    STATUS       current
7913    DESCRIPTION
7914        "The value of tmnxFPAccIngQGrpRowStatus allows entries to be
7915        created and deleted in the tmnxFPAccIngQGrpTable.
7916
7917        The creation of an entry in this table will succeed only if the
7918        queue-group being created exists in
7919        TIMETRA-QOS-MIB::tQosIngQGroupTable."
7920    REFERENCE
7921        "See definition of RowStatus in RFC 2579, 'Textual Conventions for
7922         SMIv2.'"
7923    ::= { tmnxFPAccIngQGrpEntry 3 }
7924
7925tmnxFPAccIngQGrpLastChgd OBJECT-TYPE
7926    SYNTAX       TimeStamp
7927    MAX-ACCESS   read-only
7928    STATUS       current
7929    DESCRIPTION
7930        "The value of tmnxFPAccIngQGrpLastChgd indicates the value of
7931        sysUpTime when the queue entry was last modified."
7932    ::= { tmnxFPAccIngQGrpEntry 4 }
7933
7934tmnxFPAccIngQGrpAcctgPolId OBJECT-TYPE
7935    SYNTAX       Unsigned32 (0..99)
7936    MAX-ACCESS   read-create
7937    STATUS       current
7938    DESCRIPTION
7939        "The value of tmnxFPAccIngQGrpAcctgPolId specifies the accounting-policy
7940        to be used with this forwarding-plane ingress queue-group.
7941
7942        A non-zero value indicates the tmnxLogApPolicyId index identifying the
7943        policy entry in the tmnxLogApTable from the TIMETRA-LOG-MIB which is
7944        associated with this queue-group.
7945
7946        The value zero indicates that the agent should use the default
7947        accounting policy, if one exists."
7948    DEFVAL { 0 }
7949    ::= { tmnxFPAccIngQGrpEntry 5 }
7950
7951tmnxFPAccIngQGrpCollectStats OBJECT-TYPE
7952    SYNTAX       TruthValue
7953    MAX-ACCESS   read-create
7954    STATUS       current
7955    DESCRIPTION
7956        "The value of tmnxFPAccIngQGrpCollectStats specifies whether
7957        statistics should be collected on this forwarding-plane ingress
7958        queue-group."
7959    DEFVAL { false }
7960    ::= { tmnxFPAccIngQGrpEntry 6 }
7961
7962tmnxFPAccIngQGrpDescr OBJECT-TYPE
7963    SYNTAX       TItemDescription
7964    MAX-ACCESS   read-create
7965    STATUS       current
7966    DESCRIPTION
7967        "The value of tmnxFPAccIngQGrpDescr specifies the description for
7968        this forwarding-plane queue-group."
7969    DEFVAL { ''H }
7970    ::= { tmnxFPAccIngQGrpEntry 7 }
7971
7972tmnxFPAccIngQGrpPolicerPol OBJECT-TYPE
7973    SYNTAX       TNamedItemOrEmpty
7974    MAX-ACCESS   read-create
7975    STATUS       current
7976    DESCRIPTION
7977        "The value of tmnxFPAccIngQGrpPolicerPol specifies the name of
7978        the policer control policy to be used with this forwarding-plane ingress
7979        queue-group."
7980    DEFVAL { ''H }
7981    ::= { tmnxFPAccIngQGrpEntry 8 }
7982
7983--
7984-- access ingress queue group table
7985--
7986
7987tmnxFPNetIngQGrpTableLastChgd OBJECT-TYPE
7988    SYNTAX       TimeStamp
7989    MAX-ACCESS   read-only
7990    STATUS       current
7991    DESCRIPTION
7992        "The value of tmnxFPNetIngQGrpTableLastChgd indicates the
7993        timestamp of last change to the tmnxFPNetIngQGrpTable."
7994    ::= { tmnxCardObjs 24 }
7995
7996tmnxFPNetIngQGrpTable OBJECT-TYPE
7997    SYNTAX       SEQUENCE OF TmnxFPNetIngQGrpEntry
7998    MAX-ACCESS   not-accessible
7999    STATUS       current
8000    DESCRIPTION
8001        "The value of tmnxFPNetIngQGrpTable defines access Ingress Queue Group
8002        Table for providing, via SNMP, the capability of defining the
8003        forwarding-plane specific queue groups from the queue-groups existing
8004        in the TIMETRA-QOS-MIB::tQosIngQGroupTable."
8005    ::= { tmnxCardObjs 25 }
8006
8007tmnxFPNetIngQGrpEntry OBJECT-TYPE
8008    SYNTAX       TmnxFPNetIngQGrpEntry
8009    MAX-ACCESS   not-accessible
8010    STATUS       current
8011    DESCRIPTION
8012        "The value of tmnxFPNetIngQGrpEntry defines an entry in the
8013        tmnxFPNetIngQGrpTable.
8014
8015        Entries are created/deleted in this table by SNMP sets to
8016        tmnxFPNetIngQGrpRowStatus."
8017    INDEX   { tmnxChassisIndex, tmnxCardSlotNum, tmnxFPNum,
8018              tmnxFPNetIngQGrpName, tmnxFPNetIngQGrpInstanceId }
8019    ::= { tmnxFPNetIngQGrpTable 1 }
8020
8021TmnxFPNetIngQGrpEntry ::= SEQUENCE
8022    {
8023        tmnxFPNetIngQGrpName             TNamedItem,
8024        tmnxFPNetIngQGrpInstanceId       Unsigned32,
8025        tmnxFPNetIngQGrpRowStatus        RowStatus,
8026        tmnxFPNetIngQGrpLastChgd         TimeStamp,
8027        tmnxFPNetIngQGrpAcctgPolId       Unsigned32,
8028        tmnxFPNetIngQGrpCollectStats     TruthValue,
8029        tmnxFPNetIngQGrpDescr            TItemDescription,
8030        tmnxFPNetIngQGrpPolicerPol       TNamedItemOrEmpty
8031    }
8032
8033tmnxFPNetIngQGrpName OBJECT-TYPE
8034    SYNTAX       TNamedItem
8035    MAX-ACCESS   not-accessible
8036    STATUS       current
8037    DESCRIPTION
8038        "The value of tmnxFPNetIngQGrpName defines the forwarding-plane Ingress
8039        Queue Group name.  It, along with tmnxFPNetIngQGrpInstanceId uniquely
8040        identifies a forwarding-plane ingress queue group in the managed
8041        system."
8042    ::= { tmnxFPNetIngQGrpEntry 1 }
8043
8044tmnxFPNetIngQGrpInstanceId OBJECT-TYPE
8045    SYNTAX       Unsigned32 (1..65535)
8046    MAX-ACCESS   not-accessible
8047    STATUS       current
8048    DESCRIPTION
8049        "The value of tmnxFPNetIngQGrpInstanceId defines the unique instance of
8050        the forwarding-plane ingress Queue Group. It, along with
8051        tmnxFPNetIngQGrpName, uniquely identifies a forwarding-plane ingress
8052        queue group in the managed system."
8053    ::= { tmnxFPNetIngQGrpEntry 2 }
8054
8055tmnxFPNetIngQGrpRowStatus OBJECT-TYPE
8056    SYNTAX       RowStatus
8057    MAX-ACCESS   read-create
8058    STATUS       current
8059    DESCRIPTION
8060        "The value of tmnxFPNetIngQGrpRowStatus allows entries to be
8061        created and deleted in the tmnxFPNetIngQGrpTable.
8062
8063        The creation of an entry in this table will succeed only if the
8064        queue-group being created exists in
8065        TIMETRA-QOS-MIB::tQosIngQGroupTable."
8066    REFERENCE
8067        "See definition of RowStatus in RFC 2579, 'Textual Conventions for
8068         SMIv2.'"
8069    ::= { tmnxFPNetIngQGrpEntry 3 }
8070
8071tmnxFPNetIngQGrpLastChgd OBJECT-TYPE
8072    SYNTAX       TimeStamp
8073    MAX-ACCESS   read-only
8074    STATUS       current
8075    DESCRIPTION
8076        "The value of tmnxFPNetIngQGrpLastChgd indicates the value of
8077        sysUpTime when the queue entry was last modified."
8078    ::= { tmnxFPNetIngQGrpEntry 4 }
8079
8080tmnxFPNetIngQGrpAcctgPolId OBJECT-TYPE
8081    SYNTAX       Unsigned32 (0..99)
8082    MAX-ACCESS   read-create
8083    STATUS       current
8084    DESCRIPTION
8085        "The value of tmnxFPNetIngQGrpAcctgPolId specifies the accounting-policy
8086        to be used with this forwarding-plane ingress queue-group.
8087
8088        A non-zero value indicates the tmnxLogApPolicyId index identifying the
8089        policy entry in the tmnxLogApTable from the TIMETRA-LOG-MIB which is
8090        associated with this queue-group.
8091
8092        The value zero indicates that the agent should use the default
8093        accounting policy, if one exists."
8094    DEFVAL { 0 }
8095    ::= { tmnxFPNetIngQGrpEntry 5 }
8096
8097tmnxFPNetIngQGrpCollectStats OBJECT-TYPE
8098    SYNTAX       TruthValue
8099    MAX-ACCESS   read-create
8100    STATUS       current
8101    DESCRIPTION
8102        "The value of tmnxFPNetIngQGrpCollectStats specifies whether
8103        statistics should be collected on this forwarding-plane ingress
8104        queue-group."
8105    DEFVAL { false }
8106    ::= { tmnxFPNetIngQGrpEntry 6 }
8107
8108tmnxFPNetIngQGrpDescr OBJECT-TYPE
8109    SYNTAX       TItemDescription
8110    MAX-ACCESS   read-create
8111    STATUS       current
8112    DESCRIPTION
8113        "The value of tmnxFPNetIngQGrpDescr specifies the description for
8114        this forwarding-plane queue-group."
8115    DEFVAL { ''H }
8116    ::= { tmnxFPNetIngQGrpEntry 7 }
8117
8118tmnxFPNetIngQGrpPolicerPol OBJECT-TYPE
8119    SYNTAX       TNamedItemOrEmpty
8120    MAX-ACCESS   read-create
8121    STATUS       current
8122    DESCRIPTION
8123        "The value of tmnxFPNetIngQGrpPolicerPol specifies the name of
8124        the policer control policy to be used with this forwarding-plane ingress
8125        queue-group."
8126    DEFVAL { ''H }
8127    ::= { tmnxFPNetIngQGrpEntry 8 }
8128
8129-- ----------------------------------------
8130-- FP Network Ingress QoS Queue Group Policer Statistics Table
8131-- ----------------------------------------
8132tmnxFPNetIngQGrpPStatTable OBJECT-TYPE
8133    SYNTAX          SEQUENCE OF TmnxFPNetIngQGrpPStatEntry
8134    MAX-ACCESS      not-accessible
8135    STATUS          current
8136    DESCRIPTION
8137        "The value of tmnxFPNetIngQGrpTable contains forwarding-plane ingress
8138         QoS queue group policer statistics on network side."
8139    ::= { tmnxCardObjs 27 }
8140
8141tmnxFPNetIngQGrpPStatEntry OBJECT-TYPE
8142    SYNTAX          TmnxFPNetIngQGrpPStatEntry
8143    MAX-ACCESS      not-accessible
8144    STATUS          current
8145    DESCRIPTION
8146        "The value of tmnxFPNetIngQGrpPStatEntry defines an entry in the
8147        tmnxFPNetIngQGrpPStatTable. It represents statistics about a
8148        specific QoS ingress queue group policer."
8149    INDEX           { tmnxChassisIndex, tmnxCardSlotNum, tmnxFPNum,
8150                      tmnxFPNetIngQGrpName, tmnxFPNetIngQGrpInstanceId,
8151                      tmnxFPNetIngQGrpPStatPolicerId }
8152    ::= { tmnxFPNetIngQGrpPStatTable 1 }
8153
8154TmnxFPNetIngQGrpPStatEntry ::=
8155    SEQUENCE {
8156        tmnxFPNetIngQGrpPStatPolicerId         TIngPolicerId,
8157        tmnxFPNetIngQGrpPStatMode              TmnxIngPolicerStatMode,
8158        tmnxFPNetIngQgPStOffHPrioPkts          Counter64,
8159        tmnxFPNetIngQgPStOffHPrioPktsL         Counter32,
8160        tmnxFPNetIngQgPStOffHPrioPktsH         Counter32,
8161        tmnxFPNetIngQgPStDrpHPrioPkts          Counter64,
8162        tmnxFPNetIngQgPStDrpHPrioPktsL         Counter32,
8163        tmnxFPNetIngQgPStDrpHPrioPktsH         Counter32,
8164        tmnxFPNetIngQgPStOffLPrioPkts          Counter64,
8165        tmnxFPNetIngQgPStOffLPrioPktsL         Counter32,
8166        tmnxFPNetIngQgPStOffLPrioPktsH         Counter32,
8167        tmnxFPNetIngQgPStDrpLPrioPkts          Counter64,
8168        tmnxFPNetIngQgPStDrpLPrioPktsL         Counter32,
8169        tmnxFPNetIngQgPStDrpLPrioPktsH         Counter32,
8170        tmnxFPNetIngQgPStOffHPrioOcts          Counter64,
8171        tmnxFPNetIngQgPStOffHPrioOctsL         Counter32,
8172        tmnxFPNetIngQgPStOffHPrioOctsH         Counter32,
8173        tmnxFPNetIngQgPStDrpHPrioOcts          Counter64,
8174        tmnxFPNetIngQgPStDrpHPrioOctsL         Counter32,
8175        tmnxFPNetIngQgPStDrpHPrioOctsH         Counter32,
8176        tmnxFPNetIngQgPStOffLPrioOcts          Counter64,
8177        tmnxFPNetIngQgPStOffLPrioOctsL         Counter32,
8178        tmnxFPNetIngQgPStOffLPrioOctsH         Counter32,
8179        tmnxFPNetIngQgPStDrpLPrioOcts          Counter64,
8180        tmnxFPNetIngQgPStDrpLPrioOctsL         Counter32,
8181        tmnxFPNetIngQgPStDrpLPrioOctsH         Counter32,
8182        tmnxFPNetIngQgPStFwdInProfPkts         Counter64,
8183        tmnxFPNetIngQgPStFwdInProfPktsL        Counter32,
8184        tmnxFPNetIngQgPStFwdInProfPktsH        Counter32,
8185        tmnxFPNetIngQgPStFwdOutProfPkts        Counter64,
8186        tmnxFPNetIngQgPStFwdOutProfPktsL       Counter32,
8187        tmnxFPNetIngQgPStFwdOutProfPktsH       Counter32,
8188        tmnxFPNetIngQgPStFwdInProfOcts         Counter64,
8189        tmnxFPNetIngQgPStFwdInProfOctsL        Counter32,
8190        tmnxFPNetIngQgPStFwdInProfOctsH        Counter32,
8191        tmnxFPNetIngQgPStFwdOutProfOcts        Counter64,
8192        tmnxFPNetIngQgPStFwdOutProfOctsL       Counter32,
8193        tmnxFPNetIngQgPStFwdOutProfOctsH       Counter32,
8194        tmnxFPNetIngQgPStUncolPktsOff          Counter64,
8195        tmnxFPNetIngQgPStUncolPktsOffL         Counter32,
8196        tmnxFPNetIngQgPStUncolPktsOffH         Counter32,
8197        tmnxFPNetIngQgPStUncolOctsOff          Counter64,
8198        tmnxFPNetIngQgPStUncolOctsOffL         Counter32,
8199        tmnxFPNetIngQgPStUncolOctsOffH         Counter32
8200    }
8201
8202tmnxFPNetIngQGrpPStatPolicerId OBJECT-TYPE
8203    SYNTAX          TIngPolicerId
8204    MAX-ACCESS      not-accessible
8205    STATUS          current
8206    DESCRIPTION
8207        "The value of tmnxFPNetIngQGrpPStatPolicerId specifies the index of the
8208         ingress QoS policer of this fowarding-plane queue group on network."
8209    ::= { tmnxFPNetIngQGrpPStatEntry 1 }
8210
8211tmnxFPNetIngQGrpPStatMode OBJECT-TYPE
8212    SYNTAX      TmnxIngPolicerStatMode
8213    MAX-ACCESS  read-only
8214    STATUS      current
8215    DESCRIPTION
8216        "The value of tmnxFPNetIngQGrpPStatMode indicates the stat mode used by
8217         this policer."
8218    ::= { tmnxFPNetIngQGrpPStatEntry 2 }
8219
8220tmnxFPNetIngQgPStOffHPrioPkts OBJECT-TYPE
8221    SYNTAX          Counter64
8222    MAX-ACCESS      read-only
8223    STATUS          current
8224    DESCRIPTION
8225       "The value of tmnxFPNetIngQgPStOffHPrioPkts indicates the number of
8226        high priority packets, as determined by the ingress queue group policer,
8227        offered by the Pchip to the Qchip."
8228    ::= { tmnxFPNetIngQGrpPStatEntry 3 }
8229
8230tmnxFPNetIngQgPStOffHPrioPktsL OBJECT-TYPE
8231    SYNTAX          Counter32
8232    MAX-ACCESS      read-only
8233    STATUS          current
8234    DESCRIPTION
8235       "The value of tmnxFPNetIngQgPStOffHPrioPktsL indicates the lower 32
8236        bits of tmnxFPNetIngQgPStOffHPrioPkts."
8237    ::= { tmnxFPNetIngQGrpPStatEntry 4 }
8238
8239tmnxFPNetIngQgPStOffHPrioPktsH OBJECT-TYPE
8240    SYNTAX          Counter32
8241    MAX-ACCESS      read-only
8242    STATUS          current
8243    DESCRIPTION
8244       "The value of tmnxFPNetIngQgPStOffHPrioPktsH indicates the upper 32
8245        bits of tmnxFPNetIngQgPStOffHPrioPkts."
8246    ::= { tmnxFPNetIngQGrpPStatEntry 5 }
8247
8248tmnxFPNetIngQgPStDrpHPrioPkts OBJECT-TYPE
8249    SYNTAX          Counter64
8250    MAX-ACCESS      read-only
8251    STATUS          current
8252    DESCRIPTION
8253       "The value of tmnxFPNetIngQgPStDrpHPrioPkts indicates the number of
8254        high priority packets, as determined by the ingress queue group policer,
8255        dropped by the Pchip due to: MBS exceeded, buffer pool limit exceeded,
8256        etc."
8257    ::= { tmnxFPNetIngQGrpPStatEntry 6 }
8258
8259tmnxFPNetIngQgPStDrpHPrioPktsL OBJECT-TYPE
8260    SYNTAX          Counter32
8261    MAX-ACCESS      read-only
8262    STATUS          current
8263    DESCRIPTION
8264       "The value of tmnxFPNetIngQgPStDrpHPrioPktsL indicates the lower 32
8265        bits of tmnxFPNetIngQgPStDrpHPrioPkts."
8266    ::= { tmnxFPNetIngQGrpPStatEntry 7 }
8267
8268tmnxFPNetIngQgPStDrpHPrioPktsH OBJECT-TYPE
8269    SYNTAX          Counter32
8270    MAX-ACCESS      read-only
8271    STATUS          current
8272    DESCRIPTION
8273       "The value of tmnxFPNetIngQgPStDrpHPrioPktsH indicates the upper 32
8274        bits of tmnxFPNetIngQgPStDrpHPrioPkts."
8275    ::= { tmnxFPNetIngQGrpPStatEntry 8 }
8276
8277tmnxFPNetIngQgPStOffLPrioPkts OBJECT-TYPE
8278    SYNTAX          Counter64
8279    MAX-ACCESS      read-only
8280    STATUS          current
8281    DESCRIPTION
8282       "The value of tmnxFPNetIngQgPStOffLPrioPkts indicates the number of
8283        low priority packets, as determined by the ingress queue group policer,
8284        offered by the Pchip to the Qchip."
8285    ::= { tmnxFPNetIngQGrpPStatEntry 9 }
8286
8287tmnxFPNetIngQgPStOffLPrioPktsL OBJECT-TYPE
8288    SYNTAX          Counter32
8289    MAX-ACCESS      read-only
8290    STATUS          current
8291    DESCRIPTION
8292       "The value of tmnxFPNetIngQgPStOffLPrioPktsL indicates the lower 32
8293        bits of tmnxFPNetIngQgPStOffLPrioPkts."
8294    ::= { tmnxFPNetIngQGrpPStatEntry 10 }
8295
8296tmnxFPNetIngQgPStOffLPrioPktsH OBJECT-TYPE
8297    SYNTAX          Counter32
8298    MAX-ACCESS      read-only
8299    STATUS          current
8300    DESCRIPTION
8301       "The value of tmnxFPNetIngQgPStOffLPrioPktsH indicates the upper 32
8302        bits of tmnxFPNetIngQgPStOffLPrioPkts."
8303    ::= { tmnxFPNetIngQGrpPStatEntry 11 }
8304
8305tmnxFPNetIngQgPStDrpLPrioPkts OBJECT-TYPE
8306    SYNTAX          Counter64
8307    MAX-ACCESS      read-only
8308    STATUS          current
8309    DESCRIPTION
8310       "The value of tmnxFPNetIngQgPStDrpLPrioPkts indicates the number of
8311        low priority packets, as determined by the ingress queue group policer,
8312        dropped by the Pchip due to: MBS exceeded, buffer pool limit exceeded,
8313        etc."
8314    ::= { tmnxFPNetIngQGrpPStatEntry 12 }
8315
8316tmnxFPNetIngQgPStDrpLPrioPktsL OBJECT-TYPE
8317    SYNTAX          Counter32
8318    MAX-ACCESS      read-only
8319    STATUS          current
8320    DESCRIPTION
8321       "The value of tmnxFPNetIngQgPStDrpLPrioPktsL indicates the lower 32
8322        bits of tmnxFPNetIngQgPStDrpLPrioPkts."
8323    ::= { tmnxFPNetIngQGrpPStatEntry 13 }
8324
8325tmnxFPNetIngQgPStDrpLPrioPktsH OBJECT-TYPE
8326    SYNTAX          Counter32
8327    MAX-ACCESS      read-only
8328    STATUS          current
8329    DESCRIPTION
8330       "The value of tmnxFPNetIngQgPStDrpLPrioPktsH indicates the upper 32
8331        bits of tmnxFPNetIngQgPStDrpLPrioPkts."
8332    ::= { tmnxFPNetIngQGrpPStatEntry 14 }
8333
8334tmnxFPNetIngQgPStOffHPrioOcts OBJECT-TYPE
8335    SYNTAX          Counter64
8336    MAX-ACCESS      read-only
8337    STATUS          current
8338    DESCRIPTION
8339       "The value of tmnxFPNetIngQgPStOffHPrioOcts indicates the number of
8340        high priority octets, as determined by the ingress queue group policer,
8341        offered by the Pchip to the Qchip."
8342    ::= { tmnxFPNetIngQGrpPStatEntry 15 }
8343
8344tmnxFPNetIngQgPStOffHPrioOctsL OBJECT-TYPE
8345    SYNTAX          Counter32
8346    MAX-ACCESS      read-only
8347    STATUS          current
8348    DESCRIPTION
8349       "The value of tmnxFPNetIngQgPStOffHPrioOctsL indicates the lower 32
8350        bits of tmnxFPNetIngQgPStOffHPrioOcts."
8351    ::= { tmnxFPNetIngQGrpPStatEntry 16 }
8352
8353tmnxFPNetIngQgPStOffHPrioOctsH OBJECT-TYPE
8354    SYNTAX          Counter32
8355    MAX-ACCESS      read-only
8356    STATUS          current
8357    DESCRIPTION
8358       "The value of tmnxFPNetIngQgPStOffHPrioOctsH indicates the upper 32
8359        bits of tmnxFPNetIngQgPStOffHPrioOcts."
8360    ::= { tmnxFPNetIngQGrpPStatEntry 17 }
8361
8362tmnxFPNetIngQgPStDrpHPrioOcts OBJECT-TYPE
8363    SYNTAX          Counter64
8364    MAX-ACCESS      read-only
8365    STATUS          current
8366    DESCRIPTION
8367       "The value of tmnxFPNetIngQgPStDrpHPrioOcts indicates the number of
8368        high priority octets, as determined by the ingress queue group policer,
8369        dropped by the Pchip due to: MBS exceeded, buffer pool limit exceeded,
8370        etc."
8371    ::= { tmnxFPNetIngQGrpPStatEntry 18 }
8372
8373tmnxFPNetIngQgPStDrpHPrioOctsL OBJECT-TYPE
8374    SYNTAX          Counter32
8375    MAX-ACCESS      read-only
8376    STATUS          current
8377    DESCRIPTION
8378       "The value of tmnxFPNetIngQgPStDrpHPrioOctsL indicates the lower 32
8379        bits of tmnxFPNetIngQgPStDrpHPrioOcts."
8380    ::= { tmnxFPNetIngQGrpPStatEntry 19 }
8381
8382tmnxFPNetIngQgPStDrpHPrioOctsH OBJECT-TYPE
8383    SYNTAX          Counter32
8384    MAX-ACCESS      read-only
8385    STATUS          current
8386    DESCRIPTION
8387       "The value of tmnxFPNetIngQgPStDrpHPrioOctsH indicates the upper 32
8388        bits of tmnxFPNetIngQgPStDrpHPrioOcts."
8389    ::= { tmnxFPNetIngQGrpPStatEntry 20}
8390
8391tmnxFPNetIngQgPStOffLPrioOcts OBJECT-TYPE
8392    SYNTAX          Counter64
8393    MAX-ACCESS      read-only
8394    STATUS          current
8395    DESCRIPTION
8396       "The value of tmnxFPNetIngQgPStOffLPrioOcts indicates the number of
8397        low priority octets, as determined by the ingress queue group policer,
8398        offered by the Pchip to the Pchip."
8399    ::= { tmnxFPNetIngQGrpPStatEntry 21 }
8400
8401tmnxFPNetIngQgPStOffLPrioOctsL OBJECT-TYPE
8402    SYNTAX          Counter32
8403    MAX-ACCESS      read-only
8404    STATUS          current
8405    DESCRIPTION
8406       "The value of tmnxFPNetIngQgPStOffLPrioOctsL indicates the lower 32
8407        bits of tmnxFPNetIngQgPStOffLPrioOcts."
8408    ::= { tmnxFPNetIngQGrpPStatEntry 22 }
8409
8410tmnxFPNetIngQgPStOffLPrioOctsH OBJECT-TYPE
8411    SYNTAX          Counter32
8412    MAX-ACCESS      read-only
8413    STATUS          current
8414    DESCRIPTION
8415       "The value of tmnxFPNetIngQgPStOffLPrioOctsH indicates the upper 32
8416        bits of tmnxFPNetIngQgPStOffLPrioOcts."
8417    ::= { tmnxFPNetIngQGrpPStatEntry 23 }
8418
8419tmnxFPNetIngQgPStDrpLPrioOcts OBJECT-TYPE
8420    SYNTAX          Counter64
8421    MAX-ACCESS      read-only
8422    STATUS          current
8423    DESCRIPTION
8424       "The value of tmnxFPNetIngQgPStDrpLPrioOcts indicates the number of
8425        low priority octets, as determined by the ingress queue group policer,
8426        dropped by the Pchip due to: MBS exceeded, buffer pool limit exceeded,
8427        etc."
8428    ::= { tmnxFPNetIngQGrpPStatEntry 24 }
8429
8430tmnxFPNetIngQgPStDrpLPrioOctsL OBJECT-TYPE
8431    SYNTAX          Counter32
8432    MAX-ACCESS      read-only
8433    STATUS          current
8434    DESCRIPTION
8435       "The value of tmnxFPNetIngQgPStDrpLPrioOctsL indicates the lower 32
8436        bits of tmnxFPNetIngQgPStDrpLPrioOcts."
8437    ::= { tmnxFPNetIngQGrpPStatEntry 25 }
8438
8439tmnxFPNetIngQgPStDrpLPrioOctsH OBJECT-TYPE
8440    SYNTAX          Counter32
8441    MAX-ACCESS      read-only
8442    STATUS          current
8443    DESCRIPTION
8444       "The value of tmnxFPNetIngQgPStDrpLPrioOctsH indicates the upper 32
8445        bits of tmnxFPNetIngQgPStDrpLPrioOcts."
8446    ::= { tmnxFPNetIngQGrpPStatEntry 26 }
8447
8448tmnxFPNetIngQgPStFwdInProfPkts OBJECT-TYPE
8449    SYNTAX          Counter64
8450    MAX-ACCESS      read-only
8451    STATUS          current
8452    DESCRIPTION
8453       "The value of tmnxFPNetIngQgPStFwdInProfPkts indicates the number of
8454        in-profile packets (rate below CIR) forwarded by the ingress Pchip."
8455    ::= { tmnxFPNetIngQGrpPStatEntry 27 }
8456
8457tmnxFPNetIngQgPStFwdInProfPktsL OBJECT-TYPE
8458    SYNTAX          Counter32
8459    MAX-ACCESS      read-only
8460    STATUS          current
8461    DESCRIPTION
8462       "The value of tmnxFPNetIngQgPStFwdInProfPktsL indicates the lower 32
8463        bits of tmnxFPNetIngQgPStFwdInProfPkts."
8464    ::= { tmnxFPNetIngQGrpPStatEntry 28 }
8465
8466tmnxFPNetIngQgPStFwdInProfPktsH OBJECT-TYPE
8467    SYNTAX          Counter32
8468    MAX-ACCESS      read-only
8469    STATUS          current
8470    DESCRIPTION
8471       "The value of tmnxFPNetIngQgPStFwdInProfPktsH indicates the upper 32
8472        bits of tmnxFPNetIngQgPStFwdInProfPkts."
8473    ::= { tmnxFPNetIngQGrpPStatEntry 29 }
8474
8475tmnxFPNetIngQgPStFwdOutProfPkts OBJECT-TYPE
8476    SYNTAX          Counter64
8477    MAX-ACCESS      read-only
8478    STATUS          current
8479    DESCRIPTION
8480       "The value of tmnxFPNetIngQgPStFwdOutProfPkts indicates the number of
8481        out-of-profile packets (rate above CIR) forwarded by the ingress Pchip."
