1Found UPS at /dev/usb/hid/hiddev0 2hiddev driver version is 1.0.2 3HID: vendor 0x51d product 0x2 version 0x6 app UPS 4HID: bus: 2 devnum: 2 ifnum: 0 5UPS HID device name: "American Power Conversion Smart-UPS 1000 FW:600.1.I USB FW:1.2" 6Battery Chemistry: "PbAc" (4) 7 8InputReport 12 9 Field 0, app UPS, phys --- 10 Usage 0, RemainingCapacity = 100 percent 11 12InputReport 8 13 Field 0, app UPS, phys --- 14 Usage 0, RemainingTimeLimit = 0 Seconds 15 16InputReport 20 17 Field 0, app UPS, phys --- 18 Usage 0, AudibleAlarmControl = 2 19 20InputReport 7 21 Field 0, app UPS, phys --- 22 Usage 0, Charging = 0 23 Field 1, app UPS, phys --- 24 Usage 0, Discharging = 0 25 Field 2, app UPS, phys --- 26 Usage 0, ACPresent = 1 27 Field 3, app UPS, phys --- 28 Usage 0, BatteryPresent = 1 29 Field 4, app UPS, phys --- 30 Usage 0, BelowRemainingCapacityLimit = 0 31 Field 5, app UPS, phys --- 32 Usage 0, ShutdownRequested = 0 33 Field 6, app UPS, phys --- 34 Usage 0, ShutdownImminent = 0 35 Field 7, app UPS, phys --- 36 Usage 0, RemainingTimeLimitExpired = 0 37 Field 8, app UPS, phys --- 38 Usage 0, CommunicationLost = 0 39 Field 9, app UPS, phys --- 40 Usage 0, NeedReplacement = 0 41 Field 10, app UPS, phys --- 42 Usage 0, Overload = 0 43 Field 11, app UPS, phys --- 44 Usage 0, VoltageNotRegulated = 0 45 Field 12, app UPS, phys --- 46 Usage 0, [ff860080] = 0 47 48InputReport 22 49 Field 0, app UPS, phys Battery 50 Usage 0, Test = 6 51 52InputReport 23 53 Field 0, app UPS, phys Battery 54 Usage 0, [ff860019] = 0 55 56InputReport 27 57 Field 0, app UPS, phys Battery 58 Usage 0, [ff86001a] = 3 59 60InputReport 28 61 Field 0, app UPS, phys Battery 62 Usage 0, [ff86001b] = 0 63 64InputReport 21 65 Field 0, app UPS, phys Battery 66 Usage 0, ManufactureDate = 11032 2001-08-24 67 68InputReport 26 69 Field 0, app UPS, phys Battery 70 Usage 0, RemainingTimeLimit = 120 71 72InputReport 33 73 Field 0, app UPS, phys Input 74 Usage 0, [ff860052] = 0 75 76InputReport 34 77 Field 0, app UPS, phys Input 78 Usage 0, [ff860061] = 2 79 80InputReport 45 81 Field 0, app UPS, phys Output 82 Usage 0, ConfigVoltage = 230 Volts 83 84InputReport 35 85 Field 0, app UPS, phys Output 86 Usage 0, HighVoltageTransfer = 253 Volts 87 88InputReport 36 89 Field 0, app UPS, phys Output 90 Usage 0, LowVoltageTransfer = 208 Volts 91 92InputReport 37 93 Field 0, app UPS, phys Output 94 Usage 0, [ff86007e] = 0 95 96InputReport 38 97 Field 0, app UPS, phys Output 98 Usage 0, APCShutdownAfterDelay = 90 99 100InputReport 54 101 Field 0, app UPS, phys --- 102 Usage 0, AudibleAlarmControl = 2 103 104InputReport 51 105 Field 0, app UPS, phys --- 106 Usage 0, Charging = 0 107 Field 1, app UPS, phys --- 108 Usage 0, Discharging = 0 109 Field 2, app UPS, phys --- 110 Usage 0, ACPresent = 1 111 Field 3, app UPS, phys --- 112 Usage 0, BatteryPresent = 1 113 Field 4, app UPS, phys --- 114 Usage 0, BelowRemainingCapacityLimit = 0 115 Field 5, app UPS, phys --- 116 Usage 0, ShutdownRequested = 0 117 Field 6, app UPS, phys --- 118 Usage 0, ShutdownImminent = 0 119 Field 7, app UPS, phys --- 120 Usage 0, RemainingTimeLimitExpired = 0 121 Field 8, app UPS, phys --- 122 Usage 0, CommunicationLost = 0 123 Field 9, app UPS, phys --- 124 Usage 0, NeedReplacement = 0 125 Field 10, app UPS, phys --- 126 Usage 0, Overload = 0 127 Field 11, app UPS, phys --- 128 Usage 0, VoltageNotRegulated = 0 129 Field 12, app UPS, phys --- 130 Usage 0, [ff860080] = 0 131 132FeatureReport 1 133 Field 0, app UPS, phys --- 134 Usage 0, iProduct = 1 Smart-UPS 1000 FW:600.1.I USB FW:1.2 135 136FeatureReport 2 137 Field 