xref: /freebsd/share/man/man4/ocs_fc.4 (revision 0957b409)
1.\" Copyright (c) 2017 Broadcom. All rights reserved.
2.\" The term "Broadcom" refers to Broadcom Limited and/or its subsidiaries.
3.\"
4.\" Redistribution and use in source and binary forms, with or without
5.\" modification, are permitted provided that the following conditions are met:
6.\"
7.\" 1. Redistributions of source code must retain the above copyright notice,
8.\"    this list of conditions and the following disclaimer.
9.\"
10.\" 2. Redistributions in binary form must reproduce the above copyright notice,
11.\"    this list of conditions and the following disclaimer in the documentation
12.\"    and/or other materials provided with the distribution.
13.\"
14.\" 3. Neither the name of the copyright holder nor the names of its contributors
15.\"    may be used to endorse or promote products derived from this software
16.\"    without specific prior written permission.
17.\"
18.\" THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
19.\" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
20.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
21.\" ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE
22.\" LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
23.\" CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
24.\" SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
25.\" INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
26.\" CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
27.\" ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
28.\" POSSIBILITY OF SUCH DAMAGE.
29.\"
30.\" $FreeBSD$
31.\"
32.Dd March 30, 2018
33.Dt OCS_FC 4
34.Os
35.Sh NAME
36.Nm ocs_fc
37.Nd "Device driver for Emulex Fibre Channel Host Adapters"
38.Sh SYNOPSIS
39To compile this driver into the kernel, add this line to the
40kernel configuration file:
41.Bd -ragged -offset indent
42.Cd "device ocs_fc"
43.Ed
44.Pp
45To load the driver as a module at boot, add this line to
46.Xr loader.conf 5 :
47.Bd -literal -offset indent
48ocs_fc_load="YES"
49.Ed
50.Sh DESCRIPTION
51The
52.Nm
53driver provides access to Fibre Channel SCSI devices.
54.Pp
55The
56.Nm
57driver supports initiator and target modes.
58Support is available for Arbitrated loops, Point-to-Point,
59and Fabric connections.
60FC-Tape is highly recommended for connections to tape drives that support
61it.
62FC-Tape includes four elements from the T-10 FCP-4 specification:
63.Bl -bullet -offset indent
64.It
65Precise Delivery of Commands
66.It
67Confirmed Completion of FCP I/O Operations
68.It
69Retransmission of Unsuccessfully Transmitted IUs
70.It
71Task Retry Identification
72.El
73.Pp
74Together these features allow for link level error recovery with tape
75devices.
76Without link level error recovery, an initiator cannot, for instance, tell whether a tape write
77command that has timed out resulted in all, part, or none of the data going to
78the tape drive.
79FC-Tape is automatically enabled when both the controller and target support it.
80
81.Sh HARDWARE
82The
83.Nm
84driver supports these Fibre Channel adapters:
85.Bl -tag -width xxxxxx -offset indent
86.It Emulex 16/8G FC GEN 5 HBAS
87.Bd -literal -offset indent
88LPe15004 FC Host Bus Adapters
89LPe160XX FC Host Bus Adapters
90.Ed
91.It Emulex 32/16G FC GEN 6 HBAS
92.Bd -literal -offset indent
93LPe3100X FC Host Bus Adapters
94LPe3200X FC Host Bus Adapters
95.Ed
96.El
97.Sh UPDATING FIRMWARE
98Adapter firmware updates are persistent.
99.Pp
100Firmware can be updated by following these steps:
101.Bl -enum
102.It
103Copy this code to a
104.Pa Makefile :
105.Bd -literal -offset indent
106KMOD=ocsflash
107FIRMWS=imagename.grp:ocsflash
108\&.include <bsd.kmod.mk>
109.Ed
110.It
111Replace
112.Pa imagename
113with the name of the GRP file.
114.It
115Copy the
116.Pa Makefile
117and GRP file to a local directory
118.It
119Execute
120.Cm make
121and copy the generated
122.Pa ocsflash.ko
123file to
124.Pa /lib/modules
125.It
126.Cm sysctl dev.ocs_fc.<N>.fw_upgrade=ocsflash
127.It
128Check kernel messages regarding status of the operation
129.It
130Reboot the machine
131.El
132.Pp
133.Sh BOOT OPTIONS
134Options are controlled by setting values in
135.Pa /boot/device.hints .
136.Pp
137They are:
138.Bl -tag -width indent
139.It Va hint.ocs_fc.N.initiator
140Enable initiator functionality.
141Default 1 (enabled), 0 to disable.
142.It Va hint.ocs_fc.N.target
143Enable target functionality.
144Default 1 (enabled), 0 to disable.
145.It Va hint.ocs_fc.N.topology
146Topology: 0 for Auto, 1 for NPort only, 2 for Loop only.
147.It Va hint.ocs_fc.N.speed
148Link speed in megabits per second.
149Possible values include:
1500 Auto-speed negotiation (default), 4000 (4GFC), 8000 (8GFC), 16000 (16GFC).
151.El
152.Sh SYSCTL OPTIONS
153.Bl -tag -width indent
154.It Va dev.ocs_fc.N.port_state
155Port state (read/write).
156Valid values are
157.Li online
158and
159.Li offline .
160.It Va dev.ocs_fc.N.wwpn
161World Wide Port Name (read/write).
162.It Va dev.ocs_fc.N.wwnn
163World Wide Node Name (read/write).
164.It Va dev.ocs_fc.N.fwrev
165Firmware revision (read-only).
166.It Va dev.ocs_fc.N.sn
167Adapter serial number (read-only).
168.It Va dev.ocs_fc.N.configured_speed
169Configured Port Speed (read/write).
170Valid values are:
1710 Auto-speed negotiation (default), 4000 (4GFC), 8000 (8GFC), 16000 (16GFC).
172.It Va dev.ocs_fc.N.configured_topology
173Configured Port Topology (read/write).
174Valid values are:
1750-Auto; 1-NPort; 2-Loop.
176.It Va dev.ocs_fc.N.current_speed
177Current Port Speed (read-only).
178.It Va dev.ocs_fc.N.current_topology
179Current Port Topology (read-only).
180.El
181.Sh SUPPORT
182For general information and support,
183go to the Broadcom website at:
184.Pa http://www.broadcom.com/
185or E-Mail at
186.Pa ocs-driver-team.pdl@broadcom.com.
187.Sh SEE ALSO
188.Xr ifconfig 8
189.Sh AUTHORS
190.An -nosplit
191The
192.Nm
193driver was written by
194.An Broadcom.