8482    ::= { tmnxFPNetIngQGrpPStatEntry 30 }
8483
8484tmnxFPNetIngQgPStFwdOutProfPktsL OBJECT-TYPE
8485    SYNTAX          Counter32
8486    MAX-ACCESS      read-only
8487    STATUS          current
8488    DESCRIPTION
8489       "The value of tmnxFPNetIngQgPStFwdOutProfPktsL indicates the lower
8490        32 bits of tmnxFPNetIngQgPStFwdOutProfPkts."
8491    ::= { tmnxFPNetIngQGrpPStatEntry 31 }
8492
8493tmnxFPNetIngQgPStFwdOutProfPktsH OBJECT-TYPE
8494    SYNTAX          Counter32
8495    MAX-ACCESS      read-only
8496    STATUS          current
8497    DESCRIPTION
8498       "The value of tmnxFPNetIngQgPStFwdOutProfPktsH indicates the upper
8499        32 bits of tmnxFPNetIngQgPStFwdOutProfPkts."
8500    ::= { tmnxFPNetIngQGrpPStatEntry 32 }
8501
8502tmnxFPNetIngQgPStFwdInProfOcts OBJECT-TYPE
8503    SYNTAX          Counter64
8504    MAX-ACCESS      read-only
8505    STATUS          current
8506    DESCRIPTION
8507       "The value of tmnxFPNetIngQgPStFwdInProfOcts indicates the number of
8508        in-profile octets (rate below CIR) forwarded by the ingress Pchip."
8509    ::= { tmnxFPNetIngQGrpPStatEntry 33 }
8510
8511tmnxFPNetIngQgPStFwdInProfOctsL OBJECT-TYPE
8512    SYNTAX          Counter32
8513    MAX-ACCESS      read-only
8514    STATUS          current
8515    DESCRIPTION
8516       "The value of tmnxFPNetIngQgPStFwdInProfOctsL indicates the lower 32
8517        bits of tmnxFPNetIngQgPStFwdInProfOcts."
8518    ::= { tmnxFPNetIngQGrpPStatEntry 34 }
8519
8520tmnxFPNetIngQgPStFwdInProfOctsH OBJECT-TYPE
8521    SYNTAX          Counter32
8522    MAX-ACCESS      read-only
8523    STATUS          current
8524    DESCRIPTION
8525       "The value of tmnxFPNetIngQgPStFwdInProfOctsH indicates the upper 32
8526        bits of tmnxFPNetIngQgPStFwdInProfOcts."
8527    ::= { tmnxFPNetIngQGrpPStatEntry 35 }
8528
8529tmnxFPNetIngQgPStFwdOutProfOcts OBJECT-TYPE
8530    SYNTAX          Counter64
8531    MAX-ACCESS      read-only
8532    STATUS          current
8533    DESCRIPTION
8534       "The value of tmnxFPNetIngQgPStFwdOutProfOcts indicates the number of
8535        out-of-profile octets (rate above CIR) forwarded by the ingress Pchip."
8536    ::= { tmnxFPNetIngQGrpPStatEntry 36 }
8537
8538tmnxFPNetIngQgPStFwdOutProfOctsL OBJECT-TYPE
8539    SYNTAX          Counter32
8540    MAX-ACCESS      read-only
8541    STATUS          current
8542    DESCRIPTION
8543       "The value of tmnxFPNetIngQgPStFwdOutProfOctsL indicates the lower
8544        32 bits of tmnxFPNetIngQgPStFwdOutProfOcts."
8545    ::= { tmnxFPNetIngQGrpPStatEntry 37 }
8546
8547tmnxFPNetIngQgPStFwdOutProfOctsH OBJECT-TYPE
8548    SYNTAX          Counter32
8549    MAX-ACCESS      read-only
8550    STATUS          current
8551    DESCRIPTION
8552       "The value of tmnxFPNetIngQgPStFwdOutProfOctsH indicates the upper
8553        32 bits of tmnxFPNetIngQgPStFwdOutProfOcts."
8554    ::= { tmnxFPNetIngQGrpPStatEntry 38 }
8555
8556tmnxFPNetIngQgPStUncolPktsOff OBJECT-TYPE
8557    SYNTAX          Counter64
8558    MAX-ACCESS      read-only
8559    STATUS          current
8560    DESCRIPTION
8561       "The value of tmnxFPNetIngQgPStUncolPktsOff indicates the number of
8562        uncolored packets offered to the ingress Pchip."
8563    ::= { tmnxFPNetIngQGrpPStatEntry 39 }
8564
8565tmnxFPNetIngQgPStUncolPktsOffL OBJECT-TYPE
8566    SYNTAX          Counter32
8567    MAX-ACCESS      read-only
8568    STATUS          current
8569    DESCRIPTION
8570       "The value of tmnxFPNetIngQgPStUncolPktsOffL indicates the lower 32
8571        bits of tmnxFPNetIngQgPStUncolPktsOff."
8572    ::= { tmnxFPNetIngQGrpPStatEntry 40 }
8573
8574tmnxFPNetIngQgPStUncolPktsOffH OBJECT-TYPE
8575    SYNTAX          Counter32
8576    MAX-ACCESS      read-only
8577    STATUS          current
8578    DESCRIPTION
8579       "The value of tmnxFPNetIngQgPStUncolPktsOffH indicates the upper 32
8580        bits of tmnxFPNetIngQgPStUncolPktsOff."
8581    ::= { tmnxFPNetIngQGrpPStatEntry 41 }
8582
8583tmnxFPNetIngQgPStUncolOctsOff OBJECT-TYPE
8584    SYNTAX          Counter64
8585    MAX-ACCESS      read-only
8586    STATUS          current
8587    DESCRIPTION
8588       "The value of tmnxFPNetIngQgPStUncolOctsOff indicates the number of
8589        uncolored octets offered to the ingress Pchip."
8590    ::= { tmnxFPNetIngQGrpPStatEntry 42 }
8591
8592tmnxFPNetIngQgPStUncolOctsOffL OBJECT-TYPE
8593    SYNTAX          Counter32
8594    MAX-ACCESS      read-only
8595    STATUS          current
8596    DESCRIPTION
8597        "The value of tmnxFPNetIngQgPStUncolOctsOffL indicates the lower
8598         32 bits of tmnxFPNetIngQgPStUncolOctsOff."
8599    ::= { tmnxFPNetIngQGrpPStatEntry 43 }
8600
8601tmnxFPNetIngQgPStUncolOctsOffH OBJECT-TYPE
8602    SYNTAX          Counter32
8603    MAX-ACCESS      read-only
8604    STATUS          current
8605    DESCRIPTION
8606        "The value of tmnxFPNetIngQgPStUncolOctsOffH indicates the higher
8607         32 bits of the value of tmnxFPNetIngQgPStUncolOctsOff."
8608    ::= { tmnxFPNetIngQGrpPStatEntry 44 }
8609
8610-- ----------------------------------------
8611-- FP Access Ingress QoS Queue Group Policer Statistics Table
8612-- ----------------------------------------
8613tmnxFPAccIngQGrpPStatTable OBJECT-TYPE
8614    SYNTAX          SEQUENCE OF TmnxFPAccIngQGrpPStatEntry
8615    MAX-ACCESS      not-accessible
8616    STATUS          current
8617    DESCRIPTION
8618        "The value of tmnxFPAccIngQGrpTable contains forwarding-plane ingress
8619         QoS queue group policer statistics on access side."
8620    ::= { tmnxCardObjs 28 }
8621
8622tmnxFPAccIngQGrpPStatEntry OBJECT-TYPE
8623    SYNTAX          TmnxFPAccIngQGrpPStatEntry
8624    MAX-ACCESS      not-accessible
8625    STATUS          current
8626    DESCRIPTION
8627        "The value of tmnxFPAccIngQGrpPStatEntry defines an entry in the
8628        tmnxFPAccIngQGrpPStatTable. It represents statistics about a
8629        specific QoS ingress queue group policer."
8630    INDEX           { tmnxChassisIndex, tmnxCardSlotNum, tmnxFPNum,
8631                      tmnxFPAccIngQGrpName, tmnxFPAccIngQGrpInstanceId,
8632                      tmnxFPAccIngQGrpPStatPolicerId }
8633    ::= { tmnxFPAccIngQGrpPStatTable 1 }
8634
8635TmnxFPAccIngQGrpPStatEntry ::=
8636    SEQUENCE {
8637        tmnxFPAccIngQGrpPStatPolicerId         TIngPolicerId,
8638        tmnxFPAccIngQGrpPStatMode              TmnxIngPolicerStatMode,
8639        tmnxFPAccIngQgPStOffHPrioPkts          Counter64,
8640        tmnxFPAccIngQgPStOffHPrioPktsL         Counter32,
8641        tmnxFPAccIngQgPStOffHPrioPktsH         Counter32,
8642        tmnxFPAccIngQgPStDrpHPrioPkts          Counter64,
8643        tmnxFPAccIngQgPStDrpHPrioPktsL         Counter32,
8644        tmnxFPAccIngQgPStDrpHPrioPktsH         Counter32,
8645        tmnxFPAccIngQgPStOffLPrioPkts          Counter64,
8646        tmnxFPAccIngQgPStOffLPrioPktsL         Counter32,
8647        tmnxFPAccIngQgPStOffLPrioPktsH         Counter32,
8648        tmnxFPAccIngQgPStDrpLPrioPkts          Counter64,
8649        tmnxFPAccIngQgPStDrpLPrioPktsL         Counter32,
8650        tmnxFPAccIngQgPStDrpLPrioPktsH         Counter32,
8651        tmnxFPAccIngQgPStOffHPrioOcts          Counter64,
8652        tmnxFPAccIngQgPStOffHPrioOctsL         Counter32,
8653        tmnxFPAccIngQgPStOffHPrioOctsH         Counter32,
8654        tmnxFPAccIngQgPStDrpHPrioOcts          Counter64,
8655        tmnxFPAccIngQgPStDrpHPrioOctsL         Counter32,
8656        tmnxFPAccIngQgPStDrpHPrioOctsH         Counter32,
8657        tmnxFPAccIngQgPStOffLPrioOcts          Counter64,
8658        tmnxFPAccIngQgPStOffLPrioOctsL         Counter32,
8659        tmnxFPAccIngQgPStOffLPrioOctsH         Counter32,
8660        tmnxFPAccIngQgPStDrpLPrioOcts          Counter64,
8661        tmnxFPAccIngQgPStDrpLPrioOctsL         Counter32,
8662        tmnxFPAccIngQgPStDrpLPrioOctsH         Counter32,
8663        tmnxFPAccIngQgPStFwdInProfPkts         Counter64,
8664        tmnxFPAccIngQgPStFwdInProfPktsL        Counter32,
8665        tmnxFPAccIngQgPStFwdInProfPktsH        Counter32,
8666        tmnxFPAccIngQgPStFwdOutProfPkts        Counter64,
8667        tmnxFPAccIngQgPStFwdOutProfPktsL       Counter32,
8668        tmnxFPAccIngQgPStFwdOutProfPktsH       Counter32,
8669        tmnxFPAccIngQgPStFwdInProfOcts         Counter64,
8670        tmnxFPAccIngQgPStFwdInProfOctsL        Counter32,
8671        tmnxFPAccIngQgPStFwdInProfOctsH        Counter32,
8672        tmnxFPAccIngQgPStFwdOutProfOcts        Counter64,
8673        tmnxFPAccIngQgPStFwdOutProfOctsL       Counter32,
8674        tmnxFPAccIngQgPStFwdOutProfOctsH       Counter32,
8675        tmnxFPAccIngQgPStUncolPktsOff          Counter64,
8676        tmnxFPAccIngQgPStUncolPktsOffL         Counter32,
8677        tmnxFPAccIngQgPStUncolPktsOffH         Counter32,
8678        tmnxFPAccIngQgPStUncolOctsOff          Counter64,
8679        tmnxFPAccIngQgPStUncolOctsOffL         Counter32,
8680        tmnxFPAccIngQgPStUncolOctsOffH         Counter32
8681    }
8682
8683tmnxFPAccIngQGrpPStatPolicerId OBJECT-TYPE
8684    SYNTAX          TIngPolicerId
8685    MAX-ACCESS      not-accessible
8686    STATUS          current
8687    DESCRIPTION
8688        "The value of tmnxFPAccIngQGrpPStatPolicerId specifies the index of the
8689         ingress QoS policer of this forwarding-plane queue group on access."
8690    ::= { tmnxFPAccIngQGrpPStatEntry 1 }
8691
8692tmnxFPAccIngQGrpPStatMode OBJECT-TYPE
8693    SYNTAX      TmnxIngPolicerStatMode
8694    MAX-ACCESS  read-only
8695    STATUS      current
8696    DESCRIPTION
8697        "The value of tmnxFPAccIngQGrpPStatMode indicates the stat mode used by
8698         this policer."
8699    ::= { tmnxFPAccIngQGrpPStatEntry 2 }
8700
8701tmnxFPAccIngQgPStOffHPrioPkts OBJECT-TYPE
8702    SYNTAX          Counter64
8703    MAX-ACCESS      read-only
8704    STATUS          current
8705    DESCRIPTION
8706       "The value of tmnxFPAccIngQgPStOffHPrioPkts indicates the number of
8707        high priority packets, as determined by the ingress queue group policer,
8708        offered by the Pchip to the Qchip."
8709    ::= { tmnxFPAccIngQGrpPStatEntry 3 }
8710
8711tmnxFPAccIngQgPStOffHPrioPktsL OBJECT-TYPE
8712    SYNTAX          Counter32
8713    MAX-ACCESS      read-only
8714    STATUS          current
8715    DESCRIPTION
8716       "The value of tmnxFPAccIngQgPStOffHPrioPktsL indicates the lower 32
8717        bits of tmnxFPAccIngQgPStOffHPrioPkts."
8718    ::= { tmnxFPAccIngQGrpPStatEntry 4 }
8719
8720tmnxFPAccIngQgPStOffHPrioPktsH OBJECT-TYPE
8721    SYNTAX          Counter32
8722    MAX-ACCESS      read-only
8723    STATUS          current
8724    DESCRIPTION
8725       "The value of tmnxFPAccIngQgPStOffHPrioPktsH indicates the upper 32
8726        bits of tmnxFPAccIngQgPStOffHPrioPkts."
8727    ::= { tmnxFPAccIngQGrpPStatEntry 5 }
8728
8729tmnxFPAccIngQgPStDrpHPrioPkts OBJECT-TYPE
8730    SYNTAX          Counter64
8731    MAX-ACCESS      read-only
8732    STATUS          current
8733    DESCRIPTION
8734       "The value of tmnxFPAccIngQgPStDrpHPrioPkts indicates the number of
8735        high priority packets, as determined by the ingress queue group policer,
8736        dropped by the Pchip due to: MBS exceeded, buffer pool limit exceeded,
8737        etc."
8738    ::= { tmnxFPAccIngQGrpPStatEntry 6 }
8739
8740tmnxFPAccIngQgPStDrpHPrioPktsL OBJECT-TYPE
8741    SYNTAX          Counter32
8742    MAX-ACCESS      read-only
8743    STATUS          current
8744    DESCRIPTION
8745       "The value of tmnxFPAccIngQgPStDrpHPrioPktsL indicates the lower 32
8746        bits of tmnxFPAccIngQgPStDrpHPrioPkts."
8747    ::= { tmnxFPAccIngQGrpPStatEntry 7 }
8748
8749tmnxFPAccIngQgPStDrpHPrioPktsH OBJECT-TYPE
8750    SYNTAX          Counter32
8751    MAX-ACCESS      read-only
8752    STATUS          current
8753    DESCRIPTION
8754       "The value of tmnxFPAccIngQgPStDrpHPrioPktsH indicates the upper 32
8755        bits of tmnxFPAccIngQgPStDrpHPrioPkts."
8756    ::= { tmnxFPAccIngQGrpPStatEntry 8 }
8757
8758tmnxFPAccIngQgPStOffLPrioPkts OBJECT-TYPE
8759    SYNTAX          Counter64
8760    MAX-ACCESS      read-only
8761    STATUS          current
8762    DESCRIPTION
8763       "The value of tmnxFPAccIngQgPStOffLPrioPkts indicates the number of
8764        low priority packets, as determined by the ingress queue group policer,
8765        offered by the Pchip to the Qchip."
8766    ::= { tmnxFPAccIngQGrpPStatEntry 9 }
8767
8768tmnxFPAccIngQgPStOffLPrioPktsL OBJECT-TYPE
8769    SYNTAX          Counter32
8770    MAX-ACCESS      read-only
8771    STATUS          current
8772    DESCRIPTION
8773       "The value of tmnxFPAccIngQgPStOffLPrioPktsL indicates the lower 32
8774        bits of tmnxFPAccIngQgPStOffLPrioPkts."
8775    ::= { tmnxFPAccIngQGrpPStatEntry 10 }
8776
8777tmnxFPAccIngQgPStOffLPrioPktsH OBJECT-TYPE
8778    SYNTAX          Counter32
8779    MAX-ACCESS      read-only
8780    STATUS          current
8781    DESCRIPTION
8782       "The value of tmnxFPAccIngQgPStOffLPrioPktsH indicates the upper 32
8783        bits of tmnxFPAccIngQgPStOffLPrioPkts."
8784    ::= { tmnxFPAccIngQGrpPStatEntry 11 }
8785
8786tmnxFPAccIngQgPStDrpLPrioPkts OBJECT-TYPE
8787    SYNTAX          Counter64
8788    MAX-ACCESS      read-only
8789    STATUS          current
8790    DESCRIPTION
8791       "The value of tmnxFPAccIngQgPStDrpLPrioPkts indicates the number of
8792        low priority packets, as determined by the ingress queue group policer,
8793        dropped by the Pchip due to: MBS exceeded, buffer pool limit exceeded,
8794        etc."
8795    ::= { tmnxFPAccIngQGrpPStatEntry 12 }
8796
8797tmnxFPAccIngQgPStDrpLPrioPktsL OBJECT-TYPE
8798    SYNTAX          Counter32
8799    MAX-ACCESS      read-only
8800    STATUS          current
8801    DESCRIPTION
8802       "The value of tmnxFPAccIngQgPStDrpLPrioPktsL indicates the lower 32
8803        bits of tmnxFPAccIngQgPStDrpLPrioPkts."
8804    ::= { tmnxFPAccIngQGrpPStatEntry 13 }
8805
8806tmnxFPAccIngQgPStDrpLPrioPktsH OBJECT-TYPE
8807    SYNTAX          Counter32
8808    MAX-ACCESS      read-only
8809    STATUS          current
8810    DESCRIPTION
8811       "The value of tmnxFPAccIngQgPStDrpLPrioPktsH indicates the upper 32
8812        bits of tmnxFPAccIngQgPStDrpLPrioPkts."
8813    ::= { tmnxFPAccIngQGrpPStatEntry 14 }
8814
8815tmnxFPAccIngQgPStOffHPrioOcts OBJECT-TYPE
8816    SYNTAX          Counter64
8817    MAX-ACCESS      read-only
8818    STATUS          current
8819    DESCRIPTION
8820       "The value of tmnxFPAccIngQgPStOffHPrioOcts indicates the number of
8821        high priority octets, as determined by the ingress queue group policer,
8822        offered by the Pchip to the Qchip."
8823    ::= { tmnxFPAccIngQGrpPStatEntry 15 }
8824
8825tmnxFPAccIngQgPStOffHPrioOctsL OBJECT-TYPE
8826    SYNTAX          Counter32
8827    MAX-ACCESS      read-only
8828    STATUS          current
8829    DESCRIPTION
8830       "The value of tmnxFPAccIngQgPStOffHPrioOctsL indicates the lower 32
8831        bits of tmnxFPAccIngQgPStOffHPrioOcts."
8832    ::= { tmnxFPAccIngQGrpPStatEntry 16 }
8833
8834tmnxFPAccIngQgPStOffHPrioOctsH OBJECT-TYPE
8835    SYNTAX          Counter32
8836    MAX-ACCESS      read-only
8837    STATUS          current
8838    DESCRIPTION
8839       "The value of tmnxFPAccIngQgPStOffHPrioOctsH indicates the upper 32
8840        bits of tmnxFPAccIngQgPStOffHPrioOcts."
8841    ::= { tmnxFPAccIngQGrpPStatEntry 17 }
8842
8843tmnxFPAccIngQgPStDrpHPrioOcts OBJECT-TYPE
8844    SYNTAX          Counter64
8845    MAX-ACCESS      read-only
8846    STATUS          current
8847    DESCRIPTION
8848       "The value of tmnxFPAccIngQgPStDrpHPrioOcts indicates the number of
8849        high priority octets, as determined by the ingress queue group policer,
8850        dropped by the Pchip due to: MBS exceeded, buffer pool limit exceeded,
8851        etc."
8852    ::= { tmnxFPAccIngQGrpPStatEntry 18 }
8853
8854tmnxFPAccIngQgPStDrpHPrioOctsL OBJECT-TYPE
8855    SYNTAX          Counter32
8856    MAX-ACCESS      read-only
8857    STATUS          current
8858    DESCRIPTION
8859       "The value of tmnxFPAccIngQgPStDrpHPrioOctsL indicates the lower 32
8860        bits of tmnxFPAccIngQgPStDrpHPrioOcts."
8861    ::= { tmnxFPAccIngQGrpPStatEntry 19 }
8862
8863tmnxFPAccIngQgPStDrpHPrioOctsH OBJECT-TYPE
8864    SYNTAX          Counter32
8865    MAX-ACCESS      read-only
8866    STATUS          current
8867    DESCRIPTION
8868       "The value of tmnxFPAccIngQgPStDrpHPrioOctsH indicates the upper 32
8869        bits of tmnxFPAccIngQgPStDrpHPrioOcts."
8870    ::= { tmnxFPAccIngQGrpPStatEntry 20 }
8871
8872tmnxFPAccIngQgPStOffLPrioOcts OBJECT-TYPE
8873    SYNTAX          Counter64
8874    MAX-ACCESS      read-only
8875    STATUS          current
8876    DESCRIPTION
8877       "The value of tmnxFPAccIngQgPStOffLPrioOcts indicates the number of
8878        low priority octets, as determined by the ingress queue group policer,
8879        offered by the Pchip to the Pchip."
8880    ::= { tmnxFPAccIngQGrpPStatEntry 21 }
8881
8882tmnxFPAccIngQgPStOffLPrioOctsL OBJECT-TYPE
8883    SYNTAX          Counter32
8884    MAX-ACCESS      read-only
8885    STATUS          current
8886    DESCRIPTION
8887       "The value of tmnxFPAccIngQgPStOffLPrioOctsL indicates the lower 32
8888        bits of tmnxFPAccIngQgPStOffLPrioOcts."
8889    ::= { tmnxFPAccIngQGrpPStatEntry 22 }
8890
8891tmnxFPAccIngQgPStOffLPrioOctsH OBJECT-TYPE
8892    SYNTAX          Counter32
8893    MAX-ACCESS      read-only
8894    STATUS          current
8895    DESCRIPTION
8896       "The value of tmnxFPAccIngQgPStOffLPrioOctsH indicates the upper 32
8897        bits of tmnxFPAccIngQgPStOffLPrioOcts."
8898    ::= { tmnxFPAccIngQGrpPStatEntry 23 }
8899
8900tmnxFPAccIngQgPStDrpLPrioOcts OBJECT-TYPE
8901    SYNTAX          Counter64
8902    MAX-ACCESS      read-only
8903    STATUS          current
8904    DESCRIPTION
8905       "The value of tmnxFPAccIngQgPStDrpLPrioOcts indicates the number of
8906        low priority octets, as determined by the ingress queue group policer,
8907        dropped by the Pchip due to: MBS exceeded, buffer pool limit exceeded,
8908        etc."
8909    ::= { tmnxFPAccIngQGrpPStatEntry 24 }
8910
8911tmnxFPAccIngQgPStDrpLPrioOctsL OBJECT-TYPE
8912    SYNTAX          Counter32
8913    MAX-ACCESS      read-only
8914    STATUS          current
8915    DESCRIPTION
8916       "The value of tmnxFPAccIngQgPStDrpLPrioOctsL indicates the lower 32
8917        bits of tmnxFPAccIngQgPStDrpLPrioOcts."
8918    ::= { tmnxFPAccIngQGrpPStatEntry 25 }
8919
8920tmnxFPAccIngQgPStDrpLPrioOctsH OBJECT-TYPE
8921    SYNTAX          Counter32
8922    MAX-ACCESS      read-only
8923    STATUS          current
8924    DESCRIPTION
8925       "The value of tmnxFPAccIngQgPStDrpLPrioOctsH indicates the upper 32
8926        bits of tmnxFPAccIngQgPStDrpLPrioOcts."
8927    ::= { tmnxFPAccIngQGrpPStatEntry 26 }
8928
8929tmnxFPAccIngQgPStFwdInProfPkts OBJECT-TYPE
8930    SYNTAX          Counter64
8931    MAX-ACCESS      read-only
8932    STATUS          current
8933    DESCRIPTION
8934       "The value of tmnxFPAccIngQgPStFwdInProfPkts indicates the number of
8935        in-profile packets (rate below CIR) forwarded by the ingress Pchip."
8936    ::= { tmnxFPAccIngQGrpPStatEntry 27 }
8937
8938tmnxFPAccIngQgPStFwdInProfPktsL OBJECT-TYPE
8939    SYNTAX          Counter32
8940    MAX-ACCESS      read-only
8941    STATUS          current
8942    DESCRIPTION
8943       "The value of tmnxFPAccIngQgPStFwdInProfPktsL indicates the lower 32
8944        bits of tmnxFPAccIngQgPStFwdInProfPkts."
8945    ::= { tmnxFPAccIngQGrpPStatEntry 28 }
8946
8947tmnxFPAccIngQgPStFwdInProfPktsH OBJECT-TYPE
8948    SYNTAX          Counter32
8949    MAX-ACCESS      read-only
8950    STATUS          current
8951    DESCRIPTION
8952       "The value of tmnxFPAccIngQgPStFwdInProfPktsH indicates the upper 32
8953        bits of tmnxFPAccIngQgPStFwdInProfPkts."
8954    ::= { tmnxFPAccIngQGrpPStatEntry 29 }
8955
8956tmnxFPAccIngQgPStFwdOutProfPkts OBJECT-TYPE
8957    SYNTAX          Counter64
8958    MAX-ACCESS      read-only
8959    STATUS          current
8960    DESCRIPTION
8961       "The value of tmnxFPAccIngQgPStFwdOutProfPkts indicates the number of
8962        out-of-profile packets (rate above CIR) forwarded by the ingress Pchip."
8963    ::= { tmnxFPAccIngQGrpPStatEntry 30 }
8964
8965tmnxFPAccIngQgPStFwdOutProfPktsL OBJECT-TYPE
8966    SYNTAX          Counter32
8967    MAX-ACCESS      read-only
8968    STATUS          current
8969    DESCRIPTION
8970       "The value of tmnxFPAccIngQgPStFwdOutProfPktsL indicates the lower
8971        32 bits of tmnxFPAccIngQgPStFwdOutProfPkts."
8972    ::= { tmnxFPAccIngQGrpPStatEntry 31 }
8973
8974tmnxFPAccIngQgPStFwdOutProfPktsH OBJECT-TYPE
8975    SYNTAX          Counter32
8976    MAX-ACCESS      read-only
8977    STATUS          current
8978    DESCRIPTION
8979       "The value of tmnxFPAccIngQgPStFwdOutProfPktsH indicates the upper
8980        32 bits of tmnxFPAccIngQgPStFwdOutProfPkts."
8981    ::= { tmnxFPAccIngQGrpPStatEntry 32 }
8982
8983tmnxFPAccIngQgPStFwdInProfOcts OBJECT-TYPE
8984    SYNTAX          Counter64
8985    MAX-ACCESS      read-only
8986    STATUS          current
8987    DESCRIPTION
8988       "The value of tmnxFPAccIngQgPStFwdInProfOcts indicates the number of
8989        in-profile octets (rate below CIR) forwarded by the ingress Pchip."
8990    ::= { tmnxFPAccIngQGrpPStatEntry 33 }
8991
8992tmnxFPAccIngQgPStFwdInProfOctsL OBJECT-TYPE
8993    SYNTAX          Counter32
8994    MAX-ACCESS      read-only
8995    STATUS          current
8996    DESCRIPTION
8997       "The value of tmnxFPAccIngQgPStFwdInProfOctsL indicates the lower 32
8998        bits of tmnxFPAccIngQgPStFwdInProfOcts."
8999    ::= { tmnxFPAccIngQGrpPStatEntry 34 }
9000
9001tmnxFPAccIngQgPStFwdInProfOctsH OBJECT-TYPE
9002    SYNTAX          Counter32
9003    MAX-ACCESS      read-only
9004    STATUS          current
9005    DESCRIPTION
9006       "The value of tmnxFPAccIngQgPStFwdInProfOctsH indicates the upper 32
9007        bits of tmnxFPAccIngQgPStFwdInProfOcts."
9008    ::= { tmnxFPAccIngQGrpPStatEntry 35 }
9009
9010tmnxFPAccIngQgPStFwdOutProfOcts OBJECT-TYPE
9011    SYNTAX          Counter64
9012    MAX-ACCESS      read-only
9013    STATUS          current
9014    DESCRIPTION
9015       "The value of tmnxFPAccIngQgPStFwdOutProfOcts indicates the number of
9016        out-of-profile octets (rate above CIR) forwarded by the ingress Pchip."
9017    ::= { tmnxFPAccIngQGrpPStatEntry 36 }
9018
9019tmnxFPAccIngQgPStFwdOutProfOctsL OBJECT-TYPE
9020    SYNTAX          Counter32
9021    MAX-ACCESS      read-only
9022    STATUS          current
9023    DESCRIPTION
9024       "The value of tmnxFPAccIngQgPStFwdOutProfOctsL indicates the lower
9025        32 bits of tmnxFPAccIngQgPStFwdOutProfOcts."
9026    ::= { tmnxFPAccIngQGrpPStatEntry 37 }
9027
9028tmnxFPAccIngQgPStFwdOutProfOctsH OBJECT-TYPE
9029    SYNTAX          Counter32
9030    MAX-ACCESS      read-only
9031    STATUS          current
9032    DESCRIPTION
9033       "The value of tmnxFPAccIngQgPStFwdOutProfOctsH indicates the upper
9034        32 bits of tmnxFPAccIngQgPStFwdOutProfOcts."
