1-- This file is corresponding to Release 9.1.10.101 from 2014/08/11 00:00:00 2 3 4-- (C)opyright 1991-2014 bintec elmeg GmbH, All Rights Reserved 5-- $RCSfile: mibsysx8,v $ 6-- $Revision: 1.8 $ 7 8BIANCA-X8000-MIBSYS-MIB DEFINITIONS ::= BEGIN 9 10 IMPORTS 11 Counter, enterprises 12 FROM RFC1155-SMI 13 14 DisplayString 15 FROM RFC1158-MIB 16 17 TRAP-TYPE 18 FROM RFC-1215 19 20 OBJECT-TYPE 21 FROM RFC-1212; 22 23 bintec OBJECT IDENTIFIER ::= { enterprises 272 } 24 bibo OBJECT IDENTIFIER ::= { bintec 4 } 25 sys OBJECT IDENTIFIER ::= { bibo 17 } 26 x8 OBJECT IDENTIFIER ::= { sys 3 } 27 sysX8Config OBJECT IDENTIFIER 28 ::= { x8 1 } 29 30 sysX8Traps OBJECT IDENTIFIER ::= { x8 2 } 31 32-- System Status and Configuration 33 34 sysX8ConfigPowerSupply1State OBJECT-TYPE 35 SYNTAX INTEGER { missing(1), off(2), running(3), fail(4) } 36 ACCESS read-only 37 STATUS mandatory 38 39 DESCRIPTION 40 "This variable shows the state of the power supply." 41 ::= { sysX8Config 1 } 42 43 sysX8ConfigPowerSupply1Temp OBJECT-TYPE 44 SYNTAX INTEGER (0..250) 45 ACCESS read-only 46 STATUS mandatory 47 48 DESCRIPTION 49 "This variable shows the actual power supply temperature 50 in the unit Celsius." 51 ::= { sysX8Config 2 } 52 53 sysX8ConfigPowerSupply1TempAlarmThreshold OBJECT-TYPE 54 SYNTAX INTEGER (0..250) 55 ACCESS read-write 56 STATUS mandatory 57 58 DESCRIPTION 59 "Power supply 1 temperature threshold." 60 DEFVAL { 40 } 61 ::= { sysX8Config 3 } 62 63 sysX8ConfigPowerSupply1TempAlarmTrap OBJECT-TYPE 64 SYNTAX INTEGER { normal(1), critical(2) } 65 ACCESS read-only 66 STATUS mandatory 67 68 DESCRIPTION 69 "If the power supply temperature raises above the threshold, 70 a alarm trap is generated every 60 seconds." 71 ::= { sysX8Config 4 } 72 73 sysX8ConfigPowerSupply2State OBJECT-TYPE 74 SYNTAX INTEGER { missing(1), off(2), running(3), fail(4) } 75 ACCESS read-only 76 STATUS mandatory 77 78 DESCRIPTION 79 "This variable show the the state of the power supply." 80 ::= { sysX8Config 5 } 81 82 sysX8ConfigPowerSupply2Temp OBJECT-TYPE 83 SYNTAX INTEGER (0..250) 84 ACCESS read-only 85 STATUS mandatory 86 87 DESCRIPTION 88 "This variable shows the actual power supply temperature 89 in the unit Celsius." 90 ::= { sysX8Config 6 } 91 92 sysX8ConfigPowerSupply2TempAlarmThreshold OBJECT-TYPE 93 SYNTAX INTEGER (0..250) 94 ACCESS read-write 95 STATUS mandatory 96 97 DESCRIPTION 98 "Power supply 2 temperature threshold." 99 DEFVAL { 40 } 100 ::= { sysX8Config 7 } 101 102 sysX8ConfigPowerSupply2TempAlarmTrap OBJECT-TYPE 103 SYNTAX INTEGER { normal(1), critical(2) } 104 ACCESS read-only 105 STATUS mandatory 106 107 DESCRIPTION 108 "If the power supply temperature raises above the threshold, 109 a alarm trap is generated every 60 seconds." 