xref: /qemu/docs/interop/vhost-user.rst (revision 4d7dd4ed)
1.. _vhost_user_proto:
2
3===================
4Vhost-user Protocol
5===================
6
7..
8  Copyright 2014 Virtual Open Systems Sarl.
9  Copyright 2019 Intel Corporation
10  Licence: This work is licensed under the terms of the GNU GPL,
11           version 2 or later. See the COPYING file in the top-level
12           directory.
13
14.. contents:: Table of Contents
15
16Introduction
17============
18
19This protocol is aiming to complement the ``ioctl`` interface used to
20control the vhost implementation in the Linux kernel. It implements
21the control plane needed to establish virtqueue sharing with a user
22space process on the same host. It uses communication over a Unix
23domain socket to share file descriptors in the ancillary data of the
24message.
25
26The protocol defines 2 sides of the communication, *front-end* and
27*back-end*. The *front-end* is the application that shares its virtqueues, in
28our case QEMU. The *back-end* is the consumer of the virtqueues.
29
30In the current implementation QEMU is the *front-end*, and the *back-end*
31is the external process consuming the virtio queues, for example a
32software Ethernet switch running in user space, such as Snabbswitch,
33or a block device back-end processing read & write to a virtual
34disk. In order to facilitate interoperability between various back-end
35implementations, it is recommended to follow the :ref:`Backend program
36conventions <backend_conventions>`.
37
38The *front-end* and *back-end* can be either a client (i.e. connecting) or
39server (listening) in the socket communication.
40
41Support for platforms other than Linux
42--------------------------------------
43
44While vhost-user was initially developed targeting Linux, nowadays it
45is supported on any platform that provides the following features:
46
47- A way for requesting shared memory represented by a file descriptor
48  so it can be passed over a UNIX domain socket and then mapped by the
49  other process.
50
51- AF_UNIX sockets with SCM_RIGHTS, so QEMU and the other process can
52  exchange messages through it, including ancillary data when needed.
53
54- Either eventfd or pipe/pipe2. On platforms where eventfd is not
55  available, QEMU will automatically fall back to pipe2 or, as a last
56  resort, pipe. Each file descriptor will be used for receiving or
57  sending events by reading or writing (respectively) an 8-byte value
58  to the corresponding it. The 8-value itself has no meaning and
59  should not be interpreted.
60
61Message Specification
62=====================
63
64.. Note:: All numbers are in the machine native byte order.
65
66A vhost-user message consists of 3 header fields and a payload.
67
68+---------+-------+------+---------+
69| request | flags | size | payload |
70+---------+-------+------+---------+
71
72Header
73------
74
75:request: 32-bit type of the request
76
77:flags: 32-bit bit field
78
79- Lower 2 bits are the version (currently 0x01)
80- Bit 2 is the reply flag - needs to be sent on each reply from the back-end
81- Bit 3 is the need_reply flag - see :ref:`REPLY_ACK <reply_ack>` for
82  details.
83
84:size: 32-bit size of the payload
85
86Payload
87-------
88
89Depending on the request type, **payload** can be:
90
91A single 64-bit integer
92^^^^^^^^^^^^^^^^^^^^^^^
93
94+-----+
95| u64 |
96+-----+
97
98:u64: a 64-bit unsigned integer
99
100A vring state description
101^^^^^^^^^^^^^^^^^^^^^^^^^
102
103+-------+-----+
104| index | num |
105+-------+-----+
106
107:index: a 32-bit index
108
109:num: a 32-bit number
110
111A vring address description
112^^^^^^^^^^^^^^^^^^^^^^^^^^^
113
114+-------+-------+------+------------+------+-----------+-----+
115| index | flags | size | descriptor | used | available | log |
116+-------+-------+------+------------+------+-----------+-----+
117
118:index: a 32-bit vring index
119
120:flags: a 32-bit vring flags
121
122:descriptor: a 64-bit ring address of the vring descriptor table
123
124:used: a 64-bit ring address of the vring used ring
125
126:available: a 64-bit ring address of the vring available ring
127
128:log: a 64-bit guest address for logging
129
130Note that a ring address is an IOVA if ``VIRTIO_F_IOMMU_PLATFORM`` has
131been negotiated. Otherwise it is a user address.
132
133Memory region description
134^^^^^^^^^^^^^^^^^^^^^^^^^
135
136+---------------+------+--------------+-------------+
137| guest address | size | user address | mmap offset |
138+---------------+------+--------------+-------------+
139
140:guest address: a 64-bit guest address of the region
141
142:size: a 64-bit size
143
144:user address: a 64-bit user address
145
146:mmap offset: 64-bit offset where region starts in the mapped memory
147
148When the ``VHOST_USER_PROTOCOL_F_XEN_MMAP`` protocol feature has been
149successfully negotiated, the memory region description contains two extra
150fields at the end.
151
152+---------------+------+--------------+-------------+----------------+-------+
153| guest address | size | user address | mmap offset | xen mmap flags | domid |
154+---------------+------+--------------+-------------+----------------+-------+
155
156:xen mmap flags: 32-bit bit field
157
158- Bit 0 is set for Xen foreign memory mapping.
159- Bit 1 is set for Xen grant memory mapping.
160- Bit 8 is set if the memory region can not be mapped in advance, and memory
161  areas within this region must be mapped / unmapped only when required by the
162  back-end. The back-end shouldn't try to map the entire region at once, as the
163  front-end may not allow it. The back-end should rather map only the required
164  amount of memory at once and unmap it after it is used.
165
166:domid: a 32-bit Xen hypervisor specific domain id.
167
168Single memory region description
169^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
170
171+---------+--------+
172| padding | region |
173+---------+--------+
174
175:padding: 64-bit
176
177A region is represented by Memory region description.
178
179Multiple Memory regions description
180^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
181
182+-------------+---------+---------+-----+---------+
183| num regions | padding | region0 | ... | region7 |
184+-------------+---------+---------+-----+---------+
185
186:num regions: a 32-bit number of regions
187
188:padding: 32-bit
189
190A region is represented by Memory region description.
191
192Log description
193^^^^^^^^^^^^^^^
194
195+----------+------------+
196| log size | log offset |
197+----------+------------+
198
199:log size: size of area used for logging
200
201:log offset: offset from start of supplied file descriptor where
202             logging starts (i.e. where guest address 0 would be
203             logged)
204
205An IOTLB message
206^^^^^^^^^^^^^^^^
207
208+------+------+--------------+-------------------+------+
209| iova | size | user address | permissions flags | type |
210+------+------+--------------+-------------------+------+
211
212:iova: a 64-bit I/O virtual address programmed by the guest
213
214:size: a 64-bit size
215
216:user address: a 64-bit user address
217
218:permissions flags: an 8-bit value:
219  - 0: No access
220  - 1: Read access
221  - 2: Write access
222  - 3: Read/Write access
223
224:type: an 8-bit IOTLB message type:
225  - 1: IOTLB miss
226  - 2: IOTLB update
227  - 3: IOTLB invalidate
228  - 4: IOTLB access fail
229
230Virtio device config space
231^^^^^^^^^^^^^^^^^^^^^^^^^^
232
233+--------+------+-------+---------+
234| offset | size | flags | payload |
235+--------+------+-------+---------+
236
237:offset: a 32-bit offset of virtio device's configuration space
238
239:size: a 32-bit configuration space access size in bytes
240
241:flags: a 32-bit value:
242  - 0: Vhost front-end messages used for writable fields
243  - 1: Vhost front-end messages used for live migration
244
245:payload: Size bytes array holding the contents of the virtio
246          device's configuration space
247
248Vring area description
249^^^^^^^^^^^^^^^^^^^^^^
250
251+-----+------+--------+
252| u64 | size | offset |
253+-----+------+--------+
254
255:u64: a 64-bit integer contains vring index and flags
256
257:size: a 64-bit size of this area
258
259:offset: a 64-bit offset of this area from the start of the
260         supplied file descriptor
261
262Inflight description
263^^^^^^^^^^^^^^^^^^^^
264
265+-----------+-------------+------------+------------+
266| mmap size | mmap offset | num queues | queue size |
267+-----------+-------------+------------+------------+
268
269:mmap size: a 64-bit size of area to track inflight I/O
270
271:mmap offset: a 64-bit offset of this area from the start
272              of the supplied file descriptor
273
274:num queues: a 16-bit number of virtqueues
275
276:queue size: a 16-bit size of virtqueues
277
278VhostUserShared
279^^^^^^^^^^^^^^^
280
281+------+
282| UUID |
283+------+
284
285:UUID: 16 bytes UUID, whose first three components (a 32-bit value, then
286  two 16-bit values) are stored in big endian.
