xref: /illumos-gate/usr/src/cmd/fm/dicts/PCI.po (revision 00d0963f)
17c478bd9Sstevel@tonic-gate#
2*00d0963fSdilpreet# Copyright 2006 Sun Microsystems, Inc.  All rights reserved.
37c478bd9Sstevel@tonic-gate# Use is subject to license terms.
47c478bd9Sstevel@tonic-gate#
57c478bd9Sstevel@tonic-gate# CDDL HEADER START
67c478bd9Sstevel@tonic-gate#
77c478bd9Sstevel@tonic-gate# The contents of this file are subject to the terms of the
8*00d0963fSdilpreet# Common Development and Distribution License (the "License").
9*00d0963fSdilpreet# You may not use this file except in compliance with the License.
107c478bd9Sstevel@tonic-gate#
117c478bd9Sstevel@tonic-gate# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
127c478bd9Sstevel@tonic-gate# or http://www.opensolaris.org/os/licensing.
137c478bd9Sstevel@tonic-gate# See the License for the specific language governing permissions
147c478bd9Sstevel@tonic-gate# and limitations under the License.
157c478bd9Sstevel@tonic-gate#
167c478bd9Sstevel@tonic-gate# When distributing Covered Code, include this CDDL HEADER in each
177c478bd9Sstevel@tonic-gate# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
187c478bd9Sstevel@tonic-gate# If applicable, add the following below this CDDL HEADER, with the
197c478bd9Sstevel@tonic-gate# fields enclosed by brackets "[]" replaced with your own identifying
207c478bd9Sstevel@tonic-gate# information: Portions Copyright [yyyy] [name of copyright owner]
217c478bd9Sstevel@tonic-gate#
227c478bd9Sstevel@tonic-gate# CDDL HEADER END
237c478bd9Sstevel@tonic-gate#
247c478bd9Sstevel@tonic-gate#ident	"%Z%%M%	%I%	%E% SMI"
25*00d0963fSdilpreet#
26*00d0963fSdilpreet# DO NOT EDIT -- this file is generated by the Event Registry.
27*00d0963fSdilpreet#
287c478bd9Sstevel@tonic-gate#
297c478bd9Sstevel@tonic-gate# code: PCI-8000-0C
307c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver
317c478bd9Sstevel@tonic-gate#
327c478bd9Sstevel@tonic-gatemsgid "PCI-8000-0C.type"
337c478bd9Sstevel@tonic-gatemsgstr "Fault"
347c478bd9Sstevel@tonic-gatemsgid "PCI-8000-0C.severity"
357c478bd9Sstevel@tonic-gatemsgstr "Critical"
367c478bd9Sstevel@tonic-gatemsgid "PCI-8000-0C.description"
37*00d0963fSdilpreetmsgstr "A problem was detected in the PCI controller software.  Refer to %s for more information."
387c478bd9Sstevel@tonic-gatemsgid "PCI-8000-0C.response"
39*00d0963fSdilpreetmsgstr "One or more of device instances may be disabled."
407c478bd9Sstevel@tonic-gatemsgid "PCI-8000-0C.impact"
41*00d0963fSdilpreetmsgstr "Loss of services provided by the device instances associated with this problem."
427c478bd9Sstevel@tonic-gatemsgid "PCI-8000-0C.action"
437c478bd9Sstevel@tonic-gatemsgstr "Ensure latest drivers and patches are installed.  Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support."
447c478bd9Sstevel@tonic-gate#
457c478bd9Sstevel@tonic-gate# code: PCI-8000-1Q
467c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus
477c478bd9Sstevel@tonic-gate#
487c478bd9Sstevel@tonic-gatemsgid "PCI-8000-1Q.type"
497c478bd9Sstevel@tonic-gatemsgstr "Fault"
507c478bd9Sstevel@tonic-gatemsgid "PCI-8000-1Q.severity"
517c478bd9Sstevel@tonic-gatemsgstr "Critical"
527c478bd9Sstevel@tonic-gatemsgid "PCI-8000-1Q.description"
537c478bd9Sstevel@tonic-gatemsgstr "A problem was detected for a PCI bus.  Refer to %s for more information."
547c478bd9Sstevel@tonic-gatemsgid "PCI-8000-1Q.response"
55*00d0963fSdilpreetmsgstr "One or more device instances may be disabled."