9035    ::= { tmnxFPAccIngQGrpPStatEntry 38 }
9036
9037tmnxFPAccIngQgPStUncolPktsOff OBJECT-TYPE
9038    SYNTAX          Counter64
9039    MAX-ACCESS      read-only
9040    STATUS          current
9041    DESCRIPTION
9042       "The value of tmnxFPAccIngQgPStUncolPktsOff indicates the number of
9043        uncolored packets offered to the ingress Pchip."
9044    ::= { tmnxFPAccIngQGrpPStatEntry 39 }
9045
9046tmnxFPAccIngQgPStUncolPktsOffL OBJECT-TYPE
9047    SYNTAX          Counter32
9048    MAX-ACCESS      read-only
9049    STATUS          current
9050    DESCRIPTION
9051       "The value of tmnxFPAccIngQgPStUncolPktsOffL indicates the lower 32
9052        bits of tmnxFPAccIngQgPStUncolPktsOff."
9053    ::= { tmnxFPAccIngQGrpPStatEntry 40 }
9054
9055tmnxFPAccIngQgPStUncolPktsOffH OBJECT-TYPE
9056    SYNTAX          Counter32
9057    MAX-ACCESS      read-only
9058    STATUS          current
9059    DESCRIPTION
9060       "The value of tmnxFPAccIngQgPStUncolPktsOffH indicates the upper 32
9061        bits of tmnxFPAccIngQgPStUncolPktsOff."
9062    ::= { tmnxFPAccIngQGrpPStatEntry 41 }
9063
9064tmnxFPAccIngQgPStUncolOctsOff OBJECT-TYPE
9065    SYNTAX          Counter64
9066    MAX-ACCESS      read-only
9067    STATUS          current
9068    DESCRIPTION
9069       "The value of tmnxFPAccIngQgPStUncolOctsOff indicates the number of
9070        uncolored octets offered to the ingress Pchip."
9071    ::= { tmnxFPAccIngQGrpPStatEntry 42 }
9072
9073tmnxFPAccIngQgPStUncolOctsOffL OBJECT-TYPE
9074    SYNTAX          Counter32
9075    MAX-ACCESS      read-only
9076    STATUS          current
9077    DESCRIPTION
9078        "The value of tmnxFPAccIngQgPStUncolOctsOffL indicates the lower
9079         32 bits of tmnxFPAccIngQgPStUncolOctsOff."
9080    ::= { tmnxFPAccIngQGrpPStatEntry 43 }
9081
9082tmnxFPAccIngQgPStUncolOctsOffH OBJECT-TYPE
9083    SYNTAX          Counter32
9084    MAX-ACCESS      read-only
9085    STATUS          current
9086    DESCRIPTION
9087        "The value of tmnxFPAccIngQgPStUncolOctsOffH indicates the higher
9088         32 bits of the value of tmnxFPAccIngQgPStUncolOctsOff."
9089    ::= { tmnxFPAccIngQGrpPStatEntry 44 }
9090
9091
9092-- ----------------------------------------
9093-- FP Access Ingress Policer overrides Table
9094-- ----------------------------------------
9095
9096tFPAccIngQGrpPlcrOvrTblLstChgd OBJECT-TYPE
9097    SYNTAX       TimeStamp
9098    MAX-ACCESS   read-only
9099    STATUS       current
9100    DESCRIPTION
9101        "The value of tFPAccIngQGrpPlcrOvrTblLstChgd indicates the timestamp of
9102         last change to the tFPAccIngQGrpPlcrOvrTable."
9103    ::= { tmnxCardObjs 29 }
9104
9105tFPAccIngQGrpPlcrOvrTable OBJECT-TYPE
9106    SYNTAX          SEQUENCE OF TFPAccIngQGrpPlcrOvrEntry
9107    MAX-ACCESS      not-accessible
9108    STATUS          current
9109    DESCRIPTION
9110        "The value of tFPAccIngQGrpPlcrOvrTable contains forwarding-plane
9111         QoS ingress queue group policer overrides on access side."
9112    ::= { tmnxCardObjs 30 }
9113
9114tFPAccIngQGrpPlcrOvrEntry OBJECT-TYPE
9115    SYNTAX          TFPAccIngQGrpPlcrOvrEntry
9116    MAX-ACCESS      not-accessible
9117    STATUS          current
9118    DESCRIPTION
9119        "The value of tmnxFPAccIngQGrpPStatEntry defines an entry in the
9120         tFPAccIngQGrpPlcrOvrTable. It represents policer overrides about a
9121         specific forwarding-plane QoS ingress queue group policer."
9122    INDEX           { tmnxChassisIndex, tmnxCardSlotNum, tmnxFPNum,
9123                      tmnxFPAccIngQGrpName, tmnxFPAccIngQGrpInstanceId,
9124                      tFPAccIngQGrpPlcrOvrPolicerId }
9125    ::= { tFPAccIngQGrpPlcrOvrTable 1 }
9126
9127TFPAccIngQGrpPlcrOvrEntry ::=
9128    SEQUENCE {
9129         tFPAccIngQGrpPlcrOvrPolicerId    TIngPolicerId,
9130         tFPAccIngQGrpPlcrOvrRowStatus    RowStatus,
9131         tFPAccIngQGrpPlcrOvrLastChgd     TimeStamp,
9132         tFPAccIngQGrpPlcrOvrAdminPIR     THPolPIRRateOverride,
9133         tFPAccIngQGrpPlcrOvrAdminCIR     THPolCIRRateOverride,
9134         tFPAccIngQGrpPlcrOvrStatMode     TmnxIngPolicerStatModeOverride,
9135         tFPAccIngQGrpPlcrOvrMBS          TPlcrBurstSizeBytesOverride,
9136         tFPAccIngQGrpPlcrOvrCBS          TPlcrBurstSizeBytesOverride,
9137         tFPAccIngQGrpPlcrOvrPktOffset    TPerPacketOffsetOvr
9138    }
9139
9140tFPAccIngQGrpPlcrOvrPolicerId OBJECT-TYPE
9141    SYNTAX          TIngPolicerId
9142    MAX-ACCESS      not-accessible
9143    STATUS          current
9144    DESCRIPTION
9145        "The value of tFPAccIngQGrpPlcrOvrPolicerId specifies the index of the
9146         ingress QoS policer of this forwarding-plane queue group on access."
9147    ::= { tFPAccIngQGrpPlcrOvrEntry 1 }
9148
9149tFPAccIngQGrpPlcrOvrRowStatus OBJECT-TYPE
9150    SYNTAX       RowStatus
9151    MAX-ACCESS   read-create
9152    STATUS       current
9153    DESCRIPTION
9154        "The value of tFPAccIngQGrpPlcrOvrRowStatus specifies the Row Status of
9155         the entry.
9156
9157         This tFPAccIngQGrpPlcrOvrRowStatus object allows creation/deletion of
9158         rows in this table."
9159    ::= { tFPAccIngQGrpPlcrOvrEntry 2 }
9160
9161tFPAccIngQGrpPlcrOvrLastChgd OBJECT-TYPE
9162    SYNTAX       TimeStamp
9163    MAX-ACCESS   read-only
9164    STATUS       current
9165    DESCRIPTION
9166        "The value of tFPAccIngQGrpPlcrOvrLastChgd indicates the timestamp of
9167         last change to this row in tFPAccIngQGrpPlcrOvrTable."
9168    ::= { tFPAccIngQGrpPlcrOvrEntry 3 }
9169
9170tFPAccIngQGrpPlcrOvrAdminPIR OBJECT-TYPE
9171    SYNTAX       THPolPIRRateOverride
9172    UNITS        "kbps"
9173    MAX-ACCESS   read-create
9174    STATUS       current
9175    DESCRIPTION
9176        "The value of tFPAccIngQGrpPlcrOvrAdminPIR specifies the administrative
9177         PIR specified by the user."
9178    DEFVAL { -2 }
9179    ::= { tFPAccIngQGrpPlcrOvrEntry 4 }
9180
9181tFPAccIngQGrpPlcrOvrAdminCIR OBJECT-TYPE
9182    SYNTAX       THPolCIRRateOverride
9183    UNITS        "kbps"
9184    MAX-ACCESS   read-create
9185    STATUS       current
9186    DESCRIPTION
9187        "The value of tFPAccIngQGrpPlcrOvrAdminCIR specifies the administrative
9188         CIR specified by the user."
9189    DEFVAL { -2 }
9190    ::= { tFPAccIngQGrpPlcrOvrEntry 5 }
9191
9192tFPAccIngQGrpPlcrOvrStatMode OBJECT-TYPE
9193    SYNTAX       TmnxIngPolicerStatModeOverride
9194    MAX-ACCESS   read-create
9195    STATUS       current
9196    DESCRIPTION
9197        "The value of tFPAccIngQGrpPlcrOvrStatMode specifies the mode of
9198         statistics collected by the policer on this forwarding-plane
9199         QoS ingress queue group."
9200    DEFVAL { noOverride }
9201    ::= { tFPAccIngQGrpPlcrOvrEntry 6 }
9202
9203tFPAccIngQGrpPlcrOvrMBS OBJECT-TYPE
9204    SYNTAX       TPlcrBurstSizeBytesOverride
9205    UNITS        "bytes"
9206    MAX-ACCESS   read-create
9207    STATUS       current
9208    DESCRIPTION
9209        "The value of tFPAccIngQGrpPlcrOvrMBS specifies the maximum amount of
9210         buffer space (in bytes) allowed for the queue by the policer on this
9211         forwarding-plane QoS ingress queue group."
9212    DEFVAL { -2 }
9213    ::= { tFPAccIngQGrpPlcrOvrEntry 7 }
9214
9215tFPAccIngQGrpPlcrOvrCBS OBJECT-TYPE
9216    SYNTAX       TPlcrBurstSizeBytesOverride
9217    UNITS        "bytes"
9218    MAX-ACCESS   read-create
9219    STATUS       current
9220    DESCRIPTION
9221        "The value of tFPAccIngQGrpPlcrOvrCBS specifies the amount of reserved
9222         buffer space (in bytes) set by the policer on this forwarding-plane
9223         QoS ingress queue group."
9224    DEFVAL { -2 }
9225    ::= { tFPAccIngQGrpPlcrOvrEntry 8 }
9226
9227tFPAccIngQGrpPlcrOvrPktOffset OBJECT-TYPE
9228    SYNTAX       TPerPacketOffsetOvr
9229    UNITS        "bytes"
9230    MAX-ACCESS   read-create
9231    STATUS       current
9232    DESCRIPTION
9233        "The value of tFPAccIngQGrpPlcrOvrPktOffset specifies the packet byte
9234         offset for addition of policing information by the policer on this
9235         forwarding-plane QoS ingress queue group."
9236    DEFVAL { -128 }
9237    ::= { tFPAccIngQGrpPlcrOvrEntry 9 }
9238
9239
9240-- ----------------------------------------
9241-- FP Access Ingress QoS Queue Group Arbiter Statistics Table
9242-- ----------------------------------------
9243tFPAccIngQGrpArbitStatTable OBJECT-TYPE
9244    SYNTAX          SEQUENCE OF TFPAccIngQGrpArbitStatEntry
9245    MAX-ACCESS      not-accessible
9246    STATUS          current
9247    DESCRIPTION
9248        "The value of tFPAccIngQGrpArbitStatTable contains forwarding-plane
9249         ingress QoS queue group policer statistics on access side."
9250    ::= { tmnxCardObjs 31 }
9251
9252tFPAccIngQGrpArbitStatEntry OBJECT-TYPE
9253    SYNTAX          TFPAccIngQGrpArbitStatEntry
9254    MAX-ACCESS      not-accessible
9255    STATUS          current
9256    DESCRIPTION
9257        "The value of tFPAccIngQGrpArbitStatEntry defines an entry in the
9258         tFPAccIngQGrpArbitStatTable. It represents statistics about a
9259         specific QoS ingress queue group policer."
9260    INDEX           { tmnxChassisIndex, tmnxCardSlotNum, tmnxFPNum,
9261                      tmnxFPAccIngQGrpName, tmnxFPAccIngQGrpInstanceId,
9262                      tFPAccIngQGrpArbitStatName }
9263    ::= { tFPAccIngQGrpArbitStatTable 1 }
9264
9265TFPAccIngQGrpArbitStatEntry ::=
9266    SEQUENCE {
9267        tFPAccIngQGrpArbitStatName             TNamedItem,
9268        tFPAccIngQGrpArbitStatFwdPkts          Counter64,
9269        tFPAccIngQGrpArbitStatFwdPktsL         Counter32,
9270        tFPAccIngQGrpArbitStatFwdPktsH         Counter32,
9271        tFPAccIngQGrpArbitStatFwdOcts          Counter64,
9272        tFPAccIngQGrpArbitStatFwdOctsL         Counter32,
9273        tFPAccIngQGrpArbitStatFwdOctsH         Counter32
9274    }
9275
9276tFPAccIngQGrpArbitStatName OBJECT-TYPE
9277    SYNTAX          TNamedItem
9278    MAX-ACCESS      not-accessible
9279    STATUS          current
9280    DESCRIPTION
9281        "The value of tFPAccIngQGrpArbitStatName specifies the name of the
9282         ingress QoS arbiter of this forwarding-plane queue group on access."
9283    ::= { tFPAccIngQGrpArbitStatEntry 1 }
9284
9285tFPAccIngQGrpArbitStatFwdPkts OBJECT-TYPE
9286    SYNTAX          Counter64
9287    MAX-ACCESS      read-only
9288    STATUS          current
9289    DESCRIPTION
9290       "The value of tFPAccIngQGrpArbitStatFwdPkts indicates the number of
9291        fowrwarded packets by the ingress queue group arbiter Pchip."
9292    ::= { tFPAccIngQGrpArbitStatEntry 2 }
9293
9294tFPAccIngQGrpArbitStatFwdPktsL OBJECT-TYPE
9295    SYNTAX          Counter32
9296    MAX-ACCESS      read-only
9297    STATUS          current
9298    DESCRIPTION
9299       "The value of tFPAccIngQGrpArbitStatFwdPktsL indicates the lower 32
9300        bits of tFPAccIngQGrpArbitStatFwdPkts."
9301    ::= { tFPAccIngQGrpArbitStatEntry 3 }
9302
9303tFPAccIngQGrpArbitStatFwdPktsH OBJECT-TYPE
9304    SYNTAX          Counter32
9305    MAX-ACCESS      read-only
9306    STATUS          current
9307    DESCRIPTION
9308       "The value of tFPAccIngQGrpArbitStatFwdPktsH indicates the upper 32
9309        bits of tFPAccIngQGrpArbitStatFwdPkts."
9310    ::= { tFPAccIngQGrpArbitStatEntry 4 }
9311
9312tFPAccIngQGrpArbitStatFwdOcts OBJECT-TYPE
9313    SYNTAX          Counter64
9314    MAX-ACCESS      read-only
9315    STATUS          current
9316    DESCRIPTION
9317       "The value of tFPAccIngQGrpArbitStatFwdOcts indicates the number of
9318        fowrwarded octets by the ingress queue group arbiter Pchip."
9319    ::= { tFPAccIngQGrpArbitStatEntry 5 }
9320
9321tFPAccIngQGrpArbitStatFwdOctsL OBJECT-TYPE
9322    SYNTAX          Counter32
9323    MAX-ACCESS      read-only
9324    STATUS          current
9325    DESCRIPTION
9326       "The value of tFPAccIngQGrpArbitStatFwdOctsL indicates the lower 32
9327        bits of tFPAccIngQGrpArbitStatFwdOcts."
9328    ::= { tFPAccIngQGrpArbitStatEntry 6 }
9329
9330tFPAccIngQGrpArbitStatFwdOctsH OBJECT-TYPE
9331    SYNTAX          Counter32
9332    MAX-ACCESS      read-only
9333    STATUS          current
9334    DESCRIPTION
9335       "The value of tFPAccIngQGrpArbitStatFwdOctsH indicates the upper 32
9336        bits of tFPAccIngQGrpArbitStatFwdOcts."
9337    ::= { tFPAccIngQGrpArbitStatEntry 7 }
9338
9339
9340-- ----------------------------------------
9341-- FP Network Ingress QoS Queue Group Arbiter Statistics Table
9342-- ----------------------------------------
9343tFPNetIngQGrpArbitStatTable OBJECT-TYPE
9344    SYNTAX          SEQUENCE OF TFPNetIngQGrpArbitStatEntry
9345    MAX-ACCESS      not-accessible
9346    STATUS          current
9347    DESCRIPTION
9348        "The value of tFPNetIngQGrpArbitStatTable contains forwarding-plane
9349         ingress QoS queue group arbiter statistics on network side."
9350    ::= { tmnxCardObjs 32 }
9351
9352tFPNetIngQGrpArbitStatEntry OBJECT-TYPE
9353    SYNTAX          TFPNetIngQGrpArbitStatEntry
9354    MAX-ACCESS      not-accessible
9355    STATUS          current
9356    DESCRIPTION
9357        "The value of tFPNetIngQGrpArbitStatEntry defines an entry in the
9358         tFPNetIngQGrpArbitStatTable. It represents statistics about a
9359         specific QoS ingress queue group arbiter."
9360    INDEX           { tmnxChassisIndex, tmnxCardSlotNum, tmnxFPNum,
9361                      tmnxFPNetIngQGrpName, tmnxFPNetIngQGrpInstanceId,
9362                      tFPNetIngQGrpArbitStatName }
9363    ::= { tFPNetIngQGrpArbitStatTable 1 }
9364
9365TFPNetIngQGrpArbitStatEntry ::=
9366    SEQUENCE {
9367        tFPNetIngQGrpArbitStatName             TNamedItem,
9368        tFPNetIngQGrpArbitStatFwdPkts          Counter64,
9369        tFPNetIngQGrpArbitStatFwdPktsL         Counter32,
9370        tFPNetIngQGrpArbitStatFwdPktsH         Counter32,
9371        tFPNetIngQGrpArbitStatFwdOcts          Counter64,
9372        tFPNetIngQGrpArbitStatFwdOctsL         Counter32,
9373        tFPNetIngQGrpArbitStatFwdOctsH         Counter32
9374    }
9375
9376tFPNetIngQGrpArbitStatName OBJECT-TYPE
9377    SYNTAX          TNamedItem
9378    MAX-ACCESS      not-accessible
9379    STATUS          current
9380    DESCRIPTION
9381        "The value of tFPNetIngQGrpArbitStatName specifies the name of the
9382         ingress QoS arbiter of this forwarding-plane queue group on network."
9383    ::= { tFPNetIngQGrpArbitStatEntry 1 }
9384
9385tFPNetIngQGrpArbitStatFwdPkts OBJECT-TYPE
9386    SYNTAX          Counter64
9387    MAX-ACCESS      read-only
9388    STATUS          current
9389    DESCRIPTION
9390       "The value of tFPNetIngQGrpArbitStatFwdPkts indicates the number of
9391        fowrwarded packets by the ingress queue group arbiter Pchip."
9392    ::= { tFPNetIngQGrpArbitStatEntry 2 }
9393
9394tFPNetIngQGrpArbitStatFwdPktsL OBJECT-TYPE
9395    SYNTAX          Counter32
9396    MAX-ACCESS      read-only
9397    STATUS          current
9398    DESCRIPTION
9399       "The value of tFPNetIngQGrpArbitStatFwdPktsL indicates the lower 32
9400        bits of tFPNetIngQGrpArbitStatFwdPkts."
9401    ::= { tFPNetIngQGrpArbitStatEntry 3 }
9402
9403tFPNetIngQGrpArbitStatFwdPktsH OBJECT-TYPE
9404    SYNTAX          Counter32
9405    MAX-ACCESS      read-only
9406    STATUS          current
9407    DESCRIPTION
9408       "The value of tFPNetIngQGrpArbitStatFwdPktsH indicates the upper 32
9409        bits of tFPNetIngQGrpArbitStatFwdPkts."
9410    ::= { tFPNetIngQGrpArbitStatEntry 4 }
9411
9412tFPNetIngQGrpArbitStatFwdOcts OBJECT-TYPE
9413    SYNTAX          Counter64
9414    MAX-ACCESS      read-only
9415    STATUS          current
9416    DESCRIPTION
9417       "The value of tFPNetIngQGrpArbitStatFwdOcts indicates the number of
9418        fowrwarded octets by the ingress queue group arbiter Pchip."
9419    ::= { tFPNetIngQGrpArbitStatEntry 5 }
9420
9421tFPNetIngQGrpArbitStatFwdOctsL OBJECT-TYPE
9422    SYNTAX          Counter32
9423    MAX-ACCESS      read-only
9424    STATUS          current
9425    DESCRIPTION
9426       "The value of tFPNetIngQGrpArbitStatFwdOctsL indicates the lower 32
9427        bits of tFPNetIngQGrpArbitStatFwdOcts."
9428    ::= { tFPNetIngQGrpArbitStatEntry 6 }
9429
9430tFPNetIngQGrpArbitStatFwdOctsH OBJECT-TYPE
9431    SYNTAX          Counter32
9432    MAX-ACCESS      read-only
9433    STATUS          current
9434    DESCRIPTION
9435       "The value of tFPNetIngQGrpArbitStatFwdOctsH indicates the upper 32
9436        bits of tFPNetIngQGrpArbitStatFwdOcts."
9437    ::= { tFPNetIngQGrpArbitStatEntry 7 }
9438
9439--
9440--  HQoS Fine Tunnning Vitrual Scheduler Adjustment Table
9441--
9442
9443tmnxVirtualSchedulerAdjTable OBJECT-TYPE
9444    SYNTAX  SEQUENCE OF TmnxVirtualSchedulerAdjEntry
9445    MAX-ACCESS  not-accessible
9446    STATUS      current
9447    DESCRIPTION
9448        "The tmnxVirtualSchedulerAdjTable has an entry to fine tune Quality of
9449         Service (QoS) parameters."
9450    ::= { tmnxCardObjs 33 }
9451
9452tmnxVirtualSchedulerAdjEntry OBJECT-TYPE
9453    SYNTAX     TmnxVirtualSchedulerAdjEntry
9454    MAX-ACCESS not-accessible
9455    STATUS     current
9456    DESCRIPTION
9457        "The tmnxVirtualSchedulerAdjEntry allows fine tune Quality of Service
9458         (QoS) parameters on the corresponding card.
9459
9460         The row exists only if the associated card instance identified by
9461         tmnxCardSlotNum exists in the tmnxCardTable."
9462    AUGMENTS      { tmnxCardEntry }
9463    ::= { tmnxVirtualSchedulerAdjTable 1 }
9464
9465TmnxVirtualSchedulerAdjEntry ::=
9466    SEQUENCE {
9467        tmnxCardRateCalcFastQueue           Unsigned32,
9468        tmnxCardRateCalcSlowQueue           Unsigned32,
9469        tmnxCardSchedRun                    Unsigned32,
9470        tmnxCardTaskScheduling              Unsigned32,
9471        tmnxCardSlowQueueThresh             Integer32
9472    }
9473
9474tmnxCardRateCalcFastQueue OBJECT-TYPE
9475    SYNTAX       Unsigned32 (1..100000)
9476    UNITS        "thousandths of a percent"
9477    MAX-ACCESS   read-write
9478    STATUS       current
9479    DESCRIPTION
9480        "The value of tmnxCardRateCalcFastQueue specifies the percentage by
9481         which fine tuning of Quality of Service (QoS) parameter 'Fast-Queue'
9482         is modified."
9483    DEFVAL { 10000 }
9484    ::= { tmnxVirtualSchedulerAdjEntry 1 }
9485
9486tmnxCardRateCalcSlowQueue OBJECT-TYPE
9487    SYNTAX       Unsigned32 (1..100000)
9488    UNITS        "thousandths of a percent"
9489    MAX-ACCESS   read-write
9490    STATUS       current
9491    DESCRIPTION
9492        "The value of tmnxCardRateCalcSlowQueue specifies the percentage by
9493         which fine tuning of Quality of Service (QoS) parameter 'Slow-Queue'
9494         is modified."
9495    DEFVAL { 10000 }
9496    ::= { tmnxVirtualSchedulerAdjEntry 2 }
9497
9498tmnxCardSchedRun OBJECT-TYPE
9499    SYNTAX       Unsigned32 (1..100000)
9500    UNITS        "thousandths of a percent"
9501    MAX-ACCESS   read-write
9502    STATUS       current
9503    DESCRIPTION
9504        "The value of tmnxCardSchedRun specifies the percentage by
9505         which the minimum amount of time required between the iterations of
9506         bandwidth distribution by an Quality of Service (QoS) virtual
9507         scheduler is modified."
9508    DEFVAL { 10000 }
9509    ::= { tmnxVirtualSchedulerAdjEntry 3 }
9510
9511tmnxCardTaskScheduling OBJECT-TYPE
9512    SYNTAX       Unsigned32 (1..100000)
9513    UNITS        "thousandths of a percent"
9514    MAX-ACCESS   read-write
9515    STATUS       current
9516    DESCRIPTION
9517        "The value of tmnxCardTaskScheduling specifies the percentage change in
9518         virtual scheduling task wake up interval."
9519    DEFVAL { 10000 }
9520    ::= { tmnxVirtualSchedulerAdjEntry 4 }
9521
9522tmnxCardSlowQueueThresh OBJECT-TYPE
9523    SYNTAX       Integer32 (0..1000000)
9524    UNITS        "kbps"
9525    MAX-ACCESS   read-write
9526    STATUS       current
9527    DESCRIPTION
9528        "The value of tmnxCardSlowQueueThresh specifies the rate at which
9529         queues are placed in the 'slow-queue' category."
9530    DEFVAL { 1000 }
9531    ::= { tmnxVirtualSchedulerAdjEntry 5 }
9532
9533--
9534--  Fabric Module Type Definition Table
9535--
9536tmnxFabricTypeTable              OBJECT-TYPE
9537    SYNTAX      SEQUENCE OF TmnxFabricTypeEntry
9538    MAX-ACCESS  not-accessible
9539    STATUS      current
9540    DESCRIPTION
9541        "The fabric type table has an entry for each Alcatel-Lucent SROS series
9542         Fabric card type."
9543    ::= { tmnxCardObjs 26 }
9544
9545tmnxFabricTypeEntry              OBJECT-TYPE
9546    SYNTAX      TmnxFabricTypeEntry
9547    MAX-ACCESS  not-accessible
9548    STATUS      current
9549    DESCRIPTION
9550        "Each row entry represents an Alcatel-Lucent SROS series Fabric card.
9551         Rows in this table are created by the agent at initialization and
9552         cannot be created or destroyed by SNMP Get or Set requests."
9553    INDEX   { tmnxFabricTypeIndex }
9554    ::= { tmnxFabricTypeTable 1 }
9555
9556TmnxFabricTypeEntry              ::= SEQUENCE {
9557    tmnxFabricTypeIndex              TmnxFabricType,
9558    tmnxFabricTypeName               TNamedItemOrEmpty,
9559    tmnxFabricTypeDescription        TItemDescription,
9560    tmnxFabricTypeStatus             TruthValue
9561    }
9562
9563tmnxFabricTypeIndex    OBJECT-TYPE
9564    SYNTAX      TmnxFabricType
9565    MAX-ACCESS  not-accessible
9566    STATUS      current
9567    DESCRIPTION
9568        "The unique index value which identifies this type of Alcatel-Lucent
9569         SROS series Fabric card type."
9570    ::= { tmnxFabricTypeEntry 1 }
9571
9572tmnxFabricTypeName     OBJECT-TYPE
9573    SYNTAX      TNamedItemOrEmpty
9574    MAX-ACCESS  read-only
9575    STATUS      current
9576    DESCRIPTION
9577        "The administrative name that identifies this type of Alcatel-Lucent
9578         SROS series Fabric card.  This name string may be used in CLI
9579         commands to specify a particular fabric card type."
9580    ::= { tmnxFabricTypeEntry 2 }
9581
9582tmnxFabricTypeDescription  OBJECT-TYPE
9583    SYNTAX      TItemDescription
9584    MAX-ACCESS  read-only
9585    STATUS      current
9586    DESCRIPTION
9587        "A detailed description of this Alcatel-Lucent SROS series Fabric card."
9588    ::= { tmnxFabricTypeEntry 3 }
9589
9590tmnxFabricTypeStatus       OBJECT-TYPE
9591    SYNTAX      TruthValue
9592    MAX-ACCESS  read-only
9593    STATUS      current
9594    DESCRIPTION
9595        "When tmnxFabricTypeStatus has a value of 'true' it
9596        indicates that this Fabric is supported in this revision of the
9597        management software.  When it has a value of 'false' there is no
9598        support."
9599    ::= { tmnxFabricTypeEntry 4 }
9600
9601--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
9602 --
9603 --     Notification Definition section
9604 --
9605 --                     Notification Objects
9606 --
9607
9608 tmnxEqNotificationRow  OBJECT-TYPE
9609    SYNTAX       RowPointer
9610    MAX-ACCESS   accessible-for-notify
9611    STATUS       current
9612    DESCRIPTION
9613        "used by tmnx chassis Notifications, the OID
9614        indicates the table and entry."
9615    ::= { tmnxChassisNotificationObjects 1 }
9616
9617 tmnxEqTypeNotificationRow  OBJECT-TYPE
9618    SYNTAX      RowPointer
9619    MAX-ACCESS  accessible-for-notify
9620    STATUS      current
9621    DESCRIPTION
9622        "used by tmnx chassis notifications, the OID indicates the
9623         table and entry with the equipment model type information."
9624    ::= { tmnxChassisNotificationObjects 2 }
9625
9626 tmnxChassisNotifyChassisId  OBJECT-TYPE
9627    SYNTAX      TmnxChassisIndex
9628    MAX-ACCESS  accessible-for-notify
9629    STATUS      current
9630    DESCRIPTION
9631        "Used by tmnx chassis and port Notifications, indicates the chassis
9632         associated with the alarm."
9633    ::= { tmnxChassisNotificationObjects 3 }
9634
9635 tmnxChassisNotifyHwIndex       OBJECT-TYPE
9636    SYNTAX      TmnxHwIndex
9637    MAX-ACCESS  accessible-for-notify
9638    STATUS  current
9639    DESCRIPTION
9640        "Used by tmnx chassis and port Notifications, indicates the entry
9641         in the tmnxHwTable for the hardware component associated with an
9642         alarm."