110 ::= { sysX8Config 8 } 111 112 sysX8ConfigFanControl OBJECT-TYPE 113 SYNTAX INTEGER { auto(1), high(2) } 114 ACCESS read-write 115 STATUS mandatory 116 DESCRIPTION 117 "This variable defines automatic fan control. 118 In mode 'auto' the fans are automatically adjusted 119 depending on the current temperature. 120 In mode 'high' all fans remain at maximum speed." 121 DEFVAL { high } 122 ::= { sysX8Config 9 } 123 124 sysX8ConfigFanVersion OBJECT-TYPE 125 SYNTAX DisplayString 126 ACCESS read-only 127 STATUS mandatory 128 129 DESCRIPTION 130 "This variable shows the firmware version of 131 the fan unit." 132 ::= { sysX8Config 10 } 133 134 sysX8ConfigFan1 OBJECT-TYPE 135 SYNTAX INTEGER 136 ACCESS read-only 137 STATUS mandatory 138 139 DESCRIPTION 140 "This variable shows the current turning speed." 141 ::= { sysX8Config 11 } 142 143 sysX8ConfigFan2 OBJECT-TYPE 144 SYNTAX INTEGER 145 ACCESS read-only 146 STATUS mandatory 147 148 DESCRIPTION 149 "This variable shows the current turning speed." 150 ::= { sysX8Config 12 } 151 152 sysX8ConfigFan3 OBJECT-TYPE 153 SYNTAX INTEGER 154 ACCESS read-only 155 STATUS mandatory 156 157 DESCRIPTION 158 "This variable shows the current turning speed." 159 ::= { sysX8Config 13 } 160 161 sysX8ConfigFan4 OBJECT-TYPE 162 SYNTAX INTEGER 163 ACCESS read-only 164 STATUS mandatory 165 166 DESCRIPTION 167 "This variable shows the current turning speed." 168 ::= { sysX8Config 14 } 169 170--- 171--- System Status and Configuration Traps 172--- 173 174 sysX8TrapPowerSupply1Missing TRAP-TYPE 175 ENTERPRISE sysX8Traps 176 VARIABLES { 177 sysDescr, 178 sysName, 179 sysX8ConfigPowerSupply1State, 180 sysX8ConfigPowerSupply1Temp, 181 sysX8ConfigPowerSupply1TempAlarmTrap 182 } 183 DESCRIPTION "This trap signifies that the power supply 1 184 has been removed" 185 ::= 1 186 187 sysX8TrapPowerSupply1PowerOff TRAP-TYPE 188 ENTERPRISE sysX8Traps 189 VARIABLES { 190 sysDescr, 191 sysName, 192 sysX8ConfigPowerSupply1State, 193 sysX8ConfigPowerSupply1Temp, 194 sysX8ConfigPowerSupply1TempAlarmTrap 195 } 196 DESCRIPTION "This trap signifies that the power supply 1 197 has no power-good signal (no power input)" 198 ::= 2 199 200 sysX8TrapPowerSupply1PowerFail TRAP-TYPE 201 ENTERPRISE sysX8Traps 202 VARIABLES { 203 sysDescr, 204 sysName, 205 sysX8ConfigPowerSupply1State, 206 sysX8ConfigPowerSupply1Temp, 207 sysX8ConfigPowerSupply1TempAlarmTrap 208 } 209 DESCRIPTION "This trap signifies that the power supply 1 210 has been in the failure (bad DC output)" 211 ::= 3 212 213 sysX8TrapPowerSupply1PowerGood TRAP-TYPE 214 ENTERPRISE sysX8Traps 215 VARIABLES { 216 sysDescr, 217 sysName, 218 sysX8ConfigPowerSupply1State, 219 sysX8ConfigPowerSupply1Temp, 220 sysX8ConfigPowerSupply1TempAlarmTrap 221 } 222 DESCRIPTION "This trap signifies that the power supply 1 223 is running (supplying