287
288C structure
289-----------
290
291In QEMU the vhost-user message is implemented with the following struct:
292
293.. code:: c
294
295  typedef struct VhostUserMsg {
296      VhostUserRequest request;
297      uint32_t flags;
298      uint32_t size;
299      union {
300          uint64_t u64;
301          struct vhost_vring_state state;
302          struct vhost_vring_addr addr;
303          VhostUserMemory memory;
304          VhostUserLog log;
305          struct vhost_iotlb_msg iotlb;
306          VhostUserConfig config;
307          VhostUserVringArea area;
308          VhostUserInflight inflight;
309      };
310  } QEMU_PACKED VhostUserMsg;
311
312Communication
313=============
314
315The protocol for vhost-user is based on the existing implementation of
316vhost for the Linux Kernel. Most messages that can be sent via the
317Unix domain socket implementing vhost-user have an equivalent ioctl to
318the kernel implementation.
319
320The communication consists of the *front-end* sending message requests and
321the *back-end* sending message replies. Most of the requests don't require
322replies. Here is a list of the ones that do:
323
324* ``VHOST_USER_GET_FEATURES``
325* ``VHOST_USER_GET_PROTOCOL_FEATURES``
326* ``VHOST_USER_GET_VRING_BASE``
327* ``VHOST_USER_SET_LOG_BASE`` (if ``VHOST_USER_PROTOCOL_F_LOG_SHMFD``)
328* ``VHOST_USER_GET_INFLIGHT_FD`` (if ``VHOST_USER_PROTOCOL_F_INFLIGHT_SHMFD``)
329
330.. seealso::
331
332   :ref:`REPLY_ACK <reply_ack>`
333       The section on ``REPLY_ACK`` protocol extension.
334
335There are several messages that the front-end sends with file descriptors passed
336in the ancillary data:
337
338* ``VHOST_USER_ADD_MEM_REG``
339* ``VHOST_USER_SET_MEM_TABLE``
340* ``VHOST_USER_SET_LOG_BASE`` (if ``VHOST_USER_PROTOCOL_F_LOG_SHMFD``)
341* ``VHOST_USER_SET_LOG_FD``
342* ``VHOST_USER_SET_VRING_KICK``
343* ``VHOST_USER_SET_VRING_CALL``
344* ``VHOST_USER_SET_VRING_ERR``
345* ``VHOST_USER_SET_BACKEND_REQ_FD`` (previous name ``VHOST_USER_SET_SLAVE_REQ_FD``)
346* ``VHOST_USER_SET_INFLIGHT_FD`` (if ``VHOST_USER_PROTOCOL_F_INFLIGHT_SHMFD``)
347
348If *front-end* is unable to send the full message or receives a wrong
349reply it will close the connection. An optional reconnection mechanism
350can be implemented.
351
352If *back-end* detects some error such as incompatible features, it may also
353close the connection. This should only happen in exceptional circumstances.
354
355Any protocol extensions are gated by protocol feature bits, which
356allows full backwards compatibility on both front-end and back-end.  As
357older back-ends don't support negotiating protocol features, a feature
358bit was dedicated for this purpose::
359
360  #define VHOST_USER_F_PROTOCOL_FEATURES 30
361
362Note that VHOST_USER_F_PROTOCOL_FEATURES is the UNUSED (30) feature
363bit defined in `VIRTIO 1.1 6.3 Legacy Interface: Reserved Feature Bits
364<https://docs.oasis-open.org/virtio/virtio/v1.1/cs01/virtio-v1.1-cs01.html#x1-4130003>`_.
365VIRTIO devices do not advertise this feature bit and therefore VIRTIO
366drivers cannot negotiate it.
367
368This reserved feature bit was reused by the vhost-user protocol to add
369vhost-user protocol feature negotiation in a backwards compatible
370fashion. Old vhost-user front-end and back-end implementations continue to
371work even though they are not aware of vhost-user protocol feature
372negotiation.
373
374Ring states
375-----------
376
377Rings can be in one of three states:
378
379* stopped: the back-end must not process the ring at all.
380
381* started but disabled: the back-end must process the ring without
382  causing any side effects.  For example, for a networking device,
383  in the disabled state the back-end must not supply any new RX packets,
384  but must process and discard any TX packets.
385
386* started and enabled.
387
388Each ring is initialized in a stopped state.  The back-end must start
389ring upon receiving a kick (that is, detecting that file descriptor is
390readable) on the descriptor specified by ``VHOST_USER_SET_VRING_KICK``
391or receiving the in-band message ``VHOST_USER_VRING_KICK`` if negotiated,
392and stop ring upon receiving ``VHOST_USER_GET_VRING_BASE``.
393
394Rings can be enabled or disabled by ``VHOST_USER_SET_VRING_ENABLE``.
395
396If ``VHOST_USER_F_PROTOCOL_FEATURES`` has not been negotiated, the
397ring starts directly in the enabled state.
398
399If ``VHOST_USER_F_PROTOCOL_FEATURES`` has been negotiated, the ring is
400initialized in a disabled state and is enabled by
401``VHOST_USER_SET_VRING_ENABLE`` with parameter 1.
402
403While processing the rings (whether they are enabled or not), the back-end
404must support changing some configuration aspects on the fly.
405
406Multiple queue support
407----------------------
408
409Many devices have a fixed number of virtqueues.  In this case the front-end
410already knows the number of available virtqueues without communicating with the
411back-end.
412
413Some devices do not have a fixed number of virtqueues.  Instead the maximum
414number of virtqueues is chosen by the back-end.  The number can depend on host
415resource availability or back-end implementation details.  Such devices are called
416multiple queue devices.
417
418Multiple queue support allows the back-end to advertise the maximum number of
419queues.  This is treated as a protocol extension, hence the back-end has to
420implement protocol features first. The multiple queues feature is supported
421only when the protocol feature ``VHOST_USER_PROTOCOL_F_MQ`` (bit 0) is set.
422
423The max number of queues the back-end supports can be queried with message
424``VHOST_USER_GET_QUEUE_NUM``. Front-end should stop when the number of requested
425queues is bigger than that.
426
427As all queues share one connection, the front-end uses a unique index for each
428queue in the sent message to identify a specified queue.
429
430The front-end enables queues by sending message ``VHOST_USER_SET_VRING_ENABLE``.
431vhost-user-net has historically automatically enabled the first queue pair.
432
433Back-ends should always implement the ``VHOST_USER_PROTOCOL_F_MQ`` protocol
434feature, even for devices with a fixed number of virtqueues, since it is simple
435to implement and offers a degree of introspection.
436
437Front-ends must not rely on the ``VHOST_USER_PROTOCOL_F_MQ`` protocol feature for
438devices with a fixed number of virtqueues.  Only true multiqueue devices
439require this protocol feature.
440
441Migration
442---------
443
444During live migration, the front-end may need to track the modifications
445the back-end makes to the memory mapped regions. The front-end should mark
446the dirty pages in a log. Once it complies to this logging, it may
447declare the ``VHOST_F_LOG_ALL`` vhost feature.
448
449To start/stop logging of data/used ring writes, the front-end may send
450messages ``VHOST_USER_SET_FEATURES`` with ``VHOST_F_LOG_ALL`` and
451``VHOST_USER_SET_VRING_ADDR`` with ``VHOST_VRING_F_LOG`` in ring's
452flags set to 1/0, respectively.
453
454All the modifications to memory pointed by vring "descriptor" should
455be marked. Modifications to "used" vring should be marked if
456``VHOST_VRING_F_LOG`` is part of ring's flags.
457
458Dirty pages are of size::
459
460  #define VHOST_LOG_PAGE 0x1000
461
462The log memory fd is provided in the ancillary data of
463``VHOST_USER_SET_LOG_BASE`` message when the back-end has
464``VHOST_USER_PROTOCOL_F_LOG_SHMFD`` protocol feature.
465
466The size of the log is supplied as part of ``VhostUserMsg`` which
467should be large enough to cover all known guest addresses. Log starts
468at the supplied offset in the supplied file descriptor.  The log
469covers from address 0 to the maximum of guest regions. In pseudo-code,
470to mark page at ``addr`` as dirty::
471
472  page = addr / VHOST_LOG_PAGE
473  log[page / 8] |= 1 << page % 8
474
475Where ``addr`` is the guest physical address.
476
477Use atomic operations, as the log may be concurrently manipulated.
478
479Note that when logging modifications to the used ring (when
480``VHOST_VRING_F_LOG`` is set for this ring), ``log_guest_addr`` should
481be used to calculate the log offset: the write to first byte of the
482used ring is logged at this offset from log start. Also note that this
483value might be outside the legal guest physical address range
484(i.e. does not have to be covered by the ``VhostUserMemory`` table), but
485the bit offset of the last byte of the ring must fall within the size
486supplied by ``VhostUserLog``.
487
488``VHOST_USER_SET_LOG_FD`` is an optional message with an eventfd in
489ancillary data, it may be used to inform the front-end that the log has
490been modified.
491
492Once the source has finished migration, rings will be stopped by the
493source. No further update must be done before rings are restarted.