9643    ::= { tmnxChassisNotificationObjects 4 }
9644
9645tmnxRedSecondaryCPMStatus       OBJECT-TYPE
9646    SYNTAX      INTEGER {
9647                    online (1),
9648                    offline (2),
9649                    fail (3)
9650                }
9651    MAX-ACCESS  accessible-for-notify
9652    STATUS  current
9653    DESCRIPTION
9654        "Used by the tmnxRedSecondaryCPMStatusChange Notification, indicates
9655         the status of the secondary CPM."
9656    ::= { tmnxChassisNotificationObjects 5 }
9657
9658tmnxChassisNotifyOID  OBJECT-TYPE
9659    SYNTAX       OBJECT IDENTIFIER
9660    MAX-ACCESS   accessible-for-notify
9661    STATUS       current
9662    DESCRIPTION
9663        "Used by the tmnxChassisNotificationClear trap, the OID
9664         identifies the trap which is getting cleared."
9665    ::= { tmnxChassisNotificationObjects 6 }
9666
9667tmnxSyncIfTimingNotifyAlarm  OBJECT-TYPE
9668    SYNTAX      INTEGER {
9669                    notUsed (0),
9670                    los (1),
9671                    oof (2),
9672                    oopir (3)
9673                }
9674    MAX-ACCESS   accessible-for-notify
9675    STATUS       current
9676    DESCRIPTION
9677        "Used by tmnx Synchronous interface timing notifications, the value of
9678         tmnxSyncIfTimingNotifyAlarm indicates the reason a timing reference
9679         alarm has been raised."
9680    ::= { tmnxChassisNotificationObjects 7 }
9681
9682tmnxChassisNotifyMismatchedVer OBJECT-TYPE
9683    SYNTAX      DisplayString
9684    MAX-ACCESS  accessible-for-notify
9685    STATUS      current
9686    DESCRIPTION
9687        "Used by tmnxPeSoftwareVersionMismatch, the value of
9688         tmnxChassisNotifyMismatchedVer indicates the software version of the
9689         mismatched CPM/IOM card."
9690    ::= { tmnxChassisNotificationObjects 8 }
9691
9692tmnxChassisNotifySoftwareLocation OBJECT-TYPE
9693    SYNTAX      DisplayString
9694    MAX-ACCESS  accessible-for-notify
9695    STATUS      current
9696    DESCRIPTION
9697        "Used by tmnxPeSoftwareLoadFailed, the value of
9698         tmnxChassisNotifySoftwareLocation contains the location of the
9699         software."
9700    ::= { tmnxChassisNotificationObjects 9 }
9701
9702tmnxChassisNotifyCardFailureReason OBJECT-TYPE
9703    SYNTAX      DisplayString
9704    MAX-ACCESS  accessible-for-notify
9705    STATUS      current
9706    DESCRIPTION
9707        "Used by tmnxEqCardFailure, the value of
9708         tmnxChassisNotifyCardFailureReason contains the
9709         reason for card failure."
9710    ::= { tmnxChassisNotificationObjects 10 }
9711
9712tmnxChassisNotifyCardName   OBJECT-TYPE
9713    SYNTAX      DisplayString (SIZE(1..32))
9714    MAX-ACCESS  accessible-for-notify
9715    STATUS      current
9716    DESCRIPTION
9717        "Used by tmnxEqCardInserted and tmnxEqCardRemoved, the value
9718         of tmnxChassisNotifyCardName specifies the name of the affected
9719         card."
9720    ::= { tmnxChassisNotificationObjects 11 }
9721
9722tmnxChassisNotifyCardSyncFile   OBJECT-TYPE
9723    SYNTAX      DisplayString
9724    MAX-ACCESS  accessible-for-notify
9725    STATUS      current
9726    DESCRIPTION
9727        "Used by tmnxCpmCardSyncFileNotPresent, the value of
9728         tmnxChassisNotifyCardSyncFile specifies the name of
9729         the affected file."
9730    ::= { tmnxChassisNotificationObjects 12 }
9731
9732tmnxCardComplexNumber            OBJECT-TYPE
9733    SYNTAX      Unsigned32
9734    MAX-ACCESS  accessible-for-notify
9735    STATUS      current
9736    DESCRIPTION
9737        "Used by tmnxEqCardPChipError, the value of tmnxCardComplexNumber
9738         specifies the number of the affected Complex."
9739    ::= { tmnxChassisNotificationObjects 13 }
9740
9741tmnxCardFwdDirection             OBJECT-TYPE
9742    SYNTAX      INTEGER {
9743                       ingress (1),
9744                       egress  (2)
9745                }
9746    MAX-ACCESS  accessible-for-notify
9747    STATUS      current
9748    DESCRIPTION
9749        "Used by tmnxEqCardPChipError, the value of tmnxCardFwdDirection
9750         specifies the direction of the affected Complex."
9751    ::= { tmnxChassisNotificationObjects 14 }
9752
9753tmnxCardSoftResetState           OBJECT-TYPE
9754    SYNTAX     INTEGER {
9755                   initiated (1),
9756                   aborted   (2),
9757                   complete  (3)
9758               }
9759   MAX-ACCESS  accessible-for-notify
9760   STATUS      current
9761   DESCRIPTION
9762       "Used by tmnxEqCardSoftResetAlarm, the value of tmnxCardSoftResetState
9763        specifies the reset state of the IOM card."
9764   ::= { tmnxChassisNotificationObjects 15 }
9765
9766tmnxMdaNotifyType                OBJECT-TYPE
9767    SYNTAX      TmnxMdaType
9768    MAX-ACCESS  accessible-for-notify
9769    STATUS      current
9770    DESCRIPTION
9771        "Used by equipment alarms where the type of MDA isn't supported with
9772         the current configuration."
9773    ::= { tmnxChassisNotificationObjects 16 }
9774
9775tmnxCardSrcSlotBitmap            OBJECT-TYPE
9776    SYNTAX      TmnxCardSlotBitMap
9777    MAX-ACCESS  accessible-for-notify
9778    STATUS      current
9779    DESCRIPTION
9780        "Used by tmnxEqCardPChipError, the value of tmnxCardSrcSlotBitmap
9781         specifies the source slots of the affected Complex."
9782    ::= { tmnxChassisNotificationObjects 17 }
9783
9784--
9785--              TIMETRA-CHASSIS-MIB Notifications
9786--
9787
9788--
9789--              Hardware Configuration Change Alarm
9790--
9791 tmnxHwConfigChange NOTIFICATION-TYPE
9792    OBJECTS {
9793        tmnxChassisNotifyHwIndex,
9794        tmnxHwID,
9795        tmnxHwClass
9796    }
9797    STATUS  obsolete
9798    DESCRIPTION
9799        "A tmnxHwConfigChange notification is generated when the value of
9800         tmnxHwLastChange is updated.  It can be used by the NMS to trigger
9801         maintenance polls of the hardware configuration information.
9802
9803         Only one tmnxHwConfigChange notification event will be generated
9804         in a 5 second throttling time period.  A notification event is
9805         the transmission of a single trap to a list of notification
9806         destinations configured in the SNMP-TARGET-MIB.
9807
9808         If additional hardware configuration change occurs within the
9809         throttling period, the notification events for these changes are
9810         suppressed until the throttling period expires.  At the end of
9811         the throttling period, one notification event is generated if
9812         any addition configuration changes occurred within the just
9813         completed throttling period and another throttling period is
9814         started.
9815
9816         The NMS should periodically check the value of tmnxHwConfigChange
9817         to detect any missed tmnxHwConfigChange traps.
9818
9819         This notification was made obsolete in the 2.1 release.
9820
9821         The tmnxHwConfigChange notification has been replaced
9822         with the generic change notifications from the
9823         TIMETRA-SYSTEM-MIB: tmnxConfigModify, tmnxConfigCreate,
9824         tmnxConfigDelete, tmnxStateChange."
9825    ::= { tmnxChassisNotification 1 }
9826
9827
9828--
9829--  Environmental Alarms
9830--
9831 tmnxEnvTempTooHigh NOTIFICATION-TYPE
9832    OBJECTS {
9833        tmnxChassisNotifyHwIndex,
9834        tmnxHwID,
9835        tmnxHwClass,
9836        tmnxHwTemperature,
9837        tmnxHwTempThreshold
9838    }
9839    STATUS  current
9840    DESCRIPTION
9841        "Generated when the temperature sensor reading on an equipment
9842         object is greater than its configured threshold."
9843    ::= { tmnxChassisNotification 2 }
9844
9845--
9846--  Equipment Alarms
9847--
9848
9849 tmnxEqPowerSupplyFailure   NOTIFICATION-TYPE
9850    OBJECTS {
9851        tmnxChassisNotifyHwIndex,
9852        tmnxHwID,
9853        tmnxHwClass,
9854        tmnxChassisPowerSupplyACStatus,
9855        tmnxChassisPowerSupplyDCStatus,
9856        tmnxChassisPowerSupplyTempStatus,
9857        tmnxChassisPowerSupplyTempThreshold,
9858        tmnxChassisPowerSupply1Status,
9859        tmnxChassisPowerSupply2Status,
9860        tmnxChassisPowerSupplyInputStatus,
9861        tmnxChassisPowerSupplyOutputStatus
9862    }
9863    STATUS  current
9864    DESCRIPTION
9865        "Generated when one of the chassis's power supplies fails."
9866    ::= { tmnxChassisNotification 3 }
9867
9868 tmnxEqPowerSupplyInserted   NOTIFICATION-TYPE
9869    OBJECTS {
9870        tmnxChassisNotifyHwIndex,
9871        tmnxHwID,
9872        tmnxHwClass
9873    }
9874    STATUS  current
9875    DESCRIPTION
9876        "Generated when one of the chassis's power supplies is inserted."
9877    ::= { tmnxChassisNotification 4 }
9878
9879 tmnxEqPowerSupplyRemoved   NOTIFICATION-TYPE
9880    OBJECTS {
9881        tmnxChassisNotifyHwIndex,
9882        tmnxHwID,
9883        tmnxHwClass
9884    }
9885    STATUS  current
9886    DESCRIPTION
9887        "Generated when one of the chassis's power supplies is removed."
9888    ::= { tmnxChassisNotification 5 }
9889
9890 tmnxEqFanFailure   NOTIFICATION-TYPE
9891    OBJECTS {
9892        tmnxChassisNotifyHwIndex,
9893        tmnxHwID,
9894        tmnxHwClass,
9895        tmnxChassisFanOperStatus,
9896        tmnxChassisFanSpeed
9897    }
9898    STATUS  current
9899    DESCRIPTION
9900        "Generated when one of the fans in a fan tray has failed."
9901    ::= { tmnxChassisNotification 6 }
9902
9903 tmnxEqCardFailure  NOTIFICATION-TYPE
9904    OBJECTS {
9905        tmnxChassisNotifyHwIndex,
9906        tmnxHwID,
9907        tmnxHwClass,
9908        tmnxHwOperState,
9909        tmnxChassisNotifyCardFailureReason
9910    }
9911    STATUS  current
9912    DESCRIPTION
9913        "Generated when one of the cards in a chassis has failed.  The card
9914         type may be IOM, Fabric, MDA, MCM, CCM, CPM module, compact flash
9915         module, etc. tmnxChassisNotifyCardFailureReason contains the reason
9916         for card failure."
9917    ::= { tmnxChassisNotification 7 }
9918
9919 tmnxEqCardInserted NOTIFICATION-TYPE
9920    OBJECTS {
9921        tmnxChassisNotifyHwIndex,
9922        tmnxHwID,
9923        tmnxHwClass,
9924        tmnxChassisNotifyCardName
9925    }
9926    STATUS  current
9927    DESCRIPTION
9928        "Generated when a card is inserted into the chassis.  The card type
9929         may be IOM, Fabric, MDA, MCM, CCM CPM module, compact flash module,
9930         etc."
9931    ::= { tmnxChassisNotification 8 }
9932
9933 tmnxEqCardRemoved NOTIFICATION-TYPE
9934    OBJECTS {
9935        tmnxChassisNotifyHwIndex,
9936        tmnxHwID,
9937        tmnxHwClass,
9938        tmnxChassisNotifyCardName
9939    }
9940    STATUS  current
9941    DESCRIPTION
9942        "Generated when a card is removed from the chassis.  The card type
9943         may be IOM, Fabric, MDA, MCM, CCM, CPM module, compact flash module,
9944         etc."
9945    ::= { tmnxChassisNotification 9 }
9946
9947 tmnxEqWrongCard    NOTIFICATION-TYPE
9948    OBJECTS {
9949        tmnxChassisNotifyHwIndex,
9950        tmnxHwID,
9951        tmnxHwClass
9952    }
9953    STATUS  current
9954    DESCRIPTION
9955        "Generated when the wrong type of card is inserted into a slot of
9956         the chassis.  Even though a card may be physically supported by
9957         the slot, it may have been administratively configured to allow
9958         only certain card types in a particular slot location.  The card
9959         type may be IOM, Fabric, MDA, MCM, CPM module, etc."
9960    ::= { tmnxChassisNotification 10 }
9961
9962 tmnxEqCpuFailure   NOTIFICATION-TYPE
9963    OBJECTS {
9964        tmnxChassisNotifyHwIndex,
9965        tmnxHwID,
9966        tmnxHwClass
9967    }
9968    STATUS  obsolete
9969    DESCRIPTION
9970        "Generated when a failure is detected for a CPU on an IOM card or
9971         CPM module.
9972
9973         This notification was made obsolete in the 2.1 release.
9974
9975         A cpu failure on a CPM card is detected by the hardware
9976         bootup and is indicated by the boot diagnostic display.
9977         If there is no working redundant CPM card, the system
9978         does not come up.
9979
9980         A failure of an IOM card or standby redundant CPM card
9981         causes the tmnxEqCardFailure notification to be sent."
9982    ::= { tmnxChassisNotification 11 }
9983
9984 tmnxEqMemoryFailure    NOTIFICATION-TYPE
9985    OBJECTS {
9986        tmnxChassisNotifyHwIndex,
9987        tmnxHwID,
9988        tmnxHwClass
9989    }
9990    STATUS  obsolete
9991    DESCRIPTION
9992        "Generated when a memory module failure is detected for an IOM card or
9993         CPM module.
9994
9995         This notification was made obsolete in the 2.1 release.
9996
9997         A failure of the memory device is detected by the
9998         hardware bootup and is indicated by the boot diagnostic
9999         display.  If there is no working redundant CPM card,
10000         the system does not come up.
10001
10002         A failure of the memory device during run-time causes
10003         the system to fail and the 'admin tech-support'
10004         information to be saved.
10005
10006         A failure of an IOM card or standby redundant CPM card
10007         causes the tmnxEqCardFailure notification to be sent."
10008    ::= { tmnxChassisNotification 12 }
10009
10010 tmnxEqBackdoorBusFailure   NOTIFICATION-TYPE
10011    OBJECTS {
10012        tmnxChassisNotifyChassisId
10013    }
10014    STATUS obsolete
10015    DESCRIPTION
10016        "Generated when the backdoor bus has failed.
10017
10018         This notification was made obsolete in the 2.1 release."
10019    ::= { tmnxChassisNotification 13 }
10020
10021--
10022--  Processing Error Alarms
10023--
10024
10025 tmnxPeSoftwareError    NOTIFICATION-TYPE
10026    OBJECTS {
10027        tmnxChassisNotifyHwIndex,
10028        tmnxHwID,
10029        tmnxHwClass
10030    }
10031    STATUS  obsolete
10032    DESCRIPTION
10033        "Generated when a software error has been detected.
10034
10035         This notification was made obsolete in the 2.1 release.
10036
10037         Many of the other notifications more specifically
10038         indicate detection of some type of software error.
10039
10040         The 'admin tech-support' information helps developers
10041         diagnose a failure of the software in the field."
10042    ::= { tmnxChassisNotification 14 }
10043
10044 tmnxPeSoftwareAbnormalHalt     NOTIFICATION-TYPE
10045    OBJECTS {
10046        tmnxChassisNotifyHwIndex,
10047        tmnxHwID,
10048        tmnxHwClass
10049    }
10050    STATUS  obsolete
10051    DESCRIPTION
10052        "Generated when the software has abnormally terminated.
10053
10054        This notification was made obsolete in the 2.1 release.
10055
10056         Many of the other notifications more specifically
10057         indicate detection of some type of software error.
10058
10059         The 'admin tech-support' information helps developers
10060         diagnose a failure of the software in the field."
10061    ::= { tmnxChassisNotification 15 }
10062
10063 tmnxPeSoftwareVersionMismatch  NOTIFICATION-TYPE
10064    OBJECTS {
10065        tmnxChassisNotifyHwIndex,
10066        tmnxHwID,
10067        tmnxHwClass,
10068        tmnxChassisNotifyMismatchedVer,
10069        tmnxHwSoftwareCodeVersion
10070    }
10071    STATUS  current
10072    DESCRIPTION
10073        "Generated when there is a mismatch between software versions of the
10074         active CPM and standby CPM or the CPM and IOM.
10075         tmnxChassisNotifyHwIndex identifies the mismatched CPM/IOM card and
10076         tmnxChassisNotifyMismatchedVer will contain the version of the
10077         mismatched card. The tmnxHwSoftwareCodeVersion object will contain
10078         the expected version."
10079    ::= { tmnxChassisNotification 16 }
10080
10081 tmnxPeOutOfMemory  NOTIFICATION-TYPE
10082    OBJECTS {
10083        tmnxChassisNotifyHwIndex,
10084        tmnxHwID,
10085        tmnxHwClass
10086    }
10087    STATUS  obsolete
10088    DESCRIPTION
10089        "Generated when there is an out of memory error detected.
10090
10091         This notification was made obsolete in the 2.1 release.
10092
10093         The tmnxPeOutOfMemory notification has been replaced
10094         with the module specific notification from the
10095         TIMETRA-SYSTEM-MIB: tmnxModuleMallocFailed."
10096    ::= { tmnxChassisNotification 17 }
10097
10098 tmnxPeConfigurationError   NOTIFICATION-TYPE
10099    OBJECTS {
10100        tmnxChassisNotifyHwIndex,
10101        tmnxHwID,
10102        tmnxHwClass
10103    }
10104    STATUS  obsolete
10105    DESCRIPTION
10106        "Generated when a configuration error has been detected.
10107
10108         This notification was made obsolete in the 2.1 release.
10109
10110         Many other notifications more specifically indicate
10111         detection of a configuration error.  In most cases the
10112         SNMP SET request that tries to make an invalid
10113         configuration results in an error response.
10114
10115         In some cases the configuration parameters are valid
10116         and the SNMP SET request succeeds but the system cannot
10117         successfully apply the new parameters.  The affected
10118         object may then put into an operational 'down' state.
10119         A state change notification such as tmnxStateChange or
10120         a more specific notification is sent to alert about the
10121         problem.
10122
10123         For example, an attempt to create an event log with a
10124         file-type destination when the specified cflash media is
10125         full or not present results in TIMETRA-LOG-MIB
10126         notifications tmnxLogSpaceContention, tmnxLogAdminLocFailed,
10127         or tmnxLogBackupLocFailed."
10128    ::= { tmnxChassisNotification 18 }
10129
10130 tmnxPeStorageProblem   NOTIFICATION-TYPE
10131    OBJECTS {
10132        tmnxChassisNotifyHwIndex,
10133        tmnxHwID,
10134        tmnxHwClass
10135    }
10136    STATUS  obsolete
10137    DESCRIPTION
10138        "Generated when there is a storage capacity problem.
10139
10140         This notification was made obsolete in the 2.1 release.
10141
10142         The only 'storage' devices on the SR7750 are the cflash
10143         drives.  Cflash write errors cause a tmnxEqFlashDataLoss
10144         notification to be sent.  The tmnxEqFlashDiskFull
10145         notification is sent when the driver detects that the
10146         cflash device is full."
10147    ::= { tmnxChassisNotification 19 }
10148
10149 tmnxPeCpuCyclesExceeded    NOTIFICATION-TYPE
10150    OBJECTS {
10151        tmnxChassisNotifyHwIndex,
10152        tmnxHwID,
10153        tmnxHwClass
10154    }
10155    STATUS  obsolete
10156    DESCRIPTION
10157        "Generated when the CPU cycle usage limit has been exceeded.
10158
10159         This notification was made obsolete in the 2.1 release.
10160
10161         It does not apply. The SR7750 software architecture does
10162         not restrict CPU cycles used by a specific code module."
10163    ::= { tmnxChassisNotification 20 }
10164
10165--
10166--  Redundancy notifications
10167--
10168
10169tmnxRedPrimaryCPMFail   NOTIFICATION-TYPE
10170    OBJECTS {
10171        tmnxChassisNotifyHwIndex,
10172        tmnxHwID,
10173        tmnxHwClass
10174    }
10175    STATUS current
10176    DESCRIPTION
10177        "Generated when the primary CPM fails."
10178    ::= { tmnxChassisNotification 21 }
10179
10180tmnxRedSecondaryCPMStatusChange   NOTIFICATION-TYPE
10181    OBJECTS {
10182        tmnxChassisNotifyHwIndex,
10183        tmnxHwID,
10184        tmnxHwClass,
10185        tmnxRedSecondaryCPMStatus
10186    }
10187    STATUS obsolete
10188    DESCRIPTION
10189        "Generated when there is a change in the secondary CPM status.
10190
10191         This notification was made obsolete in the 2.1 release.
10192
10193         There is no way to administratively enable or disable
10194         CPM cards so there is no need for a status change event
10195         for administrative state changes.
10196
10197         Operational changes detected about the standby CPM
10198         card are indicated by more specific notifications such
10199         as tmnxEqCardFailure, tmnxEqCardRemoved, tmnxEqCardInserted
10200         TIMETRA-SYSTEM-MIB::ssiRedStandbyReady,
10201         TIMETRA-SYSTEM-MIB::ssiRedStandbySyncLost, and
10202         TIMETRA-SYSTEM-MIB::ssiRedStandbySyncLost."
10203    ::= { tmnxChassisNotification 22 }
10204
10205tmnxRedRestoreSuccess   NOTIFICATION-TYPE
10206    OBJECTS {
10207        tmnxChassisNotifyHwIndex,
10208        tmnxHwID,
10209        tmnxHwClass
10210    }
10211    STATUS obsolete
10212    DESCRIPTION
10213        "Generated when the secondary CPM successfully restores
10214         the config and state.
10215
10216         This notification was made obsolete in the 2.1 release.
10217
10218         It does not apply. This event was originally created
10219         for an early redundancy mechanism that was never
10220         released."
10221    ::= { tmnxChassisNotification 23 }
10222
10223tmnxRedRestoreFail   NOTIFICATION-TYPE
10224    OBJECTS {
10225        tmnxChassisNotifyHwIndex,
10226        tmnxHwID,
10227        tmnxHwClass
10228    }
10229    STATUS obsolete
10230    DESCRIPTION
10231        "Generated when the secondary CPM fails to
10232         restore the config and state.
10233
10234         This notification was made obsolete in the 2.1 release.
10235
10236         It does not apply. This event was originally created
10237         for an early redundancy mechanism that was never
10238         released."
10239    ::= { tmnxChassisNotification 24 }
10240
10241--
10242--  Chassis Clear Alarm
10243--
10244
10245tmnxChassisNotificationClear   NOTIFICATION-TYPE
10246    OBJECTS {
10247        tmnxChassisNotifyHwIndex,
10248        tmnxHwID,
10249        tmnxHwClass,
10250        tmnxChassisNotifyOID
10251    }
10252    STATUS current
10253    DESCRIPTION
10254        "A trap indicating the clear of a chassis notification
10255         identified by tmnxChassisNotifyOID."
10256    ::= { tmnxChassisNotification 25 }
10257
10258--
10259-- Synchronous timing alarms
10260--
10261
10262tmnxEqSyncIfTimingHoldover   NOTIFICATION-TYPE
10263    OBJECTS {
10264        tmnxChassisNotifyHwIndex,
10265        tmnxHwID,
10266        tmnxHwClass
10267    }
10268    STATUS current
10269    DESCRIPTION
10270        "Generated when the synchronous equipment timing subsystem
10271         transitions into a holdover state.
10272         This notification will have the same indices as those of
10273         the tmnxCpmCardTable."
10274    ::= { tmnxChassisNotification 26 }
10275
10276tmnxEqSyncIfTimingHoldoverClear   NOTIFICATION-TYPE
10277    OBJECTS {
10278        tmnxChassisNotifyHwIndex,
10279        tmnxHwID,
10280        tmnxHwClass
10281    }
10282    STATUS current
10283    DESCRIPTION
10284        "Generated when the synchronous equipment timing subsystem
10285         transitions out of the holdover state.
10286         This notification will have the same indices as those of
10287         the tmnxCpmCardTable."
10288    ::= { tmnxChassisNotification 27 }
10289
10290tmnxEqSyncIfTimingRef1Alarm   NOTIFICATION-TYPE
10291    OBJECTS {
10292        tmnxChassisNotifyHwIndex,
10293        tmnxHwID,
10294        tmnxHwClass,
10295        tmnxSyncIfTimingNotifyAlarm
10296    }
10297    STATUS current
10298    DESCRIPTION
10299        "Generated when an alarm condition on the first timing
10300         reference is detected.
10301         This notification will have the same indices as those of
10302         the tmnxCpmCardTable."
10303    ::= { tmnxChassisNotification 28 }
10304
10305tmnxEqSyncIfTimingRef1AlarmClear   NOTIFICATION-TYPE
10306    OBJECTS {
10307        tmnxChassisNotifyHwIndex,
10308        tmnxHwID,
10309        tmnxHwClass,
10310        tmnxSyncIfTimingNotifyAlarm
10311    }
10312    STATUS current
10313    DESCRIPTION
10314        "Generated when an alarm condition on the first timing
10315         reference is cleared.
10316         This notification will have the same indices as those of
10317         the tmnxCpmCardTable."
10318    ::= { tmnxChassisNotification 29 }
10319
10320tmnxEqSyncIfTimingRef2Alarm   NOTIFICATION-TYPE
10321    OBJECTS {
10322        tmnxChassisNotifyHwIndex,
10323        tmnxHwID,
10324        tmnxHwClass,
10325        tmnxSyncIfTimingNotifyAlarm
10326    }
10327    STATUS current
10328    DESCRIPTION
10329        "Generated when an alarm condition on the second timing
10330         reference is detected.
10331         This notification will have the same indices as those of
10332         the tmnxCpmCardTable."
10333    ::= { tmnxChassisNotification 30 }
10334
10335tmnxEqSyncIfTimingRef2AlarmClear   NOTIFICATION-TYPE
10336    OBJECTS {
10337        tmnxChassisNotifyHwIndex,
10338        tmnxHwID,
10339        tmnxHwClass,
10340        tmnxSyncIfTimingNotifyAlarm
10341    }
10342    STATUS current
10343    DESCRIPTION
10344        "Generated when an alarm condition on the second timing
10345         reference is cleared.
10346         This notification will have the same indices as those of
10347         the tmnxCpmCardTable."
10348    ::= { tmnxChassisNotification 31 }
10349
10350tmnxEqFlashDataLoss   NOTIFICATION-TYPE
10351    OBJECTS {
10352        tmnxChassisNotifyHwIndex,
10353        tmnxHwID,
10354        tmnxHwClass,
10355        tmnxHwOperState
10356    }
10357    STATUS current
10358    DESCRIPTION
10359        "tmnxEqFlashDataLoss is generated when there was an error
10360         while data was getting written on to the compact flash. This
10361         notification indicates a probable data loss."
10362    ::= { tmnxChassisNotification 32 }
10363
10364tmnxEqFlashDiskFull   NOTIFICATION-TYPE
10365    OBJECTS {
10366        tmnxChassisNotifyHwIndex,
10367        tmnxHwID,
10368        tmnxHwClass,
10369        tmnxHwOperState
10370    }
10371    STATUS current
10372    DESCRIPTION
10373        "tmnxEqFlashDiskFull is generated when there is no space
10374         left on the compact flash. No more data can be written to it."
10375    ::= { tmnxChassisNotification 33 }
10376
10377tmnxPeSoftwareLoadFailed   NOTIFICATION-TYPE
10378    OBJECTS {
10379        tmnxChassisNotifyHwIndex,
10380        tmnxHwID,
10381        tmnxHwClass,
10382        tmnxChassisNotifySoftwareLocation
10383    }
10384    STATUS current
10385    DESCRIPTION
10386        "Generated when the CPM fails to load the software from a specified
10387         location.
10388         tmnxChassisNotifyHwIndex identifies the card for which the software
10389         load failed and tmnxChassisNotifySoftwareLocation contains the
10390         location from where the software load was attempted."
10391    ::= { tmnxChassisNotification 34 }
10392
10393 tmnxPeBootloaderVersionMismatch  NOTIFICATION-TYPE
10394    OBJECTS {
10395        tmnxChassisNotifyHwIndex,
10396        tmnxHwID,
10397        tmnxHwClass,
10398        tmnxChassisNotifyMismatchedVer,
10399        tmnxHwSoftwareCodeVersion
10400    }
10401    STATUS  current
10402    DESCRIPTION
10403        "Generated when there is a mismatch between the CPM and boot loader
10404         versions. tmnxChassisNotifyHwIndex identifies the CPM card.
10405         tmnxChassisNotifyMismatchedVer contains the mismatched version of
10406         bootloader and tmnxHwSoftwareCodeVersion contains the
10407         expected version of the bootloader."
10408    ::= { tmnxChassisNotification 35 }
10409
10410 tmnxPeBootromVersionMismatch  NOTIFICATION-TYPE
10411    OBJECTS {
10412        tmnxChassisNotifyHwIndex,
10413        tmnxHwID,
10414        tmnxHwClass,
10415        tmnxChassisNotifyMismatchedVer,
10416        tmnxHwSoftwareCodeVersion
10417    }
10418    STATUS  current
10419    DESCRIPTION
10420        "Generated when there is a mismatch between the boot rom versions.
10421         tmnxChassisNotifyHwIndex identifies the IOM card.
10422         tmnxChassisNotifyMismatchedVer contains the mismatched version of
10423         bootrom and tmnxHwSoftwareCodeVersion contains the expected version
10424         of the bootrom."
10425    ::= { tmnxChassisNotification 36 }
10426
10427 tmnxPeFPGAVersionMismatch  NOTIFICATION-TYPE
10428    OBJECTS {
10429        tmnxChassisNotifyHwIndex,
10430        tmnxHwID,
10431        tmnxHwClass,
10432        tmnxChassisNotifyMismatchedVer,
10433        tmnxHwSoftwareCodeVersion
10434    }
10435    STATUS  current
10436    DESCRIPTION
10437        "Generated when there is a mismatch between the FPGA versions.
