3Found UPS at /dev/usb/hiddev0
4hiddev driver version is 1.0.2
5HID: vendor 0x51d product 0x2 version 0x6 app UPS
6HID: bus: 2 devnum: 2 ifnum: 0
7UPS HID device name: "American Power Conversion Back-UPS CS 650 FW:817.v4.I USB FW:v4"
8Battery Chemistry: "PbAc" (4)
9
10InputReport 12
11  Field 0, app UPS, phys ---
12Exponent 0 lost.
13    Usage 0, RemainingCapacity = 100 percent
14
15InputReport 13
16  Field 0, app UPS, phys ---
17    Usage 0, RunTimeToEmpty = 1462 Seconds
18
19InputReport 7
20  Field 0, app UPS, phys ---
21    Usage 0, Charging = 0
22  Field 1, app UPS, phys ---
23    Usage 0, Discharging = 0
24  Field 2, app UPS, phys ---
25    Usage 0, ACPresent = 1
26  Field 3, app UPS, phys ---
27    Usage 0, BatteryPresent = 1
28  Field 4, app UPS, phys ---
29    Usage 0, BelowRemainingCapacityLimit = 0
30  Field 5, app UPS, phys ---
31    Usage 0, ShutdownRequested = 0
32  Field 6, app UPS, phys ---
33    Usage 0, ShutdownImminent = 0
34  Field 7, app UPS, phys ---
35    Usage 0, RemainingTimeLimitExpired = 0
36  Field 8, app UPS, phys ---
37    Usage 0, CommunicationLost = 0
38  Field 9, app UPS, phys ---
39    Usage 0, NeedReplacement = 0
40  Field 10, app UPS, phys ---
41    Usage 0, Overload = 0
42  Field 11, app UPS, phys ---
43    Usage 0, VoltageNotRegulated = 0
44  Field 12, app UPS, phys ---
45    Usage 0, [ff860080] = 0
46
47InputReport 22
48  Field 0, app UPS, phys Battery
49    Usage 0, Test = 6
50
51InputReport 51
52  Field 0, app UPS, phys ---
53    Usage 0, Charging = 0
54  Field 1, app UPS, phys ---
55    Usage 0, Discharging = 0
56  Field 2, app UPS, phys ---
57    Usage 0, ACPresent = 1
58  Field 3, app UPS, phys ---
59    Usage 0, BatteryPresent = 1
60  Field 4, app UPS, phys ---
61    Usage 0, BelowRemainingCapacityLimit = 0
62  Field 5, app UPS, phys ---
63    Usage 0, ShutdownRequested = 0
64  Field 6, app UPS, phys ---
65    Usage 0, ShutdownImminent = 0
66  Field 7, app UPS, phys ---
67    Usage 0, RemainingTimeLimitExpired = 0
68  Field 8, app UPS, phys ---
69    Usage 0, CommunicationLost = 0
70  Field 9, app UPS, phys ---
71    Usage 0, NeedReplacement = 0
72  Field 10, app UPS, phys ---
73    Usage 0, Overload = 0
74  Field 11, app UPS, phys ---
75    Usage 0, VoltageNotRegulated = 0
76  Field 12, app UPS, phys ---
77    Usage 0, [ff860080] = 0
78
79FeatureReport 1
80  Field 0, app UPS, phys ---
81    Usage 0, iProduct = 1  Back-UPS CS 650 FW:817.v4.I USB FW:v4
82
83FeatureReport 2
84  Field 0, app UPS, phys ---
85    Usage 0, iSerialNumber = 2  QB0642232674
86
87FeatureReport 3
88  Field 0, app UPS, phys ---
89    Usage 0, iManufacturer = 3  American Power Conversion
90
91FeatureReport 4
92  Field 0, app UPS, phys ---
93    Usage 0, iOEMInformation = 3  American Power Conversion
94
95FeatureReport 5
96  Field 0, app UPS, phys ---
97    Usage 0, iDeviceChemistry = 4  PbAc
98
99FeatureReport 6
100  Field 0, app UPS, phys ---
101    Usage 0, Rechargeable = 1
102  Field 1, app UPS, phys ---
103Exponent 0 lost.