494
495In postcopy migration the back-end is started before all the memory has
496been received from the source host, and care must be taken to avoid
497accessing pages that have yet to be received.  The back-end opens a
498'userfault'-fd and registers the memory with it; this fd is then
499passed back over to the front-end.  The front-end services requests on the
500userfaultfd for pages that are accessed and when the page is available
501it performs WAKE ioctl's on the userfaultfd to wake the stalled
502back-end.  The front-end indicates support for this via the
503``VHOST_USER_PROTOCOL_F_PAGEFAULT`` feature.
504
505Memory access
506-------------
507
508The front-end sends a list of vhost memory regions to the back-end using the
509``VHOST_USER_SET_MEM_TABLE`` message.  Each region has two base
510addresses: a guest address and a user address.
511
512Messages contain guest addresses and/or user addresses to reference locations
513within the shared memory.  The mapping of these addresses works as follows.
514
515User addresses map to the vhost memory region containing that user address.
516
517When the ``VIRTIO_F_IOMMU_PLATFORM`` feature has not been negotiated:
518
519* Guest addresses map to the vhost memory region containing that guest
520  address.
521
522When the ``VIRTIO_F_IOMMU_PLATFORM`` feature has been negotiated:
523
524* Guest addresses are also called I/O virtual addresses (IOVAs).  They are
525  translated to user addresses via the IOTLB.
526
527* The vhost memory region guest address is not used.
528
529IOMMU support
530-------------
531
532When the ``VIRTIO_F_IOMMU_PLATFORM`` feature has been negotiated, the
533front-end sends IOTLB entries update & invalidation by sending
534``VHOST_USER_IOTLB_MSG`` requests to the back-end with a ``struct
535vhost_iotlb_msg`` as payload. For update events, the ``iotlb`` payload
536has to be filled with the update message type (2), the I/O virtual
537address, the size, the user virtual address, and the permissions
538flags. Addresses and size must be within vhost memory regions set via
539the ``VHOST_USER_SET_MEM_TABLE`` request. For invalidation events, the
540``iotlb`` payload has to be filled with the invalidation message type
541(3), the I/O virtual address and the size. On success, the back-end is
542expected to reply with a zero payload, non-zero otherwise.
543
544The back-end relies on the back-end communication channel (see :ref:`Back-end
545communication <backend_communication>` section below) to send IOTLB miss
546and access failure events, by sending ``VHOST_USER_BACKEND_IOTLB_MSG``
547requests to the front-end with a ``struct vhost_iotlb_msg`` as
548payload. For miss events, the iotlb payload has to be filled with the
549miss message type (1), the I/O virtual address and the permissions
550flags. For access failure event, the iotlb payload has to be filled
551with the access failure message type (4), the I/O virtual address and
552the permissions flags.  For synchronization purpose, the back-end may
553rely on the reply-ack feature, so the front-end may send a reply when
554operation is completed if the reply-ack feature is negotiated and
555back-ends requests a reply. For miss events, completed operation means
556either front-end sent an update message containing the IOTLB entry
557containing requested address and permission, or front-end sent nothing if
558the IOTLB miss message is invalid (invalid IOVA or permission).
559
560The front-end isn't expected to take the initiative to send IOTLB update
561messages, as the back-end sends IOTLB miss messages for the guest virtual
562memory areas it needs to access.
563
564.. _backend_communication:
565
566Back-end communication
567----------------------
568
569An optional communication channel is provided if the back-end declares
570``VHOST_USER_PROTOCOL_F_BACKEND_REQ`` protocol feature, to allow the
571back-end to make requests to the front-end.
572
573The fd is provided via ``VHOST_USER_SET_BACKEND_REQ_FD`` ancillary data.
574
575A back-end may then send ``VHOST_USER_BACKEND_*`` messages to the front-end
576using this fd communication channel.
577
578If ``VHOST_USER_PROTOCOL_F_BACKEND_SEND_FD`` protocol feature is
579negotiated, back-end can send file descriptors (at most 8 descriptors in
580each message) to front-end via ancillary data using this fd communication
581channel.
582
583Inflight I/O tracking
584---------------------
585
586To support reconnecting after restart or crash, back-end may need to
587resubmit inflight I/Os. If virtqueue is processed in order, we can
588easily achieve that by getting the inflight descriptors from
589descriptor table (split virtqueue) or descriptor ring (packed
590virtqueue). However, it can't work when we process descriptors
591out-of-order because some entries which store the information of
592inflight descriptors in available ring (split virtqueue) or descriptor
593ring (packed virtqueue) might be overridden by new entries. To solve
594this problem, the back-end need to allocate an extra buffer to store this
595information of inflight descriptors and share it with front-end for
596persistent. ``VHOST_USER_GET_INFLIGHT_FD`` and
597``VHOST_USER_SET_INFLIGHT_FD`` are used to transfer this buffer
598between front-end and back-end. And the format of this buffer is described
599below:
600
601+---------------+---------------+-----+---------------+
602| queue0 region | queue1 region | ... | queueN region |
603+---------------+---------------+-----+---------------+
604
605N is the number of available virtqueues. The back-end could get it from num
606queues field of ``VhostUserInflight``.
607
608For split virtqueue, queue region can be implemented as:
609
610.. code:: c
611
612  typedef struct DescStateSplit {
613      /* Indicate whether this descriptor is inflight or not.
614       * Only available for head-descriptor. */
615      uint8_t inflight;
616
617      /* Padding */
618      uint8_t padding[5];
619
620      /* Maintain a list for the last batch of used descriptors.
621       * Only available when batching is used for submitting */
622      uint16_t next;
623
624      /* Used to preserve the order of fetching available descriptors.
625       * Only available for head-descriptor. */
626      uint64_t counter;
627  } DescStateSplit;
628
629  typedef struct QueueRegionSplit {
630      /* The feature flags of this region. Now it's initialized to 0. */
631      uint64_t features;
632
633      /* The version of this region. It's 1 currently.
634       * Zero value indicates an uninitialized buffer */
635      uint16_t version;
636
637      /* The size of DescStateSplit array. It's equal to the virtqueue size.
638       * The back-end could get it from queue size field of VhostUserInflight. */
639      uint16_t desc_num;
640
641      /* The head of list that track the last batch of used descriptors. */
642      uint16_t last_batch_head;
643
644      /* Store the idx value of used ring */
645      uint16_t used_idx;
646
647      /* Used to track the state of each descriptor in descriptor table */
648      DescStateSplit desc[];
649  } QueueRegionSplit;
650
651To track inflight I/O, the queue region should be processed as follows:
652
653When receiving available buffers from the driver:
654
655#. Get the next available head-descriptor index from available ring, ``i``
656
657#. Set ``desc[i].counter`` to the value of global counter
658
659#. Increase global counter by 1
660
661#. Set ``desc[i].inflight`` to 1
662
663When supplying used buffers to the driver:
664
6651. Get corresponding used head-descriptor index, i
666
6672. Set ``desc[i].next`` to ``last_batch_head``
668
6693. Set ``last_batch_head`` to ``i``
670
671#. Steps 1,2,3 may be performed repeatedly if batching is possible
672
673#. Increase the ``idx`` value of used ring by the size of the batch
674
675#. Set the ``inflight`` field of each ``DescStateSplit`` entry in the batch to 0
676
677#. Set ``used_idx`` to the ``idx`` value of used ring
678
679When reconnecting:
680
681#. If the value of ``used_idx`` does not match the ``idx`` value of
682   used ring (means the inflight field of ``DescStateSplit`` entries in
683   last batch may be incorrect),
684
685   a. Subtract the value of ``used_idx`` from the ``idx`` value of
686      used ring to get last batch size of ``DescStateSplit`` entries
687
688   #. Set the ``inflight`` field of each ``DescStateSplit`` entry to 0 in last batch
689      list which starts from ``last_batch_head``
690
691   #. Set ``used_idx`` to the ``idx`` value of used ring
692
693#. Resubmit inflight ``DescStateSplit`` entries in order of their
694   counter value
695
696For packed virtqueue, queue region can be implemented as:
697
698.. code:: c
699
700  typedef struct DescStatePacked {
701      /* Indicate whether this descriptor is inflight or not.
702       * Only available for head-descriptor. */
703      uint8_t inflight;
704
705      /* Padding */
706      uint8_t padding;
707
708      /* Link to the next free entry */
709      uint16_t next;
710
711      /* Link to the last entry of descriptor list.
712       * Only available for head-descriptor. */
713      uint16_t last;
714
715      /* The length of descriptor list.
716       * Only available for head-descriptor. */
717      uint16_t num;
718
719      /* Used to preserve the order of fetching available descriptors.