567c478bd9Sstevel@tonic-gatemsgid "PCI-8000-1Q.impact"
57*00d0963fSdilpreetmsgstr "Loss of services provided by the device instances associated with this fault."
587c478bd9Sstevel@tonic-gatemsgid "PCI-8000-1Q.action"
597c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected device.  Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support."
607c478bd9Sstevel@tonic-gate#
617c478bd9Sstevel@tonic-gate# code: PCI-8000-24
627c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus
637c478bd9Sstevel@tonic-gate#
647c478bd9Sstevel@tonic-gatemsgid "PCI-8000-24.type"
657c478bd9Sstevel@tonic-gatemsgstr "Fault"
667c478bd9Sstevel@tonic-gatemsgid "PCI-8000-24.severity"
677c478bd9Sstevel@tonic-gatemsgstr "Critical"
687c478bd9Sstevel@tonic-gatemsgid "PCI-8000-24.description"
69*00d0963fSdilpreetmsgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
707c478bd9Sstevel@tonic-gatemsgid "PCI-8000-24.response"
71*00d0963fSdilpreetmsgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
727c478bd9Sstevel@tonic-gatemsgid "PCI-8000-24.impact"
73*00d0963fSdilpreetmsgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
747c478bd9Sstevel@tonic-gatemsgid "PCI-8000-24.action"
75*00d0963fSdilpreetmsgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
767c478bd9Sstevel@tonic-gate#
777c478bd9Sstevel@tonic-gate# code: PCI-8000-3R
787c478bd9Sstevel@tonic-gate# keys: fault.io.pci.device
797c478bd9Sstevel@tonic-gate#
807c478bd9Sstevel@tonic-gatemsgid "PCI-8000-3R.type"
817c478bd9Sstevel@tonic-gatemsgstr "Fault"
827c478bd9Sstevel@tonic-gatemsgid "PCI-8000-3R.severity"
837c478bd9Sstevel@tonic-gatemsgstr "Critical"
847c478bd9Sstevel@tonic-gatemsgid "PCI-8000-3R.description"
85*00d0963fSdilpreetmsgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem.  Refer to %s for more information."
867c478bd9Sstevel@tonic-gatemsgid "PCI-8000-3R.response"
87*00d0963fSdilpreetmsgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
887c478bd9Sstevel@tonic-gatemsgid "PCI-8000-3R.impact"
89*00d0963fSdilpreetmsgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
907c478bd9Sstevel@tonic-gatemsgid "PCI-8000-3R.action"
91*00d0963fSdilpreetmsgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device."
927c478bd9Sstevel@tonic-gate#
937c478bd9Sstevel@tonic-gate# code: PCI-8000-42
947c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.device
957c478bd9Sstevel@tonic-gate#
967c478bd9Sstevel@tonic-gatemsgid "PCI-8000-42.type"
977c478bd9Sstevel@tonic-gatemsgstr "Fault"
987c478bd9Sstevel@tonic-gatemsgid "PCI-8000-42.severity"
997c478bd9Sstevel@tonic-gatemsgstr "Critical"
1007c478bd9Sstevel@tonic-gatemsgid "PCI-8000-42.description"
101*00d0963fSdilpreetmsgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
1027c478bd9Sstevel@tonic-gatemsgid "PCI-8000-42.response"
103*00d0963fSdilpreetmsgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1047c478bd9Sstevel@tonic-gatemsgid "PCI-8000-42.impact"
105*00d0963fSdilpreetmsgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1067c478bd9Sstevel@tonic-gatemsgid "PCI-8000-42.action"
107*00d0963fSdilpreetmsgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
1087c478bd9Sstevel@tonic-gate#
1097c478bd9Sstevel@tonic-gate# code: PCI-8000-5X
1107c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.pci.device
1117c478bd9Sstevel@tonic-gate#
1127c478bd9Sstevel@tonic-gatemsgid "PCI-8000-5X.type"
1137c478bd9Sstevel@tonic-gatemsgstr "Fault"
1147c478bd9Sstevel@tonic-gatemsgid "PCI-8000-5X.severity"
1157c478bd9Sstevel@tonic-gatemsgstr "Critical"
1167c478bd9Sstevel@tonic-gatemsgid "PCI-8000-5X.description"
117*00d0963fSdilpreetmsgstr "The system has diagnosed a problem in one or more PCI buses or devices, \nbased on the error telemetry detected by the PCI subsystem.  Refer to %s for more information."