0, app UPS, phys --- 138 Usage 0, iSerialNumber = 2 AS0134132215 139 140FeatureReport 3 141 Field 0, app UPS, phys --- 142 Usage 0, iManufacturer = 3 American Power Conversion 143 144FeatureReport 4 145 Field 0, app UPS, phys --- 146 Usage 0, iOEMInformation = 3 American Power Conversion 147 148FeatureReport 5 149 Field 0, app UPS, phys --- 150 Usage 0, iDeviceChemistry = 4 PbAc 151 152FeatureReport 6 153 Field 0, app UPS, phys --- 154 Usage 0, Rechargeable = 1 155 Field 1, app UPS, phys --- 156 Usage 0, CapacityMode = 2 percent 157 158FeatureReport 14 159 Field 0, app UPS, phys --- 160 Usage 0, DesignCapacity = 100 percent 161 Field 1, app UPS, phys --- 162 Usage 0, FullChargeCapacity = 100 percent 163 164FeatureReport 12 165 Field 0, app UPS, phys --- 166 Usage 0, RemainingCapacity = 100 percent 167 168FeatureReport 16 169 Field 0, app UPS, phys --- 170 Usage 0, CapacityGranularity1 = 1 percent 171 Field 1, app UPS, phys --- 172 Usage 0, CapacityGranularity2 = 1 percent 173 174FeatureReport 15 175 Field 0, app UPS, phys --- 176 Usage 0, WarningCapacityLimit = 50 percent 177 178FeatureReport 17 179 Field 0, app UPS, phys --- 180 Usage 0, RemainingCapacityLimit = 10 percent 181 182FeatureReport 9 183 Field 0, app UPS, phys --- 184 Usage 0, ManufactureDate = 11032 2001-08-24 185 186FeatureReport 13 187 Field 0, app UPS, phys --- 188 Usage 0, RunTimeToEmpty = 21000 Seconds 189 190FeatureReport 18 191 Field 0, app UPS, phys --- 192 Usage 0, DelayBeforeShutdown = -1 193 194FeatureReport 19 195 Field 0, app UPS, phys --- 196 Usage 0, DelayBeforeReboot = -1 Seconds 197 198FeatureReport 8 199 Field 0, app UPS, phys --- 200 Usage 0, RemainingTimeLimit = 0 Seconds 201 202FeatureReport 10 203 Field 0, app UPS, phys --- 204 Usage 0, ConfigVoltage = 2400 CentiVolts 205 206FeatureReport 11 207 Field 0, app UPS, phys --- 208 Usage 0, Voltage = 2754 CentiVolts 209 210FeatureReport 20 211 Field 0, app UPS, phys --- 212 Usage 0, AudibleAlarmControl = 2 213 214FeatureReport 7 215 Field 0, app UPS, phys --- 216 Usage 0, Charging = 0 217 Field 1, app UPS, phys --- 218 Usage 0, Discharging = 0 219 Field 2, app UPS, phys --- 220 Usage 0, ACPresent = 1 221 Field 3, app UPS, phys --- 222 Usage 0, BatteryPresent = 1 223 Field 4, app UPS, phys --- 224 Usage 0, BelowRemainingCapacityLimit = 0 225 Field 5, app UPS, phys --- 226 Usage 0, ShutdownRequested = 0 227 Field 6, app UPS, phys --- 228 Usage 0, ShutdownImminent = 0 229 Field 7, app UPS, phys --- 230 Usage 0, RemainingTimeLimitExpired = 0 231 Field 8, app UPS, phys --- 232 Usage 0, CommunicationLost = 0 233 Field 9, app UPS, phys --- 234 Usage 0, NeedReplacement = 0 235 Field 10, app UPS, phys --- 236 Usage 0, Overload = 0 237 Field 11, app UPS, phys --- 238 Usage 0, VoltageNotRegulated = 0 239 Field 12, app UPS, phys --- 240 Usage 0, [ff860080] = 0 241 242FeatureReport 22 243 Field 0, app UPS, phys Battery 244 Usage 0, Test = 6 245 246FeatureReport 23 247 Field 0, app UPS, phys Battery 248 Usage 0, [ff860019] = 0 249 250FeatureReport 27 251 Field 0, app UPS, phys Battery 252 Usage 0, [ff86001a] = 3 253 254FeatureReport 28 255 Field 0, app UPS, phys Battery 256 Usage 0, [ff86001b] = 0 257 258FeatureReport 21 259 Field 0, app UPS, phys Battery 260 Usage 0, ManufactureDate = 11032 2001-08-24 261 262FeatureReport 24 263 Field 0, app UPS, phys Battery 264 Usage 0, RemainingCapacity = 1000 percent 265 266FeatureReport 26 267 Field 0, app UPS, phys Battery 268 Usage 0, RemainingTimeLimit = 120 269 270FeatureReport 25 271 Field 0, app UPS, phys Battery 272 Usage 0, RunTimeToEmpty = 21000 273 274FeatureReport 