720       * Only available for head-descriptor. */
721      uint64_t counter;
722
723      /* The buffer id */
724      uint16_t id;
725
726      /* The descriptor flags */
727      uint16_t flags;
728
729      /* The buffer length */
730      uint32_t len;
731
732      /* The buffer address */
733      uint64_t addr;
734  } DescStatePacked;
735
736  typedef struct QueueRegionPacked {
737      /* The feature flags of this region. Now it's initialized to 0. */
738      uint64_t features;
739
740      /* The version of this region. It's 1 currently.
741       * Zero value indicates an uninitialized buffer */
742      uint16_t version;
743
744      /* The size of DescStatePacked array. It's equal to the virtqueue size.
745       * The back-end could get it from queue size field of VhostUserInflight. */
746      uint16_t desc_num;
747
748      /* The head of free DescStatePacked entry list */
749      uint16_t free_head;
750
751      /* The old head of free DescStatePacked entry list */
752      uint16_t old_free_head;
753
754      /* The used index of descriptor ring */
755      uint16_t used_idx;
756
757      /* The old used index of descriptor ring */
758      uint16_t old_used_idx;
759
760      /* Device ring wrap counter */
761      uint8_t used_wrap_counter;
762
763      /* The old device ring wrap counter */
764      uint8_t old_used_wrap_counter;
765
766      /* Padding */
767      uint8_t padding[7];
768
769      /* Used to track the state of each descriptor fetched from descriptor ring */
770      DescStatePacked desc[];
771  } QueueRegionPacked;
772
773To track inflight I/O, the queue region should be processed as follows:
774
775When receiving available buffers from the driver:
776
777#. Get the next available descriptor entry from descriptor ring, ``d``
778
779#. If ``d`` is head descriptor,
780
781   a. Set ``desc[old_free_head].num`` to 0
782
783   #. Set ``desc[old_free_head].counter`` to the value of global counter
784
785   #. Increase global counter by 1
786
787   #. Set ``desc[old_free_head].inflight`` to 1
788
789#. If ``d`` is last descriptor, set ``desc[old_free_head].last`` to
790   ``free_head``
791
792#. Increase ``desc[old_free_head].num`` by 1
793
794#. Set ``desc[free_head].addr``, ``desc[free_head].len``,
795   ``desc[free_head].flags``, ``desc[free_head].id`` to ``d.addr``,
796   ``d.len``, ``d.flags``, ``d.id``
797
798#. Set ``free_head`` to ``desc[free_head].next``
799
800#. If ``d`` is last descriptor, set ``old_free_head`` to ``free_head``
801
802When supplying used buffers to the driver:
803
8041. Get corresponding used head-descriptor entry from descriptor ring,
805   ``d``
806
8072. Get corresponding ``DescStatePacked`` entry, ``e``
808
8093. Set ``desc[e.last].next`` to ``free_head``
810
8114. Set ``free_head`` to the index of ``e``
812
813#. Steps 1,2,3,4 may be performed repeatedly if batching is possible
814
815#. Increase ``used_idx`` by the size of the batch and update
816   ``used_wrap_counter`` if needed
817
818#. Update ``d.flags``
819
820#. Set the ``inflight`` field of each head ``DescStatePacked`` entry
821   in the batch to 0
822
823#. Set ``old_free_head``,  ``old_used_idx``, ``old_used_wrap_counter``
824   to ``free_head``, ``used_idx``, ``used_wrap_counter``
825
826When reconnecting:
827
828#. If ``used_idx`` does not match ``old_used_idx`` (means the
829   ``inflight`` field of ``DescStatePacked`` entries in last batch may
830   be incorrect),
831
832   a. Get the next descriptor ring entry through ``old_used_idx``, ``d``
833
834   #. Use ``old_used_wrap_counter`` to calculate the available flags
835
836   #. If ``d.flags`` is not equal to the calculated flags value (means
837      back-end has submitted the buffer to guest driver before crash, so
838      it has to commit the in-progres update), set ``old_free_head``,
839      ``old_used_idx``, ``old_used_wrap_counter`` to ``free_head``,
840      ``used_idx``, ``used_wrap_counter``
841
842#. Set ``free_head``, ``used_idx``, ``used_wrap_counter`` to
843   ``old_free_head``, ``old_used_idx``, ``old_used_wrap_counter``
844   (roll back any in-progress update)
845
846#. Set the ``inflight`` field of each ``DescStatePacked`` entry in
847   free list to 0
848
849#. Resubmit inflight ``DescStatePacked`` entries in order of their
850   counter value
851
852In-band notifications
853---------------------
854
855In some limited situations (e.g. for simulation) it is desirable to
856have the kick, call and error (if used) signals done via in-band
857messages instead of asynchronous eventfd notifications. This can be
858done by negotiating the ``VHOST_USER_PROTOCOL_F_INBAND_NOTIFICATIONS``
859protocol feature.
860
861Note that due to the fact that too many messages on the sockets can
862cause the sending application(s) to block, it is not advised to use
863this feature unless absolutely necessary. It is also considered an
864error to negotiate this feature without also negotiating
865``VHOST_USER_PROTOCOL_F_BACKEND_REQ`` and ``VHOST_USER_PROTOCOL_F_REPLY_ACK``,
866the former is necessary for getting a message channel from the back-end
867to the front-end, while the latter needs to be used with the in-band
868notification messages to block until they are processed, both to avoid
869blocking later and for proper processing (at least in the simulation
870use case.) As it has no other way of signalling this error, the back-end
871should close the connection as a response to a
872``VHOST_USER_SET_PROTOCOL_FEATURES`` message that sets the in-band
873notifications feature flag without the other two.
874
875Protocol features
876-----------------
877
878.. code:: c
879
880  #define VHOST_USER_PROTOCOL_F_MQ                    0
881  #define VHOST_USER_PROTOCOL_F_LOG_SHMFD             1
882  #define VHOST_USER_PROTOCOL_F_RARP                  2
883  #define VHOST_USER_PROTOCOL_F_REPLY_ACK             3
884  #define VHOST_USER_PROTOCOL_F_MTU                   4
885  #define VHOST_USER_PROTOCOL_F_BACKEND_REQ           5
886  #define VHOST_USER_PROTOCOL_F_CROSS_ENDIAN          6
887  #define VHOST_USER_PROTOCOL_F_CRYPTO_SESSION        7
888  #define VHOST_USER_PROTOCOL_F_PAGEFAULT             8
889  #define VHOST_USER_PROTOCOL_F_CONFIG                9
890  #define VHOST_USER_PROTOCOL_F_BACKEND_SEND_FD      10
891  #define VHOST_USER_PROTOCOL_F_HOST_NOTIFIER        11
892  #define VHOST_USER_PROTOCOL_F_INFLIGHT_SHMFD       12
893  #define VHOST_USER_PROTOCOL_F_RESET_DEVICE         13
894  #define VHOST_USER_PROTOCOL_F_INBAND_NOTIFICATIONS 14
895  #define VHOST_USER_PROTOCOL_F_CONFIGURE_MEM_SLOTS  15
896  #define VHOST_USER_PROTOCOL_F_STATUS               16
897  #define VHOST_USER_PROTOCOL_F_XEN_MMAP             17
898  #define VHOST_USER_PROTOCOL_F_SHARED_OBJECT        18
899
900Front-end message types
901-----------------------
902
903``VHOST_USER_GET_FEATURES``
904  :id: 1
905  :equivalent ioctl: ``VHOST_GET_FEATURES``
906  :request payload: N/A
907  :reply payload: ``u64``
908
909  Get from the underlying vhost implementation the features bitmask.
910  Feature bit ``VHOST_USER_F_PROTOCOL_FEATURES`` signals back-end support
911  for ``VHOST_USER_GET_PROTOCOL_FEATURES`` and
912  ``VHOST_USER_SET_PROTOCOL_FEATURES``.
913
914``VHOST_USER_SET_FEATURES``
915  :id: 2
916  :equivalent ioctl: ``VHOST_SET_FEATURES``
917  :request payload: ``u64``
918  :reply payload: N/A
919
920  Enable features in the underlying vhost implementation using a
921  bitmask.  Feature bit ``VHOST_USER_F_PROTOCOL_FEATURES`` signals
922  back-end support for ``VHOST_USER_GET_PROTOCOL_FEATURES`` and
923  ``VHOST_USER_SET_PROTOCOL_FEATURES``.
924
925``VHOST_USER_GET_PROTOCOL_FEATURES``
926  :id: 15
927  :equivalent ioctl: ``VHOST_GET_FEATURES``
928  :request payload: N/A
929  :reply payload: ``u64``
930
931  Get the protocol feature bitmask from the underlying vhost
932  implementation.  Only legal if feature bit
933  ``VHOST_USER_F_PROTOCOL_FEATURES`` is present in
934  ``VHOST_USER_GET_FEATURES``.  It does not need to be acknowledged by
935  ``VHOST_USER_SET_FEATURES``.