1187c478bd9Sstevel@tonic-gatemsgid "PCI-8000-5X.response"
119*00d0963fSdilpreetmsgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1207c478bd9Sstevel@tonic-gatemsgid "PCI-8000-5X.impact"
121*00d0963fSdilpreetmsgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1227c478bd9Sstevel@tonic-gatemsgid "PCI-8000-5X.action"
123*00d0963fSdilpreetmsgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).\n\nSchedule a repair procedure to replace the affected device."
1247c478bd9Sstevel@tonic-gate#
1257c478bd9Sstevel@tonic-gate# code: PCI-8000-6E
1267c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device
1277c478bd9Sstevel@tonic-gate#
1287c478bd9Sstevel@tonic-gatemsgid "PCI-8000-6E.type"
1297c478bd9Sstevel@tonic-gatemsgstr "Fault"
1307c478bd9Sstevel@tonic-gatemsgid "PCI-8000-6E.severity"
1317c478bd9Sstevel@tonic-gatemsgstr "Critical"
1327c478bd9Sstevel@tonic-gatemsgid "PCI-8000-6E.description"
133*00d0963fSdilpreetmsgstr "The system has diagnosed a problem, the suspects include one or more \nPCI buses and one or more PCI controller drivers.  Refer to %s for more information."
1347c478bd9Sstevel@tonic-gatemsgid "PCI-8000-6E.response"
135*00d0963fSdilpreetmsgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
1367c478bd9Sstevel@tonic-gatemsgid "PCI-8000-6E.impact"
137*00d0963fSdilpreetmsgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
1387c478bd9Sstevel@tonic-gatemsgid "PCI-8000-6E.action"
139*00d0963fSdilpreetmsgstr "Use fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s)or driver(s).\n\nCheck for patches to identified device drivers, schedule a repair for \nindicated hardware.\n"
140*00d0963fSdilpreet#
141*00d0963fSdilpreet# code: PCI-8000-7J
142*00d0963fSdilpreet# keys: fault.io.pci.device-interr
143*00d0963fSdilpreet#
144*00d0963fSdilpreetmsgid "PCI-8000-7J.type"
145*00d0963fSdilpreetmsgstr "Fault"
146*00d0963fSdilpreetmsgid "PCI-8000-7J.severity"
147*00d0963fSdilpreetmsgstr "Critical"
148*00d0963fSdilpreetmsgid "PCI-8000-7J.description"
149*00d0963fSdilpreetmsgstr "A problem was detected for a PCI device.\n  Refer to %s for more information."
150*00d0963fSdilpreetmsgid "PCI-8000-7J.response"
151*00d0963fSdilpreetmsgstr "One or more device instances may be disabled\n"
152*00d0963fSdilpreetmsgid "PCI-8000-7J.impact"
153*00d0963fSdilpreetmsgstr "Possible loss of services provided by the device instances associated with this fault\n"
154*00d0963fSdilpreetmsgid "PCI-8000-7J.action"
155*00d0963fSdilpreetmsgstr "Schedule a repair procedure to replace the affected device.  Use fmdump -v -u  to identify the device or contact Sun for support.\n"
156*00d0963fSdilpreet#
157*00d0963fSdilpreet# code: PCI-8000-8S
158*00d0963fSdilpreet# keys: fault.io.pci.bus-linkerr fault.io.pci.device-interr
159*00d0963fSdilpreet#
160*00d0963fSdilpreetmsgid "PCI-8000-8S.type"
161*00d0963fSdilpreetmsgstr "Fault"
162*00d0963fSdilpreetmsgid "PCI-8000-8S.severity"
163*00d0963fSdilpreetmsgstr "Critical"
164*00d0963fSdilpreetmsgid "PCI-8000-8S.description"
165*00d0963fSdilpreetmsgstr "A problem has been detected on the specified bus or on the specified transmitting device.\n  Refer to %s for more information."
