1# $OpenBSD: sensorsd.conf,v 1.8 2007/08/14 19:02:02 cnst Exp $ 2# $DragonFly: src/etc/sensorsd.conf,v 1.1 2007/10/02 12:57:00 hasso Exp $ 3 4# 5# Sample sensorsd.conf file. See sensorsd.conf(5) for details. 6# 7 8# +5 voltage (volts) 9#hw.sensors.lm0.volt3:low=4.8V:high=5.2V 10 11# +12 voltage (volts) 12#hw.sensors.lm0.volt4:low=11.5V:high=12.5V 13 14# Chipset temperature (degrees Celsius) 15#hw.sensors.lm0.temp0:high=50C 16 17# CPU temperature (degrees Celsius) 18#hw.sensors.lm0.temp1:high=60C 19 20# CPU fan (RPM) 21#hw.sensors.lm0.fan1:low=3000 22 23# ignore certain indicators on ipmi(4) 24#hw.sensors.ipmi0.indicator1:istatus 25 26# Warn if any temperature sensor is over 70 degC. 27# This entry will match only those temperature sensors 28# that don't have their own entry. 29#temp:high=70C 30 31 32# By default, sensorsd(8) reports status changes of all sensors that 33# keep their state. Uncomment the following lines if you want to 34# suppress reports about status changes of specific sensor types. 35 36#temp:istatus 37#fan:istatus 38#volt:istatus 39#acvolt:istatus 40#resistance:istatus 41#power:istatus 42#current:istatus 43#watthour:istatus 44#amphour:istatus 45#indicator:istatus 46#raw:istatus 47#percentage:istatus 48#illuminance:istatus 49#drive:istatus 50#timedelta:istatus 51