936
937.. Note::
938   Back-ends that report ``VHOST_USER_F_PROTOCOL_FEATURES`` must
939   support this message even before ``VHOST_USER_SET_FEATURES`` was
940   called.
941
942``VHOST_USER_SET_PROTOCOL_FEATURES``
943  :id: 16
944  :equivalent ioctl: ``VHOST_SET_FEATURES``
945  :request payload: ``u64``
946  :reply payload: N/A
947
948  Enable protocol features in the underlying vhost implementation.
949
950  Only legal if feature bit ``VHOST_USER_F_PROTOCOL_FEATURES`` is present in
951  ``VHOST_USER_GET_FEATURES``.  It does not need to be acknowledged by
952  ``VHOST_USER_SET_FEATURES``.
953
954.. Note::
955   Back-ends that report ``VHOST_USER_F_PROTOCOL_FEATURES`` must support
956   this message even before ``VHOST_USER_SET_FEATURES`` was called.
957
958``VHOST_USER_SET_OWNER``
959  :id: 3
960  :equivalent ioctl: ``VHOST_SET_OWNER``
961  :request payload: N/A
962  :reply payload: N/A
963
964  Issued when a new connection is established. It marks the sender
965  as the front-end that owns of the session. This can be used on the *back-end*
966  as a "session start" flag.
967
968``VHOST_USER_RESET_OWNER``
969  :id: 4
970  :request payload: N/A
971  :reply payload: N/A
972
973.. admonition:: Deprecated
974
975   This is no longer used. Used to be sent to request disabling all
976   rings, but some back-ends interpreted it to also discard connection
977   state (this interpretation would lead to bugs).  It is recommended
978   that back-ends either ignore this message, or use it to disable all
979   rings.
980
981``VHOST_USER_SET_MEM_TABLE``
982  :id: 5
983  :equivalent ioctl: ``VHOST_SET_MEM_TABLE``
984  :request payload: multiple memory regions description
985  :reply payload: (postcopy only) multiple memory regions description
986
987  Sets the memory map regions on the back-end so it can translate the
988  vring addresses. In the ancillary data there is an array of file
989  descriptors for each memory mapped region. The size and ordering of
990  the fds matches the number and ordering of memory regions.
991
992  When ``VHOST_USER_POSTCOPY_LISTEN`` has been received,
993  ``SET_MEM_TABLE`` replies with the bases of the memory mapped
994  regions to the front-end.  The back-end must have mmap'd the regions but
995  not yet accessed them and should not yet generate a userfault
996  event.
997
998.. Note::
999   ``NEED_REPLY_MASK`` is not set in this case.  QEMU will then
1000   reply back to the list of mappings with an empty
1001   ``VHOST_USER_SET_MEM_TABLE`` as an acknowledgement; only upon
1002   reception of this message may the guest start accessing the memory
1003   and generating faults.
1004
1005``VHOST_USER_SET_LOG_BASE``
1006  :id: 6
1007  :equivalent ioctl: ``VHOST_SET_LOG_BASE``
1008  :request payload: u64
1009  :reply payload: N/A
1010
1011  Sets logging shared memory space.
1012
1013  When the back-end has ``VHOST_USER_PROTOCOL_F_LOG_SHMFD`` protocol feature,
1014  the log memory fd is provided in the ancillary data of
1015  ``VHOST_USER_SET_LOG_BASE`` message, the size and offset of shared
1016  memory area provided in the message.
1017
1018``VHOST_USER_SET_LOG_FD``
1019  :id: 7
1020  :equivalent ioctl: ``VHOST_SET_LOG_FD``
1021  :request payload: N/A
1022  :reply payload: N/A
1023
1024  Sets the logging file descriptor, which is passed as ancillary data.
1025
1026``VHOST_USER_SET_VRING_NUM``
1027  :id: 8
1028  :equivalent ioctl: ``VHOST_SET_VRING_NUM``
1029  :request payload: vring state description
1030  :reply payload: N/A
1031
1032  Set the size of the queue.
1033
1034``VHOST_USER_SET_VRING_ADDR``
1035  :id: 9
1036  :equivalent ioctl: ``VHOST_SET_VRING_ADDR``
1037  :request payload: vring address description
1038  :reply payload: N/A
1039
1040  Sets the addresses of the different aspects of the vring.
1041
1042``VHOST_USER_SET_VRING_BASE``
1043  :id: 10
1044  :equivalent ioctl: ``VHOST_SET_VRING_BASE``
1045  :request payload: vring state description
1046  :reply payload: N/A
1047
1048  Sets the base offset in the available vring.
1049
1050``VHOST_USER_GET_VRING_BASE``
1051  :id: 11
1052  :equivalent ioctl: ``VHOST_USER_GET_VRING_BASE``
1053  :request payload: vring state description
1054  :reply payload: vring state description
1055
1056  Get the available vring base offset.
1057
1058``VHOST_USER_SET_VRING_KICK``
1059  :id: 12
1060  :equivalent ioctl: ``VHOST_SET_VRING_KICK``
1061  :request payload: ``u64``
1062  :reply payload: N/A
1063
1064  Set the event file descriptor for adding buffers to the vring. It is
1065  passed in the ancillary data.
1066
1067  Bits (0-7) of the payload contain the vring index. Bit 8 is the
1068  invalid FD flag. This flag is set when there is no file descriptor
1069  in the ancillary data. This signals that polling should be used
1070  instead of waiting for the kick. Note that if the protocol feature
1071  ``VHOST_USER_PROTOCOL_F_INBAND_NOTIFICATIONS`` has been negotiated
1072  this message isn't necessary as the ring is also started on the
1073  ``VHOST_USER_VRING_KICK`` message, it may however still be used to
1074  set an event file descriptor (which will be preferred over the
1075  message) or to enable polling.
1076
1077``VHOST_USER_SET_VRING_CALL``
1078  :id: 13
1079  :equivalent ioctl: ``VHOST_SET_VRING_CALL``
1080  :request payload: ``u64``
1081  :reply payload: N/A
1082
1083  Set the event file descriptor to signal when buffers are used. It is
1084  passed in the ancillary data.
1085
1086  Bits (0-7) of the payload contain the vring index. Bit 8 is the
1087  invalid FD flag. This flag is set when there is no file descriptor
1088  in the ancillary data. This signals that polling will be used
1089  instead of waiting for the call. Note that if the protocol features
1090  ``VHOST_USER_PROTOCOL_F_INBAND_NOTIFICATIONS`` and
1091  ``VHOST_USER_PROTOCOL_F_BACKEND_REQ`` have been negotiated this message
1092  isn't necessary as the ``VHOST_USER_BACKEND_VRING_CALL`` message can be
1093  used, it may however still be used to set an event file descriptor
1094  or to enable polling.
1095
1096``VHOST_USER_SET_VRING_ERR``
1097  :id: 14
1098  :equivalent ioctl: ``VHOST_SET_VRING_ERR``
1099  :request payload: ``u64``
1100  :reply payload: N/A
1101
1102  Set the event file descriptor to signal when error occurs. It is
1103  passed in the ancillary data.
1104
1105  Bits (0-7) of the payload contain the vring index. Bit 8 is the
1106  invalid FD flag. This flag is set when there is no file descriptor
1107  in the ancillary data. Note that if the protocol features
1108  ``VHOST_USER_PROTOCOL_F_INBAND_NOTIFICATIONS`` and
1109  ``VHOST_USER_PROTOCOL_F_BACKEND_REQ`` have been negotiated this message
1110  isn't necessary as the ``VHOST_USER_BACKEND_VRING_ERR`` message can be
1111  used, it may however still be used to set an event file descriptor
1112  (which will be preferred over the message).
1113
1114``VHOST_USER_GET_QUEUE_NUM``
1115  :id: 17
1116  :equivalent ioctl: N/A
1117  :request payload: N/A
1118  :reply payload: u64
1119
1120  Query how many queues the back-end supports.
1121
1122  This request should be sent only when ``VHOST_USER_PROTOCOL_F_MQ``
1123  is set in queried protocol features by
1124  ``VHOST_USER_GET_PROTOCOL_FEATURES``.
1125
1126``VHOST_USER_SET_VRING_ENABLE``
1127  :id: 18
1128  :equivalent ioctl: N/A
1129  :request payload: vring state description
1130  :reply payload: N/A
1131
1132  Signal the back-end to enable or disable corresponding vring.
1133
1134  This request should be sent only when
1135  ``VHOST_USER_F_PROTOCOL_FEATURES`` has been negotiated.
1136
1137``VHOST_USER_SEND_RARP``
1138  :id: 19
1139  :equivalent ioctl: N/A
1140  :request payload: ``u64``
1141  :reply payload: N/A
1142
1143  Ask vhost user back-end to broadcast a fake RARP to notify the migration
1144  is terminated for guest that does not support GUEST_ANNOUNCE.
