All rights reserved. The Berkeley software License Agreement
specifies the terms and conditions for redistribution.
@(#)mt.4 6.3 (Berkeley) 06/01/86
tape mu0 at mt0 slave 0
mu%d: not online. An attempt was made to access the tape while it was offline; this message is written on the terminal of the user who tried to access the tape.
mu%d: can't change density in mid-tape. An attempt was made to write on a tape at a different density than is already recorded on the tape. This message is written on the terminal of the user who tried to switch the density.
mu%d: hard error bn%d mbsr=%b er=%x ds=%b. A tape error occurred at block bn; the mt error register and drive status register are printed in octal with the bits symbolically decoded. Any error is fatal on non-raw tape; when possible the driver will have retried the operation which failed several times before reporting the error.
mu%d: blank tape. An attempt was made to read a blank tape (a tape without even end-of-file marks).
mu%d: offline. During an i/o operation the device was set offline. If a non-raw tape was used in the access it is closed.
Because 800 bpi tapes are not supported, the numbering of minor devices is inconsistent with triple-density tape units. Unit 0 is drive 0, 1600 bpi.