xref: /netbsd/sbin/fsck/partutil.c (revision 6550d01e)
1 /*	$NetBSD: partutil.c,v 1.10 2010/03/06 00:30:54 christos Exp $	*/
2 
3 /*-
4  * Copyright (c) 2006 The NetBSD Foundation, Inc.
5  * All rights reserved.
6  *
7  * This code is derived from software contributed to The NetBSD Foundation
8  * by Christos Zoulas.
9  *
10  * Redistribution and use in source and binary forms, with or without
11  * modification, are permitted provided that the following conditions
12  * are met:
13  * 1. Redistributions of source code must retain the above copyright
14  *    notice, this list of conditions and the following disclaimer.
15  * 2. Redistributions in binary form must reproduce the above copyright
16  *    notice, this list of conditions and the following disclaimer in the
17  *    documentation and/or other materials provided with the distribution.
18  *
19  * THIS SOFTWARE IS PROVIDED BY THE NETBSD FOUNDATION, INC. AND CONTRIBUTORS
20  * ``AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED
21  * TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
22  * PURPOSE ARE DISCLAIMED.  IN NO EVENT SHALL THE FOUNDATION OR CONTRIBUTORS
23  * BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
24  * CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
25  * SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
26  * INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
27  * CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
28  * ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
29  * POSSIBILITY OF SUCH DAMAGE.
30  */
31 
32 #include <sys/cdefs.h>
33 __RCSID("$NetBSD: partutil.c,v 1.10 2010/03/06 00:30:54 christos Exp $");
34 
35 #include <sys/types.h>
36 #include <sys/disklabel.h>
37 #include <sys/disk.h>
38 #include <sys/ioctl.h>
39 #include <sys/stat.h>
40 
41 
42 #include <disktab.h>
43 #include <err.h>
44 #include <errno.h>
45 #include <fcntl.h>
46 #include <util.h>
47 #include <unistd.h>
48 #include <stdlib.h>
49 #include <string.h>
50 
51 #include <prop/proplib.h>
52 
53 #include "partutil.h"
54 
55 /*
56  * Convert disklabel geometry info to disk_geom.
57  */
58 static void
59 label2geom(struct disk_geom *geo, const struct disklabel *lp)
60 {
61 	geo->dg_secperunit = lp->d_secperunit;
62 	geo->dg_secsize = lp->d_secsize;
63 	geo->dg_nsectors = lp->d_nsectors;
64 	geo->dg_ntracks = lp->d_ntracks;
65 	geo->dg_ncylinders = lp->d_ncylinders;
66 	geo->dg_secpercyl = lp->d_secpercyl;
67 	geo->dg_pcylinders = lp->d_ncylinders;
68 	geo->dg_sparespertrack = lp->d_sparespertrack;
69 	geo->dg_sparespercyl = lp->d_sparespercyl;
70 	geo->dg_acylinders = lp->d_acylinders;
71 }
72 
73 /*
74  * Set what we need to know about disk geometry.