104    Usage 0, CapacityMode = 2 percent
105
106FeatureReport 14
107  Field 0, app UPS, phys ---
108Exponent 2 lost.
109    Usage 0, DesignCapacity = 100 percent
110  Field 1, app UPS, phys ---
111Exponent 2 lost.
112    Usage 0, FullChargeCapacity = 100 percent
113
114FeatureReport 12
115  Field 0, app UPS, phys ---
116Exponent 2 lost.
117    Usage 0, RemainingCapacity = 100 percent
118
119FeatureReport 16
120  Field 0, app UPS, phys ---
121Exponent 2 lost.
122    Usage 0, CapacityGranularity1 = 1 percent
123  Field 1, app UPS, phys ---
124Exponent 2 lost.
125    Usage 0, CapacityGranularity2 = 1 percent
126
127FeatureReport 15
128  Field 0, app UPS, phys ---
129Exponent 2 lost.
130    Usage 0, WarningCapacityLimit = 50 percent
131
132FeatureReport 17
133  Field 0, app UPS, phys ---
134Exponent 2 lost.
135    Usage 0, RemainingCapacityLimit = 10 percent
136
137FeatureReport 9
138  Field 0, app UPS, phys ---
139    Usage 0, ManufactureDate = 13644  2006-10-12
140
141FeatureReport 13
142  Field 0, app UPS, phys ---
143    Usage 0, RunTimeToEmpty = 1530 Seconds
144
145FeatureReport 18
146  Field 0, app UPS, phys ---
147    Usage 0, DelayBeforeShutdown = -1
148
149FeatureReport 19
150  Field 0, app UPS, phys ---
151    Usage 0, DelayBeforeReboot = 0 Seconds
152
153FeatureReport 8
154  Field 0, app UPS, phys ---
155    Usage 0, RemainingTimeLimit = 120 Seconds
156
157FeatureReport 10
158  Field 0, app UPS, phys ---
159    Usage 0, ConfigVoltage = 1200 CentiVolts
160
161FeatureReport 11
162  Field 0, app UPS, phys ---
163    Usage 0, Voltage = 1351 CentiVolts
164
165FeatureReport 20
166  Field 0, app UPS, phys ---
167    Usage 0, AudibleAlarmControl = 1
168
169FeatureReport 7
170  Field 0, app UPS, phys ---
171    Usage 0, Charging = 0
172  Field 1, app UPS, phys ---
173    Usage 0, Discharging = 0
174  Field 2, app UPS, phys ---
175    Usage 0, ACPresent = 1
176  Field 3, app UPS, phys ---
177    Usage 0, BatteryPresent = 1
178  Field 4, app UPS, phys ---
179    Usage 0, BelowRemainingCapacityLimit = 0
180  Field 5, app UPS, phys ---
181    Usage 0, ShutdownRequested = 0
182  Field 6, app UPS, phys ---
183    Usage 0, ShutdownImminent = 0
184  Field 7, app UPS, phys ---
185    Usage 0, RemainingTimeLimitExpired = 0
186  Field 8, app UPS, phys ---
187    Usage 0, CommunicationLost = 0
188  Field 9, app UPS, phys ---
189    Usage 0, NeedReplacement = 0
190  Field 10, app UPS, phys ---
191    Usage 0, Overload = 0
192  Field 11, app UPS, phys ---
193    Usage 0, VoltageNotRegulated = 0
194  Field 12, app UPS, phys ---
195    Usage 0, [ff860080] = 0
196
197FeatureReport 22
198  Field 0, app UPS, phys Battery
199    Usage 0, Test = 6
200
201FeatureReport 23
202  Field 0, app UPS, phys Battery
203    Usage 0, APCBattCapBeforeStartup = 0
204
205FeatureReport 27
206  Field 0, app UPS, phys Battery
207    Usage 0, [ff86001a] = 0
208
209FeatureReport 28
210  Field 0, app UPS, phys Battery
211    Usage 0, [ff86001b] = 0
212
213FeatureReport 69
214  Field 0, app UPS, phys Battery
215    Usage 0, APCBattReplacementDate = 1053190  2006-10-12
216
217
218FeatureReport 21
219  Field 0, app UPS, phys Battery
220    Usage 0, ManufactureDate = 13644  2006-10-12
221
222FeatureReport 24
223  Field 0, app UPS, phys Battery
224Exponent 0 lost.
