1Found UPS at /dev/usb/hid/hiddev0 2hiddev driver version is 1.0.2 3HID: vendor 0x51d product 0x2 version 0x100 app UPS 4HID: bus: 1 devnum: 3 ifnum: 0 5UPS HID device name: "American Power Conversion Back-UPS 350 FW: 5.2.I USB FW: c1 " 6Battery Chemistry: "PbAc" (4) 7 8InputReport 6 9 Field 0, app UPS, phys PowerSummary 10 Usage 0, Charging = 0 11 Field 1, app UPS, phys PowerSummary 12 Usage 0, Discharging = 0 13 Field 2, app UPS, phys PowerSummary 14 Usage 0, APCStatusFlag = 8 0x8 15 16InputReport 12 17 Field 0, app UPS, phys PowerSummary 18Exponent 0 lost. 19 Usage 0, RemainingCapacity = 100 percent 20 Field 1, app UPS, phys PowerSummary 21 Usage 0, RunTimeToEmpty = 1380 Seconds 22 23InputReport 19 24 Field 0, app UPS, phys PowerSummary 25 Usage 0, ACPresent = 1 26 27InputReport 20 28 Field 0, app UPS, phys PowerSummary 29 Usage 0, BelowRemainingCapacityLimit = 0 30 Field 1, app UPS, phys PowerSummary 31 Usage 0, ShutdownImminent = 0 32 33FeatureReport 1 34 Field 0, app UPS, phys PowerSummary 35 Usage 0, iProduct = 1 Back-UPS 350 FW: 5.2.I USB FW: c1 36 37FeatureReport 2 38 Field 0, app UPS, phys PowerSummary 39 Usage 0, iSerialNumber = 2 BB0115017954 40 41FeatureReport 3 42 Field 0, app UPS, phys PowerSummary 43 Usage 0, iDeviceChemistry = 4 PbAc 44 45FeatureReport 4 46 Field 0, app UPS, phys PowerSummary 47 Usage 0, iOEMInformation = 3 American Power Conversion 48 49FeatureReport 5 50 Field 0, app UPS, phys PowerSummary 51 Usage 0, Rechargeable = 1 52 53FeatureReport 6 54 Field 0, app UPS, phys PowerSummary 55 Usage 0, Charging = 0 56 Field 1, app UPS, phys PowerSummary 57 Usage 0, Discharging = 0 58 Field 2, app UPS, phys PowerSummary 59 Usage 0, APCStatusFlag = 8 0x8 60 61FeatureReport 7 62 Field 0, app UPS, phys PowerSummary 63 Usage 0, ManufactureDate = 10896 2001-04-16 64 65FeatureReport 8 66 Field 0, app UPS, phys PowerSummary 67 Usage 0, ConfigVoltage = 1200 CentiVolts 68 69FeatureReport 9 70 Field 0, app UPS, phys PowerSummary 71 Usage 0, Voltage = 1342 CentiVolts 72 73FeatureReport 10 74 Field 0, app UPS, phys PowerSummary 75 Usage 0, iManufacturer = 3 American Power Conversion 76 77FeatureReport 11 78 Field 0, app UPS, phys PowerSummary 79Exponent 0 lost. 80 Usage 0, CapacityMode = 2 percent 81 82FeatureReport 12 83 Field 0, app UPS, phys PowerSummary 84Exponent 2 lost. 85 Usage 0, RemainingCapacity = 100 percent 86 Field 1, app UPS, phys PowerSummary 87 Usage 0, RunTimeToEmpty = 1380 Seconds 88 89FeatureReport 13 90 Field 0, app UPS, phys PowerSummary 91Exponent 0 lost. 92 Usage 0, DesignCapacity = 100 percent 93 94FeatureReport 14 95 Field 0, app UPS, phys PowerSummary 96Exponent 2 lost. 97 Usage 0, FullChargeCapacity = 100 percent 98 99FeatureReport 15 100 Field 0, app UPS, phys PowerSummary 101Exponent 2 lost. 102 Usage 0, WarningCapacityLimit = 50 percent 103 104FeatureReport 16 105 Field 0, app UPS, phys PowerSummary 106Exponent 2 lost. 107 Usage 0, CapacityGranularity2 = 1 percent 108 109FeatureReport 17 110 Field 0, app UPS, phys PowerSummary 111Exponent 2 lost. 112 Usage 0, RemainingCapacityLimit = 10 percent 113 114FeatureReport 18 115 Field 0, app UPS, phys PowerSummary 116Exponent 2 lost. 117 Usage 0, CapacityGranularity1 = 1 percent 118 119FeatureReport 19 120 Field 0, app UPS, phys PowerSummary 121 Usage 0, ACPresent = 1 122 123FeatureReport 20 124 Field 0, app UPS, phys PowerSummary 125 Usage 0, BelowRemainingCapacityLimit = 0 126 Field 1, app UPS, phys PowerSummary 127 Usage 0, ShutdownImminent = 0 128 129FeatureReport 53 130 Field 0, app UPS, phys PowerSummary 131 Usage 0, APCPanelTest = 0 132 133FeatureReport 28 134 Field 0, app UPS, phys PowerSummary 135 Usage 0, APCBattReplacementDate = 267777 2001-04-16 136 137 138FeatureReport 64 139 Field 0, app UPS, phys APCGeneralCollection 140 Usage 0, APCForceShutdown = 0 141 142Waiting for events ... (interrupt to exit) 143Event: Voltage = 1342 144Event: RemainingCapacity = 95 145Event: Charging = 1 146Event: RunTimeToEmpty = 2580 147