166*00d0963fSdilpreetmsgid "PCI-8000-8S.response"
167*00d0963fSdilpreetmsgstr "One or more device instances may be disabled\n"
168*00d0963fSdilpreetmsgid "PCI-8000-8S.impact"
169*00d0963fSdilpreetmsgstr "Possible loss of services provided by the device instances associated with this fault\n"
170*00d0963fSdilpreetmsgid "PCI-8000-8S.action"
171*00d0963fSdilpreetmsgstr "If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device.  Use fmdump -v -u  to identify the device and bus or contact Sun for support.\n"
172*00d0963fSdilpreet#
173*00d0963fSdilpreet# code: PCI-8000-95
174*00d0963fSdilpreet# keys: fault.io.pci.device-invreq fault.io.pci.device-noresp
175*00d0963fSdilpreet#
176*00d0963fSdilpreetmsgid "PCI-8000-95.type"
177*00d0963fSdilpreetmsgstr "Fault"
178*00d0963fSdilpreetmsgid "PCI-8000-95.severity"
179*00d0963fSdilpreetmsgstr "Critical"
180*00d0963fSdilpreetmsgid "PCI-8000-95.description"
181*00d0963fSdilpreetmsgstr "Either the transmitting device sent an invalid request or the receiving device failed to respond.\n  Refer to %s for more information."
182*00d0963fSdilpreetmsgid "PCI-8000-95.response"
183*00d0963fSdilpreetmsgstr "One or more device instances may be disabled\n"
184*00d0963fSdilpreetmsgid "PCI-8000-95.impact"
185*00d0963fSdilpreetmsgstr "Possible loss of services provided by the device instances associated with this fault\n"
186*00d0963fSdilpreetmsgid "PCI-8000-95.action"
187*00d0963fSdilpreetmsgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmdump -v -u  to identify the devices or contact Sun for support.\n"
188*00d0963fSdilpreet#
189*00d0963fSdilpreet# code: PCI-8000-AP
190*00d0963fSdilpreet# keys: fault.io.pci.device-interr fault.io.pci.device-invreq
191*00d0963fSdilpreet#
192*00d0963fSdilpreetmsgid "PCI-8000-AP.type"
193*00d0963fSdilpreetmsgstr "Fault"
194*00d0963fSdilpreetmsgid "PCI-8000-AP.severity"
195*00d0963fSdilpreetmsgstr "Critical"
196*00d0963fSdilpreetmsgid "PCI-8000-AP.description"
197*00d0963fSdilpreetmsgstr "Either the transmitting device sent an invalid request or the receiving device is reporting an internal fault.\n  Refer to %s for more information."
198*00d0963fSdilpreetmsgid "PCI-8000-AP.response"
199*00d0963fSdilpreetmsgstr "One or more device instances may be disabled\n"
200*00d0963fSdilpreetmsgid "PCI-8000-AP.impact"
201*00d0963fSdilpreetmsgstr "Possible loss of services provided by the device instances associated with this fault\n"
202*00d0963fSdilpreetmsgid "PCI-8000-AP.action"
203*00d0963fSdilpreetmsgstr "Ensure that the latest drivers and patches are installed.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmdump -v -u  to identify the devices or contact Sun for support.\n"
204*00d0963fSdilpreet#
205*00d0963fSdilpreet# code: PCI-8000-CA
206*00d0963fSdilpreet# keys: fault.io.pci.device-noresp
207*00d0963fSdilpreet#
208*00d0963fSdilpreetmsgid "PCI-8000-CA.type"
209*00d0963fSdilpreetmsgstr "Fault"
210*00d0963fSdilpreetmsgid "PCI-8000-CA.severity"
211*00d0963fSdilpreetmsgstr "Critical"
212*00d0963fSdilpreetmsgid "PCI-8000-CA.description"
213*00d0963fSdilpreetmsgstr "Device is failing to respond\n  Refer to %s for more information."
214*00d0963fSdilpreetmsgid "PCI-8000-CA.response"
215*00d0963fSdilpreetmsgstr "One or more device instances may be disabled\n"
216*00d0963fSdilpreetmsgid "PCI-8000-CA.impact"
217*00d0963fSdilpreetmsgstr "Possible loss of services provided by the device instances associated with this fault\n"
218*00d0963fSdilpreetmsgid "PCI-8000-CA.action"
219*00d0963fSdilpreetmsgstr "Schedule a repair procedure to replace the affected device.  Use fmdump -v -u  to identify the device or contact Sun for support.\n"