10438         tmnxChassisNotifyHwIndex identifies the IOM card.
10439         tmnxChassisNotifyMismatchedVer contains the mismatched version of
10440         FPGA and tmnxHwSoftwareCodeVersion contains the expected version
10441         of the FPGA."
10442    ::= { tmnxChassisNotification 37 }
10443
10444tmnxEqSyncIfTimingBITSAlarm   NOTIFICATION-TYPE
10445    OBJECTS {
10446        tmnxChassisNotifyHwIndex,
10447        tmnxHwID,
10448        tmnxHwClass,
10449        tmnxSyncIfTimingNotifyAlarm
10450    }
10451    STATUS current
10452    DESCRIPTION
10453        "Generated when an alarm condition on the BITS timing
10454         reference is detected.
10455         This notification will have the same indices as those of
10456         the tmnxCpmCardTable."
10457    ::= { tmnxChassisNotification 38 }
10458
10459tmnxEqSyncIfTimingBITSAlarmClear   NOTIFICATION-TYPE
10460    OBJECTS {
10461        tmnxChassisNotifyHwIndex,
10462        tmnxHwID,
10463        tmnxHwClass,
10464        tmnxSyncIfTimingNotifyAlarm
10465    }
10466    STATUS current
10467    DESCRIPTION
10468        "Generated when an alarm condition on the BITS timing
10469         reference is cleared.
10470         This notification will have the same indices as those of
10471         the tmnxCpmCardTable."
10472    ::= { tmnxChassisNotification 39 }
10473
10474tmnxEqCardFirmwareUpgraded NOTIFICATION-TYPE
10475    OBJECTS {
10476        tmnxChassisNotifyHwIndex,
10477        tmnxHwID,
10478        tmnxHwClass
10479    }
10480    STATUS  current
10481    DESCRIPTION
10482        "Generated when a card is hot-inserted into the chassis and its
10483         firmware is automatically upgraded.  The card type may be IOM or
10484         CPM module."
10485    ::= { tmnxChassisNotification 40 }
10486
10487tmnxChassisUpgradeInProgress  NOTIFICATION-TYPE
10488    OBJECTS {
10489        tmnxChassisNotifyHwIndex,
10490        tmnxHwID,
10491        tmnxHwClass
10492    }
10493    STATUS  current
10494    DESCRIPTION
10495        "The tmnxChassisUpgradeInProgress notification is generated only
10496         after a CPM switchover occurs and the new active CPM is running new
10497         software, while the IOMs are still running old software. This is the
10498         start of the upgrade process. The tmnxChassisUpgradeInProgress
10499         notification will continue to be generated every 30 minutes while at
10500         least one IOM is still running older software."
10501    ::= { tmnxChassisNotification 41 }
10502
10503tmnxChassisUpgradeComplete  NOTIFICATION-TYPE
10504    OBJECTS {
10505        tmnxChassisNotifyHwIndex,
10506        tmnxHwID,
10507        tmnxHwClass
10508    }
10509    STATUS  current
10510    DESCRIPTION
10511        "The tmnxChassisUpgradeComplete notification is generated to
10512         indicate that all the IOMs are running matching software version in
10513         reference to the active CPM software version changed as part of the
10514         upgrade process."
10515    ::= { tmnxChassisNotification 42 }
10516
10517tmnxChassisHiBwMcastAlarm   NOTIFICATION-TYPE
10518    OBJECTS {
10519        tmnxChassisNotifyHwIndex,
10520        tmnxHwID,
10521        tmnxHwClass
10522    }
10523    STATUS  current
10524    DESCRIPTION
10525        "The tmnxChassisHiBwMcastAlarm notification is generated when a plane
10526         is  shared by more than one high bandwidth multicast tap."
10527    ::= { tmnxChassisNotification 43 }
10528
10529tmnxEqMdaCfgNotCompatible    NOTIFICATION-TYPE
10530    OBJECTS {
10531        tmnxChassisNotifyHwIndex,
10532        tmnxHwID,
10533        tmnxHwClass,
10534        tmnxMdaNotifyType
10535    }
10536    STATUS  current
10537    DESCRIPTION
10538        "Generated when a supported MDA is inserted into a slot of an
10539         IOM, the MDA is compatible with the currently provisioned
10540         MDA, but the current configuration on the MDA's ports is not
10541         compatible with the inserted MDA.
10542
10543         [EFFECT] Though services can still be created, if the tmnxMdaNotifyType
10544         is the same as the tmnxMDAEquippedType then the MDA will fail to
10545         operate as configured and will be in a failed state.
10546
10547         [RECOVERY] Change the configuration to reflect the capabilities of the
10548         MDA port, or switch out/re-provision the MDA for one that is
10549         compatible."
10550    ::= { tmnxChassisNotification 44 }
10551
10552tmnxCpmCardSyncFileNotPresent    NOTIFICATION-TYPE
10553    OBJECTS {
10554        tmnxChassisNotifyHwIndex,
10555        tmnxHwID,
10556        tmnxHwClass,
10557        tmnxChassisNotifyCardSyncFile
10558    }
10559    STATUS  current
10560    DESCRIPTION
10561        "The tmnxCpmCardSyncFileNotPresent notification is generated when
10562         the redundancy file synchronization failed to locate an optional
10563         file."
10564    ::= { tmnxChassisNotification 45 }
10565
10566tmnxEqMdaXplError        NOTIFICATION-TYPE
10567    OBJECTS {
10568        tmnxMDAXplFailedCount
10569    }
10570    STATUS  current
10571    DESCRIPTION
10572        "The tmnxEqMdaXplError notification is generated when an MDA
10573         exhibits persistent XPL Errors."
10574    ::= { tmnxChassisNotification 46 }
10575
10576tmnxEqCardPChipError             NOTIFICATION-TYPE
10577    OBJECTS {
10578        tmnxChassisNotifyHwIndex,
10579        tmnxHwID,
10580        tmnxHwClass,
10581        tmnxCardComplexNumber,
10582        tmnxCardFwdDirection,
10583        tmnxCardSrcSlotBitmap
10584    }
10585    STATUS  current
10586    DESCRIPTION
10587        "The tmnxEqCardPChipError notification is generated when persistent FCS
10588         errors are detected by the P chip in either the ingress or egress
10589         datapath/complex.  The value tmnxCardSrcSlotBitmap is only used for the
10590         egress datapath/complex direction."
10591    ::= { tmnxChassisNotification 47 }
10592
10593tmnxEqCardSoftResetAlarm         NOTIFICATION-TYPE
10594    OBJECTS {
10595        tmnxChassisNotifyHwIndex,
10596        tmnxHwID,
10597        tmnxHwClass,
10598        tmnxCardSoftResetState
10599    }
10600    STATUS      current
10601    DESCRIPTION
10602        "The tmnxEqCardSoftResetAlarm notification is generated when an IOM
10603         card enters and exits the 'soft-reset' state."
10604   ::= { tmnxChassisNotification 48 }
10605
10606tmnxEqMdaSyncENotCompatible      NOTIFICATION-TYPE
10607    OBJECTS {
10608        tmnxChassisNotifyHwIndex,
10609        tmnxHwID,
10610        tmnxHwClass,
10611        tmnxMdaNotifyType
10612    }
10613    STATUS      current
10614    DESCRIPTION
10615        "The tmnxEqMdaSyncENotCompatible notification is generated when an
10616         MDA card is inserted into a slot of an IOM. The MDA is compatible
10617         with the currently provisioned MDA, but the currently configured
10618         synchronous ethernet, tmnxMDASynchronousEthernet, is not compatible
10619         with the inserted MDA.
10620
10621         [EFFECT] Though services can still be created, if the tmnxMdaNotifyType
10622         is the same as the tmnxMDAEquippedType then the MDA will fail to
10623         operate as configured and will be in a failed state.
10624
10625         [RECOVERY] Change the configuration to reflect the capabilities of the
10626         MDA port, or switch out/re-provision the MDA for one that is
10627         compatible."
10628   ::= { tmnxChassisNotification 49 }
10629
10630tmnxIPsecIsaGrpActiveIsaChgd      NOTIFICATION-TYPE
10631    OBJECTS {
10632        tmnxIPsecIsaGrpPrimaryIsa,
10633        tmnxIPsecIsaGrpBackupIsa,
10634        tmnxIPsecIsaGrpActiveIsa
10635    }
10636    STATUS      current
10637    DESCRIPTION
10638        "The tmnxIPsecIsaGrpActiveIsaChgd notification is generated when a
10639         change in the active ISA (Integrated Service Adaptor) occurs in a
10640         IPsec ISA module group."
10641   ::= { tmnxChassisNotification 50 }
10642
10643tmnxEqCardPChipMemoryEvent     NOTIFICATION-TYPE
10644    OBJECTS {
10645        tmnxChassisNotifyHwIndex,
10646        tmnxHwID,
10647        tmnxHwClass,
10648        tmnxCardComplexNumber
10649    }
10650    STATUS  current
10651    DESCRIPTION
10652        "The tmnxEqCardPChipMemoryEvent notification is generated when
10653         a P-chip experiences an occurrence of a memory parity error."
10654    ::= { tmnxChassisNotification 51 }
10655
10656tmnxIPsecIsaGrpUnableToSwitch      NOTIFICATION-TYPE
10657    OBJECTS {
10658        tmnxIPsecIsaGrpActiveIsa
10659    }
10660    STATUS current
10661    DESCRIPTION
10662        "The tmnxIPsecIsaGrpUnableToSwitch notification is generated when
10663         an IPsec ISA (Integrated Service Adaptor) module group is unable
10664         to switch due to lack of resources.
10665
10666         In such an event the ISA group is left without an active MDA and
10667         the tmnxIPsecIsaGrpOperState is set to 'outOfService'.
10668
10669         Recovery is possible by releasing resources, and setting the
10670         tmnxIPsecIsaGrpAdminState object to 'outOfService' followed by a
10671         reset to 'inService' to bring up the ISA group."
10672    ::= { tmnxChassisNotification 52 }
10673
10674tmnxIPsecIsaGrpTnlLowWMark      NOTIFICATION-TYPE
10675    OBJECTS {
10676        tmnxIPsecIsaGrpTunnels,
10677        tmnxIPsecIsaGrpMaxTunnels
10678    }
10679    STATUS current
10680    DESCRIPTION
10681        "The tmnxIPsecIsaGrpTnlLowWMark notification is generated when
10682         number of tunnels for an IPsec ISA (Integrated Service Adaptor) module
10683         has dropped to the low watermark which is 90% of the
10684         tmnxIPsecIsaGrpMaxTunnels."
10685    ::= { tmnxChassisNotification 53 }
10686
10687tmnxIPsecIsaGrpTnlHighWMark      NOTIFICATION-TYPE
10688    OBJECTS {
10689        tmnxIPsecIsaGrpTunnels,
10690        tmnxIPsecIsaGrpMaxTunnels
10691    }
10692    STATUS current
10693    DESCRIPTION
10694        "The tmnxIPsecIsaGrpTnlHighWMark notification is generated when
10695         number of tunnels for an IPsec ISA (Integrated Service Adaptor) module
10696         has reached to the high watermark which is 95% of the
10697         tmnxIPsecIsaGrpMaxTunnels."
10698    ::= { tmnxChassisNotification 54 }
10699
10700tmnxIPsecIsaGrpTnlMax     NOTIFICATION-TYPE
10701    OBJECTS {
10702        tmnxIPsecIsaGrpTunnels,
10703        tmnxIPsecIsaGrpMaxTunnels
10704    }
10705    STATUS current
10706    DESCRIPTION
10707        "The tmnxIPsecIsaGrpTnlMax notification is generated when
10708         number of tunnels for an IPsec ISA (Integrated Service Adaptor) module
10709         has reached the maximum of the tmnxIPsecIsaGrpMaxTunnels."
10710    ::= { tmnxChassisNotification 55 }
10711
10712tmnxEqSyncIfTimingRef1Quality    NOTIFICATION-TYPE
10713    OBJECTS {
10714        tmnxSyncIfTimingRef1RxQltyLevel
10715    }
10716    STATUS      current
10717    DESCRIPTION
10718        "Generated when there is a change of the received quality level
10719         on timing reference 1."
10720    ::= { tmnxChassisNotification 56 }
10721
10722tmnxEqSyncIfTimingRef2Quality    NOTIFICATION-TYPE
10723    OBJECTS {
10724        tmnxSyncIfTimingRef2RxQltyLevel
10725    }
10726    STATUS      current
10727    DESCRIPTION
10728        "Generated when there is a change of the received quality level
10729         on timing reference 2."
10730    ::= { tmnxChassisNotification 57 }
10731
10732tmnxEqSyncIfTimingBITSQuality    NOTIFICATION-TYPE
10733    OBJECTS {
10734        tmnxSyncIfTimingBITSRxQltyLevel
10735    }
10736    STATUS      current
10737    DESCRIPTION
10738        "Generated when there is a change of the received quality level
10739         on the bits interface."
10740    ::= { tmnxChassisNotification 58 }
10741
10742tmnxEqSyncIfTimingBITS2Quality   NOTIFICATION-TYPE
10743    OBJECTS {
10744        tmnxSyncIfTimingBITS2RxQltyLevel
10745    }
10746    STATUS      current
10747    DESCRIPTION
10748        "Generated when there is a change of the received quality level
10749         on the second bits interface."
10750    ::= { tmnxChassisNotification 59 }
10751
10752tmnxEqSyncIfTimingRefSwitch      NOTIFICATION-TYPE
10753    OBJECTS {
10754        tmnxSyncIfTimingRef1InUse,
10755        tmnxSyncIfTimingRef2InUse,
10756        tmnxSyncIfTimingBITSInUse,
10757        tmnxSyncIfTimingBITS2InUse,
10758        tmnxSyncIfTimingPTPInUse
10759    }
10760    STATUS      current
10761    DESCRIPTION
10762        "Generated when there is a change of which timing reference
10763         is providing timing for the system."
10764    ::= { tmnxChassisNotification 60 }
10765
10766tmnxEqSyncIfTimingBITS2Alarm   NOTIFICATION-TYPE
10767    OBJECTS {
10768        tmnxChassisNotifyHwIndex,
10769        tmnxHwID,
10770        tmnxHwClass,
10771        tmnxSyncIfTimingNotifyAlarm
10772    }
10773    STATUS current
10774    DESCRIPTION
10775        "Generated when an alarm condition on the BITS 2 timing
10776         reference is detected.
10777         This notification will have the same indices as those of
10778         the tmnxCpmCardTable."
10779    ::= { tmnxChassisNotification 61 }
10780
10781tmnxEqSyncIfTimingBITS2AlarmClr   NOTIFICATION-TYPE
10782    OBJECTS {
10783        tmnxChassisNotifyHwIndex,
10784        tmnxHwID,
10785        tmnxHwClass,
10786        tmnxSyncIfTimingNotifyAlarm
10787    }
10788    STATUS current
10789    DESCRIPTION
10790        "Generated when an alarm condition on the BITS 2 timing
10791         reference is cleared.
10792         This notification will have the same indices as those of
10793         the tmnxCpmCardTable."
10794    ::= { tmnxChassisNotification 62 }
10795
10796tmnxEqSyncIfTimingBITSOutRefChg  NOTIFICATION-TYPE
10797    OBJECTS     {
10798                    tmnxSyncIfTimingBITSOutRefSel
10799                }
10800    STATUS      current
10801    DESCRIPTION
10802        "Generated when the BITS Out timing reference selection changes."
10803    ::= { tmnxChassisNotification 63 }
10804
10805tmnxEqCardPChipCamEvent        NOTIFICATION-TYPE
10806    OBJECTS {
10807        tmnxChassisNotifyHwIndex,
10808        tmnxHwID,
10809        tmnxHwClass,
10810        tmnxCardComplexNumber
10811    }
10812    STATUS  current
10813    DESCRIPTION
10814        "The tmnxEqCardPChipCamEvent notification is generated when either an
10815         IOM or a CPM experiences a persistent occurrence of a PChip CAM error.
10816         On a CPM card, the tmnxCardComplexNumber will be fixed to the value
10817         zero (0)."
10818    ::= { tmnxChassisNotification 64 }
10819
10820tmnxEqSyncIfTimingSystemQuality  NOTIFICATION-TYPE
10821    OBJECTS     {
10822                    tmnxSyncIfTimingSystemQltyLevel
10823                }
10824    STATUS      current
10825    DESCRIPTION
10826        "The tmnxEqSyncIfTimingSystemQuality notification is generated when
10827         there is a change in the system timing quality level. This
10828         notification is a point-in-time state change event.
10829
10830         [CAUSE] This notification may be triggered for the following reasons:
10831
10832         1) There has been a switch in the timing reference in use by the
10833            network element, either because the previously active timing
10834            reference was disqualified, or to ensure that the network element
10835            is using the timing reference with the best timing quality.
10836         2) There has been a change in the active timing reference's quality
10837            and the change does not result in a timing reference switch.
10838         3) The network element has transitioned into or out of the holdover
10839            state.
10840
10841         [EFFECT] The system quality level is used to determine the SSM code
10842         transmitted on synchronous interfaces. This may affect the SSM code
10843         transmitted on some or all interfaces, which may affect the
10844         distribution of timing throughout the network.
10845
10846         [RECOVERY] If the customer is expecting the system to be locked to a
10847         reference of a particular quality and the system quality has
10848         decreased, the customer will need to determine the root cause (for
10849         example, loss of communication with a satellite) and resolve the
10850         issue."
10851    ::= { tmnxChassisNotification 65 }
10852
10853tmnxEqHwEnhancedCapability      NOTIFICATION-TYPE
10854    OBJECTS     {
10855                    tmnxChassisNotifyHwIndex,
10856                    tmnxHwID,
10857                    tmnxHwClass
10858                }
10859    STATUS      current
10860    DESCRIPTION
10861        "The tmnxEqHwEnhancedCapability notification is generated when the
10862         hardware, specified by the supplied objects, consists of enhanced
10863         capabilities as compared to the active hardware.
10864
10865         [EFFECT] The system behaves normally under this situation, however,
10866         switching to the newer hardware will put the system in an incompatible
10867         state with the currently active hardware. That is, once this device
10868         takes activity, the lesser capable hardware will fail to communicate
10869         with it.
10870
10871         In this mode, the system is deemed to be in a 'one-way upgrade'
10872         scenario.
10873
10874         [RECOVERY] Two modes of recovery exist for this notification.
10875            1. Remove the enhanced hardware, and supply a more compatible
10876               device (status quo) with the active hardware, or
10877            2. Switch to the enhanced device, and replace the older hardware
10878               with a similarly enhanced device (upgrade)."
10879   ::= { tmnxChassisNotification 66 }
10880
10881tmnxEqSyncIfTimingPTPQuality     NOTIFICATION-TYPE
10882    OBJECTS {
10883        tmnxSyncIfTimingPTPRxQltyLevel
10884    }
10885    STATUS      current
10886    DESCRIPTION
10887        "Generated when there is a change of the received quality level
10888         on the Precision Timing Protocol (PTP)."
10889    ::= { tmnxChassisNotification 67 }
10890
10891tmnxEqSyncIfTimingPTPAlarm       NOTIFICATION-TYPE
10892    OBJECTS {
10893        tmnxChassisNotifyHwIndex,
10894        tmnxHwID,
10895        tmnxHwClass,
10896        tmnxSyncIfTimingNotifyAlarm
10897    }
10898    STATUS current
10899    DESCRIPTION
10900        "Generated when an alarm condition on the Precision Timing Protocol
10901         (PTP) timing reference is detected.
10902         This notification will have the same indices as those of the
10903         tmnxCpmCardTable."
10904    ::= { tmnxChassisNotification 68 }
10905
10906tmnxEqSyncIfTimingPTPAlarmClear  NOTIFICATION-TYPE
10907    OBJECTS {
10908        tmnxChassisNotifyHwIndex,
10909        tmnxHwID,
10910        tmnxHwClass,
10911        tmnxSyncIfTimingNotifyAlarm
10912    }
10913    STATUS current
10914    DESCRIPTION
10915        "Generated when an alarm condition on the Precision Timing Protocol
10916         (PTP) timing reference is cleared.
10917         This notification will have the same indices as those of the
10918         tmnxCpmCardTable."
10919    ::= { tmnxChassisNotification 69 }
10920
10921tmnxPeFirmwareVersionWarning    NOTIFICATION-TYPE
10922    OBJECTS {
10923        tmnxChassisNotifyHwIndex,
10924        tmnxHwID,
10925        tmnxHwClass,
10926        tmnxHwFirmwareCodeVersion
10927    }
10928    STATUS  current
10929    DESCRIPTION
10930        "Generated when a card is running compatible yet older firmware
10931         than the firmware associated with the current software release.
10932         tmnxChassisNotifyHwIndex identifies the card.  The
10933         tmnxHwFirmwareCodeVersion object will contain the programmed
10934         the firmware version."
10935    ::= { tmnxChassisNotification 70 }
10936
10937tmnxMDAIsaTunnelGroupChange     NOTIFICATION-TYPE
10938    OBJECTS {
10939        tmnxMDAIsaTunnelGroupInUse,
10940        tmnxMDAIsaTunnelGroup
10941    }
10942    STATUS current
10943    DESCRIPTION
10944        "[CAUSE] The tmnxMDAIsaTunnelGroupChange notification is generated when
10945         IPsec ISA (Integrated Service Adaptor) tunnel-group in-use for the MDA
10946         changes value.
10947
10948         [EFFECT] There is no operational impact due to this event.
10949
10950         [RECOVERY] None required."
10951    ::= { tmnxChassisNotification 71 }
10952
10953--
10954--
10955--
10956
10957--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
10958--
10959--      TMNX-HW-MIB Object Groups
10960--
10961
10962
10963
10964--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
10965--
10966--      The compliance specifications.
10967--
10968
10969tmnxChassisCompliances  OBJECT IDENTIFIER ::= { tmnxChassisConformance 1 }
10970tmnxChassisGroups       OBJECT IDENTIFIER ::= { tmnxChassisConformance 2 }
10971
10972-- compliance statements
10973
10974-- tmnxChassisCompliance  MODULE-COMPLIANCE
10975--    ::= { tmnxChassisCompliances 1 }
10976
10977-- tmnxChassisR2r1Compliance  MODULE-COMPLIANCE
10978--    ::= { tmnxChassisCompliances 2 }
10979
10980-- tmnxChassisV3v0Compliance  MODULE-COMPLIANCE
10981--    ::= { tmnxChassisCompliances 3 }
10982
10983tmnxChassisV4v0Compliance  MODULE-COMPLIANCE
10984    STATUS  obsolete
10985    DESCRIPTION
10986            "The compliance statement for management of chassis features
10987             in the TIMETRA-CHASSIS-MIB."
10988    MODULE  -- this module
10989        MANDATORY-GROUPS {
10990            tmnxChassisV3v0Group,
10991            tmnxCardV3v0Group,
10992            tmnxMDAV4v0Group,
10993            tmnxChassisNotificationV4v0Group
10994        }
10995    ::= { tmnxChassisCompliances 4 }
10996
10997tmnxChassisV5v0Compliance  MODULE-COMPLIANCE
10998    STATUS  obsolete
10999    DESCRIPTION
11000            "The compliance statement for management of chassis features
11001             in the TIMETRA-CHASSIS-MIB."
11002    MODULE  -- this module
11003        MANDATORY-GROUPS {
11004            tmnxChassisV5v0Group,
11005            tmnxCardV3v0Group,
11006            tmnxMDAV4v0Group,
11007            tmnxChassisNotificationV4v0Group,
11008            tmnxChassisNotificationV5v0Group,
11009            tmnxMdaXplV5v0Group,
11010            tmnxCardPchipV5v0Group
11011        }
11012    ::= { tmnxChassisCompliances 6 }
11013
11014tmnxChassis7750V6v0Compliance  MODULE-COMPLIANCE
11015    STATUS  obsolete
11016    DESCRIPTION
11017            "The compliance statement for management of chassis features
11018             on the 7750 in the TIMETRA-CHASSIS-MIB."
11019    MODULE  -- this module
11020        MANDATORY-GROUPS {
11021            tmnxChassisV5v0Group,
11022            tmnxCardV3v0Group,
11023            tmnxMDAV4v0Group,
11024            tmnxChassisNotificationV6v0Group,
11025            tmnx77x0CESMDAV6v0Group,
11026            tmnxCardV6v0NamedPoolPlcyGroup,
11027            tmnxIPsecIsaGrpV6v0Group,
11028            -- tmnx7710HwV3v0Group
11029            -- tmnx7710SETSRefSrcHwV6v0Group
11030            tmnxChassisHsmdaV6v0Group,
11031            tmnxMDAMcPathMgmtV6v0Group,
11032            tmnxMdaXplV5v0Group,
11033            tmnxCardPchipV5v0Group,
11034            tmnxSyncV6v0Group,
11035            tmnxChassisV6v0Group
11036        }
11037    ::= { tmnxChassisCompliances 7 }
11038
11039tmnxChassis7450V6v0Compliance  MODULE-COMPLIANCE
11040    STATUS  obsolete
11041    DESCRIPTION
11042            "The compliance statement for management of chassis features
11043             on the 7450 in the TIMETRA-CHASSIS-MIB."
11044    MODULE  -- this module
11045        MANDATORY-GROUPS {
11046            tmnxChassisV5v0Group,
11047            tmnxCardV3v0Group,
11048            tmnxMDAV4v0Group,
11049            tmnxCardV6v0NamedPoolPlcyGroup,
11050            tmnxChassisNotificationV6v0Group,
11051            -- tmnx77x0CESMDAV6v0Group
11052            -- tmnxIPsecIsaGrpV6v0Group
11053            -- tmnx7710HwV3v0Group
11054            -- tmnx7710SETSRefSrcHwV6v0Group
11055            tmnxChassisHsmdaV6v0Group,
11056            tmnxMDAMcPathMgmtV6v0Group,
11057            tmnxMdaXplV5v0Group,
11058            tmnxCardPchipV5v0Group,
11059            tmnxSyncV6v0Group,
11060            tmnxChassisV6v0Group
11061        }
11062    ::= { tmnxChassisCompliances 8 }
11063
11064tmnxChassis7750V6v1Compliance  MODULE-COMPLIANCE
11065    STATUS  obsolete
11066    DESCRIPTION
11067            "The compliance statement for management of chassis features
11068             on the 7750 in the TIMETRA-CHASSIS-MIB."
11069    MODULE  -- this module
11070        MANDATORY-GROUPS {
11071            tmnxChassisV5v0Group,
11072            tmnxCardV3v0Group,
11073            tmnxMDAV6v1Group,
11074            tmnxChassisNotificationV6v0Group,
11075            tmnx77x0CESMDAV6v0Group,
11076            tmnxCardV6v0NamedPoolPlcyGroup,
11077            tmnxIPsecIsaGrpV6v0Group,
11078            -- tmnx7710HwV3v0Group
11079            -- tmnx7710SETSRefSrcHwV6v0Group
11080            tmnxChassisHsmdaV6v0Group,
11081            tmnxMDAMcPathMgmtV6v0Group,
11082            tmnxChassisV6v1Group,
11083            tmnxFPMcPathMgmtV6v1Group,
11084            tmnxMDACcagV6v1Group,
11085            tmnxMdaXplV5v0Group,
11086            tmnxCardPchipV5v0Group,
11087            tmnxCardCamErrorV6v1Group,
11088            tmnxSyncV6v0Group,
11089            tmnxChassisHwV6v1Group
11090        }
11091    ::= { tmnxChassisCompliances 9 }
11092
11093tmnxChassis7450V6v1Compliance  MODULE-COMPLIANCE
11094    STATUS  obsolete
11095    DESCRIPTION
11096            "The compliance statement for management of chassis features
11097             on the 7450 in the TIMETRA-CHASSIS-MIB."
11098    MODULE  -- this module
11099        MANDATORY-GROUPS {
11100            tmnxChassisV5v0Group,
11101            tmnxCardV3v0Group,
11102            tmnxMDAV6v1Group,
11103            tmnxCardV6v0NamedPoolPlcyGroup,
11104            tmnxChassisNotificationV6v0Group,
11105            -- tmnx77x0CESMDAV6v0Group
11106            -- tmnxIPsecIsaGrpV6v0Group
11107            -- tmnx7710HwV3v0Group
11108            -- tmnx7710SETSRefSrcHwV6v0Group
11109            tmnxChassisHsmdaV6v0Group,
11110            tmnxMDAMcPathMgmtV6v0Group,
11111            tmnxChassisV6v1Group,
11112            tmnxFPMcPathMgmtV6v1Group,
11113            tmnxMDACcagV6v1Group,
11114            tmnxMdaXplV5v0Group,
11115            tmnxCardPchipV5v0Group,
11116            tmnxCardCamErrorV6v1Group,
11117            tmnxSyncV6v0Group,
11118            tmnxChassisHwV6v1Group
11119        }
11120    ::= { tmnxChassisCompliances 10 }
11121
11122tmnxChassis7750V7v0Compliance  MODULE-COMPLIANCE
11123    STATUS obsolete
11124    DESCRIPTION
11125            "The compliance statement for management of chassis features
11126             on the 7750 in the TIMETRA-CHASSIS-MIB."
11127    MODULE  -- this module
11128        MANDATORY-GROUPS {
11129            tmnxChassisV5v0Group,
11130            tmnxCardV3v0Group,
11131            tmnxMDAV6v1Group,
11132            tmnxChassisNotificationV7v0Group,
11133            tmnx77x0CESMDAV6v0Group,
11134            tmnxCardV6v0NamedPoolPlcyGroup,
11135            tmnxIPsecIsaGrpV6v0Group,
11136            -- tmnx7710HwV3v0Group
11137            -- tmnx7710SETSRefSrcHwV6v0Group
11138            tmnxChassisHsmdaV6v0Group,
11139            tmnxMDAMcPathMgmtV6v0Group,
11140            tmnxChassisV6v1Group,
11141            -- tmnxChassisV7v0Group,
11142            tmnxFPMcPathMgmtV6v1Group,
11143            tmnxMDACcagV6v1Group,
11144            tmnxChassisUserModV7v0Group,
11145            tmnxCardV7v0Group,
11146            tmnxFPWredV7v0Group,
11147            tmnxIPsecV7v0Group,
11148            tmnxIPsecNotifV7v0Group,
11149            tmnxMdaXplV5v0Group,
11150            tmnxCardPchipV5v0Group,
11151            tmnxCardCamErrorV6v1Group,
11152            tmnxSyncV6v0Group,
11153            tmnxChassisHwV6v1Group
11154        }
11155    ::= { tmnxChassisCompliances 11 }
11156
11157tmnxChassis7450V7v0Compliance  MODULE-COMPLIANCE
11158    STATUS obsolete
11159    DESCRIPTION
11160            "The compliance statement for management of chassis features
11161             on the 7450 in the TIMETRA-CHASSIS-MIB."