30 275 Field 0, app UPS, phys Battery 276 Usage 0, Temperature = 3001 Degrees K with -1 exponent 277 278FeatureReport 31 279 Field 0, app UPS, phys Battery 280 Usage 0, ConfigVoltage = 2400 CentiVolts 281 282FeatureReport 29 283 Field 0, app UPS, phys Battery 284 Usage 0, Voltage = 2754 CentiVolts 285 286FeatureReport 32 287 Field 0, app UPS, phys Input 288 Usage 0, Voltage = 2304 DeciVolts 289 290FeatureReport 33 291 Field 0, app UPS, phys Input 292 Usage 0, [ff860052] = 0 293 294FeatureReport 34 295 Field 0, app UPS, phys Input 296 Usage 0, [ff860061] = 2 297 298FeatureReport 44 299 Field 0, app UPS, phys Output 300 Usage 0, PercentLoad = 0 301 302FeatureReport 42 303 Field 0, app UPS, phys Output 304 Usage 0, Frequency = 5000 CentiHertz 305 306FeatureReport 43 307 Field 0, app UPS, phys Output 308 Usage 0, Voltage = 2304 DeciVolts 309 310FeatureReport 45 311 Field 0, app UPS, phys Output 312 Usage 0, ConfigVoltage = 230 Volts 313 314FeatureReport 35 315 Field 0, app UPS, phys Output 316 Usage 0, HighVoltageTransfer = 253 Volts 317 318FeatureReport 36 319 Field 0, app UPS, phys Output 320 Usage 0, LowVoltageTransfer = 208 Volts 321 322FeatureReport 37 323 Field 0, app UPS, phys Output 324 Usage 0, [ff86007e] = 0 325 326FeatureReport 38 327 Field 0, app UPS, phys Output 328 Usage 0, APCShutdownAfterDelay = 90 329 330FeatureReport 39 331 Field 0, app UPS, phys Output 332 Usage 0, DelayBeforeShutdown = -1 333 334FeatureReport 40 335 Field 0, app UPS, phys Output 336 Usage 0, DelayBeforeStartup = -1 Seconds 337 338FeatureReport 41 339 Field 0, app UPS, phys Output 340 Usage 0, DelayBeforeReboot = -1 Seconds 341 342FeatureReport 46 343 Field 0, app UPS, phys --- 344 Usage 0, iProduct = 5 Smart-UPS 1000 345 346FeatureReport 47 347 Field 0, app UPS, phys --- 348 Usage 0, iSerialNumber = 2 AS0134132215 349 350FeatureReport 48 351 Field 0, app UPS, phys --- 352 Usage 0, iManufacturer = 3 American Power Conversion 353 354FeatureReport 49 355 Field 0, app UPS, phys --- 356 Usage 0, iName = 6 UPSIDEN 357 358FeatureReport 52 359 Field 0, app UPS, phys --- 360 Usage 0, APC_UPS_FirmwareRevision = 7 361 362FeatureReport 55 363 Field 0, app UPS, phys --- 364 Usage 0, APC_USB_FirmwareRevision = 8 365 366FeatureReport 50 367 Field 0, app UPS, phys --- 368 Usage 0, APCPanelTest = 1 369 370FeatureReport 53 371 Field 0, app UPS, phys --- 372 Usage 0, ManufactureDate = 11032 2001-08-24 373 374FeatureReport 62 375 Field 0, app UPS, phys --- 376 Usage 0, [ff860027] = 0 377 378FeatureReport 63 379 Field 0, app UPS, phys --- 380 Usage 0, [ff860028] = 0 381 382FeatureReport 54 383 Field 0, app UPS, phys --- 384 Usage 0, AudibleAlarmControl = 2 385 386FeatureReport 51 387 Field 0, app UPS, phys --- 388 Usage 0, Charging = 0 389 Field 1, app UPS, phys --- 390 Usage 0, Discharging = 0 391 Field 2, app UPS, phys --- 392 Usage 0, ACPresent = 1 393 Field 3, app UPS, phys --- 394 Usage 0, BatteryPresent = 1 395 Field 4, app UPS, phys --- 396 Usage 0, BelowRemainingCapacityLimit = 0 397 Field 5, app UPS, phys --- 398 Usage 0, ShutdownRequested = 0 399 Field 6, app UPS, phys --- 400 Usage 0, ShutdownImminent = 0 401 Field 7, app UPS, phys --- 402 Usage 0, RemainingTimeLimitExpired = 0 403 Field 8, app UPS, phys --- 404 Usage 0, CommunicationLost = 0 405 Field 9, app UPS, phys --- 406 Usage 0, NeedReplacement = 0 407 Field 10, app UPS, phys --- 408 Usage 0, Overload = 0 409 Field 11, app UPS, phys --- 410 Usage 0, VoltageNotRegulated = 0 411 Field 12, app UPS, phys --- 412 Usage 0, [ff860080] = 0 413 414Waiting for events ... (interrupt to exit) 415