All rights reserved. The Berkeley software License Agreement
specifies the terms and conditions for redistribution.
@(#)up.4 6.3 (Berkeley) 06/13/88
"disk up0 at sc0 drive 0"
Files with minor device numbers 0 through 7 refer to various portions of drive 0; minor devices 8 through 15 refer to drive 1, etc. The standard device names begin with ``up'' followed by the drive number and then a letter a-h for partitions 0-7 respectively. The character ? stands here for a drive number in the range 0-7.
The block files access the disk via the system's normal buffering mechanism and may be read and written without regard to physical disk records. There is also a `raw' interface which provides for direct transmission between the disk and the user's read or write buffer. A single read or write call results in exactly one I/O operation and therefore raw I/O is considerably more efficient when many words are transmitted. The names of the raw files conventionally begin with an extra `r.'
In raw I/O counts should be a multiple of 512 bytes (a disk sector). Likewise seek calls should specify a multiple of 512 bytes.
CDC 9762 partitions disk start length cyls hp?a 0 15884 0-99 hp?b 16000 33440 100-309 hp?c 0 131680 0-822 hp?d 49600 15884 309-408 hp?e 65440 55936 409-758 hp?f 121440 10080 759-822 hp?g 49600 82080 309-822CDC 9766 300M drive partitions: disk start length cyl up?a 0 15884 0-26 up?b 16416 33440 27-81 up?c 0 500384 0-822 up?d 341696 15884 562-588 up?e 358112 55936 589-680 up?f 414048 861760 681-822 up?g 341696 158528 562-822 up?h 49856 291346 82-561
AMPEX DM980 partitions disk start length cyls hp?a 0 15884 0-99 hp?b 16000 33440 100-309 hp?c 0 131680 0-822 hp?d 49600 15884 309-408 hp?e 65440 55936 409-758 hp?f 121440 10080 759-822 hp?g 49600 82080 309-822
AMPEX 9300 300M drive partitions: disk start length cyl up?a 0 15884 0-26 up?b 16416 33440 27-81 up?c 0 495520 0-814 up?d 341696 15884 562-588 up?e 358112 55936 589-680 up?f 414048 81312 681-814 up?g 341696 153664 562-814 up?h 49856 291346 82-561
AMPEX Capricorn 330M drive partitions: disk start length cyl hp?a 0 15884 0-31 hp?b 16384 33440 32-97 hp?c 0 524288 0-1023 hp?d 342016 15884 668-699 hp?e 358400 55936 700-809 hp?f 414720 109408 810-1023 hp?g 342016 182112 668-1023 hp?h 50176 291346 98-667
FUJITSU 160M drive partitions: disk start length cyl up?a 0 15884 0-49 up?b 16000 33440 50-154 up?c 0 263360 0-822 up?d 49600 15884 155-204 up?e 65600 55936 205-379 up?f 121600 141600 380-822 up?g 49600 213600 155-822
FUJITSU Eagle partitions disk start length cyls hp?a 0 15884 0-16 hp?b 16320 66880 17-86 hp?c 0 808320 0-841 hp?d 375360 15884 391-407 hp?e 391680 55936 408-727 hp?f 698880 109248 728-841 hp?g 375360 432768 391-841 hp?h 83520 291346 87-390
It is unwise for all of these files to be present in one installation, since there is overlap in addresses and protection becomes a sticky matter. The up?a partition is normally used for the root file system, the up?b partition as a paging area, and the up?c partition for pack-pack copying (it maps the entire disk). On 160M drives the up?g partition maps the rest of the pack. On other drives both up?g and up?h are used to map the remaining cylinders.
up%d: write locked. The write protect switch was set on the drive when a write was attempted. The write operation is not recoverable.
up%d: not ready. The drive was spun down or off line when it was accessed. The i/o operation is not recoverable.
up%d: not ready (flakey). The drive was not ready, but after printing the message about being not ready (which takes a fraction of a second) was ready. The operation is recovered if no further errors occur.
up%d%c: soft ecc reading fsbn %d[-%d]. A recoverable ECC error occurred on the specified sector of the specified disk partition. This happens normally a few times a week. If it happens more frequently than this the sectors where the errors are occurring should be checked to see if certain cylinders on the pack, spots on the carriage of the drive or heads are indicated.
sc%d: lost interrupt. A timer watching the controller detecting no interrupt for an extended period while an operation was outstanding. This indicates a hardware or software failure. There is currently a hardware/software problem with spinning down drives while they are being accessed which causes this error to occur. The error causes a UNIBUS reset, and retry of the pending operations. If the controller continues to lose interrupts, this error will recur a few seconds later.
A program to analyze the logged error information (even in its present reduced form) is needed.
The partition tables for the file systems should be read off of each pack, as they are never quite what any single installation would prefer, and this would make packs more portable.