11162    MODULE  -- this module
11163        MANDATORY-GROUPS {
11164            tmnxChassisV5v0Group,
11165            tmnxCardV3v0Group,
11166            tmnxMDAV6v1Group,
11167            tmnxCardV6v0NamedPoolPlcyGroup,
11168            tmnxChassisNotificationV7v0Group,
11169            -- tmnx77x0CESMDAV6v0Group
11170            -- tmnxIPsecIsaGrpV6v0Group
11171            -- tmnx7710HwV3v0Group
11172            -- tmnx7710SETSRefSrcHwV6v0Group
11173            tmnxChassisHsmdaV6v0Group,
11174            tmnxMDAMcPathMgmtV6v0Group,
11175            tmnxChassisV6v1Group,
11176            -- tmnxChassisV7v0Group,
11177            tmnxFPMcPathMgmtV6v1Group,
11178            tmnxMDACcagV6v1Group,
11179            tmnxChassisUserModV7v0Group,
11180            tmnxCardV7v0Group,
11181            tmnxFPWredV7v0Group,
11182            tmnxMdaXplV5v0Group,
11183            tmnxCardPchipV5v0Group,
11184            tmnxCardCamErrorV6v1Group,
11185            tmnxSyncV6v0Group,
11186            tmnxChassisHwV6v1Group
11187        }
11188    ::= { tmnxChassisCompliances 12 }
11189
11190tmnxChassis7x50V8v0Compliance  MODULE-COMPLIANCE
11191    STATUS  obsolete
11192    DESCRIPTION
11193            "The compliance statement for management of chassis features
11194             on the 7x50 in the TIMETRA-CHASSIS-MIB."
11195    MODULE  -- this module
11196        MANDATORY-GROUPS {
11197            tmnxChassisV5v0Group,
11198            tmnxChassisV8v0Group,
11199            tmnxCardV3v0Group,
11200            tmnxMDAV6v1Group,
11201            tmnxChassisNotificationV7v0Group,
11202            tmnx77x0CESMDAV6v0Group,
11203            tmnxCardV6v0NamedPoolPlcyGroup,
11204            tmnxIPsecIsaGrpV6v0Group,
11205            tmnx7710HwV3v0Group,
11206            tmnx7710SETSRefSrcHwV6v0Group,
11207            tmnxChassisHsmdaV6v0Group,
11208            tmnxMDAMcPathMgmtV6v0Group,
11209            tmnxChassisV6v1Group,
11210            tmnxChassisV7v0Group,
11211            tmnxFPMcPathMgmtV6v1Group,
11212            tmnxMDACcagV6v1Group,
11213            tmnxChassisUserModV7v0Group,
11214            tmnxCardV7v0Group,
11215            tmnxFPWredV7v0Group,
11216            tmnxIPsecV7v0Group,
11217            tmnxIPsecNotifV7v0Group,
11218            tmnxSyncIfTimingV8v0Group,
11219            tmnxChassisMixedModeIomV8v0Group,
11220            tmnxMdaXplV5v0Group,
11221            tmnxCardPchipV5v0Group,
11222            tmnxCardPchipV8v0Group,
11223            tmnxCardCamErrorV6v1Group,
11224            tmnxSyncV6v0Group,
11225            tmnxSyncIfTimingNotifV8v0Group,
11226            tmnxChassisHwV6v1Group
11227        }
11228    ::= { tmnxChassisCompliances 13 }
11229
11230tmnxChassisV9v0Compliance        MODULE-COMPLIANCE
11231    STATUS  obsolete
11232    DESCRIPTION
11233            "The compliance statement for management of chassis features
11234             on SROS series systems in the TIMETRA-CHASSIS-MIB."
11235    MODULE  -- this module
11236        MANDATORY-GROUPS {
11237            tmnx7710HwV3v0Group,
11238            tmnx7710SETSRefSrcHwV6v0Group,
11239            tmnx77x0CESMDAV6v0Group,
11240            tmnxAtmGroup,
11241            tmnxCardCamErrorV6v1Group,
11242            tmnxCardPchipV5v0Group,
11243            tmnxCardPchipV8v0Group,
11244            tmnxCardV3v0Group,
11245            tmnxCardV6v0NamedPoolPlcyGroup,
11246            tmnxCardV7v0Group,
11247            tmnxChassisHsmdaV6v0Group,
11248            tmnxChassisHwV6v1Group,
11249            tmnxChassisHwV9v0Group,
11250            tmnxChassisMixedModeIomV8v0Group,
11251            tmnxChassisNotificationV7v0Group,
11252            tmnxChassisNotificationV9v0Group,
11253            tmnxChassisUserModV7v0Group,
11254            tmnxChassisV5v0Group,
11255            tmnxChassisV6v1Group,
11256            tmnxChassisV7v0Group,
11257            tmnxChassisV8v0Group,
11258            tmnxFPMcPathMgmtV6v1Group,
11259            tmnxFPWredV7v0Group,
11260            tmnxIPsecIsaGrpV6v0Group,
11261            tmnxIPsecNotifV7v0Group,
11262            tmnxIPsecV7v0Group,
11263            tmnxMDACcagV6v1Group,
11264            tmnxMDAMcPathMgmtV6v0Group,
11265            tmnxMDAV6v1Group,
11266            tmnxMDAV9v0Group,
11267            tmnxMdaXplV5v0Group,
11268            tmnxSyncIfTimingNotifV8v0Group,
11269            tmnxSyncIfTimingNotifyV9v0Group,
11270            tmnxSyncIfTimingV8v0Group,
11271            tmnxSyncIfTimingV9v0Group,
11272            tmnxSyncV6v0Group
11273        }
11274    ::= { tmnxChassisCompliances 14 }
11275
11276tmnxChassisV10v0Compliance        MODULE-COMPLIANCE
11277    STATUS  current
11278    DESCRIPTION
11279            "The compliance statement for management of chassis features
11280             on SROS series systems in the TIMETRA-CHASSIS-MIB."
11281    MODULE  -- this module
11282        MANDATORY-GROUPS {
11283            tmnx7710HwV3v0Group,
11284            tmnx7710SETSRefSrcHwV6v0Group,
11285            tmnx77x0CESMDAV6v0Group,
11286            tmnxAtmGroup,
11287            tmnxCardCamErrorV6v1Group,
11288            tmnxCardPchipV5v0Group,
11289            tmnxCardPchipV8v0Group,
11290            tmnxCardV3v0Group,
11291            tmnxCardV6v0NamedPoolPlcyGroup,
11292            tmnxCardV7v0Group,
11293            -- tmnxChassisHsmdaV6v0Group,
11294            tmnxChassisHwV6v1Group,
11295            tmnxChassisHwV9v0Group,
11296            tmnxChassisMixedModeIomV8v0Group,
11297            tmnxChassisNotificationV7v0Group,
11298            tmnxChassisNotificationV9v0Group,
11299            tmnxChassisUserModV7v0Group,
11300            tmnxChassisV5v0Group,
11301            tmnxChassisV6v1Group,
11302            tmnxChassisV7v0Group,
11303            tmnxChassisV8v0Group,
11304            tmnxChassisV10v0Group,
11305            tmnxFPMcPathMgmtV6v1Group,
11306            tmnxFPWredV7v0Group,
11307            tmnxIPsecIsaGrpV6v0Group,
11308            tmnxIPsecNotifV7v0Group,
11309            tmnxIPsecV7v0Group,
11310            tmnxMDACcagV6v1Group,
11311            tmnxMDAMcPathMgmtV6v0Group,
11312            tmnxMDAV6v1Group,
11313            tmnxMDAV9v0Group,
11314            tmnxMdaXplV5v0Group,
11315            tmnxSyncIfTimingNotifV8v0Group,
11316            tmnxSyncIfTimingNotifyV9v0Group,
11317            tmnxSyncIfTimingV8v0Group,
11318            tmnxSyncIfTimingV9v0Group,
11319            tmnxSyncV6v0Group,
11320            tmnxCardV10v0Group,
11321            tmnxIpsecV10v0Group,
11322            tmnxFPQGrpGroup,
11323            tmnxFPQGrpV10v0R4Group,
11324            tmnxChassisNotifyV10v0Group,
11325            tmnxMdaV10v0Group,
11326            tmnxMdaHsmdaPoolV10v0Group
11327        }
11328    ::= { tmnxChassisCompliances 15 }
11329
11330tmnxChassisComp7710     OBJECT IDENTIFIER ::= { tmnxChassisCompliances 5 }
11331
11332tmnxChassisComp7710V3v0  MODULE-COMPLIANCE
11333    STATUS  obsolete
11334    DESCRIPTION
11335            "The compliance statement for management of chassis features
11336             for the 7710 in the TIMETRA-CHASSIS-MIB."
11337    MODULE  -- this module
11338        MANDATORY-GROUPS {
11339            tmnxChassisV3v0Group,
11340            tmnxCardV3v0Group,
11341            tmnxMDAV3v0Group,
11342            tmnxChassisNotificationV3v0Group,
11343            tmnx7710HwV3v0Group
11344        }
11345    ::= { tmnxChassisComp7710 1 }
11346
11347tmnxChassisComp7710V5v0  MODULE-COMPLIANCE
11348    STATUS  obsolete
11349    DESCRIPTION
11350            "The compliance statement for management of chassis features
11351             for the 7710 in the TIMETRA-CHASSIS-MIB."
11352    MODULE  -- this module
11353        MANDATORY-GROUPS {
11354            tmnxChassisV5v0Group,
11355            tmnxCardV3v0Group,
11356            tmnxMDAV4v0Group,
11357            tmnxChassisNotificationV4v0Group,
11358            tmnx7710HwV3v0Group
11359        }
11360    ::= { tmnxChassisComp7710 2 }
11361
11362tmnxChassisComp7710V6v0  MODULE-COMPLIANCE
11363    STATUS  obsolete
11364    DESCRIPTION
11365            "The compliance statement for management of chassis features
11366             for the 7710 in the TIMETRA-CHASSIS-MIB."
11367    MODULE  -- this module
11368        MANDATORY-GROUPS {
11369            tmnxChassisV5v0Group,
11370            tmnxCardV3v0Group,
11371            tmnxMDAV4v0Group,
11372            tmnxChassisNotificationV6v0Group,
11373            tmnx7710HwV3v0Group,
11374            tmnx77x0CESMDAV6v0Group,
11375            tmnxIPsecIsaGrpV6v0Group,
11376            tmnx7710SETSRefSrcHwV6v0Group,
11377            tmnxCardV6v0NamedPoolPlcyGroup,
11378            -- tmnxChassisHsmdaV6v0Group
11379            -- tmnxMDAMcPathMgmtV6v0Group
11380            tmnxSyncV6v0Group,
11381            tmnxChassisV6v0Group
11382        }
11383    ::= { tmnxChassisComp7710 3 }
11384
11385tmnxChassisComp7710V6v1  MODULE-COMPLIANCE
11386    STATUS  obsolete
11387    DESCRIPTION
11388            "The compliance statement for management of chassis features
11389             for the 7710 in the TIMETRA-CHASSIS-MIB."
11390    MODULE  -- this module
11391        MANDATORY-GROUPS {
11392            tmnxChassisV5v0Group,
11393            tmnxCardV3v0Group,
11394            tmnxMDAV6v1Group,
11395            tmnxChassisNotificationV6v1Group,
11396            tmnx7710HwV3v0Group,
11397            tmnx77x0CESMDAV6v0Group,
11398            tmnxIPsecIsaGrpV6v0Group,
11399            tmnx7710SETSRefSrcHwV6v0Group,
11400            tmnxCardV6v0NamedPoolPlcyGroup,
11401            -- tmnxChassisHsmdaV6v0Group
11402            -- tmnxFPMcPathMgmtV6v1Group
11403            -- tmnxMDAMcPathMgmtV6v0Group
11404            tmnxChassisV6v1Group,
11405            tmnxMdaXplV5v0Group,
11406            tmnxCardPchipV5v0Group,
11407            tmnxCardCamErrorV6v1Group,
11408            tmnxSyncV6v0Group,
11409            tmnxChassisHwV6v1Group
11410        }
11411    ::= { tmnxChassisComp7710 4 }
11412
11413tmnxChassisComp7710V7v0  MODULE-COMPLIANCE
11414    STATUS  obsolete
11415    DESCRIPTION
11416            "The compliance statement for management of chassis features
11417             for the 7710 in the TIMETRA-CHASSIS-MIB."
11418    MODULE  -- this module
11419        MANDATORY-GROUPS {
11420            tmnxChassisV5v0Group,
11421            tmnxCardV3v0Group,
11422            tmnxMDAV6v1Group,
11423            tmnxChassisNotificationV7v0Group,
11424            tmnx7710HwV3v0Group,
11425            tmnx77x0CESMDAV6v0Group,
11426            tmnxIPsecIsaGrpV6v0Group,
11427            tmnx7710SETSRefSrcHwV6v0Group,
11428            tmnxCardV6v0NamedPoolPlcyGroup,
11429            -- tmnxChassisHsmdaV6v0Group
11430            -- tmnxFPMcPathMgmtV6v1Group
11431            -- tmnxMDAMcPathMgmtV6v0Group
11432            tmnxChassisV6v1Group,
11433            tmnxChassisV7v0Group,
11434            tmnxMdaXplV5v0Group,
11435            tmnxChassisUserModV7v0Group,
11436            tmnxCardPchipV5v0Group,
11437            tmnxCardCamErrorV6v1Group,
11438            tmnxCardV7v0Group,
11439            tmnxFPWredV7v0Group,
11440            tmnxIPsecV7v0Group,
11441            tmnxIPsecNotifV7v0Group,
11442            tmnxSyncV6v0Group,
11443            tmnxChassisHwV6v1Group
11444        }
11445    ::= { tmnxChassisComp7710 5 }
11446
11447tmnxChassisComp7710V8v0  MODULE-COMPLIANCE
11448    STATUS      obsolete
11449    DESCRIPTION
11450            "The compliance statement for management of chassis features
11451             for the 7710 in the TIMETRA-CHASSIS-MIB.
11452
11453             This MODULE-COMPLIANCE has been replaced by
11454             tmnxChassisV9v0Compliance."
11455    MODULE  -- this module
11456        MANDATORY-GROUPS {
11457            tmnxChassisV5v0Group,
11458            tmnxChassisV8v0Group,
11459            tmnxCardV3v0Group,
11460            tmnxMDAV6v1Group,
11461            tmnxChassisNotificationV7v0Group,
11462            tmnx7710HwV3v0Group,
11463            tmnx77x0CESMDAV6v0Group,
11464            tmnxIPsecIsaGrpV6v0Group,
11465            tmnx7710SETSRefSrcHwV6v0Group,
11466            tmnxCardV6v0NamedPoolPlcyGroup,
11467            -- tmnxChassisHsmdaV6v0Group
11468            -- tmnxFPMcPathMgmtV6v1Group
11469            -- tmnxMDAMcPathMgmtV6v0Group
11470            tmnxChassisV6v1Group,
11471            tmnxChassisV7v0Group,
11472            tmnxMdaXplV5v0Group,
11473            tmnxChassisUserModV7v0Group,
11474            tmnxCardPchipV5v0Group,
11475            tmnxCardPchipV8v0Group,
11476            tmnxCardCamErrorV6v1Group,
11477            tmnxCardV7v0Group,
11478            tmnxFPWredV7v0Group,
11479            tmnxIPsecV7v0Group,
11480            tmnxIPsecNotifV7v0Group,
11481            tmnxSyncIfTimingV8v0Group,
11482            tmnxSyncV6v0Group,
11483            tmnxSyncIfTimingNotifV8v0Group,
11484            tmnxChassisHwV6v1Group
11485        }
11486    ::= { tmnxChassisComp7710 6 }
11487
11488-- units of conformance
11489
11490-- tmnxChassisGroup   OBJECT-GROUP
11491--    ::= { tmnxChassisGroups 1 }
11492
11493-- tmnxCardGroup   OBJECT-GROUP
11494--    ::= { tmnxChassisGroups 2 }
11495
11496-- tmnxMDAGroup        OBJECT-GROUP
11497--    ::= { tmnxChassisGroups 3 }
11498
11499tmnxChassisNotifyObjsGroup   OBJECT-GROUP
11500    OBJECTS {   tmnxEqNotificationRow,
11501                tmnxEqTypeNotificationRow,
11502                tmnxChassisNotifyChassisId,
11503                tmnxChassisNotifyHwIndex,
11504                tmnxRedSecondaryCPMStatus,
11505                tmnxChassisNotifyOID,
11506                tmnxSyncIfTimingNotifyAlarm,
11507                tmnxChassisNotifyMismatchedVer,
11508                tmnxChassisNotifySoftwareLocation,
11509                tmnxChassisNotifyCardFailureReason
11510            }
11511    STATUS        current
11512    DESCRIPTION
11513        "The group of objects supporting chassis hardware notifications
11514         on Alcatel-Lucent SROS series systems."
11515    ::= { tmnxChassisGroups 4 }
11516
11517-- tmnxChassisNotificationGroup NOTIFICATION-GROUP
11518--    ::= { tmnxChassisGroups 5 }
11519
11520-- tmnxChassisNotificationR2r1Group NOTIFICATION-GROUP
11521--    ::= { tmnxChassisGroups 6 }
11522
11523tmnxChassisNotifyObsoleteGroup NOTIFICATION-GROUP
11524    NOTIFICATIONS   { tmnxHwConfigChange,
11525                      tmnxEqCpuFailure,
11526                      tmnxEqMemoryFailure,
11527                      tmnxEqBackdoorBusFailure,
11528                      tmnxPeSoftwareError,
11529                      tmnxPeSoftwareAbnormalHalt,
11530                      tmnxPeOutOfMemory,
11531                      tmnxPeConfigurationError,
11532                      tmnxPeStorageProblem,
11533                      tmnxPeCpuCyclesExceeded,
11534                      tmnxRedSecondaryCPMStatusChange,
11535                      tmnxRedRestoreSuccess,
11536                      tmnxRedRestoreFail
11537                    }
11538    STATUS        current
11539    DESCRIPTION
11540        "The group of notifications supporting the management of chassis
11541         hardware made obsolete for revision 2.1 on Alcatel-Lucent SROS
11542         series systems."
11543    ::= { tmnxChassisGroups 7 }
11544
11545-- tmnxChassisR2r1Group   OBJECT-GROUP
11546--    ::= { tmnxChassisGroups 8 }
11547
11548tmnxChassisV3v0Group   OBJECT-GROUP
11549    OBJECTS {   tmnxChassisTotalNumber,
11550                tmnxChassisLastChange,
11551                tmnxChassisRowStatus,
11552                tmnxChassisName,
11553                tmnxChassisType,
11554                tmnxChassisLocation,
11555                tmnxChassisCoordinates,
11556                tmnxChassisNumSlots,
11557                tmnxChassisNumPorts,
11558                tmnxChassisNumPwrSupplies,
11559                tmnxChassisNumFanTrays,
11560                tmnxChassisNumFans,
11561                tmnxChassisCriticalLEDState,
11562                tmnxChassisMajorLEDState,
11563                tmnxChassisMinorLEDState,
11564                tmnxChassisBaseMacAddress,
11565                tmnxChassisCLLICode,
11566                tmnxChassisReboot,
11567                tmnxChassisUpgrade,
11568                tmnxChassisAdminMode,
11569                tmnxChassisOperMode,
11570                tmnxChassisModeForce,
11571                tmnxChassisUpdateWaitTime,
11572                tmnxChassisUpdateTimeLeft,
11573                tmnxChassisFanOperStatus,
11574                tmnxChassisFanSpeed,
11575                tmnxChassisPowerSupplyACStatus,
11576                tmnxChassisPowerSupplyDCStatus,
11577                tmnxChassisPowerSupplyTempStatus,
11578                tmnxChassisPowerSupplyTempThreshold,
11579                tmnxChassisPowerSupply1Status,
11580                tmnxChassisPowerSupply2Status,
11581                tmnxChassisPowerSupplyAssignedType,
11582                tmnxChassisTypeName,
11583                tmnxChassisTypeDescription,
11584                tmnxChassisTypeStatus,
11585                tmnxHwLastChange,
11586                tmnxHwID,
11587                tmnxHwMfgString,
11588                tmnxHwMfgBoardNumber,
11589                tmnxHwSerialNumber,
11590                tmnxHwManufactureDate,
11591                tmnxHwClass,
11592                tmnxHwName,
11593                tmnxHwAlias,
11594                tmnxHwAssetID,
11595                tmnxHwCLEI,
11596                tmnxHwIsFRU,
11597                tmnxHwContainedIn,
11598                tmnxHwParentRelPos,
11599                tmnxHwAdminState,
11600                tmnxHwOperState,
11601                tmnxHwTempSensor,
11602                tmnxHwTemperature,
11603                tmnxHwTempThreshold,
11604                tmnxHwBootCodeVersion,
11605                tmnxHwSoftwareCodeVersion,
11606                tmnxHwSwLastBoot,
11607                tmnxHwAlarmState,
11608                tmnxHwLastAlarmEvent,
11609                tmnxHwClearAlarms,
11610                tmnxHwSwImageSource,
11611                tmnxHwMfgDeviations,
11612                tmnxHwBaseMacAddress,
11613                tmnxHwFailureReason,
11614                tmnxHwContainedIndex
11615            }
11616    STATUS        obsolete
11617    DESCRIPTION
11618        "The group of objects supporting management of chassis hardware
11619         capabilities on release 3.0 of  Alcatel-Lucent SROS series systems."
11620    ::= { tmnxChassisGroups 9 }
11621
11622tmnxMDAV3v0Group        OBJECT-GROUP
11623    OBJECTS {   tmnxMDASupportedTypes,
11624                tmnxMDAAssignedType,
11625                tmnxMDAEquippedType,
11626                tmnxMDAHwIndex,
11627                tmnxMDAMaxPorts,
11628                tmnxMDAEquippedPorts,
11629                tmnxMDATxTimingSelected,
11630                tmnxMDASyncIfTimingStatus,
11631                tmnxMDANetworkIngQueues,
11632                tmnxMDACapabilities,
11633                tmnxMDAMinChannelization,
11634                tmnxMDAMaxChannelization,
11635                tmnxMDAMaxChannels,
11636                tmnxMDAChannelsInUse,
11637                tmnxMDACcagId,
11638                tmnxMdaTypeName,
11639                tmnxMdaTypeDescription,
11640                tmnxMdaTypeStatus,
11641                tmnxCcagRowStatus,
11642                tmnxCcagDescription,
11643                tmnxCcagAdminStatus,
11644                tmnxCcagOperStatus,
11645                tmnxCcagCcaRate,
11646                tmnxCcagLastChanged,
11647                tmnxCcagAccessAdaptQos,
11648                tmnxCcagPathLastChanged,
11649                tmnxCcagPathRate,
11650                tmnxCcagPathRateOption,
11651                tmnxCcagPathWeight,
11652                tmnxCcagPathCcLastChanged,
11653                tmnxCcagPathCcEgrPoolResvCbs,
11654                tmnxCcagPathCcEgrPoolSlpPlcy,
11655                tmnxCcagPathCcIngPoolResvCbs,
11656                tmnxCcagPathCcIngPoolSlpPlcy,
11657                tmnxCcagPathCcAcctPolicyId,
11658                tmnxCcagPathCcCollectStats,
11659                tmnxCcagPathCcQueuePlcy,
11660                tmnxCcagPathCcMac,
11661                tmnxCcagPathCcMtu,
11662                tmnxCcagPathCcHwMac,
11663                tmnxCcagPathCcUserAssignedMac
11664            }
11665    STATUS      obsolete
11666    DESCRIPTION
11667        "The group of objects supporting management of MDAs on
11668         Alcatel-Lucent SROS series systems."
11669
11670    ::= { tmnxChassisGroups 10 }
11671
11672tmnxChassisObsoleteGroup OBJECT-GROUP
11673    OBJECTS {   tmnxHwSwState,
11674                tmnxCardAllowedTypes,
11675                tmnxCpmCardAllowedTypes,
11676                tmnxMDAAllowedTypes
11677            }
11678    STATUS        current
11679    DESCRIPTION
11680        "The group of objects supporting the allowed types of CPM cards, IOM
11681         cards and MDA made obsolete for revision 3.0 on Alcatel-Lucent SROS
11682         series systems."
11683    ::= { tmnxChassisGroups 11 }
11684
11685tmnxCardV3v0Group   OBJECT-GROUP
11686    OBJECTS {   tmnxCardLastChange,
11687                tmnxCardTypeName,
11688                tmnxCardTypeDescription,
11689                tmnxCardTypeStatus,
11690                tmnxCardSupportedTypes,
11691                tmnxCardAssignedType,
11692                tmnxCardEquippedType,
11693                tmnxCardHwIndex,
11694                tmnxCardClockSource,
11695                tmnxCardNumMdaSlots,
11696                tmnxCardNumMdas,
11697                tmnxCardReboot,
11698                tmnxCardMemorySize,
11699                tmnxCpmCardLastChange,
11700                tmnxCpmCardSupportedTypes,
11701                tmnxCpmCardAssignedType,
11702                tmnxCpmCardEquippedType,
11703                tmnxCpmCardHwIndex,
11704                tmnxCpmCardBootOptionVersion,
11705                tmnxCpmCardBootOptionLastModified,
11706                tmnxCpmCardConfigBootedVersion,
11707                tmnxCpmCardIndexBootedVersion,
11708                tmnxCpmCardConfigLastModified,
11709                tmnxCpmCardConfigLastSaved,
11710                tmnxCpmCardRedundant,
11711                tmnxCpmCardClockSource,
11712                tmnxCpmCardNumCpus,
11713                tmnxCpmCardCpuType,
11714                tmnxCpmCardMemorySize,
11715                tmnxCpmCardSwitchToRedundantCard,
11716                tmnxCpmCardReboot,
11717                tmnxCpmCardRereadBootOptions,
11718                tmnxCpmCardConfigFileLastBooted,
11719                tmnxCpmCardConfigFileLastSaved,
11720                tmnxCpmCardConfigFileLastBootedHeader,
11721                tmnxCpmCardIndexFileLastBootedHeader,
11722                tmnxCpmCardBootOptionSource,
11723                tmnxCpmCardConfigSource,
11724                tmnxCpmCardBootOptionLastSaved,
11725                tmnxFabricLastChange,
11726                tmnxFabricAssignedType,
11727                tmnxFabricEquippedType,
11728                tmnxFabricHwIndex,
11729                tmnxCpmFlashOperStatus,
11730                tmnxCpmFlashSerialNumber,
11731                tmnxCpmFlashFirmwareRevision,
11732                tmnxCpmFlashModelNumber,
11733                tmnxCpmFlashCapacity,
11734                tmnxCpmFlashUsed,
11735                tmnxCpmFlashHwIndex,
11736                tmnxSyncIfTimingRevert,
11737                tmnxSyncIfTimingRefOrder1,
11738                tmnxSyncIfTimingRefOrder2,
11739                tmnxSyncIfTimingRef1SrcPort,
11740                tmnxSyncIfTimingRef1AdminStatus,
11741                tmnxSyncIfTimingRef1InUse,
11742                tmnxSyncIfTimingRef1Qualified,
11743                tmnxSyncIfTimingRef1Alarm,
11744                tmnxSyncIfTimingRef2SrcPort,
11745                tmnxSyncIfTimingRef2AdminStatus,
11746                tmnxSyncIfTimingRef2InUse,
11747                tmnxSyncIfTimingRef2Qualified,
11748                tmnxSyncIfTimingRef2Alarm,
11749                tmnxSyncIfTimingFreqOffset,
11750                tmnxSyncIfTimingStatus,
11751                tmnxSyncIfTimingRefOrder3,
11752                tmnxSyncIfTimingBITSIfType,
11753                tmnxSyncIfTimingBITSAdminStatus,
11754                tmnxSyncIfTimingBITSInUse,
11755                tmnxSyncIfTimingBITSQualified,
11756                tmnxSyncIfTimingBITSAlarm,
11757                tSyncIfTimingAdmRevert,
11758                tSyncIfTimingAdmRefOrder1,
11759                tSyncIfTimingAdmRefOrder2,
11760                tSyncIfTimingAdmRef1SrcPort,
11761                tSyncIfTimingAdmRef1AdminStatus,
11762                tSyncIfTimingAdmRef2SrcPort,
11763                tSyncIfTimingAdmRef2AdminStatus,
11764                tSyncIfTimingAdmChanged,
11765                tSyncIfTimingAdmRefOrder3,
11766                tSyncIfTimingAdmBITSIfType,
11767                tSyncIfTimingAdmBITSAdminStatus,
11768                tmnxChassisAdminOwner,
11769                tmnxChassisAdminControlApply,
11770                tmnxChassisAdminLastSetTimer,
11771                tmnxChassisAdminLastSetTimeout,
11772                tmnxSyncIfTimingBITS2InAdminStatus,
11773                tmnxSyncIfTimingBITS2OutAdminStatus
11774            }
11775    STATUS      current
11776    DESCRIPTION
11777        "The group of objects supporting management of hardware cards
11778         on Alcatel-Lucent SROS series systems."