225    Usage 0, RemainingCapacity = 1000 percent
226
227FeatureReport 26
228  Field 0, app UPS, phys Battery
229    Usage 0, RemainingTimeLimit = 120 Seconds
230
231FeatureReport 25
232  Field 0, app UPS, phys Battery
233    Usage 0, RunTimeToEmpty = 1507 Seconds
234
235FeatureReport 30
236  Field 0, app UPS, phys Battery
237    Usage 0, Temperature = 3023 Degrees K with -1 exponent
238
239FeatureReport 31
240  Field 0, app UPS, phys Battery
241    Usage 0, ConfigVoltage = 1200 CentiVolts
242
243FeatureReport 29
244  Field 0, app UPS, phys Battery
245    Usage 0, Voltage = 1351 CentiVolts
246
247FeatureReport 71
248  Field 0, app UPS, phys Battery
249    Usage 0, APC860024_?????? = 240
250
251FeatureReport 72
252  Field 0, app UPS, phys Battery
253    Usage 0, [ff860018] = 0
254
255FeatureReport 32
256  Field 0, app UPS, phys Input
257    Usage 0, Voltage = 0 DeciVolts
258
259FeatureReport 70
260  Field 0, app UPS, phys Input
261    Usage 0, ConfigVoltage = 230 Volts
262
263FeatureReport 33
264  Field 0, app UPS, phys Input
265    Usage 0, APCLineFailCause = 12
266
267FeatureReport 34
268  Field 0, app UPS, phys Input
269    Usage 0, APC860061_?????? = 1
270
271FeatureReport 66
272  Field 0, app UPS, phys Input
273    Usage 0, APC860024_?????? = 126
274
275FeatureReport 44
276  Field 0, app UPS, phys Output
277    Usage 0, PercentLoad = 250
278
279FeatureReport 82
280  Field 0, app UPS, phys Output
281    Usage 0, ConfigActivePower = 400 Watts
282
283FeatureReport 42
284  Field 0, app UPS, phys Output
285    Usage 0, Frequency = 5000 CentiHertz
286
287FeatureReport 43
288  Field 0, app UPS, phys Output
289    Usage 0, Voltage = 2300 DeciVolts
290
291FeatureReport 45
292  Field 0, app UPS, phys Output
293    Usage 0, ConfigVoltage = 0 Volts
294
295FeatureReport 35
296  Field 0, app UPS, phys Output
297    Usage 0, HighVoltageTransfer = 260 Volts
298
299FeatureReport 36
300  Field 0, app UPS, phys Output
301    Usage 0, LowVoltageTransfer = 0 Volts
302
303FeatureReport 37
304  Field 0, app UPS, phys Output
305    Usage 0, APCDelayBeforeStartup = 0 Seconds
306
307FeatureReport 38
308  Field 0, app UPS, phys Output
309    Usage 0, APCShutdownAfterDelay = 0 Seconds
310
311FeatureReport 39
312  Field 0, app UPS, phys Output
313    Usage 0, DelayBeforeShutdown = -1
314
315FeatureReport 40
316  Field 0, app UPS, phys Output
317    Usage 0, DelayBeforeStartup = 0 Seconds
318
319FeatureReport 41
320  Field 0, app UPS, phys Output
321    Usage 0, DelayBeforeReboot = 0 Seconds
322
323FeatureReport 64
324  Field 0, app UPS, phys Output
325    Usage 0, APCForceShutdown = 0
326
327FeatureReport 65
328  Field 0, app UPS, phys Output
329    Usage 0, APCDelayBeforeShutdown = -1 Seconds
330