1145
1146  Only legal if feature bit ``VHOST_USER_F_PROTOCOL_FEATURES`` is
1147  present in ``VHOST_USER_GET_FEATURES`` and protocol feature bit
1148  ``VHOST_USER_PROTOCOL_F_RARP`` is present in
1149  ``VHOST_USER_GET_PROTOCOL_FEATURES``.  The first 6 bytes of the
1150  payload contain the mac address of the guest to allow the vhost user
1151  back-end to construct and broadcast the fake RARP.
1152
1153``VHOST_USER_NET_SET_MTU``
1154  :id: 20
1155  :equivalent ioctl: N/A
1156  :request payload: ``u64``
1157  :reply payload: N/A
1158
1159  Set host MTU value exposed to the guest.
1160
1161  This request should be sent only when ``VIRTIO_NET_F_MTU`` feature
1162  has been successfully negotiated, ``VHOST_USER_F_PROTOCOL_FEATURES``
1163  is present in ``VHOST_USER_GET_FEATURES`` and protocol feature bit
1164  ``VHOST_USER_PROTOCOL_F_NET_MTU`` is present in
1165  ``VHOST_USER_GET_PROTOCOL_FEATURES``.
1166
1167  If ``VHOST_USER_PROTOCOL_F_REPLY_ACK`` is negotiated, the back-end must
1168  respond with zero in case the specified MTU is valid, or non-zero
1169  otherwise.
1170
1171``VHOST_USER_SET_BACKEND_REQ_FD`` (previous name ``VHOST_USER_SET_SLAVE_REQ_FD``)
1172  :id: 21
1173  :equivalent ioctl: N/A
1174  :request payload: N/A
1175  :reply payload: N/A
1176
1177  Set the socket file descriptor for back-end initiated requests. It is passed
1178  in the ancillary data.
1179
1180  This request should be sent only when
1181  ``VHOST_USER_F_PROTOCOL_FEATURES`` has been negotiated, and protocol
1182  feature bit ``VHOST_USER_PROTOCOL_F_BACKEND_REQ`` bit is present in
1183  ``VHOST_USER_GET_PROTOCOL_FEATURES``.  If
1184  ``VHOST_USER_PROTOCOL_F_REPLY_ACK`` is negotiated, the back-end must
1185  respond with zero for success, non-zero otherwise.
1186
1187``VHOST_USER_IOTLB_MSG``
1188  :id: 22
1189  :equivalent ioctl: N/A (equivalent to ``VHOST_IOTLB_MSG`` message type)
1190  :request payload: ``struct vhost_iotlb_msg``
1191  :reply payload: ``u64``
1192
1193  Send IOTLB messages with ``struct vhost_iotlb_msg`` as payload.
1194
1195  The front-end sends such requests to update and invalidate entries in the
1196  device IOTLB. The back-end has to acknowledge the request with sending
1197  zero as ``u64`` payload for success, non-zero otherwise.
1198
1199  This request should be send only when ``VIRTIO_F_IOMMU_PLATFORM``
1200  feature has been successfully negotiated.
1201
1202``VHOST_USER_SET_VRING_ENDIAN``
1203  :id: 23
1204  :equivalent ioctl: ``VHOST_SET_VRING_ENDIAN``
1205  :request payload: vring state description
1206  :reply payload: N/A
1207
1208  Set the endianness of a VQ for legacy devices. Little-endian is
1209  indicated with state.num set to 0 and big-endian is indicated with
1210  state.num set to 1. Other values are invalid.
1211
1212  This request should be sent only when
1213  ``VHOST_USER_PROTOCOL_F_CROSS_ENDIAN`` has been negotiated.
1214  Backends that negotiated this feature should handle both
1215  endiannesses and expect this message once (per VQ) during device
1216  configuration (ie. before the front-end starts the VQ).
1217
1218``VHOST_USER_GET_CONFIG``
1219  :id: 24
1220  :equivalent ioctl: N/A
1221  :request payload: virtio device config space
1222  :reply payload: virtio device config space
1223
1224  When ``VHOST_USER_PROTOCOL_F_CONFIG`` is negotiated, this message is
1225  submitted by the vhost-user front-end to fetch the contents of the
1226  virtio device configuration space, vhost-user back-end's payload size
1227  MUST match the front-end's request, vhost-user back-end uses zero length of
1228  payload to indicate an error to the vhost-user front-end. The vhost-user
1229  front-end may cache the contents to avoid repeated
1230  ``VHOST_USER_GET_CONFIG`` calls.
1231
1232``VHOST_USER_SET_CONFIG``
1233  :id: 25
1234  :equivalent ioctl: N/A
1235  :request payload: virtio device config space
1236  :reply payload: N/A
1237
1238  When ``VHOST_USER_PROTOCOL_F_CONFIG`` is negotiated, this message is
1239  submitted by the vhost-user front-end when the Guest changes the virtio
1240  device configuration space and also can be used for live migration
1241  on the destination host. The vhost-user back-end must check the flags
1242  field, and back-ends MUST NOT accept SET_CONFIG for read-only
1243  configuration space fields unless the live migration bit is set.
1244
1245``VHOST_USER_CREATE_CRYPTO_SESSION``
1246  :id: 26
1247  :equivalent ioctl: N/A
1248  :request payload: crypto session description
1249  :reply payload: crypto session description
1250
1251  Create a session for crypto operation. The back-end must return
1252  the session id, 0 or positive for success, negative for failure.
1253  This request should be sent only when
1254  ``VHOST_USER_PROTOCOL_F_CRYPTO_SESSION`` feature has been
1255  successfully negotiated.  It's a required feature for crypto
1256  devices.
1257
1258``VHOST_USER_CLOSE_CRYPTO_SESSION``
1259  :id: 27
1260  :equivalent ioctl: N/A
1261  :request payload: ``u64``
1262  :reply payload: N/A
1263
1264  Close a session for crypto operation which was previously
1265  created by ``VHOST_USER_CREATE_CRYPTO_SESSION``.
1266
1267  This request should be sent only when
1268  ``VHOST_USER_PROTOCOL_F_CRYPTO_SESSION`` feature has been
1269  successfully negotiated.  It's a required feature for crypto
1270  devices.
1271
1272``VHOST_USER_POSTCOPY_ADVISE``
1273  :id: 28
1274  :request payload: N/A
1275  :reply payload: userfault fd
1276
1277  When ``VHOST_USER_PROTOCOL_F_PAGEFAULT`` is supported, the front-end
1278  advises back-end that a migration with postcopy enabled is underway,
1279  the back-end must open a userfaultfd for later use.  Note that at this
1280  stage the migration is still in precopy mode.
1281
1282``VHOST_USER_POSTCOPY_LISTEN``
1283  :id: 29
1284  :request payload: N/A
1285  :reply payload: N/A
1286
1287  The front-end advises back-end that a transition to postcopy mode has
1288  happened.  The back-end must ensure that shared memory is registered
1289  with userfaultfd to cause faulting of non-present pages.
1290
1291  This is always sent sometime after a ``VHOST_USER_POSTCOPY_ADVISE``,
1292  and thus only when ``VHOST_USER_PROTOCOL_F_PAGEFAULT`` is supported.
1293
1294``VHOST_USER_POSTCOPY_END``
1295  :id: 30
1296  :request payload: N/A
1297  :reply payload: ``u64``
1298
1299  The front-end advises that postcopy migration has now completed.  The back-end
1300  must disable the userfaultfd. The reply is an acknowledgement
1301  only.
1302
1303  When ``VHOST_USER_PROTOCOL_F_PAGEFAULT`` is supported, this message
1304  is sent at the end of the migration, after
1305  ``VHOST_USER_POSTCOPY_LISTEN`` was previously sent.
1306
1307  The value returned is an error indication; 0 is success.
1308
1309``VHOST_USER_GET_INFLIGHT_FD``
1310  :id: 31
1311  :equivalent ioctl: N/A
1312  :request payload: inflight description
1313  :reply payload: N/A
1314
1315  When ``VHOST_USER_PROTOCOL_F_INFLIGHT_SHMFD`` protocol feature has
1316  been successfully negotiated, this message is submitted by the front-end to
1317  get a shared buffer from back-end. The shared buffer will be used to
1318  track inflight I/O by back-end. QEMU should retrieve a new one when vm
1319  reset.
1320
1321``VHOST_USER_SET_INFLIGHT_FD``
1322  :id: 32
1323  :equivalent ioctl: N/A
1324  :request payload: inflight description
1325  :reply payload: N/A
1326
1327  When ``VHOST_USER_PROTOCOL_F_INFLIGHT_SHMFD`` protocol feature has
1328  been successfully negotiated, this message is submitted by the front-end to
1329  send the shared inflight buffer back to the back-end so that the back-end
1330  could get inflight I/O after a crash or restart.