power)" 224 ::= 4 225 226 sysX8TrapPowerSupply1TempCritical TRAP-TYPE 227 ENTERPRISE sysX8Traps 228 VARIABLES { 229 sysDescr, 230 sysName, 231 sysX8ConfigPowerSupply1State, 232 sysX8ConfigPowerSupply1Temp, 233 sysX8ConfigPowerSupply1TempAlarmThreshold 234 } 235 DESCRIPTION "This trap signifies that the power supply 1 temperature 236 raises above the critical alarm-threshold" 237 ::= 5 238 239 sysX8TrapPowerSupply1TempOk TRAP-TYPE 240 ENTERPRISE sysX8Traps 241 VARIABLES { 242 sysDescr, 243 sysName, 244 sysX8ConfigPowerSupply1State, 245 sysX8ConfigPowerSupply1Temp, 246 sysX8ConfigPowerSupply1TempAlarmThreshold 247 } 248 DESCRIPTION "A normal power supply 1 temperature has been restored." 249 ::= 6 250 251 sysX8TrapPowerSupply2Missing TRAP-TYPE 252 ENTERPRISE sysX8Traps 253 VARIABLES { 254 sysDescr, 255 sysName, 256 sysX8ConfigPowerSupply2State, 257 sysX8ConfigPowerSupply2Temp, 258 sysX8ConfigPowerSupply2TempAlarmThreshold 259 } 260 DESCRIPTION "This trap signifies that the power supply 2 261 has been removed" 262 ::= 7 263 264 sysX8TrapPowerSupply2PowerOff TRAP-TYPE 265 ENTERPRISE sysX8Traps 266 VARIABLES { 267 sysDescr, 268 sysName, 269 sysX8ConfigPowerSupply2State, 270 sysX8ConfigPowerSupply2Temp, 271 sysX8ConfigPowerSupply2TempAlarmThreshold 272 } 273 DESCRIPTION "This trap signifies that the power supply 2 274 has no power-good signal (no power input)" 275 ::= 8 276 277 sysX8TrapPowerSupply2PowerFail TRAP-TYPE 278 ENTERPRISE sysX8Traps 279 VARIABLES { 280 sysDescr, 281 sysName, 282 sysX8ConfigPowerSupply2State, 283 sysX8ConfigPowerSupply2Temp, 284 sysX8ConfigPowerSupply2TempAlarmThreshold 285 } 286 DESCRIPTION "This trap signifies that the power supply 2 287 has been in the failure (bad DC output)" 288 ::= 9 289 290 sysX8TrapPowerSupply2PowerGood TRAP-TYPE 291 ENTERPRISE sysX8Traps 292 VARIABLES { 293 sysDescr, 294 sysName, 295 sysX8ConfigPowerSupply2State, 296 sysX8ConfigPowerSupply2Temp, 297 sysX8ConfigPowerSupply2TempAlarmThreshold 298 } 299 DESCRIPTION "This trap signifies that the power supply 2 300 is running (supplying power)" 301 ::= 10 302 303 sysX8TrapPowerSupply2TempCritical TRAP-TYPE 304 ENTERPRISE sysX8Traps 305 VARIABLES { 306 sysDescr, 307 sysName, 308 sysX8ConfigPowerSupply2State, 309 sysX8ConfigPowerSupply2Temp, 310 sysX8ConfigPowerSupply2TempAlarmThreshold 311 } 312 DESCRIPTION "This trap signifies that the power supply 2 temperature 313 raises above the critical alarm-threshold" 314 ::= 11 315 316 sysX8TrapPowerSupply2TempOk TRAP-TYPE 317 ENTERPRISE sysX8Traps 318 VARIABLES { 319 sysDescr, 320 sysName, 321 sysX8ConfigPowerSupply2State, 322 sysX8ConfigPowerSupply2Temp, 323 sysX8ConfigPowerSupply2TempAlarmThreshold 324 } 325 DESCRIPTION "A normal power supply 2 temperature has been restored." 326 ::= 12 327 328END 329