331FeatureReport 46
332  Field 0, app UPS, phys ---
333    Usage 0, iProduct = 5  Back-UPS CS 650
334
335FeatureReport 47
336  Field 0, app UPS, phys ---
337    Usage 0, iSerialNumber = 2  QB0642232674
338
339FeatureReport 48
340  Field 0, app UPS, phys ---
341    Usage 0, iManufacturer = 3  American Power Conversion
342
343FeatureReport 49
344  Field 0, app UPS, phys ---
345    Usage 0, iName = 6  APC
346
347FeatureReport 52
348  Field 0, app UPS, phys ---
349    Usage 0, APC_UPS_FirmwareRevision = 7
350
351FeatureReport 55
352  Field 0, app UPS, phys ---
353    Usage 0, APC_USB_FirmwareRevision = 8
354
355FeatureReport 50
356  Field 0, app UPS, phys ---
357    Usage 0, APCPanelTest = 0
358
359FeatureReport 53
360  Field 0, app UPS, phys ---
361    Usage 0, ManufactureDate = 13644  2006-10-12
362
363FeatureReport 62
364  Field 0, app UPS, phys ---
365    Usage 0, [ff860027] = 0
366
367FeatureReport 63
368  Field 0, app UPS, phys ---
369    Usage 0, [ff860028] = 0
370
371FeatureReport 54
372  Field 0, app UPS, phys ---
373    Usage 0, AudibleAlarmControl = 1
374
375FeatureReport 51
376  Field 0, app UPS, phys ---
377    Usage 0, Charging = 0
378  Field 1, app UPS, phys ---
379    Usage 0, Discharging = 0
380  Field 2, app UPS, phys ---
381    Usage 0, ACPresent = 1
382  Field 3, app UPS, phys ---
383    Usage 0, BatteryPresent = 1
384  Field 4, app UPS, phys ---
385    Usage 0, BelowRemainingCapacityLimit = 0
386  Field 5, app UPS, phys ---
387    Usage 0, ShutdownRequested = 0
388  Field 6, app UPS, phys ---
389    Usage 0, ShutdownImminent = 0
390  Field 7, app UPS, phys ---
391    Usage 0, RemainingTimeLimitExpired = 0
392  Field 8, app UPS, phys ---
393    Usage 0, CommunicationLost = 0
394  Field 9, app UPS, phys ---
395    Usage 0, NeedReplacement = 0
396  Field 10, app UPS, phys ---
397    Usage 0, Overload = 0
398  Field 11, app UPS, phys ---
399    Usage 0, VoltageNotRegulated = 0
400  Field 12, app UPS, phys ---
401    Usage 0, [ff860080] = 0
402
403FeatureReport 96
404  Field 0, app UPS, phys [ff860001]
405    Usage 0, APC860023_?????? = 0
406
407FeatureReport 97
408  Field 0, app UPS, phys [ff860001]
409    Usage 0, APC860026_?????? = 14
410
411FeatureReport 98
412  Field 0, app UPS, phys [ff860001]
413    Usage 0, APC860025_?????? = 0
414
415FeatureReport 81
416  Field 0, app UPS, phys PowerConverter
417    Usage 0, APC860024_?????? = 148
418
419Waiting for events ... (interrupt to exit)
420Event: RunTimeToEmpty = 1507
421Event: RunTimeToEmpty = 1507
422Event: RunTimeToEmpty = 1485
423Event: RunTimeToEmpty = 1462
424Event: RunTimeToEmpty = 1485
425Event: RunTimeToEmpty = 1507
426Event: RunTimeToEmpty = 1530
427Event: RunTimeToEmpty = 1507
428Event: RunTimeToEmpty = 1530