75  */
76 static void
77 dict2geom(struct disk_geom *geo, prop_dictionary_t dict)
78 {
79 	(void)memset(geo, 0, sizeof(struct disk_geom));
80 	prop_dictionary_get_int64(dict, "sectors-per-unit",
81 	    &geo->dg_secperunit);
82 	prop_dictionary_get_uint32(dict, "sector-size", &geo->dg_secsize);
83 	prop_dictionary_get_uint32(dict, "sectors-per-track",
84 	    &geo->dg_nsectors);
85 	prop_dictionary_get_uint32(dict, "tracks-per-cylinder",
86 	    &geo->dg_ntracks);
87 	prop_dictionary_get_uint32(dict, "cylinders-per-unit",
88 	    &geo->dg_ncylinders);
89 }
90 
91 
92 static void
93 part2wedge(struct dkwedge_info *dkw, const struct disklabel *lp, const char *s)
94 {
95 	struct stat sb;
96 	const struct partition *pp;
97 	int ptn;
98 
99 	(void)memset(dkw, 0, sizeof(*dkw));
100 	if (stat(s, &sb) == -1)
101 		return;
102 
103 	ptn = strchr(s, '\0')[-1] - 'a';
104 	if ((unsigned)ptn >= lp->d_npartitions ||
105 	    (devminor_t)ptn != DISKPART(sb.st_rdev))
106 		return;
107 
108 	pp = &lp->d_partitions[ptn];
109 	dkw->dkw_offset = pp->p_offset;
110 	dkw->dkw_size = pp->p_size;
111 	dkw->dkw_parent[0] = '*';
112 	switch (pp->p_fstype) {
113 	default:
114 		(void)strcpy(dkw->dkw_ptype, DKW_PTYPE_UNKNOWN);
115 		break;
116 	case FS_UNUSED:
117 		(void)strcpy(dkw->dkw_ptype, DKW_PTYPE_UNUSED);
118 		break;
119 	case FS_SWAP:
120 		(void)strcpy(dkw->dkw_ptype, DKW_PTYPE_SWAP);
121 		break;
122 	case FS_BSDFFS:
123 		(void)strcpy(dkw->dkw_ptype, DKW_PTYPE_FFS);
124 		break;
125 	case FS_BSDLFS:
126 		(void)strcpy(dkw->dkw_ptype, DKW_PTYPE_LFS);
127 		break;
128 	case FS_EX2FS:
129 		(void)strcpy(dkw->dkw_ptype, DKW_PTYPE_EXT2FS);
130 		break;
131 	case FS_ISO9660:
132 		(void)strcpy(dkw->dkw_ptype, DKW_PTYPE_ISO9660);
133 		break;
134 	case FS_ADOS:
135 		(void)strcpy(dkw->dkw_ptype, DKW_PTYPE_AMIGADOS);
136 		break;
137 	case FS_HFS:
138 		(void)strcpy(dkw->dkw_ptype, DKW_PTYPE_APPLEHFS);
139 		break;
140 	case FS_MSDOS:
141 		(void)strcpy(dkw->dkw_ptype, DKW_PTYPE_FAT);
142 		break;
143 	case FS_FILECORE:
144 		(void)strcpy(dkw->dkw_ptype, DKW_PTYPE_FILECORE);
145 		break;
146 	case FS_APPLEUFS:
147 		(void)strcpy(dkw->dkw_ptype, DKW_PTYPE_APPLEUFS);
148 		break;
149 	case FS_NTFS:
150 		(void)strcpy(dkw->dkw_ptype, DKW_PTYPE_NTFS);
151 		break;
152 	}
153 }
154 
155 int
156 getdiskinfo(const char *s, int fd, const char *dt, struct disk_geom *geo,
157     struct dkwedge_info *dkw)
158 {
159 	struct disklabel lab;
160 	struct disklabel *lp = &lab;
161 	prop_dictionary_t disk_dict, geom_dict;
162 
163 	if (dt) {
164 		lp = getdiskbyname(dt);
165 		if (lp == NULL)
166 			errx(1, "unknown disk type `%s'", dt);
167 	}
168 
169 	/* Get disk description dictionary */
170 	if (prop_dictionary_recv_ioctl(fd, DIOCGDISKINFO, &disk_dict)) {
171 		/*
172 		 * Ask for disklabel if DIOCGDISKINFO failed. This is
173 		 * compatibility call and can be removed when all devices
174 		 * will support DIOCGDISKINFO.
175 		 * cgd, ccd pseudo disk drives doesn't support DIOCGDDISKINFO
176 		 */
177 		if (ioctl(fd, DIOCGDINFO, lp) == -1) {
178 			warn("DIOCGDINFO on %s failed", s);
179 			return -1;
180 		}
181 		label2geom(geo, lp);
182 	} else {
183 		geom_dict = prop_dictionary_get(disk_dict, "geometry");
184 		dict2geom(geo, geom_dict);
185 	}
186 
187 	/* Get info about partition/wedge */
188 	if (ioctl(fd, DIOCGWEDGEINFO, dkw) == -1) {
189 		if (ioctl(fd, DIOCGDINFO, lp) == -1)
190 			err(1, "Please implement DIOCGWEDGEINFO or "
191 			    "DIOCGDINFO for disk device %s", s);
192 
193 		part2wedge(dkw, lp, s);
194 	}
195 
196 	return 0;
197 }
198