1331
1332``VHOST_USER_GPU_SET_SOCKET``
1333  :id: 33
1334  :equivalent ioctl: N/A
1335  :request payload: N/A
1336  :reply payload: N/A
1337
1338  Sets the GPU protocol socket file descriptor, which is passed as
1339  ancillary data. The GPU protocol is used to inform the front-end of
1340  rendering state and updates. See vhost-user-gpu.rst for details.
1341
1342``VHOST_USER_RESET_DEVICE``
1343  :id: 34
1344  :equivalent ioctl: N/A
1345  :request payload: N/A
1346  :reply payload: N/A
1347
1348  Ask the vhost user back-end to disable all rings and reset all
1349  internal device state to the initial state, ready to be
1350  reinitialized. The back-end retains ownership of the device
1351  throughout the reset operation.
1352
1353  Only valid if the ``VHOST_USER_PROTOCOL_F_RESET_DEVICE`` protocol
1354  feature is set by the back-end.
1355
1356``VHOST_USER_VRING_KICK``
1357  :id: 35
1358  :equivalent ioctl: N/A
1359  :request payload: vring state description
1360  :reply payload: N/A
1361
1362  When the ``VHOST_USER_PROTOCOL_F_INBAND_NOTIFICATIONS`` protocol
1363  feature has been successfully negotiated, this message may be
1364  submitted by the front-end to indicate that a buffer was added to
1365  the vring instead of signalling it using the vring's kick file
1366  descriptor or having the back-end rely on polling.
1367
1368  The state.num field is currently reserved and must be set to 0.
1369
1370``VHOST_USER_GET_MAX_MEM_SLOTS``
1371  :id: 36
1372  :equivalent ioctl: N/A
1373  :request payload: N/A
1374  :reply payload: u64
1375
1376  When the ``VHOST_USER_PROTOCOL_F_CONFIGURE_MEM_SLOTS`` protocol
1377  feature has been successfully negotiated, this message is submitted
1378  by the front-end to the back-end. The back-end should return the message with a
1379  u64 payload containing the maximum number of memory slots for
1380  QEMU to expose to the guest. The value returned by the back-end
1381  will be capped at the maximum number of ram slots which can be
1382  supported by the target platform.
1383
1384``VHOST_USER_ADD_MEM_REG``
1385  :id: 37
1386  :equivalent ioctl: N/A
1387  :request payload: N/A
1388  :reply payload: single memory region description
1389
1390  When the ``VHOST_USER_PROTOCOL_F_CONFIGURE_MEM_SLOTS`` protocol
1391  feature has been successfully negotiated, this message is submitted
1392  by the front-end to the back-end. The message payload contains a memory
1393  region descriptor struct, describing a region of guest memory which
1394  the back-end device must map in. When the
1395  ``VHOST_USER_PROTOCOL_F_CONFIGURE_MEM_SLOTS`` protocol feature has
1396  been successfully negotiated, along with the
1397  ``VHOST_USER_REM_MEM_REG`` message, this message is used to set and
1398  update the memory tables of the back-end device.
1399
1400  Exactly one file descriptor from which the memory is mapped is
1401  passed in the ancillary data.
1402
1403  In postcopy mode (see ``VHOST_USER_POSTCOPY_LISTEN``), the back-end
1404  replies with the bases of the memory mapped region to the front-end.
1405  For further details on postcopy, see ``VHOST_USER_SET_MEM_TABLE``.
1406  They apply to ``VHOST_USER_ADD_MEM_REG`` accordingly.
1407
1408``VHOST_USER_REM_MEM_REG``
1409  :id: 38
1410  :equivalent ioctl: N/A
1411  :request payload: N/A
1412  :reply payload: single memory region description
1413
1414  When the ``VHOST_USER_PROTOCOL_F_CONFIGURE_MEM_SLOTS`` protocol
1415  feature has been successfully negotiated, this message is submitted
1416  by the front-end to the back-end. The message payload contains a memory
1417  region descriptor struct, describing a region of guest memory which
1418  the back-end device must unmap. When the
1419  ``VHOST_USER_PROTOCOL_F_CONFIGURE_MEM_SLOTS`` protocol feature has
1420  been successfully negotiated, along with the
1421  ``VHOST_USER_ADD_MEM_REG`` message, this message is used to set and
1422  update the memory tables of the back-end device.
1423
1424  The memory region to be removed is identified by its guest address,
1425  user address and size. The mmap offset is ignored.
1426
1427  No file descriptors SHOULD be passed in the ancillary data. For
1428  compatibility with existing incorrect implementations, the back-end MAY
1429  accept messages with one file descriptor. If a file descriptor is
1430  passed, the back-end MUST close it without using it otherwise.
1431
1432``VHOST_USER_SET_STATUS``
1433  :id: 39
1434  :equivalent ioctl: VHOST_VDPA_SET_STATUS
1435  :request payload: ``u64``
1436  :reply payload: N/A
1437
1438  When the ``VHOST_USER_PROTOCOL_F_STATUS`` protocol feature has been
1439  successfully negotiated, this message is submitted by the front-end to
1440  notify the back-end with updated device status as defined in the Virtio
1441  specification.
1442
1443``VHOST_USER_GET_STATUS``
1444  :id: 40
1445  :equivalent ioctl: VHOST_VDPA_GET_STATUS
1446  :request payload: N/A
1447  :reply payload: ``u64``
1448
1449  When the ``VHOST_USER_PROTOCOL_F_STATUS`` protocol feature has been
1450  successfully negotiated, this message is submitted by the front-end to
1451  query the back-end for its device status as defined in the Virtio
1452  specification.
1453
1454``VHOST_USER_GET_SHARED_OBJECT``
1455  :id: 41
1456  :equivalent ioctl: N/A
1457  :request payload: ``struct VhostUserShared``
1458  :reply payload: dmabuf fd
1459
1460  When the ``VHOST_USER_PROTOCOL_F_SHARED_OBJECT`` protocol
1461  feature has been successfully negotiated, and the UUID is found
1462  in the exporters cache, this message is submitted by the front-end
1463  to retrieve a given dma-buf fd from a given back-end, determined by
1464  the requested UUID. Back-end will reply passing the fd when the operation
1465  is successful, or no fd otherwise.
1466
1467Back-end message types
1468----------------------
1469
1470For this type of message, the request is sent by the back-end and the reply
1471is sent by the front-end.
1472
1473``VHOST_USER_BACKEND_IOTLB_MSG`` (previous name ``VHOST_USER_SLAVE_IOTLB_MSG``)
1474  :id: 1
1475  :equivalent ioctl: N/A (equivalent to ``VHOST_IOTLB_MSG`` message type)
1476  :request payload: ``struct vhost_iotlb_msg``
1477  :reply payload: N/A
1478
1479  Send IOTLB messages with ``struct vhost_iotlb_msg`` as payload.
1480  The back-end sends such requests to notify of an IOTLB miss, or an IOTLB
1481  access failure. If ``VHOST_USER_PROTOCOL_F_REPLY_ACK`` is
1482  negotiated, and back-end set the ``VHOST_USER_NEED_REPLY`` flag, the front-end
1483  must respond with zero when operation is successfully completed, or
1484  non-zero otherwise.  This request should be send only when
1485  ``VIRTIO_F_IOMMU_PLATFORM`` feature has been successfully
1486  negotiated.
1487
1488``VHOST_USER_BACKEND_CONFIG_CHANGE_MSG`` (previous name ``VHOST_USER_SLAVE_CONFIG_CHANGE_MSG``)
1489  :id: 2
1490  :equivalent ioctl: N/A
1491  :request payload: N/A
1492  :reply payload: N/A
1493
1494  When ``VHOST_USER_PROTOCOL_F_CONFIG`` is negotiated, vhost-user
1495  back-end sends such messages to notify that the virtio device's
1496  configuration space has changed, for those host devices which can
1497  support such feature, host driver can send ``VHOST_USER_GET_CONFIG``
1498  message to the back-end to get the latest content. If
1499  ``VHOST_USER_PROTOCOL_F_REPLY_ACK`` is negotiated, and the back-end sets the
1500  ``VHOST_USER_NEED_REPLY`` flag, the front-end must respond with zero when
1501  operation is successfully completed, or non-zero otherwise.
1502
1503``VHOST_USER_BACKEND_VRING_HOST_NOTIFIER_MSG`` (previous name ``VHOST_USER_SLAVE_VRING_HOST_NOTIFIER_MSG``)
1504  :id: 3
1505  :equivalent ioctl: N/A
1506  :request payload: vring area description
1507  :reply payload: N/A
1508
1509  Sets host notifier for a specified queue. The queue index is
1510  contained in the ``u64`` field of the vring area description. The
1511  host notifier is described by the file descriptor (typically it's a
1512  VFIO device fd) which is passed as ancillary data and the size
1513  (which is mmap size and should be the same as host page size) and
1514  offset (which is mmap offset) carried in the vring area
1515  description. QEMU can mmap the file descriptor based on the size and
1516  offset to get a memory range. Registering a host notifier means
1517  mapping this memory range to the VM as the specified queue's notify
1518  MMIO region. The back-end sends this request to tell QEMU to de-register
1519  the existing notifier if any and register the new notifier if the
1520  request is sent with a file descriptor.