11779    ::= { tmnxChassisGroups 12 }
11780
11781tmnxMDAV4v0Group        OBJECT-GROUP
11782    OBJECTS {   tmnxMDASupportedTypes,
11783                tmnxMDAAssignedType,
11784                tmnxMDAEquippedType,
11785                tmnxMDAHwIndex,
11786                tmnxMDAMaxPorts,
11787                tmnxMDAEquippedPorts,
11788                tmnxMDATxTimingSelected,
11789                tmnxMDASyncIfTimingStatus,
11790                tmnxMDANetworkIngQueues,
11791                tmnxMDACapabilities,
11792                tmnxMDAMinChannelization,
11793                tmnxMDAMaxChannelization,
11794                tmnxMDAMaxChannels,
11795                tmnxMDAChannelsInUse,
11796                tmnxMDACcagId,
11797                tmnxMdaTypeName,
11798                tmnxMdaTypeDescription,
11799                tmnxMdaTypeStatus,
11800                tmnxMDAReboot,
11801                tmnxCcagRowStatus,
11802                tmnxCcagDescription,
11803                tmnxCcagAdminStatus,
11804                tmnxCcagOperStatus,
11805                tmnxCcagCcaRate,
11806                tmnxCcagLastChanged,
11807                tmnxCcagAccessAdaptQos,
11808                tmnxCcagPathLastChanged,
11809                tmnxCcagPathRate,
11810                tmnxCcagPathRateOption,
11811                tmnxCcagPathWeight,
11812                tmnxCcagPathCcLastChanged,
11813                tmnxCcagPathCcEgrPoolResvCbs,
11814                tmnxCcagPathCcEgrPoolSlpPlcy,
11815                tmnxCcagPathCcIngPoolResvCbs,
11816                tmnxCcagPathCcIngPoolSlpPlcy,
11817                tmnxCcagPathCcAcctPolicyId,
11818                tmnxCcagPathCcCollectStats,
11819                tmnxCcagPathCcQueuePlcy,
11820                tmnxCcagPathCcMac,
11821                tmnxCcagPathCcMtu,
11822                tmnxCcagPathCcHwMac,
11823                tmnxCcagPathCcUserAssignedMac,
11824                tmnxMDAHiBwMcastSource,
11825                tmnxMDAHiBwMcastAlarm,
11826                tmnxMDAHiBwMcastTapCount,
11827                tmnxMDAHiBwMcastGroup
11828            }
11829    STATUS      obsolete
11830    DESCRIPTION
11831        "The group of objects supporting management of MDAs for release 4.0 on
11832         Alcatel-Lucent SROS series systems."
11833    ::= { tmnxChassisGroups 13 }
11834
11835tmnxChassisNotificationV4v0Group NOTIFICATION-GROUP
11836    NOTIFICATIONS   { tmnxEnvTempTooHigh,
11837                      tmnxEqPowerSupplyFailure,
11838                      tmnxEqPowerSupplyInserted,
11839                      tmnxEqPowerSupplyRemoved,
11840                      tmnxEqFanFailure,
11841                      tmnxEqCardFailure,
11842                      tmnxEqCardInserted,
11843                      tmnxEqCardRemoved,
11844                      tmnxEqWrongCard,
11845                      tmnxPeSoftwareVersionMismatch,
11846                      tmnxRedPrimaryCPMFail,
11847                      tmnxChassisNotificationClear,
11848                      tmnxEqSyncIfTimingHoldover,
11849                      tmnxEqSyncIfTimingHoldoverClear,
11850                      tmnxEqSyncIfTimingRef1Alarm,
11851                      tmnxEqSyncIfTimingRef1AlarmClear,
11852                      tmnxEqSyncIfTimingRef2Alarm,
11853                      tmnxEqSyncIfTimingRef2AlarmClear,
11854                      tmnxEqFlashDataLoss,
11855                      tmnxEqFlashDiskFull,
11856                      tmnxPeSoftwareLoadFailed,
11857                      tmnxPeBootloaderVersionMismatch,
11858                      tmnxPeBootromVersionMismatch,
11859                      tmnxPeFPGAVersionMismatch,
11860                      tmnxEqSyncIfTimingBITSAlarm,
11861                      tmnxEqSyncIfTimingBITSAlarmClear,
11862                      tmnxEqCardFirmwareUpgraded,
11863                      tmnxChassisUpgradeInProgress,
11864                      tmnxChassisUpgradeComplete,
11865                      tmnxChassisHiBwMcastAlarm,
11866                      tmnxEqMdaCfgNotCompatible
11867                    }
11868    STATUS        obsolete
11869    DESCRIPTION
11870        "The group of notifications supporting the management of chassis
11871         hardware for release 4.0 on Alcatel-Lucent SROS series systems."
11872    ::= { tmnxChassisGroups 14 }
11873
11874tmnx7710HwV3v0Group  OBJECT-GROUP
11875    OBJECTS {   tmnxChassisOverTempState,
11876                tmnxCpmCardMasterSlaveRefState,
11877                tmnxCcmOperStatus,
11878                tmnxCcmHwIndex,
11879                tmnxCcmEquippedType,
11880                tmnxCcmTypeName,
11881                tmnxCcmTypeDescription,
11882                tmnxCcmTypeStatus,
11883                tmnxMcmSupportedTypes,
11884                tmnxMcmAssignedType,
11885                tmnxMcmEquippedType,
11886                tmnxMcmHwIndex,
11887                tmnxMcmTypeName,
11888                tmnxMcmTypeDescription,
11889                tmnxMcmTypeStatus,
11890                tmnxChassisPowerSupplyInputStatus,
11891                tmnxChassisPowerSupplyOutputStatus,
11892                tmnxMDAReboot
11893    }
11894    STATUS      current
11895    DESCRIPTION
11896        "The group of objects supporting management of hardware specific to
11897         the Alcatel-Lucent 7710 SR series systems."
11898    ::= { tmnxChassisGroups 15 }
11899
11900tmnxChassisV5v0Group   OBJECT-GROUP
11901    OBJECTS {   tmnxChassisTotalNumber,
11902                tmnxChassisLastChange,
11903                tmnxChassisRowStatus,
11904                tmnxChassisName,
11905                tmnxChassisType,
11906                tmnxChassisLocation,
11907                tmnxChassisCoordinates,
11908                tmnxChassisNumSlots,
11909                tmnxChassisNumPorts,
11910                tmnxChassisNumPwrSupplies,
11911                tmnxChassisNumFanTrays,
11912                tmnxChassisNumFans,
11913                tmnxChassisCriticalLEDState,
11914                tmnxChassisMajorLEDState,
11915                tmnxChassisMinorLEDState,
11916                tmnxChassisBaseMacAddress,
11917                tmnxChassisCLLICode,
11918                tmnxChassisReboot,
11919                tmnxChassisUpgrade,
11920                tmnxChassisAdminMode,
11921                tmnxChassisOperMode,
11922                tmnxChassisModeForce,
11923                tmnxChassisUpdateTimeLeft,
11924                tmnxChassisFanOperStatus,
11925                tmnxChassisFanSpeed,
11926                tmnxChassisPowerSupplyACStatus,
11927                tmnxChassisPowerSupplyDCStatus,
11928                tmnxChassisPowerSupplyTempStatus,
11929                tmnxChassisPowerSupplyTempThreshold,
11930                tmnxChassisPowerSupply1Status,
11931                tmnxChassisPowerSupply2Status,
11932                tmnxChassisPowerSupplyAssignedType,
11933                tmnxChassisTypeName,
11934                tmnxChassisTypeDescription,
11935                tmnxChassisTypeStatus,
11936                tmnxHwLastChange,
11937                tmnxHwID,
11938                tmnxHwMfgString,
11939                tmnxHwMfgBoardNumber,
11940                tmnxHwSerialNumber,
11941                tmnxHwManufactureDate,
11942                tmnxHwClass,
11943                tmnxHwName,
11944                tmnxHwAlias,
11945                tmnxHwAssetID,
11946                tmnxHwCLEI,
11947                tmnxHwIsFRU,
11948                tmnxHwContainedIn,
11949                tmnxHwParentRelPos,
11950                tmnxHwAdminState,
11951                tmnxHwOperState,
11952                tmnxHwTempSensor,
11953                tmnxHwTemperature,
11954                tmnxHwTempThreshold,
11955                tmnxHwBootCodeVersion,
11956                tmnxHwSoftwareCodeVersion,
11957                tmnxHwSwLastBoot,
11958                tmnxHwAlarmState,
11959                tmnxHwLastAlarmEvent,
11960                tmnxHwClearAlarms,
11961                tmnxHwSwImageSource,
11962                tmnxHwMfgDeviations,
11963                tmnxHwBaseMacAddress,
11964                tmnxHwFailureReason,
11965                tmnxHwContainedIndex
11966            }
11967    STATUS        current
11968    DESCRIPTION
11969        "The group of objects supporting management of chassis hardware
11970         capabilities on release 5.0 of Alcatel-Lucent SROS series systems."
11971    ::= { tmnxChassisGroups 16 }
11972
11973tmnxChassisV5v0ObsoleteGroup   OBJECT-GROUP
11974    OBJECTS { tmnxChassisUpdateWaitTime
11975            }
11976    STATUS        current
11977    DESCRIPTION
11978        "The group of onbsolete objects for managing the chassis hardware
11979         capabilities on release 5.0 of Alcatel-Lucent SROS series systems."
11980    ::= { tmnxChassisGroups 17 }
11981
11982tmnx77x0CESMDAV6v0Group        OBJECT-GROUP
11983    OBJECTS {   tmnxMDAClockMode,
11984                tmnxMDADiffTimestampFreq,
11985                tmnxMDAIngNamedPoolPolicy,
11986                tmnxMDAEgrNamedPoolPolicy
11987            }
11988    STATUS      current
11989    DESCRIPTION
11990        "The group of objects supporting management of CES MDAs for release 6.0
11991         on Alcatel-Lucent 77x0 SR series systems."
11992    ::= { tmnxChassisGroups 18 }
11993
11994tmnxIPsecIsaGrpV6v0Group        OBJECT-GROUP
11995    OBJECTS {
11996                tmnxIPsecIsaGrpTableLastChanged,
11997                tmnxIPsecIsaGrpRowStatus,
11998                tmnxIPsecIsaGrpLastChanged,
11999                tmnxIPsecIsaGrpDescription,
12000                tmnxIPsecIsaGrpAdminState,
12001                tmnxIPsecIsaGrpOperState,
12002                tmnxIPsecIsaGrpIsaChassis,
12003                tmnxIPsecIsaGrpPrimaryIsa,
12004                tmnxIPsecIsaGrpBackupIsa,
12005                tmnxIPsecIsaGrpActiveIsa
12006            }
12007    STATUS      current
12008    DESCRIPTION
12009        "The group of objects supporting management of IPsec MDAs for
12010         release 6.0 on Alcatel-Lucent 7750 and 7710 SR series systems."
12011    ::= { tmnxChassisGroups 19 }
12012
12013tmnxChassisNotificationV3v0Group NOTIFICATION-GROUP
12014    NOTIFICATIONS   { tmnxEnvTempTooHigh,
12015                      tmnxEqPowerSupplyFailure,
12016                      tmnxEqPowerSupplyInserted,
12017                      tmnxEqPowerSupplyRemoved,
12018                      tmnxEqFanFailure,
12019                      tmnxEqCardFailure,
12020                      tmnxEqCardInserted,
12021                      tmnxEqCardRemoved,
12022                      tmnxEqWrongCard,
12023                      tmnxPeSoftwareVersionMismatch,
12024                      tmnxRedPrimaryCPMFail,
12025                      tmnxChassisNotificationClear,
12026                      tmnxEqSyncIfTimingHoldover,
12027                      tmnxEqSyncIfTimingHoldoverClear,
12028                      tmnxEqSyncIfTimingRef1Alarm,
12029                      tmnxEqSyncIfTimingRef1AlarmClear,
12030                      tmnxEqSyncIfTimingRef2Alarm,
12031                      tmnxEqSyncIfTimingRef2AlarmClear,
12032                      tmnxEqFlashDataLoss,
12033                      tmnxEqFlashDiskFull,
12034                      tmnxPeSoftwareLoadFailed,
12035                      tmnxPeBootloaderVersionMismatch,
12036                      tmnxPeBootromVersionMismatch,
12037                      tmnxPeFPGAVersionMismatch,
12038                      tmnxEqSyncIfTimingBITSAlarm,
12039                      tmnxEqSyncIfTimingBITSAlarmClear,
12040                      tmnxEqCardFirmwareUpgraded,
12041                      tmnxEqMdaCfgNotCompatible
12042                    }
12043    STATUS        obsolete
12044    DESCRIPTION
12045        "The group of notifications supporting the management of chassis
12046         hardware for release 3.0 on Alcatel-Lucent SROS series systems."
12047    ::= { tmnxChassisGroups 20 }
12048
12049tmnxChassisNotificationV6v0Group NOTIFICATION-GROUP
12050    NOTIFICATIONS   { tmnxEnvTempTooHigh,
12051                      tmnxEqPowerSupplyFailure,
12052                      tmnxEqPowerSupplyInserted,
12053                      tmnxEqPowerSupplyRemoved,
12054                      tmnxEqFanFailure,
12055                      tmnxEqCardFailure,
12056                      tmnxEqCardInserted,
12057                      tmnxEqCardRemoved,
12058                      tmnxEqWrongCard,
12059                      tmnxPeSoftwareVersionMismatch,
12060                      tmnxRedPrimaryCPMFail,
12061                      tmnxChassisNotificationClear,
12062                      tmnxEqSyncIfTimingHoldover,
12063                      tmnxEqSyncIfTimingHoldoverClear,
12064                      tmnxEqSyncIfTimingRef1Alarm,
12065                      tmnxEqSyncIfTimingRef1AlarmClear,
12066                      tmnxEqSyncIfTimingRef2Alarm,
12067                      tmnxEqSyncIfTimingRef2AlarmClear,
12068                      tmnxEqFlashDataLoss,
12069                      tmnxEqFlashDiskFull,
12070                      tmnxPeSoftwareLoadFailed,
12071                      tmnxPeBootloaderVersionMismatch,
12072                      tmnxPeBootromVersionMismatch,
12073                      tmnxPeFPGAVersionMismatch,
12074                      tmnxEqSyncIfTimingBITSAlarm,
12075                      tmnxEqSyncIfTimingBITSAlarmClear,
12076                      tmnxEqCardFirmwareUpgraded,
12077                      tmnxChassisUpgradeInProgress,
12078                      tmnxChassisUpgradeComplete,
12079                      tmnxChassisHiBwMcastAlarm,
12080                      tmnxEqMdaCfgNotCompatible,
12081                      tmnxCpmCardSyncFileNotPresent,
12082                      tmnxEqMdaXplError,
12083                      tmnxEqCardPChipError,
12084                      tmnxEqCardPChipMemoryEvent
12085                    }
12086    STATUS        obsolete
12087    DESCRIPTION
12088        "The group of notifications supporting the management of chassis
12089         hardware for release 6.0 on Alcatel-Lucent SROS series systems."
12090    ::= { tmnxChassisGroups 21 }
12091
12092tmnx7710SETSRefSrcHwV6v0Group  OBJECT-GROUP
12093    OBJECTS {
12094                tmnxSyncIfTimingRef1SrcHw,
12095                tmnxSyncIfTimingRef1BITSIfType,
12096                tmnxSyncIfTimingRef2SrcHw,
12097                tmnxSyncIfTimingRef2BITSIfType,
12098                tSyncIfTimingAdmRef1SrcHw,
12099                tSyncIfTimingAdmRef1BITSIfType,
12100                tSyncIfTimingAdmRef2SrcHw,
12101                tSyncIfTimingAdmRef2BITSIfType
12102            }
12103    STATUS      current
12104    DESCRIPTION
12105        "The group of objects supporting management of 'Synchronous Equipment
12106         Timing' (SETS) when the references are of type 'Building Integrated
12107         Timing Supply' (BITS) for release 6.0 on Alcatel-Lucent 7710 SR series
12108         systems."
12109    ::= { tmnxChassisGroups 22 }
12110
12111tmnxChassisHsmdaV6v0Group  OBJECT-GROUP
12112    OBJECTS {
12113                tmnxMDAIngHsmdaSchedPolicy,
12114                tmnxHsmdaMdaSchOvrTblLastChangd,
12115                tmnxHsmdaMdaSchOvrRowStatus,
12116                tmnxHsmdaMdaSchOvrLastChanged,
12117                tmnxHsmdaMdaSchOvrMaxRate,
12118                tmnxHsmdaMdaSchOvrGrp1Rate,
12119                tmnxHsmdaMdaSchOvrGrp2Rate,
12120                tmnxHsmdaMdaSchOvrClass1Rate,
12121                tmnxHsmdaMdaSchOvrClass1WtInGrp,
12122                tmnxHsmdaMdaSchOvrClass2Rate,
12123                tmnxHsmdaMdaSchOvrClass2WtInGrp,
12124                tmnxHsmdaMdaSchOvrClass3Rate,
12125                tmnxHsmdaMdaSchOvrClass3WtInGrp,
12126                tmnxHsmdaMdaSchOvrClass4Rate,
12127                tmnxHsmdaMdaSchOvrClass4WtInGrp,
12128                tmnxHsmdaMdaSchOvrClass5Rate,
12129                tmnxHsmdaMdaSchOvrClass5WtInGrp,
12130                tmnxHsmdaMdaSchOvrClass6Rate,
12131                tmnxHsmdaMdaSchOvrClass6WtInGrp,
12132                tmnxHsmdaMdaSchOvrClass7Rate,
12133                tmnxHsmdaMdaSchOvrClass7WtInGrp,
12134                tmnxHsmdaMdaSchOvrClass8Rate,
12135                tmnxHsmdaMdaSchOvrClass8WtInGrp,
12136                tmnxMDAIngHsmdaPoolPolicy,
12137                tmnxMDAEgrHsmdaPoolPolicy
12138            }
12139    STATUS      obsolete
12140    DESCRIPTION
12141        "The group of objects supporting management of the
12142         'Queueing MDA' (HSMDA) for release 6.0 on Alcatel-Lucent
12143         SROS series systems."
12144    ::= { tmnxChassisGroups 23 }
12145
12146tmnxMDAMcPathMgmtV6v0Group        OBJECT-GROUP
12147     OBJECTS {
12148                tmnxMDAMcPathMgmtBwPlcyName,
12149                tmnxMDAMcPathMgmtPriPathLimit,
12150                tmnxMDAMcPathMgmtSecPathLimit,
12151                tmnxMDAMcPathMgmtAncPathLimit,
12152                tmnxMDAMcPathMgmtAdminState,
12153                tmnxMDAMcPathMgmtPriInUseBw,
12154                tmnxMDAMcPathMgmtSecInUseBw,
12155                tmnxMDAMcPathMgmtAncInUseBw,
12156                tmnxMDAMcPathMgmtBlkHoleInUseBw
12157             }
12158     STATUS      current
12159     DESCRIPTION
12160         "The group of objects supporting management of Multicast Path
12161          Management feature for release 6.0 on Alcatel-Lucent SROS series
12162          systems."
12163     ::= { tmnxChassisGroups 24 }
12164
12165tmnxCardV6v0NamedPoolPlcyGroup   OBJECT-GROUP
12166    OBJECTS {
12167                tmnxCardNamedPoolAdminMode,
12168                tmnxCardNamedPoolOperMode
12169            }
12170    STATUS      current
12171    DESCRIPTION
12172        "The group of objects supporting named buffer pools for release
12173         6.0 on Alcatel-Lucent SROS series systems."
12174    ::= { tmnxChassisGroups 25 }
12175
12176tmnxChassisNotifyObjsV6v0Group   OBJECT-GROUP
12177    OBJECTS {   tmnxChassisNotifyCardName,
12178                tmnxChassisNotifyCardSyncFile
12179            }
12180    STATUS        current
12181    DESCRIPTION
12182        "The group of objects added in 6.0 release to support chassis
12183         hardware notifications on Alcatel-Lucent SROS series systems."
12184    ::= { tmnxChassisGroups 26 }
12185
12186tmnxChassisV6v1Group   OBJECT-GROUP
12187    OBJECTS {
12188                tmnxChassisPowerSupplyPemType,
12189                tmnxCardSoftReset,
12190                tmnxCardLastBootupReason
12191            }
12192    STATUS        current
12193    DESCRIPTION
12194        "The group of objects added in 6.1 release on Alcatel-Lucent 7xx0 SR
12195         series systems."
12196    ::= { tmnxChassisGroups 27 }
12197
12198tmnxFPMcPathMgmtV6v1Group        OBJECT-GROUP
12199     OBJECTS {
12200                tmnxFPMcPathMgmtBwPlcyName,
12201                tmnxFPMcPathMgmtAdminState,
12202                tmnxFPLastChanged,
12203                tmnxFPHiBwMcastSource,
12204                tmnxFPHiBwMcastAlarm,
12205                tmnxFPHiBwMcastTapCount,
12206                tmnxFPHiBwMcastGroup,
12207                tmnxFPHiBwMcastDefaultPathsOnly
12208             }
12209     STATUS      current
12210     DESCRIPTION
12211         "The group of objects supporting management of Multicast Path
12212          Management feature for release 6.1 on Alcatel-Lucent SROS series
12213          systems."
12214     ::= { tmnxChassisGroups 28 }
12215
12216tmnxMDAV6v1Group        OBJECT-GROUP
12217    OBJECTS {   tmnxMDASupportedTypes,
12218                tmnxMDAAssignedType,
12219                tmnxMDAEquippedType,
12220                tmnxMDAHwIndex,
12221                tmnxMDAMaxPorts,
12222                tmnxMDAEquippedPorts,
12223                tmnxMDATxTimingSelected,
12224                tmnxMDASyncIfTimingStatus,
12225                tmnxMDANetworkIngQueues,
12226                    tmnxMDACapabilities,
12227                    tmnxMDAMinChannelization,
12228                    tmnxMDAMaxChannelization,
12229                    tmnxMDAMaxChannels,
12230                    tmnxMDAChannelsInUse,
12231                    tmnxMdaTypeName,
12232                    tmnxMdaTypeDescription,
12233                    tmnxMdaTypeStatus,
12234                    tmnxMDAReboot,
12235                    tmnxMDAHiBwMcastSource,
12236                    tmnxMDAHiBwMcastAlarm,
12237                    tmnxMDAHiBwMcastTapCount,
12238                    tmnxMDAHiBwMcastGroup,
12239                    tmnxMDASynchronousEthernet
12240                }
12241        STATUS      current
12242        DESCRIPTION
12243            "The group of objects supporting management of MDAs for release 6.1 on
12244             Alcatel-Lucent SROS series systems."
12245        ::= { tmnxChassisGroups 29 }
12246
12247tmnxMDACcagV6v1Group        OBJECT-GROUP
12248        OBJECTS {   tmnxMDACcagId,
12249                    tmnxCcagRowStatus,
12250                    tmnxCcagDescription,
12251                    tmnxCcagAdminStatus,
12252                    tmnxCcagOperStatus,
12253                    tmnxCcagCcaRate,
12254                    tmnxCcagLastChanged,
12255                    tmnxCcagAccessAdaptQos,
12256                    tmnxCcagPathLastChanged,
12257                    tmnxCcagPathRate,
12258                    tmnxCcagPathRateOption,
12259                    tmnxCcagPathWeight,
12260                    tmnxCcagPathCcLastChanged,
12261                    tmnxCcagPathCcEgrPoolResvCbs,
12262                    tmnxCcagPathCcEgrPoolSlpPlcy,
12263                    tmnxCcagPathCcIngPoolResvCbs,
12264                    tmnxCcagPathCcIngPoolSlpPlcy,
12265                    tmnxCcagPathCcAcctPolicyId,
12266                    tmnxCcagPathCcCollectStats,
12267                    tmnxCcagPathCcQueuePlcy,
12268                    tmnxCcagPathCcMac,
12269                    tmnxCcagPathCcMtu,
12270                    tmnxCcagPathCcHwMac,
12271                    tmnxCcagPathCcUserAssignedMac
12272                }
12273        STATUS      current
12274        DESCRIPTION
12275            "The group of objects supporting management of MDA CCAG for release 6.1
12276             on Alcatel-Lucent SROS series systems."
12277        ::= { tmnxChassisGroups 30 }
12278
12279tmnxMdaXplV5v0Group              OBJECT-GROUP
12280        OBJECTS {   tmnxMDAXplErrorTime,
12281                    tmnxMDAXplFailedCount
12282                }
12283        STATUS      current
12284        DESCRIPTION
12285            "The group of objects added in 5.0 release to support MDA XPL
12286             error indications on Alcatel-Lucent SROS series systems."
12287        ::= { tmnxChassisGroups 31 }
12288
12289tmnxChassisNotifyObjsV5v0Group   OBJECT-GROUP
12290        OBJECTS {   tmnxCardComplexNumber,
12291                    tmnxCardFwdDirection
12292                }
12293        STATUS      current
12294        DESCRIPTION
12295            "The group of objects added in 5.0 release to support chassis
12296             hardware notifications on Alcatel-Lucent SROS series systems."
12297        ::= { tmnxChassisGroups 32 }
12298
12299tmnxChassisNotificationV5v0Group  NOTIFICATION-GROUP
12300        NOTIFICATIONS { tmnxEqMdaXplError,
12301                        tmnxEqCardPChipError,
12302                        tmnxEqCardPChipMemoryEvent
12303                      }
12304        STATUS       obsolete
12305        DESCRIPTION
12306            "The group of notifications added in 5.0 release to support the
12307             hardware notifications on Alcatel-Lucent SROS series systems."
12308        ::= { tmnxChassisGroups 33 }
12309
12310tmnxChassisNotificationV6v1Group NOTIFICATION-GROUP
12311        NOTIFICATIONS   { tmnxEnvTempTooHigh,
12312                          tmnxEqPowerSupplyFailure,
12313                          tmnxEqPowerSupplyInserted,
12314                          tmnxEqPowerSupplyRemoved,
12315                          tmnxEqFanFailure,
12316                          tmnxEqCardFailure,
12317                          tmnxEqCardInserted,
12318                          tmnxEqCardRemoved,
12319                          tmnxEqWrongCard,
12320                          tmnxPeSoftwareVersionMismatch,
12321                          tmnxRedPrimaryCPMFail,
12322                          tmnxChassisNotificationClear,
12323                          tmnxEqSyncIfTimingHoldover,
12324                          tmnxEqSyncIfTimingHoldoverClear,
12325                          tmnxEqSyncIfTimingRef1Alarm,
12326                          tmnxEqSyncIfTimingRef1AlarmClear,
12327                          tmnxEqSyncIfTimingRef2Alarm,
12328                          tmnxEqSyncIfTimingRef2AlarmClear,
12329                          tmnxEqFlashDataLoss,
12330                          tmnxEqFlashDiskFull,
12331                          tmnxPeSoftwareLoadFailed,
12332                          tmnxPeBootloaderVersionMismatch,
12333                          tmnxPeBootromVersionMismatch,
12334                          tmnxPeFPGAVersionMismatch,
12335                          tmnxEqSyncIfTimingBITSAlarm,
12336                          tmnxEqSyncIfTimingBITSAlarmClear,
12337                          tmnxEqCardFirmwareUpgraded,
12338                          tmnxChassisUpgradeInProgress,
12339                          tmnxChassisUpgradeComplete,
12340                          tmnxChassisHiBwMcastAlarm,
12341                          tmnxEqMdaCfgNotCompatible,
12342                          tmnxCpmCardSyncFileNotPresent,
12343                          tmnxEqMdaXplError,
12344                          tmnxEqCardPChipError,
12345                          tmnxEqCardSoftResetAlarm,
12346                          tmnxEqCardPChipMemoryEvent,
12347                          tmnxEqCardPChipCamEvent
12348                        }
12349        STATUS        obsolete
12350        DESCRIPTION
12351            "The group of notifications supporting the management of chassis
12352             hardware for release 6.0 on Alcatel-Lucent SROS series systems."
12353        ::= { tmnxChassisGroups 34 }
12354
12355tmnxChassisNotifyObjsV6v1Group   OBJECT-GROUP
12356        OBJECTS {   tmnxCardSoftResetState
12357                }
12358        STATUS      current
12359        DESCRIPTION
12360            "The group of objects added in 6.1 release to support chassis
12361             hardware notifications on Alcatel-Lucent SROS series systems."
12362        ::= { tmnxChassisGroups 35 }
12363
12364tmnxChassisNotificationV7v0Group NOTIFICATION-GROUP
12365        NOTIFICATIONS   { tmnxEnvTempTooHigh,
12366                          tmnxEqPowerSupplyFailure,
12367                          tmnxEqPowerSupplyInserted,
12368                          tmnxEqPowerSupplyRemoved,
12369                          tmnxEqFanFailure,
12370                          tmnxEqCardFailure,
12371                          tmnxEqCardInserted,
12372                          tmnxEqCardRemoved,
12373                          tmnxEqWrongCard,
12374                          tmnxPeSoftwareVersionMismatch,
12375                          tmnxRedPrimaryCPMFail,
12376                          tmnxChassisNotificationClear,
12377                          tmnxEqSyncIfTimingHoldover,
12378                          tmnxEqSyncIfTimingHoldoverClear,
12379                          tmnxEqSyncIfTimingRef1Alarm,
12380                          tmnxEqSyncIfTimingRef1AlarmClear,
12381                          tmnxEqSyncIfTimingRef2Alarm,
12382                          tmnxEqSyncIfTimingRef2AlarmClear,
12383                          tmnxEqFlashDataLoss,
12384                          tmnxEqFlashDiskFull,
12385                          tmnxPeSoftwareLoadFailed,
12386                          tmnxPeBootloaderVersionMismatch,
12387                          tmnxPeBootromVersionMismatch,
12388                          tmnxPeFPGAVersionMismatch,
12389                          tmnxEqSyncIfTimingBITSAlarm,
12390                          tmnxEqSyncIfTimingBITSAlarmClear,
12391                          tmnxEqCardFirmwareUpgraded,
12392                          tmnxChassisUpgradeInProgress,
12393                          tmnxChassisUpgradeComplete,
12394                          tmnxChassisHiBwMcastAlarm,
12395                          tmnxEqMdaCfgNotCompatible,
12396                          tmnxCpmCardSyncFileNotPresent,
12397                          tmnxEqMdaXplError,
12398                          tmnxEqCardPChipError,
12399                          tmnxEqCardSoftResetAlarm,
12400                          tmnxEqMdaSyncENotCompatible,
12401                          tmnxIPsecIsaGrpActiveIsaChgd,
12402                          tmnxEqCardPChipMemoryEvent,
12403                          tmnxIPsecIsaGrpUnableToSwitch,
12404                          tmnxEqCardPChipCamEvent,
12405                          tmnxEqHwEnhancedCapability
12406                    }
12407    STATUS        current
12408    DESCRIPTION
12409        "The group of notifications supporting the management of chassis
12410         hardware for release 7.0 on Alcatel-Lucent SROS series systems."