1521
1522  This request should be sent only when
1523  ``VHOST_USER_PROTOCOL_F_HOST_NOTIFIER`` protocol feature has been
1524  successfully negotiated.
1525
1526``VHOST_USER_BACKEND_VRING_CALL`` (previous name ``VHOST_USER_SLAVE_VRING_CALL``)
1527  :id: 4
1528  :equivalent ioctl: N/A
1529  :request payload: vring state description
1530  :reply payload: N/A
1531
1532  When the ``VHOST_USER_PROTOCOL_F_INBAND_NOTIFICATIONS`` protocol
1533  feature has been successfully negotiated, this message may be
1534  submitted by the back-end to indicate that a buffer was used from
1535  the vring instead of signalling this using the vring's call file
1536  descriptor or having the front-end relying on polling.
1537
1538  The state.num field is currently reserved and must be set to 0.
1539
1540``VHOST_USER_BACKEND_VRING_ERR`` (previous name ``VHOST_USER_SLAVE_VRING_ERR``)
1541  :id: 5
1542  :equivalent ioctl: N/A
1543  :request payload: vring state description
1544  :reply payload: N/A
1545
1546  When the ``VHOST_USER_PROTOCOL_F_INBAND_NOTIFICATIONS`` protocol
1547  feature has been successfully negotiated, this message may be
1548  submitted by the back-end to indicate that an error occurred on the
1549  specific vring, instead of signalling the error file descriptor
1550  set by the front-end via ``VHOST_USER_SET_VRING_ERR``.
1551
1552  The state.num field is currently reserved and must be set to 0.
1553
1554``VHOST_USER_BACKEND_SHARED_OBJECT_ADD``
1555  :id: 6
1556  :equivalent ioctl: N/A
1557  :request payload: ``struct VhostUserShared``
1558  :reply payload: N/A
1559
1560  When the ``VHOST_USER_PROTOCOL_F_SHARED_OBJECT`` protocol
1561  feature has been successfully negotiated, this message can be submitted
1562  by the backends to add themselves as exporters to the virtio shared lookup
1563  table. The back-end device gets associated with a UUID in the shared table.
1564  The back-end is responsible of keeping its own table with exported dma-buf fds.
1565  When another back-end tries to import the resource associated with the UUID,
1566  it will send a message to the front-end, which will act as a proxy to the
1567  exporter back-end. If ``VHOST_USER_PROTOCOL_F_REPLY_ACK`` is negotiated, and
1568  the back-end sets the ``VHOST_USER_NEED_REPLY`` flag, the front-end must
1569  respond with zero when operation is successfully completed, or non-zero
1570  otherwise.
1571
1572``VHOST_USER_BACKEND_SHARED_OBJECT_REMOVE``
1573  :id: 7
1574  :equivalent ioctl: N/A
1575  :request payload: ``struct VhostUserShared``
1576  :reply payload: N/A
1577
1578  When the ``VHOST_USER_PROTOCOL_F_SHARED_OBJECT`` protocol
1579  feature has been successfully negotiated, this message can be submitted
1580  by the backend to remove themselves from to the virtio-dmabuf shared
1581  table API. The shared table will remove the back-end device associated with
1582  the UUID. If ``VHOST_USER_PROTOCOL_F_REPLY_ACK`` is negotiated, and the
1583  back-end sets the ``VHOST_USER_NEED_REPLY`` flag, the front-end must respond
1584  with zero when operation is successfully completed, or non-zero otherwise.
1585
1586``VHOST_USER_BACKEND_SHARED_OBJECT_LOOKUP``
1587  :id: 8
1588  :equivalent ioctl: N/A
1589  :request payload: ``struct VhostUserShared``
1590  :reply payload: dmabuf fd and ``u64``
1591
1592  When the ``VHOST_USER_PROTOCOL_F_SHARED_OBJECT`` protocol
1593  feature has been successfully negotiated, this message can be submitted
1594  by the backends to retrieve a given dma-buf fd from the virtio-dmabuf
1595  shared table given a UUID. Frontend will reply passing the fd and a zero
1596  when the operation is successful, or non-zero otherwise. Note that if the
1597  operation fails, no fd is sent to the backend.
1598
1599.. _reply_ack:
1600
1601VHOST_USER_PROTOCOL_F_REPLY_ACK
1602-------------------------------
1603
1604The original vhost-user specification only demands replies for certain
1605commands. This differs from the vhost protocol implementation where
1606commands are sent over an ``ioctl()`` call and block until the back-end
1607has completed.
1608
1609With this protocol extension negotiated, the sender (QEMU) can set the
1610``need_reply`` [Bit 3] flag to any command. This indicates that the
1611back-end MUST respond with a Payload ``VhostUserMsg`` indicating success
1612or failure. The payload should be set to zero on success or non-zero
1613on failure, unless the message already has an explicit reply body.
1614
1615The reply payload gives QEMU a deterministic indication of the result
1616of the command. Today, QEMU is expected to terminate the main vhost-user
1617loop upon receiving such errors. In future, qemu could be taught to be more
1618resilient for selective requests.
1619
1620For the message types that already solicit a reply from the back-end,
1621the presence of ``VHOST_USER_PROTOCOL_F_REPLY_ACK`` or need_reply bit
1622being set brings no behavioural change. (See the Communication_
1623section for details.)
1624
1625.. _backend_conventions:
1626
1627Backend program conventions
1628===========================
1629
1630vhost-user back-ends can provide various devices & services and may
1631need to be configured manually depending on the use case. However, it
1632is a good idea to follow the conventions listed here when
1633possible. Users, QEMU or libvirt, can then rely on some common
1634behaviour to avoid heterogeneous configuration and management of the
1635back-end programs and facilitate interoperability.
1636
1637Each back-end installed on a host system should come with at least one
1638JSON file that conforms to the vhost-user.json schema. Each file
1639informs the management applications about the back-end type, and binary
1640location. In addition, it defines rules for management apps for
1641picking the highest priority back-end when multiple match the search
1642criteria (see ``@VhostUserBackend`` documentation in the schema file).
1643
1644If the back-end is not capable of enabling a requested feature on the
1645host (such as 3D acceleration with virgl), or the initialization
1646failed, the back-end should fail to start early and exit with a status
1647!= 0. It may also print a message to stderr for further details.
1648
1649The back-end program must not daemonize itself, but it may be
1650daemonized by the management layer. It may also have a restricted
1651access to the system.
1652
1653File descriptors 0, 1 and 2 will exist, and have regular
1654stdin/stdout/stderr usage (they may have been redirected to /dev/null
1655by the management layer, or to a log handler).
1656
1657The back-end program must end (as quickly and cleanly as possible) when
1658the SIGTERM signal is received. Eventually, it may receive SIGKILL by
1659the management layer after a few seconds.
1660
1661The following command line options have an expected behaviour. They
1662are mandatory, unless explicitly said differently:
1663
1664--socket-path=PATH
1665
1666  This option specify the location of the vhost-user Unix domain socket.
1667  It is incompatible with --fd.
1668
1669--fd=FDNUM
1670
1671  When this argument is given, the back-end program is started with the
1672  vhost-user socket as file descriptor FDNUM. It is incompatible with
1673  --socket-path.
1674
1675--print-capabilities
1676
1677  Output to stdout the back-end capabilities in JSON format, and then
1678  exit successfully. Other options and arguments should be ignored, and
1679  the back-end program should not perform its normal function.  The
1680  capabilities can be reported dynamically depending on the host
1681  capabilities.
1682
1683The JSON output is described in the ``vhost-user.json`` schema, by
1684```@VHostUserBackendCapabilities``.  Example:
1685
1686.. code:: json
1687
1688  {
1689    "type": "foo",
1690    "features": [
1691      "feature-a",
1692      "feature-b"
1693    ]
1694  }
1695
1696vhost-user-input
1697----------------
1698
1699Command line options:
1700
1701--evdev-path=PATH
1702
1703  Specify the linux input device.
1704
1705  (optional)
1706
1707--no-grab
1708
1709  Do no request exclusive access to the input device.
1710
1711  (optional)
1712
1713vhost-user-gpu
1714--------------
1715
1716Command line options:
1717
1718--render-node=PATH
1719
1720  Specify the GPU DRM render node.
1721
1722  (optional)
1723
1724--virgl
1725
1726  Enable virgl rendering support.
1727
1728  (optional)
1729
1730vhost-user-blk
1731--------------
1732
1733Command line options:
1734
1735--blk-file=PATH
1736
1737  Specify block device or file path.
1738
1739  (optional)
1740
1741--read-only
1742
1743  Enable read-only.
1744
1745  (optional)