12411    ::= { tmnxChassisGroups 36 }
12412
12413tmnxChassisUserModV7v0Group   OBJECT-GROUP
12414    OBJECTS {         tmnxCpmCardConfigUserLastModified
12415            }
12416    STATUS        current
12417    DESCRIPTION
12418        "The group of objects added in 7.0 release on Alcatel-Lucent 7xx0
12419         SR series systems to track user modifications."
12420    ::= { tmnxChassisGroups 37 }
12421
12422tmnxCardPchipV5v0Group            OBJECT-GROUP
12423    OBJECTS {
12424               tmnxCardCmplx1IngrFcsOccur,
12425               tmnxCardCmplx1IngrFcsOccurTime,
12426               tmnxCardCmplx1EgrFcsOccur,
12427               tmnxCardCmplx1EgrFcsOccurTime,
12428               tmnxCardCmplx2IngrFcsOccur,
12429               tmnxCardCmplx2IngrFcsOccurTime,
12430               tmnxCardCmplx2EgrFcsOccur,
12431               tmnxCardCmplx2EgrFcsOccurTime,
12432               tmnxCardCmplx1MemParityOccur,
12433               tmnxCardCmplx1MemParityOccurTime,
12434               tmnxCardCmplx2MemParityOccur,
12435               tmnxCardCmplx2MemParityOccurTime
12436            }
12437    STATUS  current
12438    DESCRIPTION
12439        "The group of objects added in 5.0 release to support IOM Card
12440         Pchip error indications on Alcatel-Lucent SROS series systems."
12441    ::= { tmnxChassisGroups 38 }
12442
12443tmnxFPWredV7v0Group        OBJECT-GROUP
12444     OBJECTS {
12445               tmnxFPWredBufAllocMin,
12446               tmnxFPWredBufAllocMax,
12447               tmnxFPWredResvCbsMin,
12448               tmnxFPWredResvCbsMax,
12449               tmnxFPWredSlopePolicy,
12450               tmnxFPWredAdminState
12451             }
12452     STATUS      current
12453     DESCRIPTION
12454         "The group of objects supporting management of WRED Queue Management
12455         feature for release 7.0 on Alcatel-Lucent SROS series systems."
12456     ::= { tmnxChassisGroups 39 }
12457
12458tmnxChassisV7v0Group             OBJECT-GROUP
12459    OBJECTS {
12460              tmnxChassisFanRevision
12461            }
12462    STATUS      current
12463    DESCRIPTION
12464        "The group of objects added in 7.0 release on Alcatel-Lucent 7x50
12465         SR series systems to track Fan Tray revisions."
12466    ::= { tmnxChassisGroups 40 }
12467
12468tmnxIPsecV7v0Group             OBJECT-GROUP
12469    OBJECTS {
12470              tmnxIPsecIsaGrpTunnels,
12471              tmnxIPsecIsaGrpMaxTunnels
12472            }
12473    STATUS      current
12474    DESCRIPTION
12475        "The group of objects added in 7.0 release on Alcatel-Lucent 7x50
12476         SR series systems related to IPsec feature."
12477    ::= { tmnxChassisGroups 41 }
12478
12479tmnxIPsecNotifV7v0Group   NOTIFICATION-GROUP
12480    NOTIFICATIONS {
12481               tmnxIPsecIsaGrpTnlLowWMark,
12482               tmnxIPsecIsaGrpTnlHighWMark,
12483               tmnxIPsecIsaGrpTnlMax
12484            }
12485    STATUS      current
12486    DESCRIPTION
12487        "The group of objects added in 7.0 release to support IPsec
12488         notifications on Alcatel-Lucent SROS series systems."
12489    ::= { tmnxChassisGroups 42 }
12490
12491tmnxSyncV6v0Group              OBJECT-GROUP
12492    OBJECTS {
12493                tmnxSyncIfTimingRef1State,
12494                tmnxSyncIfTimingRef2State,
12495                tmnxSyncIfTimingBITSState
12496            }
12497    STATUS      current
12498    DESCRIPTION
12499        "The group of objects added in 6.0 release on Alcatel 7xx0
12500         SR series systems related to system timing."
12501    ::= { tmnxChassisGroups 43 }
12502
12503tmnxSyncIfTimingV8v0Group        OBJECT-GROUP
12504    OBJECTS {
12505               tmnxSyncIfTimingBITSOutAdmStatus,
12506               tmnxSyncIfTimingBITSOutLineLen,
12507               tmnxSyncIfTimingRef1CfgQltyLevel,
12508               tmnxSyncIfTimingRef1RxQltyLevel,
12509               tmnxSyncIfTimingRef2CfgQltyLevel,
12510               tmnxSyncIfTimingRef2RxQltyLevel,
12511               tmnxSyncIfTimingBITSCfgQltyLevel,
12512               tmnxSyncIfTimingBITSRxQltyLevel,
12513               tmnxSyncIfTimingBITS2InUse,
12514               tmnxSyncIfTimingBITS2Qualified,
12515               tmnxSyncIfTimingBITS2Alarm,
12516               tmnxSyncIfTimingBITS2RxQltyLevel,
12517               tmnxSyncIfTimingBITS2State,
12518               tmnxSyncIfTimingRef1NationalUse,
12519               tmnxSyncIfTimingRef2NationalUse,
12520               tmnxSyncIfTimingBITSNationalUse,
12521               tmnxSyncIfTimingQLSelection,
12522               tmnxSyncIfTimingOtherCPMInUse,
12523               tmnxSyncIfTimingOtherCPMQual,
12524               tmnxSyncIfTimingOtherCPMAlarm,
12525               tmnxSyncIfTimingOtherCPMState,
12526               tmnxSyncIfTimingBITSOutRefSel,
12527               tmnxSyncIfTimingBITSTxQltyLevel,
12528               tmnxSyncIfTimingBITS2AdminStatus,
12529               tmnxSyncIfTimingSystemQltyLevel,
12530               tSyncIfTimingAdmBITSOutAdmStatus,
12531               tSyncIfTimingAdmBITSOutLineLen,
12532               tSyncIfTimingAdmRef1CfgQltyLevel,
12533               tSyncIfTimingAdmRef2CfgQltyLevel,
12534               tSyncIfTimingAdmBITSCfgQltyLevel,
12535               tSyncIfTimingAdmRef1NationalUse,
12536               tSyncIfTimingAdmRef2NationalUse,
12537               tSyncIfTimingAdmBITSNationalUse,
12538               tSyncIfTimingAdmQLSelection
12539            }
12540    STATUS      current
12541    DESCRIPTION
12542        "The group of objects added in 8.0 release to support new
12543         Sync-if-timing features on Alcatel SROS series systems."
12544    ::= { tmnxChassisGroups 44 }
12545
12546tmnxSyncIfTimingNotifV8v0Group   NOTIFICATION-GROUP
12547    NOTIFICATIONS {
12548               tmnxEqSyncIfTimingRef1Quality,
12549               tmnxEqSyncIfTimingRef2Quality,
12550               tmnxEqSyncIfTimingBITSQuality,
12551               tmnxEqSyncIfTimingBITS2Quality,
12552               tmnxEqSyncIfTimingRefSwitch,
12553               tmnxEqSyncIfTimingBITS2Alarm,
12554               tmnxEqSyncIfTimingBITS2AlarmClr,
12555               tmnxEqSyncIfTimingBITSOutRefChg,
12556               tmnxEqSyncIfTimingSystemQuality
12557            }
12558    STATUS      current
12559    DESCRIPTION
12560        "The group of objects added in 8.0 release to support Sync-If-Timing
12561         notifications on Alcatel-Lucent SROS series systems."
12562    ::= { tmnxChassisGroups 45 }
12563
12564
12565tmnxChassisV8v0Group             OBJECT-GROUP
12566    OBJECTS {
12567              tmnxHwEquippedPlatform,
12568              tmnxChassisRedForcedSingleSfm,
12569              tmnxCardCapability
12570            }
12571    STATUS      current
12572    DESCRIPTION
12573        "The group of objects added in 8.0 release on Alcatel-Lucent
12574         SR series systems."
12575    ::= { tmnxChassisGroups 46 }
12576
12577tmnxChassisMixedModeIomV8v0Group             OBJECT-GROUP
12578    OBJECTS {
12579              tmnxChassisMixedModeIomAdminMode,
12580              tmnxChassisMixedModeIomUpgrList
12581            }
12582    STATUS      current
12583    DESCRIPTION
12584        "The group of objects added in 8.0 release on Alcatel-Lucent
12585         SR series systems to support the Mixed Mode IOM feature."
12586    ::= { tmnxChassisGroups 47 }
12587
12588tmnxCardCamErrorV6v1Group        OBJECT-GROUP
12589    OBJECTS {
12590               tmnxCardCmplx1CAMErrorOccur,
12591               tmnxCardCmplx1CAMErrorOccurTime,
12592               tmnxCardCmplx2CAMErrorOccur,
12593               tmnxCardCmplx2CAMErrorOccurTime,
12594               tmnxCpmCardCmplxCAMErrOccur,
12595               tmnxCpmCardCmplxCAMErrOccurTime
12596            }
12597    STATUS      current
12598    DESCRIPTION
12599        "The group of objects added in 6.1 release on Alcatel 7xx0
12600         SR series systems related to Card CAM Failures."
12601    ::= { tmnxChassisGroups 48 }
12602
12603tmnxChassisV6v0Group             OBJECT-GROUP
12604    OBJECTS {
12605                tmnxCardLastBootupReason
12606            }
12607    STATUS      obsolete
12608    DESCRIPTION
12609        "The group of objects added in 6.0 release on Alcatel 7xx0
12610         SR series systems."
12611    ::= { tmnxChassisGroups 49 }
12612
12613tmnxCardV7v0Group                OBJECT-GROUP
12614    OBJECTS {
12615                tmnxCardFailOnError
12616            }
12617    STATUS      current
12618    DESCRIPTION
12619        "The group of objects added in 7.0 release on Alcatel 7xx0 SR
12620         series systems for card management."
12621    ::= { tmnxChassisGroups 50 }
12622
12623tmnxAtmGroup                OBJECT-GROUP
12624    OBJECTS {
12625             tmnxMDAAtmMode
12626            }
12627    STATUS      current
12628    DESCRIPTION
12629        "The group of objects on Alcatel 7xx0 SR
12630         series systems for ATM management."
12631    ::= { tmnxChassisGroups 51 }
12632
12633tmnxChassisHwV6v1Group           OBJECT-GROUP
12634    OBJECTS {
12635             tmnxHwMfgAssemblyNumber
12636            }
12637    STATUS      current
12638    DESCRIPTION
12639        "The group of hardware related objects added in release 6.1 on Alcatel
12640         7xx0 SR series systems."
12641    ::= { tmnxChassisGroups 52 }
12642
12643tmnxChassisHwV9v0Group           OBJECT-GROUP
12644    OBJECTS {
12645                tmnxCpmCardOscillatorType,
12646                tmnxHwFirmwareCodeVersion
12647            }
12648    STATUS      current
12649    DESCRIPTION
12650        "The group of hardware related objects added in release 9.0 on Alcatel
12651         SROS series systems."
12652    ::= { tmnxChassisGroups 53 }
12653
12654tmnxSyncIfTimingV9v0Group        OBJECT-GROUP
12655    OBJECTS {
12656               tmnxSyncIfTimingRefOrder4,
12657               tmnxSyncIfTimingPTPAdminStatus,
12658               tmnxSyncIfTimingPTPInUse,
12659               tmnxSyncIfTimingPTPQualified,
12660               tmnxSyncIfTimingPTPAlarm,
12661               tmnxSyncIfTimingPTPCfgQltyLevel,
12662               tmnxSyncIfTimingPTPRxQltyLevel,
12663               tmnxSyncIfTimingPTPState,
12664               tmnxSyncIfTimingBITSOutSource,
12665               tSyncIfTimingAdmRefOrder4,
12666               tSyncIfTimingAdmPTPAdminStatus,
12667               tSyncIfTimingAdmPTPCfgQltyLevel,
12668               tSyncIfTimingAdmBITSOutSource,
12669               tmnxSyncIfTimingRefOrder5,
12670               tSyncIfTimingAdmRefOrder5
12671            }
12672    STATUS      current
12673    DESCRIPTION
12674        "The group of objects added in 9.0 release to support new
12675         Sync-if-timing features on Alcatel SROS series systems."
12676    ::= { tmnxChassisGroups 54 }
12677
12678tmnxSyncIfTimingNotifyV9v0Group  NOTIFICATION-GROUP
12679    NOTIFICATIONS {
12680               tmnxEqSyncIfTimingPTPQuality,
12681               tmnxEqSyncIfTimingPTPAlarm,
12682               tmnxEqSyncIfTimingPTPAlarmClear
12683            }
12684    STATUS      current
12685    DESCRIPTION
12686        "The group of notifications added in 9.0 release to support new
12687         Sync-if-timing features on Alcatel SROS series systems."
12688    ::= { tmnxChassisGroups 55 }
12689
12690tmnxChassisNotifyObjsV9v0Group   OBJECT-GROUP
12691    OBJECTS {
12692               tmnxMdaNotifyType
12693            }
12694    STATUS      current
12695    DESCRIPTION
12696        "The group of notification objects extending chassis features for
12697         revision 9.0 on Alcatel SROS series systems."
12698    ::= { tmnxChassisGroups 56 }
12699
12700tmnxMDAV9v0Group   OBJECT-GROUP
12701    OBJECTS {
12702               tmnxMDAEgrHsmdaThrshLoBrstMult,
12703               tmnxMDAEgrHsmdaThrshHiBrstInc
12704            }
12705    STATUS      current
12706    DESCRIPTION
12707        "The group of objects added in 9.0 release to support new
12708         HSMDA threshold limits on Alcatel SROS series systems."
12709    ::= { tmnxChassisGroups 57 }
12710
12711tmnxCardPchipV8v0Group            OBJECT-GROUP
12712    OBJECTS {
12713               tmnxCardCmplx1EgrFcsSrcSlots,
12714               tmnxCardCmplx2EgrFcsSrcSlots
12715            }
12716    STATUS      current
12717    DESCRIPTION
12718        "The group of objects added in 8.0 release to enhance IOM Card
12719         Pchip error indications on Alcatel-Lucent SROS series systems."
12720    ::= { tmnxChassisGroups 58 }
12721
12722tmnxChassisNotifyObjsV8v0Group   OBJECT-GROUP
12723    OBJECTS {   tmnxCardSrcSlotBitmap
12724            }
12725    STATUS      current
12726    DESCRIPTION
12727        "The group of objects added in 8.0 release to support chassis
12728         hardware notifications on Alcatel-Lucent SROS series systems."
12729    ::= { tmnxChassisGroups 59 }
12730
12731tmnxFPQGrpGroup   OBJECT-GROUP
12732    OBJECTS {
12733       tmnxFPAccIngQGrpAcctgPolId,
12734       tmnxFPAccIngQGrpCollectStats,
12735       tmnxFPAccIngQGrpDescr,
12736       tmnxFPAccIngQGrpLastChgd,
12737       tmnxFPAccIngQGrpRowStatus,
12738       tmnxFPAccIngQGrpPolicerPol,
12739       tmnxFPAccIngQGrpTableLastChgd,
12740       tmnxFPNetIngQGrpAcctgPolId,
12741       tmnxFPNetIngQGrpCollectStats,
12742       tmnxFPNetIngQGrpDescr,
12743       tmnxFPNetIngQGrpLastChgd,
12744       tmnxFPNetIngQGrpRowStatus,
12745       tmnxFPNetIngQGrpPolicerPol,
12746       tmnxFPNetIngQGrpTableLastChgd,
12747       tmnxFPNetIngQGrpPStatMode,
12748       tmnxFPNetIngQgPStOffHPrioPkts,
12749       tmnxFPNetIngQgPStOffHPrioPktsL,
12750       tmnxFPNetIngQgPStOffHPrioPktsH,
12751       tmnxFPNetIngQgPStDrpHPrioPkts,
12752       tmnxFPNetIngQgPStDrpHPrioPktsL,
12753       tmnxFPNetIngQgPStDrpHPrioPktsH,
12754       tmnxFPNetIngQgPStOffLPrioPkts,
12755       tmnxFPNetIngQgPStOffLPrioPktsL,
12756       tmnxFPNetIngQgPStOffLPrioPktsH,
12757       tmnxFPNetIngQgPStDrpLPrioPkts,
12758       tmnxFPNetIngQgPStDrpLPrioPktsL,
12759       tmnxFPNetIngQgPStDrpLPrioPktsH,
12760       tmnxFPNetIngQgPStOffHPrioOcts,
12761       tmnxFPNetIngQgPStOffHPrioOctsL,
12762       tmnxFPNetIngQgPStOffHPrioOctsH,
12763       tmnxFPNetIngQgPStDrpHPrioOcts,
12764       tmnxFPNetIngQgPStDrpHPrioOctsL,
12765       tmnxFPNetIngQgPStDrpHPrioOctsH,
12766       tmnxFPNetIngQgPStOffLPrioOcts,
12767       tmnxFPNetIngQgPStOffLPrioOctsL,
12768       tmnxFPNetIngQgPStOffLPrioOctsH,
12769       tmnxFPNetIngQgPStDrpLPrioOcts,
12770       tmnxFPNetIngQgPStDrpLPrioOctsL,
12771       tmnxFPNetIngQgPStDrpLPrioOctsH,
12772       tmnxFPNetIngQgPStFwdInProfPkts,
12773       tmnxFPNetIngQgPStFwdInProfPktsL,
12774       tmnxFPNetIngQgPStFwdInProfPktsH,
12775       tmnxFPNetIngQgPStFwdOutProfPkts,
12776       tmnxFPNetIngQgPStFwdOutProfPktsL,
12777       tmnxFPNetIngQgPStFwdOutProfPktsH,
12778       tmnxFPNetIngQgPStFwdInProfOcts,
12779       tmnxFPNetIngQgPStFwdInProfOctsL,
12780       tmnxFPNetIngQgPStFwdInProfOctsH,
12781       tmnxFPNetIngQgPStFwdOutProfOcts,
12782       tmnxFPNetIngQgPStFwdOutProfOctsL,
12783       tmnxFPNetIngQgPStFwdOutProfOctsH,
12784       tmnxFPNetIngQgPStUncolPktsOff,
12785       tmnxFPNetIngQgPStUncolPktsOffL,
12786       tmnxFPNetIngQgPStUncolPktsOffH,
12787       tmnxFPNetIngQgPStUncolOctsOff,
12788       tmnxFPNetIngQgPStUncolOctsOffL,
12789       tmnxFPNetIngQgPStUncolOctsOffH,
12790       tmnxFPAccIngQGrpPStatMode,
12791       tmnxFPAccIngQgPStOffHPrioPkts,
12792       tmnxFPAccIngQgPStOffHPrioPktsL,
12793       tmnxFPAccIngQgPStOffHPrioPktsH,
12794       tmnxFPAccIngQgPStDrpHPrioPkts,
12795       tmnxFPAccIngQgPStDrpHPrioPktsL,
12796       tmnxFPAccIngQgPStDrpHPrioPktsH,
12797       tmnxFPAccIngQgPStOffLPrioPkts,
12798       tmnxFPAccIngQgPStOffLPrioPktsL,
12799       tmnxFPAccIngQgPStOffLPrioPktsH,
12800       tmnxFPAccIngQgPStDrpLPrioPkts,
12801       tmnxFPAccIngQgPStDrpLPrioPktsL,
12802       tmnxFPAccIngQgPStDrpLPrioPktsH,
12803       tmnxFPAccIngQgPStOffHPrioOcts,
12804       tmnxFPAccIngQgPStOffHPrioOctsL,
12805       tmnxFPAccIngQgPStOffHPrioOctsH,
12806       tmnxFPAccIngQgPStDrpHPrioOcts,
12807       tmnxFPAccIngQgPStDrpHPrioOctsL,
12808       tmnxFPAccIngQgPStDrpHPrioOctsH,
12809       tmnxFPAccIngQgPStOffLPrioOcts,
12810       tmnxFPAccIngQgPStOffLPrioOctsL,
12811       tmnxFPAccIngQgPStOffLPrioOctsH,
12812       tmnxFPAccIngQgPStDrpLPrioOcts,
12813       tmnxFPAccIngQgPStDrpLPrioOctsL,
12814       tmnxFPAccIngQgPStDrpLPrioOctsH,
12815       tmnxFPAccIngQgPStFwdInProfPkts,
12816       tmnxFPAccIngQgPStFwdInProfPktsL,
12817       tmnxFPAccIngQgPStFwdInProfPktsH,
12818       tmnxFPAccIngQgPStFwdOutProfPkts,
12819       tmnxFPAccIngQgPStFwdOutProfPktsL,
12820       tmnxFPAccIngQgPStFwdOutProfPktsH,
12821       tmnxFPAccIngQgPStFwdInProfOcts,
12822       tmnxFPAccIngQgPStFwdInProfOctsL,
12823       tmnxFPAccIngQgPStFwdInProfOctsH,
12824       tmnxFPAccIngQgPStFwdOutProfOcts,
12825       tmnxFPAccIngQgPStFwdOutProfOctsL,
12826       tmnxFPAccIngQgPStFwdOutProfOctsH,
12827       tmnxFPAccIngQgPStUncolPktsOff,
12828       tmnxFPAccIngQgPStUncolPktsOffL,
12829       tmnxFPAccIngQgPStUncolPktsOffH,
12830       tmnxFPAccIngQgPStUncolOctsOff,
12831       tmnxFPAccIngQgPStUncolOctsOffL,
12832       tmnxFPAccIngQgPStUncolOctsOffH,
12833       tFPNetIngQGrpArbitStatFwdPkts,
12834       tFPNetIngQGrpArbitStatFwdPktsL,
12835       tFPNetIngQGrpArbitStatFwdPktsH,
12836       tFPNetIngQGrpArbitStatFwdOcts,
12837       tFPNetIngQGrpArbitStatFwdOctsL,
12838       tFPNetIngQGrpArbitStatFwdOctsH,
12839       tFPAccIngQGrpArbitStatFwdPkts,
12840       tFPAccIngQGrpArbitStatFwdPktsL,
12841       tFPAccIngQGrpArbitStatFwdPktsH,
12842       tFPAccIngQGrpArbitStatFwdOcts,
12843       tFPAccIngQGrpArbitStatFwdOctsL,
12844       tFPAccIngQGrpArbitStatFwdOctsH
12845    }
12846    STATUS      current
12847    DESCRIPTION
12848        "The group of objects added in 10.0 release to support fowarding-plane
12849         queue-group objects on Alcatel-Lucent SROS series systems."
12850    ::= { tmnxChassisGroups 60 }
12851
12852tmnxCardV10v0Group            OBJECT-GROUP
12853    OBJECTS {
12854               tmnxCardHardResetUnsupMdas,
12855               tmnxCardRateCalcFastQueue,
12856               tmnxCardRateCalcSlowQueue,
12857               tmnxCardSchedRun,
12858               tmnxCardTaskScheduling,
12859               tmnxCardSlowQueueThresh
12860    }
12861    STATUS      current
12862    DESCRIPTION
12863        "The group of objects added in 10.0 release to enhance IOM Card
12864         features on Alcatel-Lucent SROS series systems."
12865    ::= { tmnxChassisGroups 61 }
12866
12867tmnxIpsecV10v0Group            OBJECT-GROUP
12868    OBJECTS {
12869       tmnxIPsecIsaGrpTunnelReassembly,
12870       tmnxIPsecIsaGrpOperFlags,
12871       tmnxIPsecIsaGrpIpTunnels,
12872       tmnxIPsecIsaGrpIpMaxTunnels
12873    }
12874    STATUS      current
12875    DESCRIPTION
12876        "The group of objects added in 10.0 release to ipsec
12877         features on Alcatel-Lucent SROS series systems."
12878    ::= { tmnxChassisGroups 62 }
12879
12880tmnxChassisV10v0Group            OBJECT-GROUP
12881    OBJECTS {
12882        tmnxFanTrayCompSpeed,
12883        tmnxFabricSupportedTypes,
12884        tmnxFabricReboot,
12885        tmnxFabricTypeName,
12886        tmnxFabricTypeDescription,
12887        tmnxFabricTypeStatus,
12888        tmnxHwResourceCurrentVoltage,
12889        tmnxHwResourcePeakVoltage,
12890        tmnxHwResourcePeakVoltageTime,
12891        tmnxHwResourceMinVoltage,
12892        tmnxHwResourceMinVoltageTime,
12893        tmnxHwResourceCurrentWattage,
12894        tmnxHwResourcePeakWattage,
12895        tmnxHwResourcePeakWattageTime,
12896        tmnxHwResourceMinWattage,
12897        tmnxHwResourceMinWattageTime,
12898        tmnxHwResourceCurrentAmperage,
12899        tmnxHwResourcePeakAmperage,
12900        tmnxHwResourcePeakAmperageTime,
12901        tmnxHwResourceMinAmperage,
12902        tmnxHwResourceMinAmperageTime
12903    }
12904    STATUS      current
12905    DESCRIPTION
12906        "The group of objects added in 10.0 release to enhance hardware
12907        functionality on Alcatel-Lucent SROS series systems."
12908    ::= { tmnxChassisGroups 63 }
12909
12910tmnxChassisNotificationV9v0Group NOTIFICATION-GROUP
12911    NOTIFICATIONS {
12912                      tmnxPeFirmwareVersionWarning
12913                  }
12914    STATUS        current
12915    DESCRIPTION
12916        "The group of notifications supporting the management of chassis
12917         hardware for release 9.0 on Alcatel-Lucent SROS series systems."
12918    ::= { tmnxChassisGroups 64 }
12919
12920tmnxFPQGrpV10v0R4Group   OBJECT-GROUP
12921    OBJECTS {
12922        tFPAccIngQGrpPlcrOvrTblLstChgd,
12923        tFPAccIngQGrpPlcrOvrRowStatus,
12924        tFPAccIngQGrpPlcrOvrLastChgd,
12925        tFPAccIngQGrpPlcrOvrAdminPIR,
12926        tFPAccIngQGrpPlcrOvrAdminCIR,
12927        tFPAccIngQGrpPlcrOvrStatMode,
12928        tFPAccIngQGrpPlcrOvrMBS,
12929        tFPAccIngQGrpPlcrOvrCBS,
12930        tFPAccIngQGrpPlcrOvrPktOffset
12931    }
12932    STATUS      current
12933    DESCRIPTION
12934        "The group of objects added in 10.0 release to support fowarding-plane
12935         queue-group policer override objects on Alcatel-Lucent SROS series
12936         systems."
12937    ::= { tmnxChassisGroups 65 }
12938
12939tmnxMdaV10v0Group            OBJECT-GROUP
12940    OBJECTS {
12941        tmnxMDAIsaTunnelGroup,
12942        tmnxIPsecIsaGrpMultiActive,
12943        tmnxIPsecIsaGrpActiveMda,
12944        tmnxMDAIsaTunnelGroupInUse
12945    }
12946    STATUS      current
12947    DESCRIPTION
12948        "The group of objects added in 10.0 release to enhance IOM MDA
12949         features on Alcatel-Lucent SROS series systems."
12950    ::= { tmnxChassisGroups 66 }
12951
12952tmnxMdaObsoletedV10v0Group OBJECT-GROUP
12953    OBJECTS {
12954        tmnxMDAIngHsmdaSchedPolicy,
12955        tmnxMDAIngHsmdaPoolPolicy,
12956        tmnxHsmdaMdaSchOvrTblLastChangd,
12957        tmnxHsmdaMdaSchOvrRowStatus,
12958        tmnxHsmdaMdaSchOvrLastChanged,
12959        tmnxHsmdaMdaSchOvrMaxRate,
12960        tmnxHsmdaMdaSchOvrGrp1Rate,
12961        tmnxHsmdaMdaSchOvrGrp2Rate,
12962        tmnxHsmdaMdaSchOvrClass1Rate,
12963        tmnxHsmdaMdaSchOvrClass1WtInGrp,
12964        tmnxHsmdaMdaSchOvrClass2Rate,
12965        tmnxHsmdaMdaSchOvrClass2WtInGrp,
12966        tmnxHsmdaMdaSchOvrClass3Rate,
12967        tmnxHsmdaMdaSchOvrClass3WtInGrp,
12968        tmnxHsmdaMdaSchOvrClass4Rate,
12969        tmnxHsmdaMdaSchOvrClass4WtInGrp,
12970        tmnxHsmdaMdaSchOvrClass5Rate,
12971        tmnxHsmdaMdaSchOvrClass5WtInGrp,
12972        tmnxHsmdaMdaSchOvrClass6Rate,
12973        tmnxHsmdaMdaSchOvrClass6WtInGrp,
12974        tmnxHsmdaMdaSchOvrClass7Rate,
12975        tmnxHsmdaMdaSchOvrClass7WtInGrp,
12976        tmnxHsmdaMdaSchOvrClass8Rate,
12977        tmnxHsmdaMdaSchOvrClass8WtInGrp
12978   }
12979    STATUS      current
12980    DESCRIPTION
12981        "The group of objects obsoleted in 10.0 release to enhance IOM MDA
12982         features on Alcatel-Lucent SROS series systems."
12983    ::= { tmnxChassisGroups 67 }
12984
12985tmnxChassisNotifyV10v0Group NOTIFICATION-GROUP
12986    NOTIFICATIONS {
12987         tmnxMDAIsaTunnelGroupChange
12988    }
12989    STATUS        current
12990    DESCRIPTION
12991        "The group of notifications supporting the management of chassis
12992         hardware for release 10.0 on Alcatel-Lucent SROS series systems."
12993    ::= { tmnxChassisGroups 69 }
12994
12995tmnxMdaHsmdaPoolV10v0Group    OBJECT-GROUP
12996    OBJECTS {
12997         tmnxMDAEgrHsmdaPoolPolicy
12998    }
12999    STATUS      current
13000    DESCRIPTION
13001        "The group of objects added in 10.0 release to enhance IOM MDA
13002         features related to HSMDA on Alcatel-Lucent SROS series systems."
13003    ::= { tmnxChassisGroups 70 }
13004
13005END
13006